Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL ULTRASONIC WATER SPRAY WINDOW CLEANING ROBOT 2.4G Small water spray Large water spray Water spray on/off Spot Cleaning Cleaning twice Start(x1)/Pause /Continue To Top/Bottom Left/Right Stop at the end of the glass
Shanxi Jiashida Robot Technology Co., Ltd 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Sep. 25, 2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BAE5-SATUO02 FRN: 0033462797 [Shanxi Jiashida Robot Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Baoliang Wang)
Shanxi Jiashida Robot Technology Co., Ltd 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Sep. 25, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BAE5-SATUO02 FRN: 0033462797 [Shanxi Jiashida Robot Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Baoliang Wang)
Shanxi Jiashida Robot Technology Co., Ltd 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Sep. 25, 2024 Subject; Request for Confidentiality FCC ID: 2BAE5-SATUO02 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Parts List In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Baoliang Wang Title: General Manager
Shanxi Jiashida Robot Technology Co., Ltd 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Letter of Authorization Company: Shanxi Jiashida Robot Technology Co., Ltd Address: 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Product Name: SATUO remote control Model Number(s): SATUO 02 Product Description: SATUO remote control We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Sep. 25, 2024 Name: Baoliang Wang Title: General Manager Company: Shanxi Jiashida Robot Technology Co., Ltd
Report No.: AGC11532240803AP02 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC11532240803AP02 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC11532240803AP02 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report*************************************
FCC ID Label Location 20mm*10mm FCC ID: 2BAE5-SATUO02
Report No.: AGC11532240803AP02 Page 1 of 2 INTERNAL PHOTOS OPEN VIEW OF EUT INTERNAL VIEW OF EUT (FIGURE 1) Report No.: AGC11532240803AP02 Page 2 of 2 INTERNAL VIEW OF EUT (FIGURE 2) INTERNAL VIEW OF EUT (FIGURE 3) ****************************************End of Report************************************* Antenna
Page 1 of 10 RF Exposure Report Report No.: AGC11532240803FH01 FCC ID : 2BAE5-SATUO02 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : SATUO remote control BRAND NAME : N/A MODEL NAME : SATUO 02 APPLICANT : Shanxi Jiashida Robot Technology Co., Ltd DATE OF ISSUE : Sep. 24, 2024 STANDARD(S) : FCC KDB 447498 D01 V06 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC11532240803FH01 Page 2 of 10 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Sep. 24, 2024 Valid Initial Release Report No.: AGC11532240803FH01 Page 3 of 10 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 3. Test Environment ............................................................................................................................................ 6 3.1 Address Of The Test Laboratory ............................................................................................................... 6 3.2 Test Facility ................................................................................................................................................ 6 3.3 Environmental Conditions ......................................................................................................................... 7 4. Portable Device Evaluation Method and Limit ............................................................................................. 8 5. Mobile Device Evaluation Method and Limit ................................................................................................ 9 6. Measurement Results ................................................................................................................................... 10 7. Measurement Evaluation .............................................................................................................................. 10 Report No.: AGC11532240803FH01 Page 4 of 10 1. General Information Applicant Shanxi Jiashida Robot Technology Co., Ltd Address 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Manufacturer Shanxi Jiashida Robot Technology Co., Ltd Address 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Factory Shanxi Jiashida Robot Technology Co., Ltd Address 17/f, huanneng tech block, no17,Gaoxin St., Zonggai shifan dist. Taiyuan, China Product Designation SATUO remote control Brand Name N/A Test Model SATUO 02 Series Model(s) N/A Difference Description N/A Date of receipt of test item Sep. 12, 2024 Date of Test Sep. 12, 2024 to Sep. 24, 2024 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RF Exposure-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Cici Li (Project Engineer) Sep. 24, 2024 Reviewed By Calvin Liu (Reviewer) Sep. 24, 2024 Approved By Max Zhang (Authorized Officer) Sep. 24, 2024 Report No.: AGC11532240803FH01 Page 5 of 10 2. Product Information 2.1 Product Technical Description Frequency Band 2400MHz-2483.5MHz Hardware Version V1.0 Software Version V1.0 Modulation Type GFSK Maximum Transmitter Power -2.684dBm Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Designation PCB Antenna Antenna Gain -3.89dBi Minimum Assessment Distance 5mm Evaluation Applied MPE Evaluation SAR Evaluation Report No.: AGC11532240803FH01 Page 6 of 10 3. Test Environment 3.1 Address Of The Test Laboratory Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to follow CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories.) A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to follow ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files with Registration 975832. IC-Registration No.: 24842(CAB identifier: CN0063) Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the Certification and Engineering Bureau of Industry Canada. The acceptance letter from the IC is maintained in our files with Registration 24842. Report No.: AGC11532240803FH01 Page 7 of 10 3.3 Environmental Conditions NORMAL CONDITIONS Temperature range (°C) 15 - 35 Relative humidity range 20 % - 75 % Pressure range (kPa) 86 - 106 Power supply DC 3.0V Note: The Extreme Temperature and Extreme Voltages declared by the man…
Text truncated - open the document above for the full version.
One-stop communication RF antenna solution service provider Page 1 testrepor Shenzhen Anwei Wireless TechnologyCo., LTD t TEST REPORT catalogue 1. Project profile ................................................................................................................. 1 2. VSWR ....................................................................................................................................... 2 3. Dark room test results ........................................................................... ........................ 3 1. Apple picture .................................................................................................................... 4 2. Direction diagram ............................................................................................................ 5 4. conclusion ......................................................................................................... ................... 6 2nd Floor, East Block, Building 5, Yifenghua Industrial Park, Huaning Road, Dalang, Longhua New District, Shenzhen, Guangdong Province PCB Antenna One-stopcommunicationRFantenna solutionserviceprovider Page2 1.Projectprofile product name Ontologyboardantenna Frequenc yand Antenna material servicefrequency material quality Single frequen cy point 2450MHz PCBonboard Test requireme nts Single-frequencypointbodyantennapassivetest measuring andtest instrumen ts brand AgilentNetwork analyzer modelE5071C brandDarkRoomSATIMO-24 (3D) 2.VSWR One-stopcommunicationRFantenna solutionserviceprovider Page2 One-stop communication RF antenna solution service provider Page 3 3. Dark Room Test Results (Passive Result) Model Frequency(MHz)Efficiency(%)Gain(dbi) VSWR / 245011.98-3.8915 1.13D Apple Figure Pattern Plots of Passive 3D -2450MHz One-stopcommunicationRFantenna solutionserviceprovider Page4 1.2DirectionFigure2DPatternPlotsofPassive 2450MHz-E12450MHz-E2 4.conclusion Thisreportisbasedontheantennaperformancemeasuredinthefinalversionofthe antenna.
Page 1 of 40 FCC Test Report Report No.: AGC11532240803FR01 FCC ID : 2BAE5-SATUO02 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : SATUO remote control BRAND NAME : N/A MODEL NAME : SATUO 02 APPLICANT : Shanxi Jiashida Robot Technology Co., Ltd DATE OF ISSUE : Sep. 24, 2024 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation Of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC11532240803FR01 Page 2 of 40 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Sep. 24, 2024 Valid Initial Release Report No.: AGC11532240803FR01 Page 3 of 40 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ..................................................................................................................... 6 2.2 Test Frequency List ..................................................................................................................................... 6 2.3 Related Submittal(S) / Grant (S) ................................................................................................................. 7 2.4 Test Methodology......................................................................................................................................... 7 2.5 Special Accessories ..................................................................................................................................... 7 2.6 Equipment Modifications ............................................................................................................................. 7 2.7 Antenna Requirement .................................................................................................................................. 7 3. Test Environment ............................................................................................................................................ 8 3.1 Address of the Test Laboratory .................................................................................................................... 8 3.2 Test Facility .................................................................................................................................................. 8 3.3 Environmental Conditions ........................................................................................................................... 9 3.4 Measurement Uncertainty ........................................................................................................................... 9 3.5 List of Equipment Use ............................................................................................................................... 10 4. System Test Configuration ........................................................................................................................... 12 4.1 EUT Configuration ..................................................................................................................................... 12 4.2 EUT Exercise ............................................................................................................................................. 12 4.3 Configuration of Tested System ................................................................................................................ 12 4.4 Equipment Used In Tested System ........................................................................................................... 12 4.5 Summary of Test Results ........................................................................................................................... 13 5. Description of Test Modes ........................................................................................................................... 14 6. Duty Cycle Measurement ............................................................................................................................. 15 7. RF Output Power Measurement .................................................................................................................. 16 7.1 Provisions Applicable ................................................................................................................................. 16 7.2 Measurement Procedure ........................................................................................................................... 16 7.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 16 7.4 Measurement Result ................................................................................................................................. 16 8. 6dB Bandwidth Measurement ...................................................................................................................... 18 8.1 Provisions Applicable ................................................................................................................................. 18 8.2 Measurement Procedure ........................................................................................................................... 18 8.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 18 8.4 Measurement Results ................................................................................................................................ 19 9. Power Spectral Density Measurement ........................................................................................................ 21 9.1 Provisions Applicable .....................................................................…
Text truncated - open the document above for the full version.
Report No.: AGC11532240803AP01 Page 1 of 2 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz Report No.: AGC11532240803AP01 Page 2 of 2 RF CONDUCTED TEST SETUP ****************************************End of Report*************************************
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.45 GHz - 2.45 GHz | 500.00 µW |

Window cleaning robot
Equipment Class
DTS - Digital Transmission System
Window cleaner robot
Equipment Class
DTS - Digital Transmission System
Window cleaner robot
Equipment Class
DTS - Digital Transmission System
Window cleaner robot-Remote control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter