
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Label Out Direction Size: 54x13mm, R1mm, tolerance:0~-0.1mm, Material: White PE sticker 1 1 . 6 1.0 Deer Management Systems LLC Made in Vietnam Input: 12V 2A by Adapter or 9V 2A by Battery Deer Management Systems LLC Made in Vietnam Input: 12V 2A byAdapter or 9V 2A by Battery Deer Management Systems LLC Made in Vietnam Input: 12V 2A byAdapter or 9V 2A by Battery Deer Management Systems LLC Made in Vietnam Input: 12V 2A byAdapter or 9V 2A by Battery Deer Management Systems LLC Made in Vietnam Input: 12V 2A byAdapter or 9V 2A by Battery Trail Camera FCC ID: 2BBNQ-RVP4CD Model: RVP4CD SN: P62628P2Q00000 Deer Management Systems LLC Made in Vietnam Input: 12V 2A by Adapter or 9V 2A by Battery IC: 32065-RVP4CD
RF Test Setup Report No: EFTA26060315-IE-02 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 1 of 2 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Part 15C Test Setup 9kHz-30MHz 30MHz-1GHz RF Test Setup Report No: EFTA26060315-IE-02 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 2 of 2 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 1GHz-18GHz Above 18GHz Picture 1 Radiated Emission Test Setup
RF Test Setup Report No: EFTA25090192-IE-02 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 1 of 1 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. WLAN Test Setup WWAN Test Setup
Prepared by: Xu Ying Approved by: Xu Kai Eurofins TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 RF TEST REPORT Applicant Deer Management Systems LLC FCC ID 2BBNQ-RVP4CD Product Trail Camera Brand Reveal Model Reveal Pro 4.0 / RVP4CD Report No. EFTA26060315-IE-02-R2V1 Issue Date August 17, 2026 Eurofins TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR 47 Part 15C. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. RF Test Report Report No.: EFTA26060315-IE-02-R2V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 2 of 89 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ............................................................................................................................... 5 1.1. Notes of the Test Report ......................................................................................................... 5 1.2. Test Facility ............................................................................................................................. 5 1.3. Testing Location ...................................................................................................................... 5 2. General Description of Equipment Under Test ............................................................................... 6 2.1. Applicant and Manufacturer Information ................................................................................ 6 2.2. General Information ................................................................................................................ 6 3. Applied Standards ........................................................................................................................... 7 4. Test Configuration ........................................................................................................................... 8 5. Test Case ........................................................................................................................................ 9 5.1. Maximum output power .......................................................................................................... 9 5.2. 99% Bandwidth and 6dB Bandwidth .................................................................................... 10 5.3. Band Edge ............................................................................................................................ 11 5.4. Power Spectral Density ........................................................................................................ 12 5.5. Spurious RF Conducted Emissions ...................................................................................... 14 5.6. Unwanted Emission .............................................................................................................. 16 5.7. Conducted Emission ............................................................................................................. 23 6. Test Results .................................................................................................................................. 24 6.1. Maximum output power ........................................................................................................ 24 6.2. 99% Bandwidth and 6dB Bandwidth .................................................................................... 26 6.3. Band Edge ............................................................................................................................ 45 6.4. Power Spectral Density ........................................................................................................ 57 6.5. Spurious RF Conducted Emissions ...................................................................................... 67 6.6. Unwanted Emission .............................................................................................................. 85 6.7. Conducted Emission ............................................................................................................. 86 7. Main Test Instruments................................................................................................................... 87 8. The EUT Appearance ................................................................................................................... 88 9. Test Setup Photos ......................................................................................................................... 89 RF Test Report Report No.: EFTA26060315-IE-02-R2V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 3 of 89 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Version Revision Description Issue Date Rev.0 Initial issue of report. August 7, 2026 Rev.1 Updated data. August 17, 2026 Note: This revised report (Report No.: EFTA26060315-IE-02-R2V1) supersedes and replaces the previously issued report (Report No.: EFTA26060315-IE-02-R2). Please discard or destroy the previously issued report and dispose of it accordingly. RF Test Report Report No.: EFTA26060315-IE-02-R2V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-04-005R Page 4 of 89 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Summary of Measurement Results Number Test Case Clause in FCC rules Verdict 1 Maximum output power 15.247(b)(3) PASS 2 99% Bandwidth and 6dB Bandwidth 15.247(a)(2) C63.10 6.9 PASS 3 Power spectral density 15.247(e) PASS 4 Band Edge 15.247(d) PASS 5 Spurious RF Conducted Emissions 15.247(d) PASS 6 Unwanted Emissions 15.24…
Text truncated - open the document above for the full version.
Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 1 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. ANNEX A: Test Result The radiated emission was measured in the following position: EUT stand-up position (Z axis), lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the loop antenna is coplanar, the others are vertical and horizontal. and the worst case was recorded. Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 2 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 1. Unwanted Emission 1.1. Wi-Fi 2.4GHz The following graphs display the maximum values of horizontal and vertical by software. Blue trace uses the peak detection, Green trace uses the average detection. A symbol ( ) in the test plot below means (dBμV/m) The signal beyond the limit is carrier. 0 10 20 30 40 50 60 70 80 90 100 110 120 23102320 2340 2360 2380 2400 24202430 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.387640000 GHz 52.409 dB V/ 2.388120000 GHz 42.855 dB V/ 802.11b-Channel 1 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 130 2450 2455 2460 2465 2470 2475 2480 2485 2490 2495 2500 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.483575000 GHz 55.160 dB V/ 2.483500000 GHz 47.058 dB V/ 802.11b-Channel 11 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 23102320 2340 2360 2380 2400 24202430 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.371635000 GHz 50.848 dB V/ 2.385450000 GHz 38.415 dB V/ 802.11g-Channel 1 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 130 2450 2455 2460 2465 2470 2475 2480 2485 2490 2495 2500 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.483656250 GHz 54.319 dB V/ 2.484356250 GHz 40.176 dB V/ 802.11g-Channel 11 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 23102320 2340 2360 2380 2400 24202430 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.388645000 GHz 50.691 dB V/ 2.389545000 GHz 39.228 dB V/ 802.11n HT20-Channel 1 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 130 2450 2455 2460 2465 2470 2475 2480 2485 2490 2495 2500 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.483643750 GHz 53.107 dB V/ 2.484062500 GHz 39.862 dB V/ 802.11n HT20-Channel 11 Peak+ Average Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 3 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 0 10 20 30 40 50 60 70 80 90 100 110 120 2310 2320 2340 2360 2380 2400 2420 2440 2450 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.389345000 GHz 39.622 dB V/ 2.387787500 GHz 50.618 dB V/ 802.11n HT40-Channel 3 Peak+ Average 0 10 20 30 40 50 60 70 80 90 100 110 120 2430 2440 2450 2460 2470 2480 2490 2500 Level in dB V/ Frequency in MHz FCC RE PK(Class B) FCC RE AV(Class B) 2.486428750 GHz 52.481 dB V/ 2.485081250 GHz 40.885 dB V/ 802.11n HT40–Channel 9 Peak+ Average Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 4 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Result of RE Sweep the whole frequency band through the range from 9kHz to the 10th harmonic of the carrier. The Radiates Emission from 9kHz to 30MHz and 18GHz to 26.5GHz are more than 20dB below the limit are not reported. Remark: 1. Correction Factor = Antenna factor + Insertion loss (cable loss + amplifier gain) 2. Margin = Limit – Quasi-Peak/ MAX Peak/ Average 3. A symbol ( ) in the test plot below means (dBμV/m) 4. The following graphs display the maximum values of coaxial and coplanar for 9k-30MHz; horizontal and vertical for above 30MHz by software. 5. For below 1GHz QP Level @Spectrum Overview H QP Level @Spectrum Overview V QP Level @Final Results QP Limit For above 1GHz PK Level @Spectrum Overview H PK Level @Spectrum Overview V PK Level @Final Results PK Limit AVG Level @Spectrum Overview H AVG Level @Spectrum Overview V AVG Level @Final Results AVG Limit Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 5 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Continuous TX mode: During the test, the Radiates Emission from 30MHz to 1GHz was performed in all modes with all channels, the test data of the worst-case condition (802.11b CH6) was recorded in this report. 0 20 40 60 80 99 30M 50 60 80 100M200300400 500 800 1G Level in dB V/ Frequency in Hz FCC RE QP Radiates Emission from 30MHz to 1GHz Frequency (MHz) Quasi-Peak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Polarization Azimuth (deg) Correct Factor (dB) 118.795000 29.51 43.50 13.99 175.0 H 157.0 17.4 138.598750 32.31 43.50 11.19 175.0 H 266.0 15.6 141.913750 23.98 43.50 19.52 125.0 H 244.0 15.6 158.403750 30.07 43.50 13.43 175.0 H 254.0 16.1 178.207500 29.35 43.50 14.15 112.0 H 277.0 17.0 188.110000 25.75 43.50 17.75 100.0 H 269.0 18.2 Test Result Report No.: EFTA26060315-IE-02-R2-ANNEX A Eurofins TA Technology (Shanghai) Co., Ltd. Page 6 of 40 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 802.11b CH1 0 20 40 60 80 100 120 1G2G3G Level in dB V/ Frequency in Hz FCC RE PK(Class B) FCC RE AV(Class B) Note: The signal beyond the limit is carrier. Radiates Emission from 1GHz to 3GHz Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Meas. Time (ms) H…
Text truncated - open the document above for the full version.
Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com Antenna Test Report (GA62) Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com Revision History RevisionNoteDate V1New Issue2025.12.16 Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com Data Preview FreqGainEffi (MHz)(dBi)(%) 2400 1.52 42% 2410 1.74 47% 2420 1.96 48% 2430 2.05 51% 2440 2 51% 2450 2.15 51% 2460 1.89 49% 2470 1.91 51% 2480 1.38 45% 2490 1.29 42% 2500 0.94 38% Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com 1. RF Fixture Experiment 1.1 Test Setup 1.1.1 VNA Test Setup VSWR and Return Loss measurements (S11) were performed using an KeySight E5071C Network Analyzer. The isolation between antennas is also tested. The testing was performed with apparatus in free space. 1.1.2 Anechoic Chamber Test Setup The gain of the antenna was measured in the anechoic chamber. The chamber provides less than –30 dB reflectivity from 400 MHz through 6 GHz. The chamber size is:7m*4m*3m. The measurement results are calibrated using a leaky wave horn standard. We can measure the antenna gain and efficiency accurately. +Z +Y +X Horn Antenna Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com 2.Antenna Solution 2. RF matching circuit for different antennas IC6.8NH 1PF N/A Ant1 Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com S11(BT) Radiation patterns:3D Radiation patterns:2D 2400MHz Tel:021-54266190 Fax:021-54266191 Web:www.zxsignal.com 2450MHz 2500MHz 规格承认书 SPECIFICATION FOR APPROVAL 日期 DATE: 2026.3.9 版本 REV.: V1.0 客户 AsiatelcoTechnologiesCo. CUSTOMER: 客户料号 CUSTOMERP/N: 品名 GA61-LTEAntenna PARTNAME: 供方料号 SUPPLIERP/N: 送样日期 Date: 送样数量 Q’TY: Pcs 客户确认 CUSTOMER APPROVED BY 工程研发部 生产采购部 承认 ENGINEERR&DDEPTBUSSINESSDEPTAPPROVEDBY 供方确认 SUPPLIER SIGNATURE 研发部工程部批准 ENGINEERR&DDEPTENGINEERR&DDEPTAPPROVAL 宋旭辉周俊傅以成 Index 1. RF Fixture Experiment ..................................................................................................... 1 1.1 Test Setup ..................................................................................................................... 3 1.2 UE configuration ........................................................................................................... 4 2. Test Result ....................................................................................................................... 5 2.1 Passive Test Result(S parameters) ................................................................................ 5 2. 2 Radiation Patterns:2D ............................................................................................... 6 3. Mechanical instruction .................................................................................................. 10 1. RF Fixture Experiment 1.1Test Setup 1.1.1 VNA Test Setup VSWR and Return Loss measurements (S11) were performed using an KeySight E5071C Network Analyzer. The isolation between antennas is also teste. The testing was performed with apparatus in free space. 1.1.2 Anechoic Chamber Test Setup When we test Gain and Efficiency of the antenna, we will use the Multi-Probe OTA Measurement System 3D chamber. The chamber provides test frequency from 400MHz to 6GHz.Thereal test environment is showing as following picture 1.2 UE configuration 1.2.1 Antenna location pictures 1.2.2 RF matching for different antennas LTE antenna matching 2. Test Result 2.1Passive Test Result(S parameters) LTE antenna S11 2.2Radiation Patterns:2D 700M 750M 800M 850M 900M 950M 1700M 1800M 1900M 2000M 2100M 2200M 2500M 2600M 2700M 深 圳 市 瑞 强 通 信 有 限 公 司 备注:本图纸由深圳市瑞强通信有限公司内部发行 未经允许任何人不得擅自拷贝、改动或带离公司. 机 种 品 名 料 号 材 质 模面处理 外观处理 日期 设计 审核 确认 单位 结构 射频 比例 版本 位置 修 改 内 容 版 本 修 订 V1 日 期 RF PA 专业射频方案提供商 2025.04.08 外置天线 RQ03B140780-LTE 周俊 周俊 W3.0 LTE天线 1 6 3 2 4 5 7 截面1-1 由 Autodesk 教育版产品制作 由 Autodesk 教 育 版 产 品 制 作 由 Autodesk 教育版产品制作 由 Autodesk 教 育 版 产 品 制 作 规格承认书 SPECIFICATION FOR APPROVAL 日期 DATE: 2026.03.09 版本 REV.: V1.0 客户 AsiatelcoTechnologiesCo. CUSTOMER: 客户料号 CUSTOMERP/N: 品名 GA61-WIFIAntenna PARTNAME: 供方料号 SUPPLIER P/N: RQ03B140836B-WIFI 送样日期 Date: 送样数量 Q’TY: Pcs 客户确认 CUSTOMER APPROVED BY 工程研发部 生产采购部 承认 ENGINEERR&DDEPTBUSSINESSDEPTAPPROVEDBY 供方确认 SUPPLIER SIGNATURE 研发部工程部批准 ENGINEERR&DDEPTENGINEERR&DDEPTAPPROVAL 宋旭辉周俊傅以成 Index 1. RF Fixture Experiment ..................................................................................................... 3 1.1 Test Setup ..................................................................................................................... 3 1.2 UE configuration ........................................................................................................... 4 2. Test Result ....................................................................................................................... 5 2.1 Passive Test Result(S parameters) ................................................................................ 5 3. Mechanical instruction .................................................................................................... 7 1. RF Fixture Experiment 1.1Test Setup 1.1.1 VNA Test Setup VSWR and Return Loss measurements (S11) were performed using an KeySight E5071C Network Analyzer. The isolation between antennas isalso teste. The testing was performed with apparatus in free space. 1.1.2 Anechoic Chamber Test Setup When we test Gain and Efficiency of the antenna, we will use the Multi-Probe OTA Measurement System 3D chamber. The chamber provides test frequency from 400MHz to 6GHz.Thereal test environment is showing as following picture 1.2 UE configuration 1.2.1 Antenna location pictures 1.2.2 RF matching for different antennas Antenna matching 2. Test Result 2.1Passive Test Result(S parameters) Antenna S11 WIFI Gain&Efficiency&PhaseCenter 增益、效率和相位中心 frequency 频率 (MHz) gain 增益 (dBi) efficiency 效率 (dB) efficiency 效率 (%) 2400 2.02 -3.39 45.77 2410 2.25 -2.91 51.14 2420 2.34 -2.64 54.51 2430 1.85 -3.07 49.31 2440 1.91 -2.94 50.84 2450 2.29 -2.44 56.97 2460 2.22 -2.44 57.07 2470 2.24 -2.48 56.44 2480 2.01 -2…
Text truncated - open the document above for the full version.
Prepared by: Wei Fangying Approved by: Xu Kai Eurofins TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 MPE Evaluation Report Applicant Deer Management Systems LLC FCC ID 2BBNQ-RVP4CD Product Trail Camera Brand Reveal Model Reveal Pro 4.0 / RVP4CD Report No. EFTA26060315-IE-03-M1V1 Issue Date August 17, 2026 Eurofins TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC 47 CFR Part 1 §1.1310, §2.1091. The test results show that the equipment tested can demonstrate compliance with the requirements as documented in this report. MPE Evaluation Report Report No.: EFTA26060315-IE-03-M1V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 2 of 10 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Version Revision Description Issue Date Rev.0 Initial issue of report. August 17, 2026 Rev.1 Updated data. Updated information. August 17, 2026 Note: This revised report (Report No.: EFTA26060315-IE-03-M1V1) supersedes and replaces the previously issued report (Report No.: EFTA26060315-IE-03-M1). Please discard or destroy the previously issued report and dispose of it accordingly. MPE Evaluation Report Report No.: EFTA26060315-IE-03-M1V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 3 of 10 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Table of Contents 1 Test Laboratory ................................................................................................................................. 4 1.1 Notes of the Test Report ............................................................................................................ 4 1.2 Test Facility ................................................................................................................................ 4 1.3 Testing Location......................................................................................................................... 4 2 Description of Equipment Under Test ............................................................................................... 5 3 Maximum Tune up and Antenna Gain .............................................................................................. 6 4 MPE Limit .......................................................................................................................................... 7 5 RF Exposure Evaluation Result ........................................................................................................ 9 ANNEX A: The EUT Appearance ........................................................................................................... 10 MPE Evaluation Report Report No.: EFTA26060315-IE-03-M1V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 4 of 10 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2 Test Facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) Eurofins TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform measurements. 1.3 Testing Location Company: Eurofins TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: https://www.eurofins.com/electrical-and-electronics E-mail: [email protected] MPE Evaluation Report Report No.: EFTA26060315-IE-03-M1V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 5 of 10 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. 2 Description of Equipment Under Test Client Information Applicant Deer Management Systems LLC Applicant address 1668 Jordan West Road Decorah, IA 52101, USA Manufacturer Deer Management Systems LLC Manufacturer address 1668 Jordan West Road Decorah, IA 52101, USA General Technologies EUT Description Model Reveal Pro 4.0 / RVP4CD SN PGD2604260004003 Hardware Version 1.0 Software Version 3.0.9.16 Frequency Band TX (MHz) RX (MHz) LTE Band 2 1850 ~ 1910 1930 ~ 1990 LTE Band 4 1710 ~ 1755 2110 ~ 2155 LTE Band 5 824 ~ 849 869 ~ 894 LTE Band 12 699 ~ 716 729 ~ 746 LTE Band 13 777 ~ 787 746 ~ 756 LTE Band 14 788 ~ 798 758 ~ 768 LTE Band 25 1850 ~ 1915 1930 ~ 1995 LTE Band 66 1710 ~ 1780 2110 ~ 2180 Wi-Fi 2.4G 2412 ~ 2462 2412 ~ 2462 Bluetooth LE 2402 ~ 2480 2402 ~ 2480 Date of Testing June 29, 2026 ~ July 16, 2026 Date of Sample Received June 25, 2026 Note: 1. The EUT is sent from the applicant to Eurofins TA and the information of the EUT is declared by the applicant. 2. All indications of Pass/Fail in this report are opinions expressed by Eurofins TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. MPE Evaluation Report Report No.: EFTA26060315-IE-03-M1V1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-014S Page 6 of 10 This report shall not be reproduced except in full, without the writte…
Text truncated - open the document above for the full version.
Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 1 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo RVP4CD: Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 2 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 3 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 4 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 5 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 6 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 7 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 8 of 8 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd.
Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 1 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Reveal Pro 4.0: Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 2 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 3 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 4 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 5 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 6 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 7 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 8 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 9 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 10 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Internal photo Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 11 of 11 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd.
Deer Management Systems LLC To: Federal Communications Commission Date: 2026/08/13 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) [Deer Management Systems LLC] (“the applicant”) certifies that t…
Text truncated - open the document above for the full version.
1668 Jordan West Road · Decorah, Iowa, 52101 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 21.50 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.60 mW |

Scout WiFi v2
Equipment Class
JAB - Part 15 Class B Digital DeviceTrail Camera
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Wind sensor
Equipment Class
DTS - Digital Transmission System
Trail Camera
Equipment Class
PCB - PCS Licensed Transmitter
Defend Cam
Equipment Class
DTS - Digital Transmission System