2BD5N-SEAGULLPRORobotic Pool Cleaner

Shenzhen Aiper Intelligent Co.,Ltd.
Robotic Pool Cleaner - FCC ID 2BD5N-SEAGULLPRO - Shenzhen Aiper Intelligent Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 18, 2024
Application Purpose
Original Equipment
Date of Application
Jun 18, 2024
Equipment Note
Robotic Pool Cleaner
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Aiper Intelligent Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual ROBOTIC POOL CLEANERROBOTICPPPPOOOOL CLEANERROBOTICCC PPPOOOOL CLEANER Seagull Pro Seagull Pro-JUF FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio / TV technician for help. Radiation Exposure Statement: 1. This equipment complies with FCC radiation exposure limits set forth for an uncon- trolled environment. 2. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. IC Statement This device complies with Industry Canada licenseICES-003. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Radiation Exposure Statement:  This equipment complies with IC radiation exposure limits set forth for an uncon- trolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. $FUÏRVJQFNFOUFTUDPOGPSNFBVYMJNJUFTEhFYQPTJUJPOBVYSBZPOOFNFOUT*$ÏUBCMJFTQPVSVO FOWJSPOOFNFOUOPODPOUSÙMÏ $FUÏRVJQFNFOUEPJUÐUSFJOTUBMMÏFUVUJMJTÏBWFDVOFEJTUBODFNJOJNBMFEFDNFOUSFMFSBEJBUFVSFU WPUSFDPSQT Importer. Aiper Intelligent, LLC. Address: 13851 Ramona Ave, Chino, CA 91710, USA. US Toll-Free1-866-850-0666 AU Toll-Free+61(180)049-7023 1 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.n. Warning:Changes or modifications not expressly approved by the partyresponsibsible le forfor compliance could void the user's authority to operate the equipment. Note:This equipment has been tested and found to comply with the limits for aClassB B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provvideideide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined bbby ty urning the equipment off and on, the user is encouraged to try to correct the interferfereerennce by one or more of the following measures: (1) Reorient or relocate the receceiviivingngantenna. (2) Increase the separatrationionbebetwtween the equipment and receiver. (3) Connect the e equequipmipmente into an outlet on a circuit different from that to which the receiver is conconecctedted. (4)ConConsulsult tt thehedealer or an experienced radio / TV technician for help. RaRaRadididiatatioioion ExExExpopossure Statement: 1. T1. T1. Thiseqequipuipmenmentct complies with FCC radiation exposure limits set forth for an uncon- trooollelled ed envinvironronment. 2.2.ThiThis es eqquipment should be installed and operated with minimum distance 20cm beteween the radiator & your body. IC Statement This device complies with Industry Canada licenseICES-003. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicicicablablables aux appareils radio exempts de licence. L'exploitation est autorisée aux deuux cxondonditiitioons suivantes : (1) l'appareil ne doit pas produire de brouillage,et (2) l'utilisateur de de l'al'appppareil doit accepter tout brouillage radioélectriquesubi, même si le brouillageesst st suscuscepteptible d'en compromettre le fonctionnement. Radiation Exposure Statement:  This equipment complies with IIIC rCrC radiadiadiatiation exposure limits set forth for an uncon- trolled environment. This equipment shou…

Text truncated - open the document above for the full version.

External Photos

FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Model: Seagull Pro(Fast charge version) Model: Seagull Pro (slow charge version) & Seagull Pro Lite

ID Label/Location Info

139mm(±2mm) 100mm(±2mm) 107mm(±2mm) 75mm(±2mm)75mm(±2mm) 二维码位置 尺寸:15*15mm S/N码位置 (由工厂添加与更新) 字体:Gilmer Regular 字号为 9.5 S/N: ****************** (由工厂添加与更新) www.aiper.com Made in China Model: Seagull Pro Charger Input: AC120V, 60Hz, 5A Charger Output: DC29.4V, 9A Power: 25.2V, 3.2A, 80W Temperature max: 35°C/ 95°F Date Code: 2308 1. FOR OUTDOOR USE 2. DO NOT RUN PUMP DRY 3. FOR USE ONLY WITH AC/DC ADAPTOR, MODEL:GC330-2940900-1F 4. FOR USE WITH SWIMMING POOLS ONLY 5. TO REDUCE THE RISK OR INJURY, USER MUST READ MANUAL 6. ENCLOSURE TYPE 3 7. IMPEDANCE PROTECTED CAUTION MISE EN GARDE 1. POUR UTILISATION EN PLEIN AIR 2. NE PAS FAIRE FONCTIONNER À SEC 3. À UTILISER UNIQUEMENT AVEC UN ADAPTATEUR DE AC/DC 4. POUR UNE UTILISATION AVEC PISCINES SEULEMENT 5. POUR REDUIRE LE RISQUE OU LA BLESSURE, L'UTILISATEUR DOIT LIRE LE MANUEL 6. BOÎTIER DE TYPE 3 7. IMPÉDANCE PROTÉGÉE 5026076 This device complies with Part 15 of the FCC rules. Operation of the product is subject to the following: (1) This device may not cause intentional harm. (2) This device accepts any interference received, including interference that may cause undesired operation. CONFORMS TO UL STD. 1081 CERTIFIED TO CSA STD. C22.2 NO. 108 www.aiper.com Made in China Model: Seagull Pro Charger Input: AC120V, 60Hz, 5A Charger Output: DC29.4V, 9A Power: 25.2V, 3.2A, 80W Temperature max: 35°C/ 95°F Date Code: 2308 1. FOR OUTDOOR USE 2. DO NOT RUN PUMP DRY 3. FOR USE ONLY WITH AC/DC ADAPTOR, MODEL:GC330-2940900-1F 4. FOR USE WITH SWIMMING POOLS ONLY 5. TO REDUCE THE RISK OR INJURY, USER MUST READ MANUAL 6. ENCLOSURE TYPE 3 7. IMPEDANCE PROTECTED CAUTION MISE EN GARDE 1. POUR UTILISATION EN PLEIN AIR 2. NE PAS FAIRE FONCTIONNER À SEC 3. À UTILISER UNIQUEMENT AVEC UN ADAPTATEUR DE AC/DC 4. POUR UNE UTILISATION AVEC PISCINES SEULEMENT 5. POUR REDUIRE LE RISQUE OU LA BLESSURE, L'UTILISATEUR DOIT LIRE LE MANUEL 6. BOÎTIER DE TYPE 3 7. IMPÉDANCE PROTÉGÉE This device complies with Part 15 of the FCC rules. Operation of the product is subject to the following: (1) This device may not cause intentional harm. (2) This device accepts any interference received, including interference that may cause undesired operation. IC31793-SEAGULLPRO FCC ID2BD5N-SEAGULLPRO IC31793-SEAGULLPRO FCC ID2BD5N-SEAGULLPRO 5026076 CONFORMS TO UL STD. 1081 CERTIFIED TO CSA STD. C22.2 NO. 108 Dimension:139*100mm(±2mm) Material:PC+ABS Color:Pantone Black C 160mm(±2mm) 75.2mm(±2mm) 106mm(±2mm) 68mm(±2mm) 68mm(±2mm) S/N码位置 (由工厂添加与更新) 字体:Gilmer Regular 字号为 9.5 二维码位置 尺寸:15*15mm (由工厂添加与更新) CAUTION MISE EN GARDE 5026076 This device complies with Part 15 of the FCC rules. Operation of the product is subject to the following: (1) This device may not cause intentional harm. (2) This device accepts any interference received, including interference that may cause undesired operation. CONFORMS TO UL STD. 1081 CERTIFIED TO CSA STD. C22.2 NO. 108 www.aiper.com Made in China Model: Seagull Pro Charger Output: 29.4V 3A Power: 70W Temperature max: 35°C/ 95°F Date Code: 2309 Charger Input: 100~240V, 60/50Hz IC31793-SEAGULLPRO FCC ID2BD5N-SEAGULLPRO 1. FOR OUTDOOR USE 2. DO NOT RUN PUMP DRY 3. FOR USE ONLY WITH AC/DC ADAPTOR, MODEL:GC330-2940900-1F 4. FOR USE WITH SWIMMING POOLS ONLY 5. TO REDUCE THE RISK OR INJURY, USER MUST READ MANUAL 6. ENCLOSURE TYPE 3 7. IMPEDANCE PROTECTED 1. POUR UTILISATION EN PLEIN AIR 2. NE PAS FAIRE FONCTIONNER À SEC 3. À UTILISER UNIQUEMENT AVEC UN ADAPTATEUR DE AC/DC 4. POUR UNE UTILISATION AVEC PISCINES SEULEMENT 5. POUR REDUIRE LE RISQUE OU LA BLESSURE, L'UTILISATEUR DOIT LIRE LE MANUEL 6. BOÎTIER DE TYPE 3 7. IMPÉDANCE PROTÉGÉE CAUTION MISE EN GARDE This device complies with Part 15 of the FCC rules. Operation of the product is subject to the following: (1) This device may not cause intentional harm. (2) This device accepts any interference received, including interference that may cause undesired operation. CONFORMS TO UL STD. 1081 CERTIFIED TO CSA STD. C22.2 NO. 108 5026076 www.aiper.com Made in China Model: Seagull Pro Charger Output: 29.4V 3A Power: 70W Temperature max: 35°C/ 95°F Date Code: 2309 Charger Input: 100~240V, 60/50Hz IC31793-SEAGULLPRO FCC ID2BD5N-SEAGULLPRO 1. FOR OUTDOOR USE 2. DO NOT RUN PUMP DRY 3. FOR USE ONLY WITH AC/DC ADAPTOR, MODEL:GC330-2940900-1F 4. FOR USE WITH SWIMMING POOLS ONLY 5. TO REDUCE THE RISK OR INJURY, USER MUST READ MANUAL 6. ENCLOSURE TYPE 3 7. IMPEDANCE PROTECTED 1. POUR UTILISATION EN PLEIN AIR 2. NE PAS FAIRE FONCTIONNER À SEC 3. À UTILISER UNIQUEMENT AVEC UN ADAPTATEUR DE AC/DC 4. POUR UNE UTILISATION AVEC PISCINES SEULEMENT 5. POUR REDUIRE LE RISQUE OU LA BLESSURE, L'UTILISATEUR DOIT LIRE LE MANUEL 6. BOÎTIER DE TYPE 3 7. IMPÉDANCE PROTÉGÉE S/N: ****************** Dimension:160*75.2mm(±2mm) Material:PC+ABS Color:Pantone Black C 139mm(±2mm) 100mm(±2mm) 107mm(±2mm) 75mm(±2mm)75mm(±2mm) 二维码位置 尺寸:15*15mm S/N码位置 (由工厂添加与更新) 字体:R oboto Regular 字号为 9.5 S/N: ****************** (由工厂添加与更新) This device complies with Part 15 of the FCC rules. Operation of the product is subject to the following: (1) This device may not cause intentional harm. (2) This device accepts any interference received, including interference that may cause undesired operation. CONFORMS TO UL STD. 1081 CERTIFIED TO CSA STD. C22.2 NO. 108 Model: Seagull Pro Lite Charger Input: 100~240V, 60/50Hz Charger Output: 29.4V 3A Power: 70W Date Code: 2306 w ww.aiper.c om Made in China IC: 31793-SEAGULLPRO FCC ID: 2BD5N-SEAGULLPRO 1. F OR OUTDOOR USE 2. DO NOT RUN PUMP DRY 3. FOR USE ONLY WITH AC/DC ADAPTOR, MODEL:GC330-2940900-1F 4. FOR USE WITH SWIMMING POOLS ONLY 5. TO REDUCE THE RISK OR INJURY, USER MUST READ MANUAL 6. ENCLOSURE TYPE 3 7. IMPEDANCE PROTECTED C AUTION MISE EN G ARDE 1.POUR UTILISATION EN PLEIN AIR 2. NE PAS FAIRE FONCTIONNER À SEC 3. À UTILISER UNIQUEMENT AVEC UN ADAPTATEUR DE AC/DC 4. POUR UNE UTILISATION AVEC PISCINES SEULEMENT 5. POUR REDUIRE LE RISQUE OU LA BLESSURE, L'UTILISATEUR DOIT LIRE LE MANUEL 6. BOÎTIER DE TYPE 3 7.IMPÉDANCE PROTÉGÉE 5026076 …

Text truncated - open the document above for the full version.

Internal Photos

FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Model: Seagull Pro(Fast charge version) Model: Seagull Pro (slow charge version) & Seagull Pro Lite BT Antenna BT Antenna

RF Exposure Info

RF Exposure evaluation FCC ID: 2BD5N-SEAGULLPRO Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Antenna Information The device can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna Identification in Internal photos Antenna type and antenna number Operate frequency band Maximum antenna gain BT BT PCB antenna 2.4GHz – 2.5 GHz -1.08dBi 5. Conducted power and Manufacturing Tolerance [2.4GHz BT] Mode Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Tune-Up[dBm] BLE 1M 2402 1.29 1±1 2440 1.43 1±1 2480 1.68 1±1 BLE 2M 2402 1.29 1±1 2440 1.39 1±1 2480 1.65 1±1 6. Standalone MPE Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain antenna, the RF power density can be obtained. BT Modulation Type Max. Output power with Tune_up Antenna Gain (dBi) Antenna Gain (linear) Duty Cycle MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBm mW BLE 2 1.5849 -1.08 0.7798 100% 0.0002 1.0000 Remark: 1. Output power (Average) including turn-up tolerance; 2. Output power was adjust to duty cycle at 100% if measured duty cycle less than 98%; 3. MPE evaluate distance is 20cm from user manual provide by manufacturer. 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------

Test Report

Shenzhen ZTX Communication Technology Co., Ltd B7AR150_Measured Report of Antenna Shenzhen ZTX Communication Technology Co., Ltd qPhotograph of the Module qAntenna Size qMatching Parameter qPhotograph of Antenna Measurement qMeasured Data of Antenna Catalog Shenzhen ZTX Communication Technology Co., Ltd Photograph of the Module Shenzhen ZTX Communication Technology Co., Ltd Antenna Size unit: mm Shenzhen ZTX Communication Technology Co., Ltd Matching Parameter E10.8nH E2NC E31.2pF Shenzhen ZTX Communication Technology Co., Ltd Photograph of Antenna Measurement Shenzhen ZTX Communication Technology Co., Ltd VSWR Shenzhen ZTX Communication Technology Co., Ltd Return loss Shenzhen ZTX Communication Technology Co., Ltd Smith Chart Shenzhen ZTX Communication Technology Co., Ltd Efficiency&Peak Gain FrequencyEfficiencyPeak Gain Mhz%dBdB 2400 21.37 -6.70 -2.72 2410 24.92 -6.04 -1.98 2420 27.19 -5.66 -1.58 2430 29.41 -5.31 -1.20 2440 30.78 -5.12 -1.08 2450 31.76 -4.98 -1.08 2460 31.44 -5.03 -1.20 2470 31.34 -5.04 -1.18 2480 30.24 -5.19 -1.28 2490 28.65 -5.43 -1.51 2500 26.83 -5.71 -1.84 Shenzhen ZTX Communication Technology Co., Ltd Radiation pattern XOYXOZ YOZ Z XY 2440MHz Shenzhen ZTX Communication Technology Co., Ltd Thank You

Test Report

Shenzhen CTL Testing Technology Co., Ltd. Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Tel: +86-755-89486194 E-mail: [email protected] Annex for BLE Test Report No.: CTL2404187011-WF & CTL2404187011-IC TABLE OF CONTENTS Annex for BLE ........................................................................................................................................... 1 1. Bandwidth ............................................................................................................................................. 2 2. Maximum Conducted Output Power ................................................................................................... 10 3. Maximum Power Spectral Density ...................................................................................................... 15 4. Unwanted Emissions In Non-restricted Frequency Bands .................................................................. 19 FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 2 / 28 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 1.492 / Pass 2440 1 1.527 / Pass 2480 1 1.400 / Pass 2M SISO 2402 1 2.140 / Pass 2440 1 2.334 / Pass 2480 1 2.452 / Pass FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 3 / 28 1.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 4 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 5 / 28 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 6 / 28 1.2 6dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.848 >=0.5 Pass 2440 1 0.887 >=0.5 Pass 2480 1 0.959 >=0.5 Pass 2M SISO 2402 1 0.986 >=0.5 Pass 2440 1 1.163 >=0.5 Pass 2480 1 1.212 >=0.5 Pass FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 7 / 28 1.2.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 8 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 9 / 28 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 10 / 28 2. Maximum Conducted Output Power 2.1 Power 2.1.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 1.29 <=30 Pass 2440 1.43 <=30 Pass 2480 1.68 <=30 Pass 2M SISO 2402 1.29 <=30 Pass 2440 1.39 <=30 Pass 2480 1.65 <=30 Pass Note1: Antenna Gain: Ant1: -1.08dBi; FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 11 / 28 2.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 12 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 13 / 28 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 14 / 28 2.2 EIRP 2.2.1 Test Result Mode TX Type Frequency (MHz) E.I.R.P (dBm) Verdict ANT1 Limit 1M SISO 2402 0.21 <=36.02 Pass 2440 0.35 <=36.02 Pass 2480 0.60 <=36.02 Pass 2M SISO 2402 0.21 <=36.02 Pass 2440 0.31 <=36.02 Pass 2480 0.57 <=36.02 Pass Note1: Antenna Gain: Ant1: -1.08dBi; Note2: E.I.R.P = Measured Power + Antenna Gain FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 15 / 28 3. Maximum Power Spectral Density 3.1 PSD 3.1.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit 1M SISO 2402 -13.36 <=8 Pass 2440 -14.25 <=8 Pass 2480 -13.23 <=8 Pass 2M SISO 2402 -15.22 <=8 Pass 2440 -16.13 <=8 Pass 2480 -15.79 <=8 Pass Note1: Antenna Gain: Ant1: -1.08dBi; FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 16 / 28 3.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 17 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 18 / 28 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 19 / 28 4. Unwanted Emissions In Non-restricted Frequency Bands 4.1 Ref 4.1.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO 2402 1 1.00 2440 1 1.12 2480 1 1.37 2M SISO 2402 1 0.91 2440 1 0.98 2480 1 1.24 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 20 / 28 4.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 21 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 22 / 28 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 23 / 28 4.2 CSE 4.2.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict 1M SISO 2402 1 1.37 -18.63 Pass 2440 1 1.37 -18.63 Pass 2480 1 1.37 -18.63 Pass 2M SISO 2402 1 1.24 -18.76 Pass 2440 1 1.24 -18.76 Pass 2480 1 1.24 -18.76 Pass Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 24 / 28 4.2.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 25 / 28 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 26 / 28 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 27 / 28 2M_LCH_2402MHz_Ant1_NTNV 2M_MCH_2440MHz_Ant1_NTNV FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO Page 28 / 28 2M_HCH_2480MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV

Test Report

Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT 47 CFR Part 15, Subpart C 15.247 Report Reference No. ................. : CTL2404187011-WF Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Yapeng Jin (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name .............................. : Robotic Pool Cleaner Model/Type reference ................. : Seagull Pro List Model(s) ................................ : Seagull Pro Lite Trade Mark ................................... : Aiper FCC ID .......................................... : 2BD5N-SEAGULLPRO Applicant’s name ........................ : Shenzhen Aiper Intelligent Co.,Ltd. Address of applicant .................. : 32nd floor, Block C, Phase 2 Galaxy World, Minle community, Minzhi street, Longhua district, Shenzhen, China Test Firm ...................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm .................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ........................ : Standard ........................................ : 47 CFR Part 15, Subpart C 15.247: Operation within the bands 902-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz. TRF Originator .............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF ................................... : Dated 2011-01 Date of receipt of test item ......... : Apr. 25, 2024 Date of Test Date ......................... : Apr. 25, 2024-May 20, 2024 Date of Issue ................................ : May 22, 2024 Result ........................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 39 Report No.: CTL2404187011-WF TEST REPORT Test Report No. : CTL2404187011-WF May 22, 2024 Date of issue Equipment under Test : Robotic Pool Cleaner Sample No : CTL2404187011 Model /Type : Seagull Pro Listed Models : Seagull Pro Lite Applicant : Shenzhen Aiper Intelligent Co.,Ltd. Address : 32nd floor, Block C, Phase 2 Galaxy World, Minle community, Minzhi street, Longhua district, Shenzhen, China Manufacturer : Shenzhen Aiper Intelligent Co.,Ltd. Address : 32nd floor, Block C, Phase 2 Galaxy World, Minle community, Minzhi street, Longhua district, Shenzhen, China Test result Pass * * In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 39 Report No.: CTL2404187011-WF ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release May 22, 2024 CTL2404187011-WF Tracy Qi V1.0 Page 4 of 39 Report No.: CTL2404187011-WF Table of Contents Page 1. SUMMARY............................................................................................................................................................ 5 1.1. TEST STANDARDS ........................................................................................................................................................... 5 1.2. TEST DESCRIPTION .............................................................................................................................................................. 5 1.3. TEST FACILITY ..................................................................................................................................................................... 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ..................................................................................................................... 6 2. GENERAL INFORMATION ........................................................................................................................................... 8 2.1. ENVIRONMENTAL CONDITIONS .............................................................................................................................................. 8 2.2. GENERAL DESCRIPTION OF EUT ............................................................................................................................................ 8 2.3. DESCRIPTION OF TEST MODES AND TEST FREQUENCY ................................................................................................................ 9 2.4. EQUIPMENTS USED DURING THE TEST .................................................................................................................................. 10 2.5. RELATED SUBMITTAL(S) / GRANT (S) .................................................................................................................................... 11 2.6. MODIFICATIONS ............................................................................................................................................................... 11 3. TEST CONDITIONS AND RESULTS ............................................................................................................................ 12 3.1. CONDUCTED EMISSIONS TEST ............................................................................................................................................. 12 3.2. RADIATED EMISSIONS AND BAND EDGE ...........................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2BD5N-SEAGULLPRO IC: 31793-SEAGULLPRO

Contact Information

Applicant

Ivy Xu
[email protected]+8613025810304Fax: /

Test Firm

Shenzhen CTL Testing Technology Co., Ltd.Tracy Qi
[email protected]86-755-89486194

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Aiper Intelligent Co.,Ltd.

ROBOTIC POOL SKIMMER - FCC ID 2BD5N-SKB30D - Shenzhen Aiper Intelligent Co.,Ltd.
2BD5N-SKB30D

ROBOTIC POOL SKIMMER

Jul 21, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Cordless Robotic Pool Cleaner - FCC ID 2BD5N-PRX30SE - Shenzhen Aiper Intelligent Co.,Ltd.
2BD5N-PRX30SE

Cordless Robotic Pool Cleaner

Feb 23, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
CORDLESS ROBOTIC POOL CLEANER - FCC ID 2BD5N-PRN30 - Shenzhen Aiper Intelligent Co.,Ltd.
2BD5N-PRN30

CORDLESS ROBOTIC POOL CLEANER

Jan 28, 2026

Equipment Class

DTS - Digital Transmission System