FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DAMASCO TRADING LLC/
  3. 2BQHT-T11620-6

2BQHT-T11620-610.95 inch Tablet

DAMASCO TRADING LLC
10.95 inch Tablet - FCC ID 2BQHT-T11620-6 - DAMASCO TRADING LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 13, 2026
Application Purpose
Original Equipment
Equipment Note
10.95 inch Tablet
Frequency Range
2402.00000000 - 2480.00000000
Company
DAMASCO TRADING LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

10.95 inch 9V2.22A FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harm full interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specific Absorption Rate (SAR) information: This Device meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement the SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. The Device has also been tested against this SAR limit. This device was tested for typical body-worn operations with the back of the device kept 0mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain an 0mm separation distance between the user's body and the back of the device. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

RF Exposure Info

      !"#$"#%&'%()* $+$',-./012 34/54 06789$#'$$' :;<= '!& !+#>?@AB= '?A* C&*$@ABDAAE 'FGFHFIJFKL(MFNMKOHNPK(IFL(HP QRSTUVRWXYRWZ[\ ]^_^`abcdefgha`i`fcjba kalmgednbaopaqh_pefqarstucvagiawbaxfq`a yelmeg stsz{|}~]w€r‚yw€ƒ ƒcbfjpchfeg`cha„ …†‡‡ˆ‰Š‹ ŒˆŽ‹‘‘ ’ “ ”•–”—–˜”˜™ š››œžŸ ¡ Ÿ¢£¤¥¦§ ̈©ª«¡£ž¥¦§ ̈ª¬­ ®›¢ ̄¡°¡Ÿ±¡²±¢£³³³ ́›¢μœ¡› ́μœ ¶· ̧¹º»¼½¾¿ÀÁÂÿ¹¿ÀÁ¹Á·¿¾¿Á·»ºÄÀºÃ¿¹½ÅÁ¹ÆÃ»¾ÄÀļ¼Ã¿º ̧Á¿ºÇÈÉÿƿÿÀ¼¿º ̧»ſ¼ÄÅ ̧ÊÃÄÁ ̧»À Â¿ÃÆ»Ã¾¿º ̧ÀËÌͽ¹ ̧ÀÎÁ·¿ÏÐËÐÇÈÉÁ¿¹ÁÊ¿À¼·ÑÈÅżÄÅ ̧ÊÃÄÁ ̧»Àÿ¹½ÅÁ¹ÄÿÁÃļ¿ÄÊÅ¿Á» ÀÄ Á ̧»ÀÄž¿ÁûŻÎÒ ̧À¹Á ̧Á½Á ̧»À¹Ñ        !"#$%&'#$ () !%)*!)"+, -./0./-1-123 -4567289:3; <=>?@ABCDEFBG=D?HEIB=DAJ? KJ?L=J?MNOPQRSTUVWXYZ[\]^_\`abcdceVS fg?Ch?MNOPQRSTUVWXYZ[\]^_\`abcdceVS iLLJFj?MNOkl`^^Zmno`_^p`qmr`omrst_r[\omr uvvwxyz{x|}~€z{}‚v ƒ„…†‡†ˆ‰Š‹‰‹ˆŒ‹ zŽx Š‘’‹“”• –—˜™š›œ žŸ ¡¢£¤Ÿ¥¦§ ̈©ªªª©«©¬¬©­® ̄°©±²²³ ́¥§μ­μ²¦ ̈ª¶¡·¢Ÿ ̧¹ º»¼½¾¿ÀÁ™ÃĽ»—ÅÅÃ¿ÄÆ™Ç™ÈÇ¿¾ÁÀ™¾É™ÊÀ™ÈļÃËÁÅſǼÃȗÇÄÉ̼Ļ¿ÁÄÄ»™ÌǼÄę×ÈÈǿ͗ſËÎÏÐўҟ¶ÓÔ·Õ £¤¶·ÓÖ·Ó¤£¶ÓŸ×ҟ՟¶Ó¶Ø¤·ÙŸÚØŸ× ·Ó¢ÛԷդҟ¡ÚÕ¡·ØŸÔ·ÕÜ Ò¶ÖÒ¶¤¶ØØÚÙ ¶¤¤Ÿ×£Ó×¶ØÓ·¤¤·ÙŸÕŸ¢Ÿ£ØŸ×¶ÓÜÒ·¢Ÿ·Õ¡£Õ¤Ü¶¤Ò·Ú¤ÜÕ¶¤¤ŸÓ£¡¡Õ· ̧£¢·Ô­® ̄© ÝÞßÞàßá â ã ÝÞßÞàßá â ã ÝÞßÞàßá â ã äåæåçæè é ê ë ì             !"#$%&!'# ( )*'&+ $",-!( ./"#$%&!)-&"'0!'# ( .1 "23 #"42!'# 5555555555555555555555555555555555555555555555555555555( (62-%"4 !6!7#$ (!%" 8#--9%'"4 !-55555555555555555555555555555555555555555555555555 (6&72 '&239%'"4 !-555555555555555555555555555555555555555555555555555 62-%"4 !+ &"!2' !: !%" 8#--55555555555555555555555555555555555555555555555555555555555555 )'4 -'# 62-%"4 !555555555555555555555555555555555555555555555555555 .;23'$2!'# 62-%"4 !5555555555555555555555555555555555555555555555555555 23'<"2!'# 62-%"4 !-%3!- !%" 8#--2 $40$2 & =2$8'9%'$555555555555555555555555555555555555 !%" 8#--2 $40$2 & >#$:8'9%'$555555555555555555555555555555555555 .6&72 '&23)'4 -'# -5555555555555555555555555555555555555555555555555555 ?;23'$2!'# 42-%"4 !? ?=2$8'9%'$62-%"4 !55555555555555555555555555555555555555555555555555? ?@62-%"4 !-%3!A'!7=2$8'9%'$555555555555555555555555555555555555B ?.>#$:8'9%'$62-%"4 !55555555555555555555555555555555555555555555555555C ?(@62-%"4 !-%3!A'!7>#$:8'9%'$5555555555555555555555555555555555D B8'-!#E9%'04 ! FGHIJKLMM NOPQRSTUVIWXQOGYYWSXZI[I\[SRUTIR]I^TI\XPW_U YYS[PW\G[X]`PXOSUXXOI`[PXXIWG\\[SaGYS_bcdefghijklmnopiljqljpoijhrghmhijisplthushr ljvwklmpghxumxlshklmygiqgipissutnipphrojrisjlpplthmhvhoshrijyglvhlmxompyipglupymipphjoxxmlzovlk{|}~ €‚ƒ„…€†‡ˆ‰Š‹‹‹ŠŒŠŠŽ‘Š’““”•†ˆ–Ž–“‡‰‹—‚˜ƒ€™š › œ           !"#$%&'() *&%)*+")#+#'((+,-%*!,.'",()*##*%,*!/-*!011123451 6'77*") +)$10801 9:#*+)$+,$#%,,,)&$";%7#'#$%,<(+#',()*#-#*(=+7"$+*"%)# +)$*!(+# ',()*#*!+*>,;,%,($*%=,"-*!+**!;,%$'&*&%(;7"#>"*!*!%, ()*"%)$#*+ )$+,$# ?  @   ABCDEBFGHBIJBKL M="& -;5N5<3ONPQ1R11S1M0T5U1 N+)'+&*',,VWX N%$7<0M3O <,"+7S'(/,<SO982YM0T9Z3O[OO T,%$'&*%)$"*"%)\)>8'#$]^#$ -+,7-&+7"/ ,+*"%)")*,=+7"#,&%(()$$ _      O2Z1S1U0SR5N 05S `abcdef`fghiajklmjnlopqlroksdjtsuvlknlpjwwotmjpwsnonxsyzzz{|}~451 6'77*") +)$10801 9:#*+)$+,$# !;,%$'&*"#$#")$%,'#>"*!*!5N5<*#*/)&! %)7- €‚ƒ„…†‡ˆ‰Š†Š‹Œ‡Ž‘Ž’“”•–“— ˜™š›œžŸŸ ¡¢£¤¥¦§ ̈›©ª£¡™««©¥ª¬›­›®­¥¤§¦›¤ ̄›°¦›®ª¢©±§ ««¥­¢©®™­ª ̄²¢ª¡¥§ªª¡›²­¢ªª›©™®®­¥³™«¥± ́μ¶· ̧¹º»¼½¾¿ÀÁ»¾¼Ã¾¼ÂÁ»¼ºÄ¹º¿º»¼»Å¾ƺÇÅºÄ ¾¼Èɽ¾¿Â¹ºÊǿʾź½¾¿Ë¹»Ã¹»Â»ÅÅÇÆÀ»ÂºÄÁ¼Ä»Å¼¾Â¾ƺ¿ºÈºÁźĻ¼Ë¹¾Èº¾¿ÊÁ¿Â˻¹¾ÇÂË¿»Âº¼ÁÊÊ¿¾ÌÁȾ½ÍÎÏÐ ÑÒÓ…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:2BQHT-T11620-6 Test Setup Photos of the EUT FCC ID:2BQHT-T11620-6

Test Report

39 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 40 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 41 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 42 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 43 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference 44 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 45 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 2DH5 Ant1 2402 2.92 3.75 77.87 1.09 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 3DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 46 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 47 2DH5_Ant1_2402 2DH5_Ant1_2441 48 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 49 3DH5_Ant1_2480

Test Report

1 FCC Appendix RF Test Data for BT FCC ID : 2BQHT-T11620-6 Company : DAMASCO TRADING LLC EUT : 10.95 inch Tablet Model Number : T11620-6 Report No. : CTA25112200107 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.945 2401.553 2402.498 --- --- 2441 0.954 2440.547 2441.501 --- --- 2480 0.963 2479.541 2480.504 --- --- 2DH5 Ant1 2402 1.320 2401.346 2402.666 --- --- 2441 1.341 2440.340 2441.681 --- --- 2480 1.335 2479.343 2480.678 --- --- 3DH5 Ant1 2402 1.314 2401.352 2402.666 --- --- 2441 1.278 2440.382 2441.660 --- --- 2480 1.332 2479.346 2480.678 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 6 3DH5_Ant1_2480 7 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.86809 2401.5740 2402.4421 --- --- 2441 0.86782 2440.5749 2441.4427 --- --- 2480 0.87113 2479.5753 2480.4465 --- --- 2DH5 Ant1 2402 1.1885 2401.4168 2402.6053 --- --- 2441 1.1913 2440.4160 2441.6073 --- --- 2480 1.1891 2479.4178 2480.6069 --- --- 3DH5 Ant1 2402 1.1863 2401.4171 2402.6034 --- --- 2441 1.1871 2440.4172 2441.6043 --- --- 2480 1.1832 2479.4193 2480.6025 --- --- 8 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 9 2DH5_Ant1_2402 2DH5_Ant1_2441 10 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 11 3DH5_Ant1_2480 12 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 0.31 ≤20.97 PASS 2441 0.07 ≤20.97 PASS 2480 -0.03 ≤20.97 PASS 2DH5 Ant1 2402 -0.51 ≤20.97 PASS 2441 -0.79 ≤20.97 PASS 2480 -0.79 ≤20.97 PASS 3DH5 Ant1 2402 -0.54 ≤20.97 PASS 2441 -0.71 ≤20.97 PASS 2480 -0.79 ≤20.97 PASS 13 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 1.032 ≥0.963 PASS 2DH5 Ant1 Hop 1.084 ≥0.894 PASS 3DH5 Ant1 Hop 1.028 ≥0.888 PASS 14 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 15 16 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.390 320 0.125 ≤0.4 PASS DH3 Ant1 Hop 1.640 161 0.264 ≤0.4 PASS DH5 Ant1 Hop 2.890 105 0.303 ≤0.4 PASS 2DH1 Ant1 Hop 0.390 319 0.124 ≤0.4 PASS 2DH3 Ant1 Hop 1.640 157 0.257 ≤0.4 PASS 2DH5 Ant1 Hop 2.890 108 0.312 ≤0.4 PASS 3DH1 Ant1 Hop 0.390 319 0.124 ≤0.4 PASS 3DH3 Ant1 Hop 1.650 159 0.262 ≤0.4 PASS 3DH5 Ant1 Hop 2.900 116 0.336 ≤0.4 PASS 17 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 18 DH5_Ant1_Hop 19 2DH1_Ant1_Hop 2DH3_Ant1_Hop 20 2DH5_Ant1_Hop 21 3DH1_Ant1_Hop 3DH3_Ant1_Hop 22 3DH5_Ant1_Hop 23 24 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS 25 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 26 27 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -0.33 -59.68 ≤-20.33 PASS High 2480 -0.43 -52.14 ≤-20.43 PASS Low Hop_2402 -4.10 -62.49 ≤-24.1 PASS High Hop_2480 -3.77 -57.27 ≤-23.77 PASS 2DH5 Ant1 Low 2402 -3.69 -55.9 ≤-23.69 PASS High 2480 -4.22 -59.27 ≤-24.22 PASS Low Hop_2402 -5.13 -63.43 ≤-25.13 PASS High Hop_2480 -3.59 -55.75 ≤-23.59 PASS 3DH5 Ant1 Low 2402 -3.79 -61.07 ≤-23.79 PASS High 2480 -4.26 -55.6 ≤-24.26 PASS Low Hop_2402 -3.48 -62.08 ≤-23.48 PASS High Hop_2480 -5.64 -58.3 ≤-25.64 PASS 28 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 29 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 30 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 31 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 32 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 33 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -1.05 -1.05 --- PASS 30~1000 -1.05 -56.3 ≤-21.05 PASS 1000~26500 -1.05 -43.35 ≤-21.05 PASS 2441 Reference -1.08 -1.08 --- PASS 30~1000 -1.08 -66.34 ≤-21.08 PASS 1000~26500 -1.08 -43.9 ≤-21.08 PASS 2480 Reference -1.12 -1.12 --- PASS 30~1000 -1.12 -67.47 ≤-21.12 PASS 1000~26500 -1.12 -44.4 ≤-21.12 PASS 2DH5 Ant1 2402 Reference -6.42 -6.42 --- PASS 30~1000 -6.42 -67.86 ≤-26.42 PASS 1000~26500 -6.42 -47.84 ≤-26.42 PASS 2441 Reference -5.84 -5.84 --- PASS 30~1000 -5.84 -66.88 ≤-25.84 PASS 1000~26500 -5.84 -49.32 ≤-25.84 PASS 2480 Reference -5.00 -5.00 --- PASS 30~1000 -5.00 -67.51 ≤-25 PASS 1000~26500 -5.00 -49.68 ≤-25 PASS 3DH5 Ant1 2402 Reference -6.74 -6.74 --- PASS 30~1000 -6.74 -67.34 ≤-26.74 PASS 1000~26500 -6.74 -46.25 ≤-26.74 PASS 2441 Reference -7.20 -7.20 --- PASS 30~1000 -7.20 -64.78 ≤-27.2 PASS 1000~26500 -7.20 -48.03 ≤-27.2 PASS 2480 Reference -6.42 -6.42 --- PASS 30~1000 -6.42 -68.15 ≤-26.42 PASS 1000~26500 -6.42 -47.95 ≤-26.42 PASS 34 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 35 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 36 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 37 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 38 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA25112200107 2BQHT-T11620-6 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Dec. 02, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : DAMASCO TRADING LLC Address ............................................ : 3847 NE 168TH ST APT 3C NORTH MIAMI BEACH 33160 FLORIDA USA FLORIDA, FL 33160 Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : 10.95 inch Tablet Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen KTC Technology Co., Ltd. Model/Type reference ...................... : T11620-6 Listed Models ................................... : N/A Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : DC 3.8V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25112200107 Page 2 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : 10.95 inch Tablet Model /Type : T11620-6 Listed Models : N/A Applicant : DAMASCO TRADING LLC Address : 3847 NE 168TH ST APT 3C NORTH MIAMI BEACH 33160 FLORIDA USA FLORIDA, FL 33160 Manufacturer : Shenzhen KTC Technology Co., Ltd. Address : No.4023 Wuhe Road, Bantian Subdistrict, Longgang District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25112200107 Page 3 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS .......................................................................................................................................... 4 2 SUMMARY ........................................................................................................................................................ 5 2.1 General Remarks .................................................................................................................................... 5 2.2 Product Description ................................................................................................................................. 5 2.3 Equipment Under Test ............................................................................................................................ 5 2.4 Short description of the Equipment under Test (EUT) ............................................................................ 5 2.5 EUT configuration .................................................................................................................................... 6 2.6 EUT operation mode ............................................................................................................................... 6 2.7 Block Diagram of Test Setup .................................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) .............................................................................................................. 6 2.9 Modifications ........................................................................................................................................... 6 3 TEST ENVIRONMENT ...................................................................................................................................... 7 3.1 Address of the test laboratory ................................................................................................................. 7 3.2 Test Facility ............................................................................................................................................. 7 3.3 Environmental conditions ........................................................................................................................ 7 3.4 Summary of measurement results ........…

Text truncated - open the document above for the full version.

Test Report

深圳市亿圣邦科技有限公司第 1 页 深圳市亿圣邦科技有限公司 样 品 承 认 书 SPECIFICATIONFORAPPROVAL 公司名称(客户填写):深圳市普耐尔电子有限公司 物料代码(客户填写): 规格型号(客户填写):A1119D(8786)-LTE 承认日期(客户填写): 供应商 名 称(SLK填写):深圳市亿圣邦科技有限公司 供应商 名 称(SLK填写):WIFI+GPS:SLK-PNE-2921N13V1-R-30IV-G 4G MAIN:SLK-PNE-6812HV1-L-85IV-B4G AUX:SLK-PNE-2004-L-85IV-B 承认签章 供 应 商 承 认(SLK填写栏)深圳普耐尔电子有限公司 工 程 师审 核批 准工 程 师审 核批 准 陈仕联黄震林美财 盖章签署盖章签署 日期202 5-11-15日期 批示:□接受□有条件接受 备注(客户填写): Manufacturer: Shenzhen Yishengbang Technology Co., Ltd. Address: Room 101, Building C, Shenzhen Qianwan Hard Technology Industrial Park, Bao'an District, Shenzhen 电 话: 18025305599电 话: 18666299104 深圳市亿圣邦科技有限公司第 2 页 WIFI+GPSAntenna(2921N13V1) 1.ExplanationofProductnumber: SLK-PNE-2921N13V1-R-30IV-G 12345 ProductCode: (1)Customer: PNE:普耐尔 (2)Project: 2921N13V1:SLK-2921N13V1(WiFi+GPSantenna) (3)WeldingPosition R:Right (4)CableLength: 30IV:30*0.81MM四代端子 (5)CableColor G:Gray 2.Features *Stableandreliableinperformances *Compactsize *RoHScompliance 深圳市亿圣邦科技有限公司第 3 页 3.Applications *IEEE802.11(a/b/g/n) *Hand-helddeviceswhenWIFI(802.11a/b/g/n)GPSfunctionsareneeded 4.Description Holybond’sFPCantennaseriesarespeciallydesignedforWIFI(802.11 a/b/g/n)GPSapplications.BasedonHolybond’sproprietarydesignand processes,thisFPCantennahasexcellentstabilityandsensitivityto consistentlyprovidehighsignalreceptionefficiency. 5.ElectricalSpecifications 5-1 CharacteristicsSpecificationsUnit OutlineDimensions 29.7x21.92x0.12 mm CenterFrequency 1.575+2.4-2.5+5.15-5.85 GHz Bandwidth(under-10dBreturnloss) 130minMHz VSWR 3max 5-2. VSWRS11 深圳市亿圣邦科技有限公司第 4 页 5-3.WIFI+GPSAntennaGain/Efficiency/RadiationPatternof3D Frequency(MHz)Efficiency(dBi)Gain(dBi)Efficiency(%) 天线增益(dbi) 1570.0 -4.78 0.6133.25 0.821575.0 -4.68 0.7334.08 1580.0 -4.63 0.8234.46 2400.0 -4.78 0.8933.23 1.27 2410.0 -4.76 1.1933.44 2420.0 -4.68 1.1334.01 2430.0 -4.60 1.1234.65 2440.0 -4.58 1.2734.86 2450.0 -4.77 0.8533.34 2460.0 -4.67 1.1634.15 2470.0 -4.75 1.1333.51 2480.0 -4.60 0.7434.64 2490.0 -4.68 1.0234.04 2500.0 -4.70 0.9733.91 5150.0 -4.94 1.5732.031.57 5250.0 -4.72 2.0733.742.07 5350.0 -4.86 1.6132.691.61 5550.0 -4.66 1.7234.211.72 5750.0 -4.53 1.5135.231.51 5850.0 -4.65 1.4434.311.44 深圳市亿圣邦科技有限公司第 5 页 WIFI有源测试 频段 1611 B-TRP-11MBps 14.2614.6414.56 B-TIS-11MBps -81.54-81.09-81.24 G-TRP-54MBps11.2611.5711.82 G-TIS-54MBps-70.34-70.5970.71 N-TRP-MCS711.4811.6711.93 N-TIS-MCS7-64.48-64.79-65.05 频段 36149165 A-TRP-54MBps 10.2910.1810.57 A-TIS-54MBps -69.46-69.57-69.42 深圳市亿圣邦科技有限公司第 6 页 GPStest 深圳市亿圣邦科技有限公司第 7 页 6.AntennaDimensions(unit:mm) 深圳市亿圣邦科技有限公司第 8 页 4GMAINAntenna(6812HV1) 1.ExplanationofProductnumber: SLK-PNE-6812HV1-L-85IV-B 12345 ProductCode: (1)Customer: PNE: 普耐尔 (2)Project: 6812HV1:SLK-6812HV1(4GMAINantenna) (3)WeldingPosition L:Left (4)CableLength: 85IV:85*0.81MM四代端子 (5)CableColor B:Black 2.Features *Stableandreliableinperformances *Compactsize *RoHScompliance 深圳市亿圣邦科技有限公司第 9 页 3.Description Holybond’sFPCantennaseriesarespeciallydesignedfor4Gapplications. BasedonHolybond’sproprietarydesignandprocesses,thisFPCantennahas excellentstabilityandsensitivitytoconsistentlyprovidehighsignalreception efficiency. 4.ElectricalSpecifications 4-1 CharacteristicsSpecificationsUnit OutlineDimensions 68.66x11.51x0.12 mm Bandwidth(under-10dBreturnloss) 130minMHz VSWR 5max 4-2 VSWRS11 深圳市亿圣邦科技有限公司第 10 页 4-3.2G/3G/4GAntennaTRP/TIS 2G频段 LTE-LLTE-MLTE-RTIS 增益(dbi) GSM850 27.1126.8326.59-102.360.8 GSM900 26.8626.7526.48-102.450.9 GSM1800 24.0824.2124.37-102.261.1 GSM1900 24.2524.4724.38-102.191.2 3G频段 LTE-LLTE-MLTE-RTIS 增益(dbi) WCDMA-B1 19.6419.7919.82-103.381.1 WCDMA-B8 17.0216.8217.13-102.560.9 4G频段 LTE-LLTE-MLTE-RTIS 增益(dbi) LTE-1 19.6519.2719.02-91.971.1 LTE-3 19.0119.0319.3-921 LTE-4 19.2819.1519.5-90.790.8 LTE-7 17.8917.4917.35-88.271.6 LTE-66 19.5919.1519.49-89.671 深圳市亿圣邦科技有限公司第 11 页 5.AntennaDimensions(unit:mm) 深圳市亿圣邦科技有限公司第 12 页 4GAUXAntenna(2004) 1.ExplanationofProductnumber: SLK-PNE-2004-L-85IV-B 12345 ProductCode: (1)Customer: PNE: 普耐尔 (2)Project: 2004:SLK-2004(4GAUXantenna) (3)WeldingPosition L:Left (4)CableLength: 85IV:85*0.81MM 四代端子 (5)CableColor B:Black 2.Features *Stableandreliableinperformances *Compactsize *RoHScompliance 深圳市亿圣邦科技有限公司第 13 页 3.Description Holybond’sFPCantennaseriesarespeciallydesignedfor4Gapplications. BasedonHolybond’sproprietarydesignandprocesses,thisFPCantennahas excellentstabilityandsensitivitytoconsistentlyprovidehighsignalreception efficiency. 4.ElectricalSpecifications 4-1 CharacteristicsSpecificationsUnit OutlineDimensions 20x4x0.12 mm Bandwidth(under-10dBreturnloss) 130minMHz VSWR 5max 4-2 VSWRS11 深圳市亿圣邦科技有限公司第 14 页 5.AntennaDimensions(unit:mm) 深圳市亿圣邦科技有限公司第 15 页 6.AntennaPicture 如图所示: 1.在主板屏蔽罩 贴四块导电海绵 与屏接地处理 如图所示: 1.主板底部环境 处理,主板漏铜 区贴8块导电海 绵与底壳接地处 理 深圳市亿圣邦科技有限公司第 16 页 4G 分集天线 WIFI/GPS天线 4G 主天线

RF Exposure Info

SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262. 6 CALIBRATION MEASUREMENT RESULTS 6.1 RETURN LOSS AND IMPEDANCE IN HEAD LIQUID Frequency (MHz) Return Loss (dB) Requirement (dB) Impedance 2450 -26.03-20 46.3  + 3.2 j 6.2 RETURN LOSS AND IMPEDANCE IN BODY LIQUID Frequency (MHz) Return Loss (dB) Requirement (dB) Impedance 2450 -32.76-20 48.7  + 1.9 j 6.3 MECHANICAL DIMENSIONS Frequency MHz L mm h mm d mm required measured required measured required measured 750 176.0 ±1 %. 100.0 ±1 %. 6.35 ±1 %. 835 161.0 ±1 %. 89.8 ±1 %. 3.6 ±1 %. Page: 6/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. ..MVGB.A 0 1 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262. 900 149.0 ±1 %. 83.3 ±1 %. 3.6 ±1 %. 1450 89.1 ±1 %. 51.7 ±1 %. 3.6 ±1 %. 1500 80.5 ±1 %. 50.0 ±1 %. 3.6 ±1 %. 1640 79.0 ±1 %. 45.7 ±1 %. 3.6 ±1 %. 1750 75.2 ±1 %. 42.9 ±1 %. 3.6 ±1 %. 1800 72.0 ±1 %. 41.7 ±1 %. 3.6 ±1 %. 1900 68.0 ±1 %. 39.5 ±1 %. 3.6 ±1 %. 1950 66.3 ±1 %. 38.5 ±1 %. 3.6 ±1 %. 2000 64.5 ±1 %. 37.5 ±1 %. 3.6 ±1 %. 2100 61.0 ±1 %. 35.7 ±1 %. 3.6 ±1 %. 2300 55.5 ±1 %. 32.6 ±1 %. 3.6 ±1 %. 2450 51.5 ±1 %. PASS 30.4 ±1 %. PASS 3.6 ±1 %. PASS 2600 48.5 ±1 %. 28.8 ±1 %. 3.6 ±1 %. 3000 41.5 ±1 %. 25.0 ±1 %. 3.6 ±1 %. 3500 37.0±1 %. 26.4 ±1 %. 3.6 ±1 %. 3700 34.7±1 %. 26.4 ±1 %. 3.6 ±1 %. 7 VALIDATION MEASUREMENT The IEEE Std. 1528, OET 65 Bulletin C and CEI/IEC 62209 standards state that the system validation measurements must be performed using a reference dipole meeting the fore mentioned return loss and mechanical dimension requirements. The validation measurement must be performed against a liquid filled flat phantom, with the phantom constructed as outlined in the fore mentioned standards. Per the standards, the dipole shall be positioned below the bottom of the phantom, with the dipole length centered and parallel to the longest dimension of the flat phantom, with the top surface of the dipole at the described distance from the bottom surface of the phantom. 7.1 HEAD LIQUID MEASUREMENT Frequency MHz Relative permittivity ( r ’) Conductivity (σ) S/m required measured required measured 750 41.9 ±5 % 0.89 ±5 % 835 41.5 ±5 % 0.90 ±5 % 900 41.5 ±5 % 0.97 ±5 % 1450 40.5 ±5 % 1.20 ±5 % 1500 40.4 ±5 % 1.23 ±5 % 1640 40.2 ±5 % 1.31 ±5 % 1750 40.1 ±5 % 1.37 ±5 % 1800 40.0 ±5 % 1.40 ±5 % 1900 40.0 ±5 % 1.40 ±5 % 1950 40.0 ±5 % 1.40 ±5 % 2000 40.0 ±5 % 1.40 ±5 % Page: 7/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. ..MVGB.A 0 1 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262. 2100 39.8 ±5 % 1.49 ±5 % 2300 39.5 ±5 % 1.67 ±5 % 2450 39.2 ±5 % PASS 1.80 ±5 % PASS 2600 39.0 ±5 % 1.96 ±5 % 3000 38.5 ±5 % 2.40 ±5 % 3500 37.9 ±5 % 2.91 ±5 % 7.2 SAR MEASUREMENT RESULT WITH HEAD LIQUID The IEEE Std. 1528 and CEI/IEC 62209 standards state that the system validation measurements should produce the SAR values shown below (for phantom thickness of 2 mm), within the uncertainty for the system validation. All SAR values are normalized to 1 W forward power. In bracket, the measured SAR is given with the used input power. Software OPENSAR V4 Phantom SN 20/09 SAM71 Probe SN 18/11 EPG122 Liquid Head Liquid Values: eps’ : 39.0 sigma : 1.77 Distance between dipole center and liquid 10.0 mm Area scan resolution dx=8mm/dy=8mm Zoon Scan Resolution dx=8mm/dy=8m/dz=5mm Frequency 2450 MHz Input power 20 dBm Liquid Temperature 21 °C Lab Temperature 21 °C Lab Humidity 45 % Frequency MHz 1 g SAR (W/kg/W) 10 g SAR (W/kg/W) required measured required measured 750 8.49 5.55 835 9.56 6.22 900 10.9 6.99 1450 29 16 1500 30.5 16.8 1640 34.2 18.4 1750 36.4 19.3 1800 38.4 20.1 1900 39.7 20.5 1950 40.5 20.9 2000 41.1 21.1 2100 43…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jonathan Ibarah
[email protected]Fax: 3054695332

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR,RIVERSIDE, · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from DAMASCO TRADING LLC

2BQHT-TAB-T537-10

Tablet PC

Dec 10, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Tablet PC - FCC ID 2BQHT-TAB-T104-6 - DAMASCO TRADING LLC
2BQHT-TAB-T104-6

Tablet PC

Dec 08, 2025

Equipment Class

PCB - PCS Licensed Transmitter
Tablet PC - FCC ID 2BQHT-TAB-T126-8 - DAMASCO TRADING LLC
2BQHT-TAB-T126-8

Tablet PC

Dec 05, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Tablet PC - FCC ID 2BQHT-TAB-T101-4 - DAMASCO TRADING LLC
2BQHT-TAB-T101-4

Tablet PC

Dec 05, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Tablet PC - FCC ID 2BQHT-TAB-T863-3 - DAMASCO TRADING LLC
2BQHT-TAB-T863-3

Tablet PC

Dec 04, 2025

Equipment Class

DTS - Digital Transmission System