FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Suzhou EICCOMM Technology CO., Ltd./
  3. 2AXD8-BLEFILAMENT

2AXD8-BLEFILAMENTLightcloud Blue

Suzhou EICCOMM Technology CO., Ltd.
Lightcloud Blue - FCC ID 2AXD8-BLEFILAMENT - Suzhou EICCOMM Technology CO., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 22, 2022
Application Purpose
Original Equipment
Date of Application
Mar 22, 2022
Equipment Note
Lightcloud Blue
Frequency Range
2402.00000000 - 2480.00000000
Company
Suzhou EICCOMM Technology CO., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Manual Folding • Not suitable for use with dimmers and sensors unless specifically designed for RAB Lightcloud Blue Lamps. • Risk of electric shock. • Do not use where directly exposed to water. • Not intended for use with emergency exit fixtures or emergency lights. • Only install in operating environments between -4°F and 113°F (-20°C to 45°C). • Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. Hello 1(844) LIGHTCLOUD 1(844) 554-4825 Front Back Product Features & Specifications 1(844) LIGHTCLOUD 1(844) 554-4825 WE’RE HERE TO HELP: Welcome ©2022 RAB LIGHTING Inc. Made in China. Pat. rablighting.com/ip 1(844) LIGHTCLOUD 1(844) 554-4825 WE’RE HERE TO HELP: Method 1: Manual Power the lamp off and on 5 times consecutively. Do not allow more than 2 second to elapse between switching. The lamp will flash 3 times, then reset to 100% brightness at default CCT. If your Lightcloud Blue Smart A19 is already paired, you can reset it by using the below methods. 1-10 devices 5 X LCBA19-6-E26-9TW-F-C-SS Pre-Installation FCC Information: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and cprrect the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an ecperienced radio/TV technician for help. Installing your Lightcloud Blue Lamp Installing your Lightcloud Blue Lamp (cont’d) LED A19 with Tunable White Lightcloud APP DRYWALL OR SIMILAR Add an additional Lightcloud Device to ex tend networ k range ar ound corners BRICK, CONCRETE, OR ME TAL WALL <=70 ft. Find a suitable location Use these guidelines when installing devices: • If there is a clear line of sight between a Lightcloud Blue Smart A19 and another Lightcloud Blue device they can be placed up to 200 feet apart. If a Lightcloud Blue Smart A19 and another Lightcloud Blue device are separated by ordinary drywall construction, try to keep them within 70 ft. of each other. Brick, concrete and steel construction may require additional Lightcloud Blue devices to go around the obstruction. • • Lightcloud Safety Information Lightcloud 1(844) LIGHTCLOUD 1(844) 554-4825 WE’RE HERE TO HELP: Welcome LCBA19-6-E26-9TW-F-C-SS LED A19 with Tunable White Lightcloud Catalog Number: LCBA19-6-E26-9TW-F-C-SS Model Number: LCBA19-6-E26-9TW-F-C-SS Electrical: Construction: Lamp Base: E26 6W, 800lm 120Vac 60Hz Lightcloud Blue is a wireless lighting control system that allows you to control RAB Lighting's various compatible devices with your mobile device. Lightcloud Blue lamps are wirelessly controlled locally via the Lightcloud Blue app. Get even more features like secure remote control capability from anywhere that has an internet connection. Lightcloud Gateway and Bridge devices are required to access premium features. Controlling your Lightcloud Blue Device Setting Device to Pairing Mode Wirelessly control from your mobile device On, off and dimming Color tuning Wireless remote control Create custom scenes Lived-in look vacation mode Sensor compatible SmartShift automated circadian schedule Schedules and automations Direct Connect LED, No Gateway or Hub required Lightcloud Blue is a wireless lighting control system. It’s powerful and flexible, yet easy to use and install. Learn more at www.lightcloud.com 1 Turn off power • Place the wall switch in the off position. • Turn off the main power at the breaker panel or remove the fuse from the fuse box. Confirm your device is connected and powered on. 1 2 3 4 5 6 Download the Lightcloud app from the Apple App Store or Google Play store. Launch the App and create an account. Tap the "add device" icon in the app to start connecting devices. Follow the remaining steps in the app. Create areas, groups, and scenes to organize and control your devices. You're all set! Connect device to power. After installed, turn the power on and the lamp will enter pairing mode automatically if it has not already been paired. Once the lamp has been paired, it will indicate by flashing on and off 5 times and then dim to 30% brightness. OFF OFF WARNING Functionality WE’RE HERE TO HELP: 1 (844) LIGHTCLOUD 1 (844) 544-4825 [email protected] using the Lightcloud Blue app. To comply with the FCC’s RF ecposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. CAUTION: Changes or modifications to this equipment not expre…

Text truncated - open the document above for the full version.

Attestation Statements

Company: Suzhou EICCOMM Technology CO., Ltd. Add: Room 304, Building 4, Zhuyuan Road 209, GAOXIN District, Suzhou, Jiangsu Province, China Tel: 18662211697 Fax:18662211697 E-mail: [email protected] Date: 2021 -12-21 Attestation Letter Signature: Typed or Printed Name: JINGJING WU Title: Manager Dear Sir or Madam: The chip TLSR8253F512AT32 installed in our product Lightcloud Blue (model name:LCBA19-6-E26-9TW-F-C-SS,LCBG25-6-E26-9TW-F-C-SS,LCBST19-6-E26-9TW - F-C-SS,LCBB11-5-E26-9TW-F-C-SS; FCC ID:2AXD8-BLEFILAMENT ), which support Bluetooth 5.0, 802.15.4 and 2.4GHz Radio functions. But for the product, it only activates BLE 1Mbps, the other functions are disabled by using the software. Please contact me if there is need for any additional clarification or information. Best Regards, Sincerely Yours, FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046

Cover Letter(s)

Company Name: Suzhou EICCOMM Technology CO., Ltd. Add: Room 304, Building 4, Zhuyuan Road 209, GAOXIN District, Suzhou, Jiangsu Province, China TEL: 18662211697 FAX: 18662211697 E-mail: [email protected] DECLARATION Date: 2021-12-21 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 We, Suzhou EICCOMM Technology CO., Ltd. hereby declare that product name:Lightcloud Blue (FCC ID: 2AXD8-BLEFILAMENT,model name :LCBA19-6-E26-9TW-F-C-SS,LCBG25-6- E26-9TW-F-C-SS, LCBST19-6-E26-9TW-F-C-SS,LCBB11-5-E26-9TW-F-C-SS) are electrically identical with the PCB design, components and electromagnetic compatibility characteristics, and model: LCBA19-6-E26-9TW-F-C-SS has been tested by China Certification ICT Co., Ltd (Dongguan) LCBA19-6-E26-9TW-F-C-SS, LCBG25-6- E26-9TW-F-C-SS, LCBST19-6-E26-9TW- F-C-SS are exactly the same, except for the style of the glass bulb. As for model LCBB11-5-E26-9TW-F-C-SS, compared with other models, it has the lower rated power, different light bar and glass bulb. Please refer to the table below for details: Please contact me if there is need for any additional clarification or information. Best Regards, Signature: Print Name: JINGJING WU Title:Manager

Cover Letter(s)

QA-FR-171-A Suzhou EICCOMM Technology CO., Ltd. ADD: Room 304, Building 4, Zhuyuan Road 209, GAOXIN District, Suzhou, Jiangsu Province, China TEL: 18662211697 FAX: 18662211697 E-mail: [email protected] FCC Confidential Authorization Date: 2021-12-21 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AXD8-BLEFILAMENT In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, (Suzhou EICCOMM Technology CO., Ltd.) hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printed Name: JINGJING WU Title: Manager

Cover Letter(s)

QA-FR-170-B Suzhou EICCOMM Technology CO., Ltd. ADD: Room 304, Building 4, Zhuyuan Road 209, GAOXIN District, Suzhou, Jiangsu Province, China TEL: 18662211697 FAX: 18662211697 E-mail: [email protected] FCC Authorization Date: 2021-12-21 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Suzhou EICCOMM Technology CO., Ltd., Hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: JINGJING WU Title: Manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS LCBA19-6-E26-9TW-F-C-SS LCBG25-6-E26-9TW-F-C-SS LCBST19-6-E26-9TW-F-C-SS LCBB11-5-E26-9TW-F-C-SS

ID Label/Location Info

Lightc loud Blue LCB G25-6-E26-9TW -F-C-SS 肘/1加啜Hz68mA的知啤S 220以劝K卧D�IN CH INA G8JW2 FCCID: 拟D 8--BLEfll.AME

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Antenna Chip

Test Report

TEST REPORT Applicant: Suzhou EICCOMM Technology CO., Ltd. Address: Room 304, Building 4,Zhuyuan Road 209, GAOXIN District, Suzhou, Jiangsu Province, China FCC ID: 2AXD8-BLEFILAMENT Product Name: Lightcloud Blue Model Number: LCBA19-6-E26-9TW-F-C-SS, LCBG25-6-E26-9TW- F-C-SS, LCBST19-6-E26-9TW-F-C-SS, LCBB11-5- E26-9TW-F-C-SS Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR21120040-00 Date Of Issue: 2022-02-18 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR21120040-00 Page 2 of 39 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR21120040-00 Page 3 of 39 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 1. GENERAL INFORMATION .................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 5 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 8 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 2. SUMMARY OF TEST RESULTS .......................................................................................... 10 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 3.1.1 Applicable Standard ..................................................................................................................................... 11 3.1.2 EUT Setup.................................................................................................................................................... 12 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 12 3.1.4 Test Procedure ............................................................................................................................................. 13 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 14 3.2.1 Applicable Standard ..................................................................................................................................... 14 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 15 3.2.4 Test Procedure ............................................................................................................................................. 15 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 15 3.3 6 DB EMISSION BANDWIDTH: ............................................................................................................ 16 3.3.1 Applicable Standard ...............................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz

Contact Information

Applicant

JINGJING WU
[email protected]18662211697Fax: 18662211697

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Suzhou EICCOMM Technology CO., Ltd.

LED tube - FCC ID 2AXD8-BLET8WT - Suzhou EICCOMM Technology CO., Ltd.
2AXD8-BLET8WT

LED tube

Sep 23, 2022

Equipment Class

DTS - Digital Transmission System
RAB Bluetooth Remote Control - FCC ID 2AXD8-LCBLUEREMOTE - Suzhou EICCOMM Technology CO., Ltd.
2AXD8-LCBLUEREMOTE

RAB Bluetooth Remote Control

Jul 28, 2021

Equipment Class

DTS - Digital Transmission System
BLE Controller - FCC ID 2AXD8-BLUECONTROL - Suzhou EICCOMM Technology CO., Ltd.
2AXD8-BLUECONTROL

BLE Controller

Mar 07, 2021

Equipment Class

DTS - Digital Transmission System
Turing Bluetooth module - FCC ID 2AXD8TURING - Suzhou EICCOMM Technology CO., Ltd.
2AXD8TURING

Turing Bluetooth module

Sep 15, 2020

Equipment Class

DTS - Digital Transmission System