User Manual Draft - Earbuds - Charging case -Charging Cable Setup Instruction: 1. Open the earbuds case and keep the earbuds inside. 2. Press and hold the paring button until the light starts pulsing. 3. Go to Bluetooth settings on your device and make sure the Bluetooth is on. 4. Tape “Earbuds” and connect. EMC Compliance Important: This product has demonstrated EMC compliance under conditions that included the use of compliant peripheral devices and shielded cables between system components. It is important that you use compliant peripheral devices and shielded cables between system components to reduce the possibility of causing interference to radios, televisions, and other electronic devices. United States Federal Communications Commission (FCC) Regulatory Compliance FCC ID: Left earbud: A4RG1007 Right earbud: A4RG1008 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this product not authorized by the manufacture could void the electromagnetic compatibility (EMC) and wireless compliance and negate your authority to operate the product. Model Number: G1007, G1008, G1013 Responsible Party: Google LLC, 1600 Amphitheatre Parkway, Mountain View, CA 94043. For help, please use the link below: https://support.google.com/googlepixelbuds#topic=7544331 Radio Frequency Exposure This device meets the U.S. Federal Communications Commission's (FCC) requirements for exposure to radio waves and is designed and manufactured not to exceed the FCC's emission limits for exposure to radiofrequency (RF) energy. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operating in conjunction with any other antenna or transmitter.
1 1600 Amphitheatre Parkway Mountain View, CA 94043 USA Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 December 17, 2019 Subject: Request for Confidentiality FCC ID: A4RG1007 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 C.F.R. §§ 0.457, 0.459), we request that the Commission withhold the following attachments as confidential documents from public disclosure indefinitely. ● Schematic Diagram ● Block Diagram ● Theory of Operation (Operational and Technical Descriptions) In support of this request, we provide the following information: 1. Identification of the specific information for which confidential treatment is sought (§ 0.459(b)(1)): We request that all of the information contained in the above-referenced exhibits to the certification application be withheld from routine public disclosure. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission (§ 0.459(b)(2)): The material is being submitted in connection with our certification application for the above-captioned FCC ID. 3. Explanation of the degree to which the information is commercial, or financial or contains a trade secret or is privileged (§ 0.459(b)(3)): The market for the technology that is the subject of the certification application is highly competitive, with numerous companies competing for the business of potential customers. Were competitors to become aware of the facts set forth in the above-referenced exhibits to the application at this time, it could have an adverse impact on our competitive standing and deprive us of the marketplace benefit we otherwise might achieve by virtue of having the product available before other competitors. If any of the information for which confidential treatment is sought was made publicly available, competitors could reasonably determine the scope and status of our activities. 4. Explanation of the degree to which the information concerns a service that is competitive (§ 0.459(b)(4)): The technology that is the subject of the certification application is subject to intense competition from other manufacturers and service providers that are developing competing services and technology. 5. Explanation of how disclosure of the information could result in substantial competitive harm (§ 0.459(b)(5)): As noted above, were our competitors to become aware of the facts set forth in the above- referenced exhibits to the application, it could have an adverse impact on our competitive standing and 2 deprive us of the marketplace benefit we otherwise would achieve by virtue of having the product available before other providers. 6. Identification of any measures taken by the requesting party to prevent unauthorized disclosure (§ 0.459(b)(6)): The information contained in the above-referenced exhibits to the certification application has been strictly controlled by us, with distribution limited to internal use only and for the specific purpose of conducting research, development, and testing of the technology. 7. Identification of whether the information is available to the public and the extent of any previous disclosures of the information to any third parties (§ 0.459(b)(7)): The information that we request be maintained as confidential is not available publicly. The information has been protected and kept confidential by limiting external contacts to privileged and confidential communications. 8. Justification of the period during which the submitting party asserts that material should not be available for public disclosure (§ 0.459(b)(8)): Given the competitive nature of the marketplace, any disclosure that we have developed the technology discussed in the above-referenced exhibits to the certification application would harm our competitive position. The information subject to this request for confidentiality should not be made available for public disclosure at any time. In addition, pursuant to Public Notice DA 04-1705, and in order to comply with the marketing regulations in 47 C.F.R. §2.803 and the importation rules in 47 C.F.R. §2.1204 while ensuring that business-sensitive information remains confidential until the actual marketing of newly authorized devices, we also request that the Commission grant temporary confidential treatment and not release the following attachments for routine public disclosure until 180 days after the grant date. ● External Photos ● Internal Photos ● Test Setup Photos ● User Manual It is our understanding that test measurement reports and correspondence during the certification review process cannot be granted confidential treatment, and such information will be available for public review once the grant of equipment authorization is issued. Sincerely yours, ___________________________ Kevin Li Regulatory Compliance Program Manager Google LLC 1600 Amphitheatre Parkway Mountain View, CA 94043 T: 650-253-0000 E: [email protected]
1600 Amphitheatre Parkway Mountain View, CA 94043 USA 1 Date: December 17, 2019 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: A4RG1007 To Whom It May Concern: I, the undersigned, hereby authorize Sporton International Inc. (Sporton) to act on Google LLC’s (Google) behalf in all manners relating to the above-captioned application for equipment authorization, including signing of all documents relating to this matter. Any and all acts carried out by Sporton on Google’s behalf shall have the same effect as acts of Google’s own. I, the undersigned, hereby certify that Google is not subject to a denial of federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 853(a). In authorizing Sporton as Google’s representative, Google recognizes that it is still responsible for: a) complying with the relevant provisions of the certification program; b) making all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) making claims regarding certification only in respect of the scope for which certification has been granted; d) not using the product certification in such a manner as to bring Sporton into disrepute and not making any statement regarding the product certification that Sporton may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinuing the use of all advertising matter that contains any reference thereto and return any certification documents as required by Sporton; f) using the certification only to indicate that the products are certified as being in conformity with specified standards; 1600 Amphitheatre Parkway Mountain View, CA 94043 USA 2 g) endeavoring to ensure that no certificate or report or any part thereof is used in a misleading manner; h) ensuring that any reference to the product certification in communication media such as documents, brochures, or advertising, complies with Sporton’s requirements; i) keeping a record of all complaints made known to Google relating to the product’s compliance with the requirements of the relevant standard and making these records available to the applicable authorities when requested; j) taking appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; and k) documenting the actions taken. This authorization is valid until further written notice from Google. Sincerely Yours, ______________________________ Kevin Li Regulatory Compliance Program Manager Google LLC 1600 Amphitheatre Parkway Mountain View, CA 94043 T: 650-253-0000 E: [email protected]
PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 1 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 1. External Photograph of EUT PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 2 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 3 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 4 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 5 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 6 of 14 FAX : 886-3-328-4978 Issued Date : Dec. 03, 2019 Report Version : 01 720510
Note: The devices are too small to accommodate the FCC ID and also too small for the 15.19 statement. For this reason, the FCC ID and 15.19 statement will be on the packaging as shown above and also in the user manual. Model Number: G1007, G1008 FCC ID: A4RG1007, A4RG1008 Made in China This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 1 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 Internal Photograph of EUT PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 2 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 3 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 4 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 5 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP921201-03 Model Name: G1007 TEL : 886-3-327-3456 Page Number : 6 of 6 FAX : 886-3-328-4978 Issued Date : Dec. 24, 2019 Report Version : 01 ─────THE END──── 720510
TEL : 886-3-327-3456 Page 1 of 20 FAX : 886-3-328-4978 Issued Date : Dec. 13, 2019 Form version: 181113 FCC SAR TEST REPORT Report No. : FA921201-03 FCC SAR TEST REPORT FCC ID : A4RG1007 Equipment : Wireless Earphone Model Name : G1007 Applicant : Google LLC 1600 Amphitheatre Parkway, Mountain View, California, 94043 USA Standard : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C95.1-1992 IEEE 1528-2013 The product was received on Sep. 23, 2019 and testing was started from Oct. 01, 2019 and completed on Oct. 01, 2019. We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any agency of government. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.) Approved by: Cona Huang / Deputy Manager TEL : 886-3-327-3456 Page 2 of 20 FAX : 886-3-328-4978 Issued Date : Dec. 13, 2019 Form version: 181113 FCC SAR TEST REPORT Report No. : FA921201-03 Table of Contents 1. Statement of Compliance ............................................................................................................................................. 4 2. Guidance Applied .......................................................................................................................................................... 4 3. Equipment Under Test (EUT) Information ................................................................................................................... 4 3.1 General Information ............................................................................................................................................... 4 4. RF Exposure Limits....................................................................................................................................................... 5 4.1 Uncontrolled Environment ...................................................................................................................................... 5 4.2 Controlled Environment .......................................................................................................................................... 5 5. Specific Absorption Rate (SAR) ................................................................................................................................... 6 5.1 Introduction ............................................................................................................................................................ 6 5.2 SAR Definition ........................................................................................................................................................ 6 6. System Description and Setup .................................................................................................................................... 7 6.1 E-Field Probe ......................................................................................................................................................... 8 6.2 Data Acquisition Electronics (DAE) ........................................................................................................................ 8 6.3 Phantom ................................................................................................................................................................. 9 6.4 Device Holder........................................................................................................................................................10 7. Measurement Procedures ...........................................................................................................................................11 7.1 Spatial Peak SAR Evaluation ................................................................................................................................ 11 7.2 Power Reference Measurement............................................................................................................................12 7.3 Area Scan .............................................................................................................................................................12 7.4 Zoom Scan ............................................................................................................................................................13 7.5 Volume Scan Procedures ......................................................................................................................................13 7.6 Power Drift Monitoring ...........................................................................................................................................13 8. Test Equipment List .....................................................................................................................................................14 9. System Verification ......................................................................................................................................................15 9.1 Tissue Simulating Liquids ......................................................................................................................................15 9.2 Tissue Verification .................................................................................................................................................16 9.3 System Performance Check Results .....................................................................................................................1…
Text truncated - open the document above for the full version.
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2019/10/1 System Check_Head_2450MHz DUT: D2450V2-929 Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450_191001 Medium parameters used : f = 2450 MHz; σ = 1.789 S/m; ε r = 39.226; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: EX3DV4 - SN7306; ConvF(7.48, 7.48, 7.48) @ 2450 MHz; Calibrated: 2019/7/22 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2019/5/21 - Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 1131 - Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450) Pin=250mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 25.8 W/kg Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 116.7 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 29.1 W/kg SAR(1 g) = 13.9 W/kg; SAR(10 g) = 6.38 W/kg Maximum value of SAR (measured) = 23.2 W/kg 0 dB = 23.2 W/kg = 13.65 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2019/10/1 #01_Bluetooth_1Mbps_Front_0mm_Ch00 Communication System: Bluetooth; Frequency: 2402 MHz;Duty Cycle: 1:1.307 Medium: HSL_2450_191001 Medium parameters used: f = 2402 MHz; σ = 1.744 S/m; ε r = 39.299; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: EX3DV4 - SN7306; ConvF(7.48, 7.48, 7.48) @ 2402 MHz; Calibrated: 2019/7/22 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2019/5/21 - Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 1131 - Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470) Area Scan (41x41x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.54 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 17.28 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 3.42 W/kg SAR(1 g) = 0.697 W/kg; SAR(10 g) = 0.265 W/kg Maximum value of SAR (measured) = 1.97 W/kg 0 dB = 1.54 W/kg = 1.88 dBW/kg
In Col aboratio wi ~TTL s P e a g CALIBRATION lABORATORY Add: No.SI Xueyuan Road, Haidian District, Beijing, 100191, China Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Client Sporton Certificate No: 219-60059 CALIBRATION CERTIFICATE Object D2450V2 - SN: 929 Calibration Procedure(s) FF-211-003-01 Calibration Procedures for dipole validation kits Calibration date: March 6, 2019 This calibration Certificate documents the traceability to national standards, which realize the physical units of measurements(SI). The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate. All calibrations have been conducted in the closed laboratory facility: environment temperature(22±3)°C and humidity<70%. Calibration Equipment used (M&TE critical for calibration) Primary Standards ID# Cal Date(Calibrated by, Certificate No.) Scheduled Calibration Power Meter NRP2 106277 20-Aug-18 (CTIL, No.J18X06862) Aug-19 Power sensor NRP8S 104291 20-Aug-18 (CTIL, No.J18X06862) Aug-19 Reference Probe EX3DV4 SN 3617 31-Jan-19(SPEAG,No.EX3-3617 _Jan19) Jan-20 DAE4 SN 1331 06-Feb-19(SPEAG,No.DAE4-1331_Feb19) Feb-20 Secondary Standards ID# Cal Date(Calibrated by, Certificate No.) Scheduled Calibration Signal Generator E4438C MY49071430 23-Jan-19 (CTTL, No.J19X00336) Jan-20 NetworkAnalyzer E5071 C MY46110673 24-Jan-19 (CTTL, No.J19X00547) Jan-20 Name Function Si§lnature Calibrated by: Zhao Jing SAR Test Engineer ,,·-"{ ·t( Reviewed by: Lin Hao SAR Test Engineer .~~ "7~·-.. "lfWt-· ~;L , . Approved by: Qi Dianyuan SAR Project Leader ----~~ Issued: March 8, 2019 This calibration certificate shall not be reproduced except in full without written approval of the laboratory. Certificate No: Zl 9-60059 Page I of8 In Col abofatio wi ~TTLspeag CAUBRADON lABORA.TORV Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Glossary: TSL ConvF N/A tissue simulating liquid sensitivity in TSL / NORMx, y,z not applicable or not measured Calibration is Performed According to the Following Standards: a) IEEE Std 1528-2013, "IEEE Recommended Practice for Determining the Peak Spatial-Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques", June 2013 b) IEC 62209-1, "Measurement procedure for assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Part 1: Device used next to the ear (Frequency range of 300MHz to 6GHz)", July 2016 c) IEC 62209-2, "Procedure to measure the Specific Absorption Rate (SAR) For wireless communication devices used in close proximity to the human body (frequency range of 30MHz to 6GHz)", March 2010 d) KDB865664, SAR Measurement Requirements for 100 MHz to 6 GHz Additional Documentation: e) DASY 4/5 System Handbook Methods Applied and Interpretation of Parameters: • Measurement Conditions: Further details are available from the Validation Report at the end of the certificate. All figures stated in the certificate are valid at the frequency indicated. • Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed point exactly below the center marking of the flat phantom section, with the arms oriented parallel to the body axis. • Feed Point Impedance and Return Loss: These parameters are measured with the dipole positioned under the liquid filled phantom. The impedance stated is transformed from the measurement at the SMA connector to the feed point. The Return Loss ensures low reflected power. No uncertainty required. • Electrical Delay: One-way delay between the SMA connector and the antenna feed point. No uncertainty required. • SAR measured: SAR measured at the stated antenna input power. • SAR normalized: SAR as measured, normalized to an input power of 1 Wat the antenna connector. • SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the nominal SAR result. The reported uncertainty of measurement is stated as the standard uncertainty of Measurement multiplied by the coverage factor k=2, which for a normal distribution Corresponds to a coverage probability of approximately 95%. Certificate No: Zl 9-60059 Page 2 of8 ~; ~TTL In Col aboratio wi s p e a g CAUBRADON LABORATORY Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Measurement Conditions D f f ASY system con 1gurat1on, as ar as no 01ven on oaoe t . DASY Version DASY52 Extrapolation Advanced Extrapolation Phantom Triple Flat Phantom 5.1 C Distance Dipole Center -TSL 10mm Zoom Scan Resolution dx, dy, dz = 5 mm Frequency 2450 MHz ± 1 MHz Head TSL parameters Th f II . t d I I f e o owmq oarame ers an ca cu a ions were aoo ,e . r d 52.10.2.1495 with Spacer Temperature Permittivity Conductivity Nominal Head TSL parameters 22.0 °C 39.2 1.80 mho/m Measured Head TSL parameters (22.0 ± 0.2) °C 39.1±6% 1.85 mho/m ±6 % Head TSL temperature change during test <1.0 °C ---- ---- SAR result with Head TSL SAR averaged over 1 cm 3 (1 g) of Head TSL Condition SAR measured 250 mW input power 13.2 W/kg SAR for nominal Head TSL parameters normalized to 1W 52.1 W/kg ± 18.8 % (k=2) SAR averaged over 10 cm 3 (10 g) of Head TSL Condition SAR measured 250 mW input power 6.08 W/kg SAR for nominal Head TSL parameters normalized to 1W 24.1 W/kg ± 18.7 % (k=2) Body TSL parameters Th f II . t d I I f e o owmq parame ers an ca cu a ions were app ,e . r d Temperature Permittivity Conductivity Nominal Body TSL parameters 22.0 °C 52.7 1.95 mho/m Measured Body TSL parameters (22.0 ± 0.2) °C 52.2 ± 6 % 2 .00 mho/m ± 6 % Body TSL temperature change during test <1.0 °C -------- SAR It "th B d TSL resu WI 0 IY SAR averaged over 1 cm 3 (1 g) of B…
Text truncated - open the document above for the full version.
TEL : 886-3-327-3456 Page Number : 1 of 32 FAX : 886-3-328-4978 Issued Date : Dec. 02, 2019 Report Template No.: BU5-FR15CBT4.0 Version 2.4 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR921201-03B FCC RADIO TEST REPORT FCC ID A4RG1007 Equipment : Wireless Earphone Model Name : G1007 Applicant : Google LLC 1600 Amphitheatre Parkway, Mountain View, California, 94043 USA Standard : FCC Part 15 Subpart C §15.247 The product was received on Mar. 04, 2019 and testing was started from Aug. 16, 2019 and completed on Nov. 25, 2019. We, SPORTON INTERNATIONAL INC., EMC & Wireless Communications Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any agency of government. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.) TEL : 886-3-327-3456 Page Number : 2 of 32 FAX : 886-3-328-4978 Issued Date : Dec. 02, 2019 Report Template No.: BU5-FR15CBT4.0 Version 2.4 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR921201-03B Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ................................................................................................................................... 5 1.1 Product Feature of Equipment Under Test ..............................…
Text truncated - open the document above for the full version.
No. 52, Huaya 1st Rd., Guishan Dist., · Taoyuan · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.00 mW |
Phone
Equipment Class
UWB - Ultra Wideband TransmitterPhone
Equipment Class
TNB - Licensed Non-Broadcast Station TransmitterPhone
Equipment Class
6CD - 15E 6 GHz Low Power Dual ClientPhone
Equipment Class
PCE - PCS Licensed Transmitter held to earPhone
Equipment Class
UWB - Ultra Wideband Transmitter