2AZ2R-PW7PROSmart Litter Box

Shenzhen USEER Robotics Co.,Ltd.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 17, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Litter Box
Frequency Range
5180.00000000 - 5240.00000000
Company
Shenzhen USEER Robotics Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: FCC US Agent, LLC FRN: 0033402884 Contact Name: Tim Payne Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Telephone No: 708-571-3148 Email: [email protected] Applicant: Company name: Shenzhen USEER Robotics Co.,Ltd. Product Description: Smart Litter Box Grantee code: 2AZ2R FCC ID: 2AZ2R-PW7PRO FRN: 0030959175 Contact Name: qingqing Xiao Address: Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China Telephone No: 15238765187 Email: [email protected] Shenzhen USEER Robotics Co.,Ltd. certifies that, as of the date of this filing of the application with the TCB, FCC US Agent, LLC is our designated US agent for service of process for the above referenced FCC ID. Shenzhen USEER Robotics Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. FCC US Agent, LLC accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicantis aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. 1/1 Date: 2026/7/1 Applicant’s Name: qingqing Xiao US Agent’s Name: Tim Payne Title: manager Title: President Signature Signature

Attestation Statements

AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1 TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:ShenzhenUSEERRoboticsCo.,Ltd. Granteecode:2AZ2R FCCID:2AZ2R-PW7PRO FRN:0030959175 ContactName:qingqingXiao Address:Building2,FashionBrandIndustrialPark,E'BuTown,Shenzhen-ShanweiSpecial CooperationZone,Shenzhen,Guangdong,China TelephoneNo:15238765187 FaxNo:N/A Email:[email protected] i.[ShenzhenUSEERRoboticsCo.,Ltd.](“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipment prohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.[ShenzhenUSEERRoboticsCo.,Ltd.](“theapplicant”)certifiesthat,asofthe dateofthefilingoftheapplication,theapplicantisnot(asaspecifically namedentityoranyofitssubsidiariesoraffiliates)identifiedontheCovered Listasanentityproducing“covered”equipment.Theapplicantmustsign thiscertification. [ ShenzhenUSEERRoboticsCo.,Ltd. ](“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,theapplicant[isnot]identifiedontheCoveredListas anentityproducing“covered”equipment. Date:2026/6/24 Applicant’sName:qingqingXiao Title:Manager Signature 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

ShenzhenUSEERRoboticsCo.,Ltd. Code00018768Ed. 1 Item 1.The deviceis able to install software/programinstallation? ☐Yes, go to Item 2. ☑ No. In this case, the rest of the items do not apply.The devicecannotsupportinstallationof Kaspersky cybersecurityor anti-virussoftware. Item 2.TechnicalRequirementsfor KasperskyCybersecuritySoftware: #GeneralRequirements(For all Devices)Yes / No or N/AComments 1Internetconnectionfor activationand updates(For all Operating Systems) N/A DeviceSmartLitterBox CompanynameShenzhenUSEERRoboticsCo.,Ltd. Granteecode2AZ2R FCC ID2AZ2R-PW7PRO FRN 0030959175 Contactname qingqingXiao AddressBuilding2, FashionBrandIndustrialPark,E'Bu Town,Shenzhen-ShanweiSpecialCooperation Zone,Shenzhen,Guangdong,China Telephonenumber 15238765187 E-mail [email protected] Chipset/moduleinformation BL M8733BS2 OperatingSystem(if applicable)N/A StorageCapacity(hard drive or other permanentmemorystorage,if applicable) N/A 2 #GeneralRequirements(ForWindowsDevices)Yes/NoorN/AComments 1Storage:1500MBfreespaceontheharddriveN/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/Enterprise Microsoft Windows7Starter/HomeBasic&Premium/Professional/ UltimateSP1orhigher N/A 3Processor:1GHzorhigher(x86orx64)N/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)N/A 5ScreenResolution:Minimumresolutionof1024x768N/A #GeneralRequirements(FormacOSdevices)Yes/NoorN/AComments 1OperatingSystemmacOS®13–14N/A 2Memory(RAM)4GBN/A 3Storage:3455MBfreespaceontheharddriveN/A #GeneralRequirements(ForAndroidDevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:Android™10–14N/A 3ScreenResolution:Minimumresolutionof320x480N/A #GeneralRequirements(foriOSdevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:iOS®17N/A #GeneralRequirements(ForLinuxsystem)Yes/NoorN/AComments 3 1Harddrive:1GBoffreespaceN/A 2CPU:IntelPentium1GHzorhigher 3RAM:1GB 4Minimumsoftwarerequirements: AlmaLinuxOS8orlater; AlterOS7.5orlater; AstraLinuxCommonEdition2.12orlater; CentOS6.7orlater; DebianGNU/Linux10.0orlater; EulerOS2.0orlater; OracleLinux7.3orlater; RedHatEnterpriseLinux6.7orlater; RockyLinux8.5orlater; SUSELinuxEnterpriseServer12.5orlater; Ubuntu12.04orlater; UncomOSHome/Business/Education/Enterprise2.2orlater; ALTLinuxWorkstaton/WorkstationK/Server/Education8or later; ROSALinuxWorkstation/Server12orlater; REDOS7.3andlater; Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingtheinstallationof Kasperskysoftware? ☐ Yes,gotoItem3. ☑No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky software Item3.ConnectivityCapabilities: 4 #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 Afterthereviewofthisitems,thedevice: ☑Cannotsupportinstallationofanycybersecurityoranti-virussoftwareonthecoveredlist. ☐Potentiallycanoperatewithanycybersecurityoranti-virussoftwareonthecoveredlist–additionalthird- partyproofisprovidedtodemonstratecompliancewithrequirementsasof2.911(d)5(i),(ii)–“Proofof CompliancewithCoveredListSoftwareRequirements”ofthisdocumentapplies Signature:Name:qingqingXiao Date:2026-06-24 1 Thejustificationfieldisusedtojustifywhythesoftwarecannotbereceivedthroughthatinterface.Checktheannexformore indications.

Attestation Statements

TCB CALL página 1 File FCC ID: 2AZ2R-PW7PRO Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://opencorporates.com/companies/us_il/LLC_12842678 In google: TCB CALL página 2 Bank information TCB CALL página 3 TCB CALL página 4 TCB CALL página 5 TCB CALL página 6 TCB CALL página 7 TCB CALL página 8 TCB CALL página 9 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 <ShenzhenUSEERRoboticsCo.,Ltd.> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026/6/24 Subject:RequestforConfidentiality FCCID:2AZ2R-PW7PRO ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotos□ ☒ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotos □ ☒ User’sManual ☐ NOTE 1 ☒ InternalPhotos ☐ NOTE 1 ☒ PartsList/TuneUp ☒☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ □ NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselectedabove arewithheldfrompublicviewforaperiodof__180__daysfromthedateoftheGrant ofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:qingqingXiao Title:Manager

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Le tter of Author iz ation < She nzhe n USEER Robot ics Co. ,Lt d. > Company: Shenzhen USEER Robotics Co.,Ltd. Address: Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen- Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China Product Name: Smart Litter Box Model Number: PW7 Pro FCC Identifier: 2AZ2R-PW7PRO We authorize LGAI Technological Center S.A., Ronda de la Font delCarme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Na me: qing qing XiaoDate: 06/24/2026 Title: mana ger Signa tur e of applicant :

Cover Letter(s)

FCC Software Configuration Control Declaration Rev1.1 Shenzhen USEER Robotics Co.,Ltd. FCC Software Configuration Control Declaration Date: 7/14/2026 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Smart Litter Box / PW7 Pro FCC ID: 2AZ2R-PW7PRO Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: qingqing Xiao Date: 7/14/2026 Title: manager Signature of applicant

ID Label/Location Info

REVDATE USER FNAME Scale Project Date Sheet Revision/Issue Project Name and Address Firm Name and Address No.Date General Notes 产品标签  制图比例1:1 01 2026-05-08 V1.0 Product Model: PW7 Pro Rated Power: 30W HVIN: PW7 Pro Made in China Manufacturer: Shenzhen USEER Robotics Co., Ltd. Address: Building 2, Fashion Brand Industrial Park, E’BuTown, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China. Input: 20V 1.5A Rated Voltage: 24V FCC ID: 2AZ2R-PW7PRO IC: 30186-PW7PRO Smart Litter Box 78mm 42mm REVDATE USER FNAME Scale Project Date Project Name and Address Firm Name and Address PW7/PW7 Pro 制图比例1:1 01 2026-07-15 Revision/IssueNo.Date General Notes 单位:mm

RF Exposure Info

FCC ID: 2AZ2R-PW7PRO Maximum Permissible Exposure (MPE) According to FCC 2.1091, FCC 1.1310 and KDB447498 D01 General RF Exposure Guidance V06: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method E (V/m) = d GP**30 Power Density: Pd (W/m²) = 377 2 E E = Electric field (V/m) P = Average RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = 2 *377 **30 D GP From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. Measurement Result BLE: Antenna gain: 2.98dBi; R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric 24024.424±15 3.1622.981.990.00121 24403.633±14 2.5122.981.990.00101 24803.583±14 2.5122.981.990.00101 tune-up powerGain Channel Freq. (MHz) modulation (mW/cm2) BLE 1M (dBm) Tune-up power (dBm) (mW/cm2 ) MaxAntenna 2.4GWIFI: Antenna gain ANT1: 2.98dBi R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric 241215.8415±116 39.8112.981.990.01571 243716.0416±117 50.1192.981.990.01981 246216.0516±117 50.1192.981.990.01981 241213.513±114 25.1192.981.990.00991 243715.2415±116 39.8112.981.990.01571 246214.1214±115 31.6232.981.990.01251 241211.5811±112 15.8492.981.990.00631 243713.1813±114 25.1192.981.990.00991 246212.112±113 19.9532.981.990.00791 (mW/cm2 )(mW/cm2) 11b MaxAntenna tune-up powerGain (dBm) Tune-up power (dBm) Channel Freq. (MHz) modulation 11g 11n20 5G WIFI: WIFI 5.2G Antenna gain ANT1: 2.57dBi R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric Ant 15180 12.16 12±113.0019.9532.571.810.00721 Ant 15200 11.77 11±112.0015.8492.571.810.00571 Ant 15240 11.17 11±112.0015.8492.571.810.00571 Ant 15180 13.04 13±114.0025.1192.571.810.00901 Ant 15200 11.99 11±112.0015.8492.571.810.00571 Ant 15240 11.36 11±112.0015.8492.571.810.00571 (mW/cm2) 802.11a Channel Freq. (MHz) (dBm) Tune-up power (dBm) Antenna Max 802.11n20 Antenna tune-up powerGain modulation (mW/cm2 ) WIFI 5.3G Antenna gain ANT1: 2.55dBi R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric Ant 15260 12.25 12±113.0019.9532.551.800.00711 Ant 15280 12.17 12±113.0019.9532.551.800.00711 Ant 15320 12.39 12±113.0019.9532.551.800.00711 Ant 15260 12.05 12±113.0019.9532.551.800.00711 Ant 15280 12.3 12±113.0019.9532.551.800.00711 Ant 15320 12.31 12±113.0019.9532.551.800.00711 802.11n20 Antenna tune-up powerGain modulation (mW/cm2 )(mW/cm2) 802.11a Channel Freq. (MHz) (dBm) Tune-up power (dBm) Antenna Max WIFI 5.6G Antenna gain ANT1: 2.91dBi R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric Ant 15500 12.44 12±113.0019.9532.911.950.00781 Ant 15600 11.55 11±112.0015.8492.911.950.00621 Ant 15700 11.29 11±112.0015.8492.911.950.00621 Ant 15500 12.44 12±113.0019.9532.911.950.00781 Ant 15600 11.34 11±112.0015.8492.911.950.00621 Ant 15700 11.54 11±112.0015.8492.911.950.00621 802.11n20 Antenna tune-up powerGain modulation (mW/cm2 )(mW/cm2) 802.11a Channel Freq. (MHz) (dBm) Tune-up power (dBm) Antenna Max WIFI 5.8G Antenna gain ANT1: 2.49dBi R=20cm conducted power Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric Ant 15745 11.34 11±112.0015.8492.491.770.00561 Ant 15785 10.96 10±111.0012.5892.491.770.00441 Ant 15825 11.43 11±112.0015.8492.491.770.00561 Ant 15745 11.2 11±112.0015.8492.491.770.00561 Ant 15785 11.09 11±112.0015.8492.491.770.00561 Ant 15825 11.16 11±112.0015.8492.711.870.00591 802.11n20 Antenna tune-up powerGain modulation (mW/cm2 )(mW/cm2) 802.11a Channel Freq. (MHz) (dBm) Tune-up power (dBm) Antenna Max SIMULTANEOUS TRANSMISSIONS When a number of sources at different frequencies, and/or broadband sources, contribute to the total exposure, it becomes necessary to weigh each contribution relative to the MPE. To comply with the MPE, the fraction of the MPE in terms of E 2 , H 2 (or power density) incurred within each frequency interval should be determined and the sum of all such fractions should not exceed unity. In order to ensure compliance with the MPE for a controlled environment, the sum of the ratios of the power density to the corresponding MPE should not exceed unity. That is Note: The BLE/WIFI 2.4G/WIFI 5G share the same ANT cannot transmit at same time. Conclusion: pass Signature: Date: 2026-05-27 NAME AND TITLE (Please print or type): alex li/Manager COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China

Test Report

Report No.: N26032008320E Version.1.2 Page 1 of 95 FCC RADIO TEST REPORT FCC ID: 2AZ2R-PW7PRO Product: Smart Litter Box Trade Mark: N/A Model Name: PW7 Pro Family Model: N/A Report No.: N26032008320E Prepared for Shenzhen USEER Robotics Co.,Ltd. Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Report No.: N26032008320E Version.1.2 Page 2 of 95 TEST RESULT CERTIFICATION Applicant’s name ................. : Shenzhen USEER Robotics Co.,Ltd. Address .................................. : Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China Manufacturer's Name .......... : Shenzhen USEER Robotics Co.,Ltd. Address .................................. : Building 2, Fashion Brand Industrial Park, E'Bu Town, Shenzhen-Shanwei Special Cooperation Zone, Shenzhen, Guangdong, China Product description Product name ............................ : Smart Litter Box Model and/or type reference : PW7 Pro Family Model ............................. : N/A Sample number S2604100051-1# Standards ............................. : FCC Part15.407 Test procedure ............................... : ANSI C63.10-2020+Cor.1-2023 KDB 789033 D02 General UNII Test Procedures New Rules v02r01 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements/ the Industry Canada requirements.. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of the document. Date of Test ............................................ : Date (s) of performance of tests .............. : Mar. 20, 2026 ~ May 21, 2026 Date of Issue ........................................... : May 21, 2026 Test Result ............................................... : Pass Prepared By : Reviewed By : Approved By : Abel Chen (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Report No.: N26032008320E Version.1.2 Page 3 of 95 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 FACILITIES AND ACCREDITATIONS 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3 . TEST REQUIREMENTS 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.2 RADIATED EMISSION MEASUREMENT 17 3.3 POWER SPECTRAL DENSITY TEST 76 3.4 26DB & 99% EMISSION BANDWIDTH 79 3.5 MINIMUM 6 DB BANDWIDTH 81 3.6 MAXIMUM CONDUCTED OUTPUT POWER 83 3.7 OUT OF BAND EMISSIONS 87 3.8 SPURIOUS RF CONDUCTED EMISSIONS 89 3.9 DYNAMIC FREQUENCY SELECTION(DFS) 90 4. ANTENNA REQUIREMENT 95 4.1 STANDARD REQUIREMENT 95 4.2 EUT ANTENNA 95 Report No.: N26032008320E Version.1.2 Page 4 of 95 Revision History Report No. Version Description Issued Date N26032008320E Rev.01 Initial issue of report May 21, 2026 Report No.: N26032008320E Version.1.2 Page 5 of 95 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.407) , Subpart E Standard Section Test Item Judgment Remark 15.207 AC Power Line Conducted Emissions PASS 15.209(a), 15.407 (b) Spurious Radiated Emissions PASS 15.407 (a) 99% Emission Bandwidth PASS 15.407(e) Minimum 6 dB bandwidth PASS 15.407 (a) Maximum Conducted Output Power PASS 15.407(b) Band Edge PASS 15.407 (a) Power Spectral Density PASS 15.407(b) Spurious Emissions at Antenna Terminals PASS 15.203 Antenna Requirement PASS 15.407(c) Automatically discontinue transmission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: N26032008320E Version.1.2 Page 6 of 95 1.1 FACILITIES AND ACCREDITATIONS FACILITIES All measurement facilities used to collect the measurement data are located at No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. LABORATORY ACCREDITATIONS AND LISTINGS Site Description CNAS-Lab. : The Certificate Registration Number is L5516. IC-Registration The Certificate Registration Number is 9270A. CAB identifier:CN0074 FCC- Accredited Test Firm Registration Number: 463705. Designation Number: CN1184 A2LA-Lab. The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.80dB 2 RF power, conducted ±0.16dB 3 Spurious emissions, conducted ±0.21dB 4 All emissions, radiated(30MHz~1GHz) ±2.64dB 5 All emissions, radiated(1GHz~6GHz) ±2.40dB 6 All emissions, radiated(>6GHz) ±2.52dB 7 Temperature ±0.5°C 8 Humidity ±2% 9 All emissions…

Text truncated - open the document above for the full version.

Test Report

Shenzhen unity wireless technology co., ltd Shenzhen unity wireless technology co., ltd Address: Room 1002/1012, Building 7E, Evergrande Fashion Valley, Dalang, Longhua Distri 1 Antenna Test Report Custome:Yunshi frequency band:2.4G/5.8G Debugging Log: Prepared by:WencaihuiRF Engineer:Wencaihui Date:2026.04.20 Revision Date Revision ContentRevised By Original Version 2024.7.30Initial DebuggingWen CaihuiV1.0 2026.4.20Added 5900MHz DataWen CaihuiV1.0 henzhenunitywirelesstechnologyco.,ltd Shenzhenunitywirelesstechnologyco.,ltd Address:Room1002/1012,Building7E,EvergrandeFashionValley,Dalang,LonghuaDistri 2 1..AntennaMatching(OriginalAntennaMatching) E1E2E3 N/A0欧N/A WIFI2.4-5.8GPassiveTestResults: 2.AntennaRadiationPatterns: Shenzhen unity wireless technology co., ltd Shenzhen unity wireless technology co., ltd Address: Room 1002/1012, Building 7E, Evergrande Fashion Valley, Dalang, Longhua Distri 4 4.Engineering drawing Gold finger UV glue Key Points:1,Cable neat, outer sheath without damage;2,100% full inspection for finished products;3,Soldering terminal pull force: 1.5KG;4,Unless otherwise specified, general tolerances apply;5,Copper pour in hatched/shaded areas; keep out in other areas. Black oil coating on finished surface;6,Compliant with RoHS. henzhenunitywirelesstechnologyco.,ltd Shenzhenunitywirelesstechnologyco.,ltd Address:Room1002/1012,Building7E,EvergrandeFashionValley,Dalang,LonghuaDistri 4 3.TestEquipment Themeasuringinstrumentsaremicrowaveanechoicchamber,networkanalyzerandstandard antenna. Microwavedarkroomdescription: ThisisthemicrowaveanechoicchamberinstalledinShenzhenbyourcompany.Aspartofafar-field measurementsystem,thechambermeasures7.0metersx4.0metersx3.0meters,withaquietzone measuring15cmx15cmx15cm。 picture1Thesetupdiagramfortheinstrumentinthemicrowaveanechoicchamberandtheconnectiondiagram ofthenetworkanalyzerareprovided.Thedistancebetweenthetransmittingantenna(modelTRCLPA0860 800MHz-6GHzusedinthischamber)andthetestantenna(AUT)is1.35meters.Thetestantennaisplaced onarotatingplatform,andbycontrollingtherotationangleoftheplatform,bothroughandprecise measurementscanbeperformedonthetestantenna. Positionthetestantennaontherotatingplatformtomeasureits360-degreefieldstrengthdataacross allplanes(ZYandZXplanes).Subsequently,replacethetestantennawithastandarddipoleantenna (theTRCADseriesdipoleantenna800MHz~2500MHzusedinthisanechoicchamber)andmeasureits360-degree fieldstrengthdatatoestablishagaincalibrationreference.Thegainvalueandpatternofthetest antennacanthenbeobtainedthroughconversionusingEquation1.

Test Report

Report No.: N26032008320E 1 / 99 5.2G WIFI Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT a 5180 Ant1 80.42 0.95 0.49 NVNT a 5200 Ant1 80.33 0.95 0.5 NVNT a 5240 Ant1 80.62 0.94 0.49 NVNT n20 5180 Ant1 79.32 1.01 0.53 NVNT n20 5200 Ant1 79.34 1 0.53 NVNT n20 5240 Ant1 79.7 0.99 0.53 Report No.: N26032008320E 2 / 99 Test Graphs Duty Cycle NVNT a 5180MHz Ant1 Duty Cycle NVNT a 5200MHz Ant1 Report No.: N26032008320E 3 / 99 Duty Cycle NVNT a 5240MHz Ant1 Duty Cycle NVNT n20 5180MHz Ant1 Report No.: N26032008320E 4 / 99 Duty Cycle NVNT n20 5200MHz Ant1 Duty Cycle NVNT n20 5240MHz Ant1 Report No.: N26032008320E 5 / 99 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted AVG Power (dBm) Limit (dBm) Verdict NVNT a 5180 Ant1 12.16 24 Pass NVNT a 5200 Ant1 11.77 24 Pass NVNT a 5240 Ant1 11.17 24 Pass NVNT n20 5180 Ant1 13.04 24 Pass NVNT n20 5200 Ant1 11.99 24 Pass NVNT n20 5240 Ant1 11.36 24 Pass Note: 1. The conducted average power contains duty cycle factor. 2. Belong to Client device. Report No.: N26032008320E 6 / 99 -26dB Bandwidth Condition Mode Frequency (MHz) Antenna -26 dB Bandwidth (MHz) Verdict NVNT a 5180 Ant1 19.497 Report only NVNT a 5200 Ant1 19.254 Report only NVNT a 5240 Ant1 18.993 Report only NVNT n20 5180 Ant1 20.16 Report only NVNT n20 5200 Ant1 19.872 Report only NVNT n20 5240 Ant1 20.349 Report only Report No.: N26032008320E 7 / 99 Test Graphs -26dB Bandwidth NVNT a 5180MHz Ant1 -26dB Bandwidth NVNT a 5200MHz Ant1 Report No.: N26032008320E 8 / 99 -26dB Bandwidth NVNT a 5240MHz Ant1 -26dB Bandwidth NVNT n20 5180MHz Ant1 Report No.: N26032008320E 9 / 99 -26dB Bandwidth NVNT n20 5200MHz Ant1 -26dB Bandwidth NVNT n20 5240MHz Ant1 Report No.: N26032008320E 10 / 99 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT a 5180 Ant1 16.318 NVNT a 5200 Ant1 16.246 NVNT a 5240 Ant1 16.207 NVNT n20 5180 Ant1 17.326 NVNT n20 5200 Ant1 17.242 NVNT n20 5240 Ant1 17.41 Report No.: N26032008320E 11 / 99 Test Graphs OBW NVNT a 5180MHz Ant1 OBW NVNT a 5200MHz Ant1 Report No.: N26032008320E 12 / 99 OBW NVNT a 5240MHz Ant1 OBW NVNT n20 5180MHz Ant1 Report No.: N26032008320E 13 / 99 OBW NVNT n20 5200MHz Ant1 OBW NVNT n20 5240MHz Ant1 Report No.: N26032008320E 14 / 99 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/MHz) Duty Factor (dB) Total PSD (dBm/MHz) Limit (dBm/MHz) Verdict NVNT a 5180 Ant1 0.77 0.95 1.72 11 Pass NVNT a 5200 Ant1 1.21 0.95 2.16 11 Pass NVNT a 5240 Ant1 -0.27 0.94 0.67 11 Pass NVNT n20 5180 Ant1 0.51 1.01 1.52 11 Pass NVNT n20 5200 Ant1 1.07 1 2.07 11 Pass NVNT n20 5240 Ant1 -0.5 0.99 0.49 11 Pass Note: Client devices Report No.: N26032008320E 15 / 99 Test Graphs PSD NVNT a 5180MHz Ant1 PSD NVNT a 5200MHz Ant1 Report No.: N26032008320E 16 / 99 PSD NVNT a 5240MHz Ant1 PSD NVNT n20 5180MHz Ant1 Report No.: N26032008320E 17 / 99 PSD NVNT n20 5200MHz Ant1 PSD NVNT n20 5240MHz Ant1 Report No.: N26032008320E 18 / 99 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBm) Limit (dBm) Verdict NVNT a 5180 Ant1 -38.75 -27 Pass NVNT a 5240 Ant1 -38.95 -27 Pass NVNT n20 5180 Ant1 -38.94 -27 Pass NVNT n20 5240 Ant1 -38.98 -27 Pass Report No.: N26032008320E 19 / 99 Test Graphs Band Edge NVNT a 5180MHz Low Ant1 Band Edge NVNT a 5240MHz High Ant1 Report No.: N26032008320E 20 / 99 Band Edge NVNT n20 5180MHz Low Ant1 Band Edge NVNT n20 5240MHz High Ant1 Report No.: N26032008320E 21 / 9…

Text truncated - open the document above for the full version.

Contact Information

Applicant

qingqing Xiao
[email protected]Fax: N.A.

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, Saint Charles, IL, 60174, US · Saint Charles, Illinois, 60174 · United States

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz20.14 mW
215E5.26 GHz - 5.32 GHz17.34 mW
315E5.50 GHz - 5.70 GHz17.54 mW
415E5.75 GHz - 5.83 GHz13.90 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.

Other Applications from Shenzhen USEER Robotics Co.,Ltd.

Robotic Vacuum Cleaner - FCC ID 2AZ2R-MPS - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-MPS

Robotic Vacuum Cleaner

Apr 16, 2026

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AZ2R-M5 - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-M5

Robotic Vacuum Cleaner

Apr 07, 2026

Equipment Class

DTS - Digital Transmission System
Intelligent Pet Feeder - FCC ID 2AZ2R-PF - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-PF

Intelligent Pet Feeder

Sep 17, 2024

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AZ2R-L - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-L

Robotic Vacuum Cleaner

Aug 22, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Robotic Vacuum Cleaner - FCC ID 2AZ2R-N - Shenzhen USEER Robotics Co.,Ltd.
2AZ2R-N

Robotic Vacuum Cleaner

Apr 10, 2023

Equipment Class

DTS - Digital Transmission System