FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen USEER Robotics Co.,Ltd./
  3. 2AZ2R-PF

2AZ2R-PFIntelligent Pet Feeder

Shenzhen USEER Robotics Co.,Ltd.
Intelligent Pet Feeder - FCC ID 2AZ2R-PF - Shenzhen USEER Robotics Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 17, 2024
Application Purpose
Original Equipment
Date of Application
Sep 17, 2024
Equipment Note
Intelligent Pet Feeder
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen USEER Robotics Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

物料名称 产品型号 物料编号 版次 PF2说明书(英文) PF2 903-0801-0000 V01 (03.14) 设计: 日期:2023.03.14 平面印刷品基本技术要求 材质:100g双铜纸 印刷颜色:四色印刷+单黑 装订方式:骑马钉装 页数:20p 尺寸:110*158mm 深圳市云视机器人有限公司 比例:1:1 PF2 Intelligent Pet Feeder Manual Please read this manual carefully and keep it properly before using the product. Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio f requency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different f rom that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user5s authority to operate this equipment. RF exposure warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm f rom all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Contents Use Safety Instructions List of Parts Product Introduction Product Use Product Placement Instructions Key Description Indicator Description Connect to App Maintenance Basic Parameters FAQ Maintenance Record Services And Support 1 2 2 4 6 7 8 9 9 13 14 15 15 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 1 1. 12. 13. 14. 1 All accessories of this device are not edible. Please install and use this device strictly according to the instructions. This device is not recommended for pets within three months. Please use this device indoors in a dry environment. Please keep this device horizontally during use, and do not tilt or overturn it. Please store the power cord properly, so as to avoid electricity leakage caused by pet biting. Please do not put items other than pet food into food storage bucket, which will result in abnormal use of device. To prevent pets f rom throwing down the device, it is recommended to place the device in the corner or against the wall. Please do not touch the pet food outlet when the device delivers the food. The host of this device is prohibited f rom soaking in water. It is forbidden to place heavy objects in the food bowl, so as not to affect the weighing function. If children use this device, please make sure to use it under the guidance of adults. Please do not use any non-special accessories. Our company is only responsible for the performance and safety of the accessories provided officially. No one except for maintenance personnel shall disassemble and repair the device to avoid accidental injury. * Please observe the following terms and conditions to avoid that the product cannot be used normally or have any other accidental loss. Use Safety Instructions List of Parts HostAdapterDrying BoxManualFood Bowl 2 Product Introduction Microphone Pet Food Outlet Light Speaker Wi-Fi Indicator Work Indicator Fill Light PF2 Intelligent Pet Feeder Manual Please read this manual carefully and keep it properly before using the product. Camera Food Output Key Wi-Fi Networking Key Uncovering Key Food Bowl Food Bucket Locking Key Upper Cover 3 Drying Box Food Storage Bucket Silica Gel Impeller Unlocking Key Impeller Cover Weighing Platform 4 Power Interface Type-c Input Interface Wire-Wrap Board Product Use Connect the power adapter1. Take out the power adapter and plug it into the power interface at the bottom of the host. Install the host2. ①. Please place the host on a horizontal surface. ②. Put the food bowl on the weighing platform of the host. (As shown below) 5 Open the upper cover3. Pull up the cover opening key and lift it up. Put in the drying box 4. ①. Lay the upper cover flat, rotate the unlocking key clockwise by 60°, and put in the drying box. ②. Rotate the arrow symbol [ ] of unlocking key, and align it to the locking symbol [ ] to complete the locking. Add pet food5. Add the pet food. (Pay attention to the size of pet food) Cover the upper cover 6. Lift the upper cover key and close it downward. 6 Manual feeding7. Click the food output key to output the food; deliver one piece of food at a time. Note: External connection of mobile power supply Can be connected with external mobile power supply to prevent device from being unusable during power failure. Insert the Type-c output interface of the mobile power supply into the Type-c input interface at the bottom of the host. Product Placement Instructions Placement reminder: 1. 2. 3. There should be no foreign bodies (such as food, etc.) stuck at the bottom or edge of the food bowl. The device should be placed on a stable and hard horizontal plane and there should be a distance of more than 3cm kept f rom other objects (such as walls, etc.). Please clamp the power cord of the device …

Text truncated - open the document above for the full version.

Attestation Statements

ShenzhenUSEERRoboticsCo.,Ltd. 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE Company name:Shenzhen USEER Robotics Co.,Ltd. Address:Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China. Product Name:Intelligent Pet Feeder FCC ID:2AZ2R-PF Model(s):PF2, PF2S, PF*, PF**, PF*** (*=0-9 or A-Z, represent different color) 2.911(d)(5)(i) Equipment Type We, [Shenzhen USEER Robotics Co.,Ltd.] certify that the equipment for which authorization is sought through certification is not: 1 Yourssincerely, Signature: Name:XiaoqingqingDate: TitleandCompanyname 2024.8.30 :Projectbusiness/ShenzhenUSEERRoboticsCo.,Ltd. NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

ShenzhenUSEERRoboticsCo.,Ltd. 2.911(d)(5)(ii)ApplicantAttestationv1.2 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) 2.911(d)(5)(ii)Applicantfiling We,[ShenzhenUSEERRoboticsCo.,Ltd.]certifythat,asofthedateofthefilingoftheapplication,the applicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto §1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely Company name:Shenzhen USEER Robotics Co.,Ltd. Address:Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China. ProductName:Intelligent Pet Feeder FCCID:2AZ2R-PF Model(s):PF2, PF2S, PF*, PF**, PF*** (*=0-9 or A-Z, represent different color) , Signature: Name:XiaoqingqingDate: TitleandCompanyname 2024.8.30 :Projectbusiness/ShenzhenUSEERRoboticsCo.,Ltd. NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

ShenzhenUSEERRoboticsCo.,Ltd. 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess 2.911(d)(7)USADesignatedAgentforServiceofProces Company name: Shenzhen USEER Robotics Co.,Ltd. Address: Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China. Product Name: Intelligent Pet Feeder FCC ID: 2AZ2R-PF Model(s):PF2, PF2S, PF*, PF**, PF*** (*=0-9 or A-Z, represent different color) s We,[ ShenzhenUSEERRoboticsCo.,Ltd. ](“theapplicant”)designate[ CleanRobotCorp ] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. ShenzhenUSEERRoboticsCo.,Ltd. 2.911(d)(7)USAAgentv1.5 USAAgent Companyname: CleanRobotCorp USAAddress: 3327COLBYAVESTEB,EVERETT, WA,98201-6403,UNITEDSTATES FRNNumber: 0035839141 ContactName: HuazhongLin TelephoneNo: (913)2086504 Email: [email protected] Applicant Companyname: ShenzhenUSEER RoboticsCo.,Ltd. Address: Building2,FashionBrandIndustrial Park,E'BuTown,Shenzhen-ShanweiSpecial CooperationZone,Shenzhen,Guangdong, China. GranteeFRNNumber:0030959175 FCCGranteeCode: 2AZ2R ContactName:Xiaoqingqing TelephoneNo:15238765187 Email:[email protected] Signature: Title:Marager Signature: Title:Projectbusiness Date:2024.9.1Date:2024.8.30 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

ShenzhenUSEERRoboticsCo.,Ltd. AgentAuthorization Signature : Company:Shenzhen USEER Robotics Co.,Ltd. Address:Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China. Product Name: Intelligent Pet Feeder Model Number(s): PF2, PF2S, PF*, PF**, PF*** (*=0-9 or A-Z, represent different color) Product Description:Intelligent Pet Feeder We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Xiaoqingqing Title Date: 2024.8.30 :Projectbusiness Company: ShenzhenUSEERRoboticsCo.,Ltd.

Cover Letter(s)

ShenzhenUSEERRoboticsCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date: 2024.8.30 Subject; Request for Confidentiality FCC ID:2AZ2R-PF To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SOFTWARESECURITYREQUIREMENTSFORU-NIIDEVICES Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:Xiaoqingqing Title:Projectbusiness ShenzhenUSEERRoboticsCo.,Ltd.

Cover Letter(s)

version01 ShenzhenUSEERRoboticsCo.,Ltd. Modeldifferencestatement It is hereby declared that the product Product Name:Intelligent Pet Feeder Model(s):PF2, PF2S, PF*, PF**, PF*** (*=0-9 or A-Z, represent different color) FCC ID:2AZ2R-PF Trade Mark: / The only difference product models is color of appearance. Different model names are available to meet market demands. Other power supply methods, appearance, internal structures, circuits and key components are the same, and do not affect safety and electromagnetic compatibility performance Sincerely, Signature [Xiaoqingqing] [Projectbusiness] [ ShenzhenUSEERRoboticsCo.,Ltd. ]

ID Label/Location Info

Lablelocation:

Internal Photos

Interna FCC ID:2AZ2R-PF l

RF Exposure Info

KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]: www.gdksign.com RFEXPOSUREEVALUATION 1.PRODUCTINFORMATION FCCID2AZ2R-PF 2.EVALUATIONMETHODANDLIMIT HumanexposuretoRFemissionsfrommobiledevices(47CFR§2.1091)maybeevaluated basedontheMPElimitsadoptedbytheFCCforelectricandmagneticfieldstrengthand/or powerdensity,asappropriate,sinceexposuresareassumedtooccuratdistancesof20cmor morefrompersons. §1.1310(e)(1)LIMITSFORGENERALPOPULATION/UNCONTROLLEDEXPOSURE Frequency Range (MHz) E-fieldStrength (E) (V/m) MagneticField Strength(H) (A/m) PowerDensity (S) (mW/cm 2 ) AveragingTime |E| 2 ,|H| 2 orS (Minutes) 0.3--1.346141.63(100)*30 1.34--30824/f2.19/f(180/f 2 )*30 30--30027.50.0730.230 300--1500----f/150030 1500--100,000----1.030 *Note: 1.f=FrequencyinMHz *=Plane-waveEquivalentPowerDensity 2.TheMPElimitforGeneralPopulation/Uncontrolledexposuretofixedtransmittersisnot applicableforportabletransmitters.Portabledevicesevaluationshallbeperformedaccording totheSARprovisionsin47CFR§2.1093. S=PG/4πR² Where: S=powerdensity(inappropriateunits,e.g.mw/cm 2 ) P=powerinputtoantenna(inappropriateunits,e.g.,mW) G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna(inappropriateunits,e.g.,cm) KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]: www.gdksign.com 3.CALCULATION Aminimumtestseparationdistance≥20cmisrequiredbetweentheantennaandradiating structuresofthedeviceandnearbypersonstoapplymobiledeviceexposurelimits.The distancemustbeatleast20cmandfullysupportedbytheoperatingandinstallation configurationsofthetransmitteranditsantenna(s),accordingtothesource-based time-averagedmaximumpowerrequirementsof§2.1091(d)(2).Incaseswherecablelosses orotherattenuationsareappliedtodeterminecompliance,themostconservativeoperating configurationsandexposureconditionsmustbeevaluated. WIFIPART(Cannottransmitatdifferentbandsimultaneously) 802.11GSinglemode(Worstcase)For2.4GHzWIFI AntennaGain=3.34dBi(Numeric2.16),π=3.14 802.11ASinglemode(Worstcase)For5GHzWIFI AntennaGain=2.72dBi(Numeric1.87),π=3.14 BLE_1Mmode(Worstcase)ForBLE AntennaGain=1.70dBi(Numeric1.48),π=3.14 Note: 1.Antennagainprovidedbytheapplicant.Canaffectthevalidityofresults. 2.Onlytheworstcaserecorded. 3..TheBLE,2.4GWIFIand5GWIFIcantransmitsimultaneously: 0.01412/1+0.00576/1+0.00023/1=0.02011<1. 4.ItsatisfytheRFexposurerequirementsforsimultaneoustransmissionthatthesumofthe MPEradios<1. 5.TomaintaincompliancewiththeRFexposureguidelines,placetheequipmentatleast20cm fromnearbypersons. Result:Compliant --THEEND-- FrequencyOutputPowerOutputPowerPowerDensityPowerDensityLimit MHzdBmmWmW/cm2mW/cm2 246215.1732.89 0.01412 1 FrequencyOutputPowerOutputPowerPowerDensityPowerDensityLimit MHzdBmmWmW/cm2mW/cm2 582511.9015.490.005761 FrequencyOutputPowerOutputPowerPowerDensityPowerDensityLimit MHzdBmmWmW/cm2mW/cm2 2402-1.000.79 0.00023 1

Test Report

深圳众城无线技术有限公司 Shenzhen unity wireless technology co., ltd 1 天 线 测 试报告 Antenna Test Report 频段 : 2.4G/5.8G 制表 TEL :0755-23285621 射频工程师:温财慧 RF Engineer: Wen Caihui TEL:0755-23285621 日期 date:2024.07.30 深圳众城无线技术有限公司 Shenzhen unity wireless technology co., ltd 第 4 页-共11页 工程图纸: Click on UV glue at the golden finger Terminal buckle facing downwards Focus: 2 1.2.3.4.5.6. The wire is neat and tidy, and the skin is not damaged 100% full inspection of finished productsWELDING END TENSILE FORCE: 1.5KGIf the tolerance is not noted, please refer to the general tolerance Copper is poured in the shadow area, and the surface of the finished product is brushed with black oil in other areas ROHS compliant 深圳众城无线技术有限公司 Shenzhen unity wireless technology co., ltd 4 天线匹配(原天线匹配)Antenna matching (original antenna matching) E1E2 E3 N/A0 欧N/A WIFI2.4-5.8G 无源测试结果:WIFI 2.4-5.8G Passive Test Results: 天线方向图:Antenna pattern 深圳众城无线技术有限公司 Shenzhen unity wireless technology co., ltd 5

Test Report

天线测试报告Antennatestreport 天线摆放示意图Antennalayoutdiagram 天线匹配Antennamatching 天线S11AntennaS11 Freq(MHZ)EFFI%GAIN(dBi) 240050.191 242050.920.8 244051.501.7 246054.351.2 248056.510.9 250054.551.3 元件位号 Elementbitnumber 参数 argument C71.5pF L13.9nH C81.5pF 天线增益Antennagain 2440MHz

Test Report

Page1 of 70ReportNo.: KD2407S2683E01 TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo................................:KD2407S2683E01 FCCID.....................................:2AZ2R-PF Applicant..................................:ShenzhenUSEERRoboticsCo.,Ltd. Address....................................: Building2, FashionBrandIndustrialPark,E'BuTown,Shenzhen-Shanwei SpecialCooperationZone,Shenzhen,Guangdong,China. Manufacturer...........................:ShenzhenUSEERRoboticsCo.,Ltd. Address....................................: Building2, FashionBrandIndustrialPark,E'BuTown,Shenzhen-Shanwei SpecialCooperationZone,Shenzhen,Guangdong,China. ProductName ......................... :IntelligentPet Feeder Model/Typereference ............ :PF2,PF2S,PF* , PF** , PF***(*=0-9or A-Z, representdifferentcolo r) Standard..................................:47 CFRPart 15.247 Dateof Receipt.......................:July 04 , 2024 Dateof Test Date....................:July 04 , 2024to August20, 2024 Dateof issue...........................:August21, 2024 Test result ............................... :Pass Conclusion...............................:The submittedsamplewas foundto COMPLYwith the standardsabove. Preparedby: ( Printedname+ Signature) ChadLin Approvedby: ( Printedname+ Signature) Sky Dong TestingLaboratoryName...:KSIGN(Guangdong)TestingCo., Ltd. Address....................................: WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China Page2 of 70ReportNo.: KD2407S2683E01 TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards.......................................................................................................................................3 1.2. ReportVersion.......................................................................................................................................3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. MeasurementUncertainty......................................................................................................................5 2. GENERALINFORMATION..............................................................................................................................6 2.1. GeneralDescriptionOf EUT ..................................................................................................................6 2.2. AccessoryEquipmentInformation.........................................................................................................6 2.3. Descriptionof Test Modes......................................................................................................................6 2.4. Operationchannellist ............................................................................................................................7 2.5. MeasurementInstrumentsList ...............................................................................................................8 3. EvaluationResults(Evaluation)..................................................................................................................10 3.1. Antennarequirement............................................................................................................................10 4. RadioSpectrumMatterTest Results(RF) ..................................................................................................10 4.1. ConductedEmissionat AC powerline .................................................................................................10 4.2. OccupiedBandwidth............................................................................................................................14 4.3. MaximumConductedOutputPower....................................................................................................16 4.4. PowerSpectralDensity........................................................................................................................17 4.5. Emissionsin non-restrictedfrequencybands......................................................................................18 4.6. Bandedgeemissions(Radiated).........................................................................................................19 4.7. Emissionsin frequencybands(below1GHz)......................................................................................24 4.8. Emissionsin frequencybands(above1GHz)......................................................................................27 5. EUT TEST PHOTOS......................................................................................................................................34 6. PHOTOGRAPHSOF EUT CONSTRUCTIONAL..........................................................................................36 Appendix............................................................................................................................................................37 6.1. AppendixA: DTS Bandwidth............................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page1 of 81ReportNo.: KD2407S2683E02 TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo................................:KD2407S2683E02 FCCID.....................................:2AZ2R-PF Applicant..................................:ShenzhenUSEERRoboticsCo.,Ltd. Address....................................: Building2, FashionBrandIndustrialPark,E'BuTown,Shenzhen-Shanwei SpecialCooperationZone,Shenzhen,Guangdong,China. Manufacturer...........................:ShenzhenUSEERRoboticsCo.,Ltd. Address....................................: Building2, FashionBrandIndustrialPark,E'BuTown,Shenzhen-Shanwei SpecialCooperationZone,Shenzhen,Guangdong,China. ProductName ......................... :IntelligentPet Feeder Model/Typereference ............ :PF2,PF2S,PF* , PF** , PF***(*=0-9or A-Z, representdifferentcolor ) Standard..................................:47 CFRPart 15.247 Dateof Receipt.......................:July 04 , 2024 Dateof Test Date....................:July 04 , 2024to August20, 2024 Dateof issue...........................:August21, 2024 Test result ............................... :Pass Conclusion...............................:The submittedsamplewas foundto COMPLYwith the standardsabove. Preparedby: ( Printedname+ Signature) ChadLin Approvedby: ( Printedname+ Signature) Sky Dong TestingLaboratoryName...:KSIGN(Guangdong)TestingCo., Ltd. Address....................................: WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China Page2 of 81ReportNo.: KD2407S2683E02 TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards.......................................................................................................................................3 1.2. ReportVersion.......................................................................................................................................3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. MeasurementUncertainty......................................................................................................................5 2. GENERALINFORMATION..............................................................................................................................6 2.1. GeneralDescriptionOf EUT ..................................................................................................................6 2.2. AccessoryEquipmentInformation.........................................................................................................6 2.3. Descriptionof Test Modes......................................................................................................................6 2.4. Operationchannellist ............................................................................................................................7 2.5. MeasurementInstrumentsList ...............................................................................................................8 3. EvaluationResults(Evaluation)..................................................................................................................10 3.1. Antennarequirement............................................................................................................................10 4. RadioSpectrumMatterTest Results(RF) ..................................................................................................10 4.1. ConductedEmissionat AC powerline .................................................................................................10 4.2. OccupiedBandwidth............................................................................................................................14 4.3. MaximumConductedOutputPower....................................................................................................16 4.4. PowerSpectralDensity........................................................................................................................17 4.5. Emissionsin non-restrictedfrequencybands......................................................................................18 4.6. Bandedgeemissions(Radiated).........................................................................................................19 4.7. Emissionsin frequencybands(below1GHz)......................................................................................24 4.8. Emissionsin frequencybands(above1GHz)......................................................................................27 …

Text truncated - open the document above for the full version.

Contact Information

Applicant

qingqing Xiao
[email protected]15238765187Fax: N.A.

Technical Contact

Shenzhen USEER Robotics Co.,Ltd.
[email protected]

China

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]+(86) 0755-2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz32.89 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen USEER Robotics Co.,Ltd.

2AZ2R-PW7PRO

Smart Litter Box

Jul 17, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Robotic Vacuum Cleaner - FCC ID 2AZ2R-MPS - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-MPS

Robotic Vacuum Cleaner

Apr 16, 2026

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AZ2R-M5 - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-M5

Robotic Vacuum Cleaner

Apr 07, 2026

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AZ2R-L - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-L

Robotic Vacuum Cleaner

Aug 22, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Robotic Vacuum Cleaner - FCC ID 2AZ2R-N - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-N

Robotic Vacuum Cleaner

Apr 10, 2023

Equipment Class

DTS - Digital Transmission System