Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 650253-0000main Google.com FederalCommunicationsCommission 7435OaklandMillsRoad ColumbiaMD21046 May17,2024 Subject:CertificationdesignatingaU.S.agentforserviceofprocesspursuanttoPart2.911(d)(7) FCCID:A4RGGH2X FRN:0020499539 Towhomitmayconcern, GoogleLLC(“theapplicant”)designatesitselfastheagentforserviceofprocess.Hereby,we acknowledgetheapplicant’sconsentandthedesignatedagent’sobligationtoacceptserviceof process;wealsoacknowledgetheapplicant’sacceptancetomaintainanagentfornolessthanone yearafterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. Sincerelyyours, ______________________________ SherryLu RFComplianceProgramManager Email:[email protected] GoogleLLC 1600AmphitheatreParkway MountainView,CA94043
GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 650253-0000main Google.com FederalCommunicationsCommission 7435OaklandMillsRoad ColumbiaMD21046 May17,2024 Subject:Certificationsconcerning“covered”equipmentpursuanttoPart2.911(d)(5)(i)and(ii) FCCID:A4RGGH2X Towhomitmayconcern, GoogleLLC(“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903 oftheFCCrules.Theapplicantalsocertifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredListasanentityproducing“covered”equipment,andis notanaffiliateorsubsidiaryofanentityidentifiedontheCoveredList. Sincerelyyours, ______________________________ SherryLu RFComplianceProgramManager Email:[email protected] GoogleLLC 1600AmphitheatreParkway MountainView,CA94043
GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 650253-0000main Google.com FederalCommunicationsCommission 7435OaklandMillsRoad ColumbiaMD21046 May17,2024 Subject:RequestforConfidentiality FCCID:A4RGGH2X ToWhomItMayConcern: PursuanttotheprovisionsofSections0.457and0.459oftheCommission’srules(47C.F.R.§§0.457,0.459),werequest thattheCommissionwithholdthefollowingattachmentsasconfidentialdocumentsfrompublicdisclosureindefinitely. ● SchematicDiagram ● BlockDiagram ● TheoryofOperation(OperationalandTechnicalDescriptions) ● TuneUpProcedure Insupportofthisrequest,weprovidethefollowinginformation: 1.Identificationofthespecificinformationforwhichconfidentialtreatmentissought(§0.459(b)(1)):We requestthatalloftheinformationcontainedintheabove-referencedexhibitstothecertificationapplicationbe withheldfromroutinepublicdisclosure. 2.IdentificationoftheCommissionproceedinginwhichtheinformationwassubmittedoradescriptionofthe circumstancesgivingrisetothesubmission(§0.459(b)(2)):Thematerialisbeingsubmittedinconnectionwith ourcertificationapplicationfortheabove-captionedFCCID. 3.Explanationofthedegreetowhichtheinformationiscommercial,orfinancialorcontainsatradesecretor isprivileged(§0.459(b)(3)):Themarketforthetechnologythatisthesubjectofthecertificationapplicationis highlycompetitive,withnumerouscompaniescompetingforthebusinessofpotentialcustomers.Were competitorstobecomeawareofthefactssetforthintheabove-referencedexhibitstotheapplicationatthistime, itcouldhaveanadverseimpactonourcompetitivestandinganddepriveusofthemarketplacebenefitwe otherwisemightachievebyvirtueofhavingtheproductavailablebeforeothercompetitors.Ifanyofthe informationforwhichconfidentialtreatmentissoughtwasmadepubliclyavailable,competitorscouldreasonably determinethescopeandstatusofouractivities. 4.Explanationofthedegreetowhichtheinformationconcernsaservicethatiscompetitive(§0.459(b)(4)): Thetechnologythatisthesubjectofthecertificationapplicationissubjecttointensecompetitionfromother manufacturersandserviceprovidersthataredevelopingcompetingservicesandtechnology. 5.Explanationofhowdisclosureoftheinformationcouldresultinsubstantialcompetitiveharm(§ 0.459(b)(5)):Asnotedabove,wereourcompetitorstobecomeawareofthefactssetforthinthe above-referencedexhibitstotheapplication,itcouldhaveanadverseimpactonourcompetitivestandingand depriveusofthemarketplacebenefitweotherwisewouldachievebyvirtueofhavingtheproductavailablebefore otherproviders. 6.Identificationofanymeasurestakenbytherequestingpartytopreventunauthorizeddisclosure(§ 0.459(b)(6)):Theinformationcontainedintheabove-referencedexhibitstothecertificationapplicationhasbeen strictlycontrolledbyus,withdistributionlimitedtointernaluseonlyandforthespecificpurposeofconducting research,development,andtestingofthetechnology. 7.Identificationofwhethertheinformationisavailabletothepublicandtheextentofanyprevious disclosuresoftheinformationtoanythirdparties(§0.459(b)(7)):Theinformationthatwerequestbe maintainedasconfidentialisnotavailablepublicly.Theinformationhasbeenprotectedandkeptconfidentialby limitingexternalcontactstoprivilegedandconfidentialcommunications. 8.Justificationoftheperiodduringwhichthesubmittingpartyassertsthatmaterialshouldnotbeavailable forpublicdisclosure(§0.459(b)(8)):Giventhecompetitivenatureofthemarketplace,anydisclosurethatwe havedevelopedthetechnologydiscussedintheabove-referencedexhibitstothecertificationapplicationwould harmourcompetitiveposition.Theinformationsubjecttothisrequestforconfidentialityshouldnotbemade availableforpublicdisclosureatanytime. Inaddition,pursuanttoPublicNoticeDA04-1705,andinordertocomplywiththemarketingregulationsin47C.F.R. §2.803andtheimportationrulesin47C.F.R.§2.1204whileensuringthatbusiness-sensitiveinformationremains confidentialuntiltheactualmarketingofnewlyauthorizeddevices,wealsorequestthattheCommissiongranttemporary confidentialtreatmentandnotreleasethefollowingattachmentsforroutinepublicdisclosureuntil180daysafterthegrant date. ● ExternalPhotos ● InternalPhotos ● TestSetupPhotos ● UserManual Itisourunderstandingthattestmeasurementreportsandcorrespondenceduringthecertificationreviewprocesscannotbe grantedconfidentialtreatment,andsuchinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerelyyours, ______________________________ SherryLu RFComplianceProgramManager GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 2
GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 650253-0000main Google.com Date:May17,2024 FederalCommunicationsCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 FCCID:A4RGGH2X ToWhomItMayConcern: I,theundersigned,herebyauthorizeSportonInternationalInc.toactonGoogleLLC’s(Google) behalfinallmannersrelatingtotheabove-captionedapplicationforequipmentauthorization, includingsigningofalldocumentsrelatingtothismatter.AnyandallactscarriedoutbySporton InternationalInc.onGoogle’sbehalfshallhavethesameeffectasactsofGoogle’sown. I,theundersigned,herebycertifythatGoogleisnotsubjecttoadenialoffederalbenefits, includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21 U.S.C.§853(a). InauthorizingSportonInternationalInc.asGoogle’srepresentative,Googlerecognizesthatitis stillresponsiblefor: a)complyingwiththerelevantprovisionsofthecertificationprogram; b)makingallnecessaryarrangementsfortheconductoftheevaluation,including provisionforexaminingdocumentationandaccesstoallareas,records(including internalauditreports)andpersonnelforthepurposesofevaluation(e.g.testing, inspection,assessment,surveillance,reassessment)andresolutionofcomplaints; c)makingclaimsregardingcertificationonlyinrespectofthescopeforwhich certificationhasbeengranted; d)notusingtheproductcertificationinsuchamannerastobringSporton InternationalInc.intodisreputeandnotmakinganystatementregardingthe productcertificationthatSportonInternationalInc.mayconsidermisleadingor unauthorized; e)uponsuspensionorcancellationofcertification,discontinuingtheuseofall advertisingmatterthatcontainsanyreferencetheretoandreturningany certificationdocumentsasrequiredbySportonInternationalInc.; f)usingthecertificationonlytoindicatethattheproductsarecertifiedasbeingin conformitywithspecifiedstandards; g)endeavoringtoensurethatnocertificateorreportoranypartthereofisusedina misleadingmanner; h)ensuringthatanyreferencetotheproductcertificationincommunicationmedia suchasdocuments,brochures,oradvertising,complieswithSportonInternational Inc.’srequirements; i)keepingarecordofallcomplaintsmadeknowntoGooglerelatingtothe product’scompliancewiththerequirementsoftherelevantstandardandmaking theserecordsavailabletotheapplicableauthoritieswhenrequested; j)takingappropriateactionwithrespecttosuchcomplaintsandanydeficiencies foundinproductsorservicesthataffectcompliancewiththerequirementsfor certification;and k)documentingtheactionstaken. ThisauthorizationisvaliduntilfurtherwrittennoticefromGoogle. Sincerelyyours, ______________________________ SherryLu RFComplianceProgramManager GoogleLLC 1600AmphitheatreParkway MountainView,CA94043 2
LabelingDeclaration FCCID:A4RGGH2X FCC§2.935Electroniclabelingofradiofrequencydevices. (a)Anyradiofrequencydeviceequippedwithanintegratedelectronicdisplayscreen,ora radiofrequencydevicewithoutanintegratedscreenthatcanonlyoperateinconjunctionwitha devicethathasanelectronicdisplayscreen,maydisplayontheelectronicdisplaytheFCC Identifier,anywarningstatements,orotherinformationthattheCommission’sruleswould otherwiserequiretobeshownonaphysicallabelattachedtothedevice. InformationOne-labelInManual FCCIDnumberYesNo 15.19Statement(“Thisdevicecomplieswithpart15of theFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmful interferenceand(2)thisdevicemustacceptany interferencereceived,includinginterferencethatmay causeundesiredoperation.”) NoYes ClassBDigitalDeviceusermanualstatementNoYes Cautiontotheuserthatchangesormodificationsnot expresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser’sauthoritytooperatethe equipment NoYes Imageofthee-labelscreenisprovidedbelow: Model:GGH2X UnitedStatesofAmerica FCCID:A4RGGH2X Thesatellitefeatureonthisdevicemust beturnedoffatalltimeswhileonboard anaircraftbyturningonairplanemode. Model:Model:GC15S UnitedStatesofAmerica FCCID:A4RGGH2X Thesatellitefeatureonthisdevicemust beturnedoffatalltimeswhileonboard anaircraftbyturningonairplanemode. (b)DevicesdisplayingtheirFCCIdentifier,warningstatements,orotherinformation electronicallymustmakethisinformationreadilyaccessibleontheelectronicdisplay.Usersmust beprovidedwithprominentinstructionsonhowtoaccesstheinformationintheoperating instructions,insertsinpackagingmaterial,orothereasilyaccessibleformatatthetimeof purchase.Theaccessinstructionsmayalsobeprovidedviatheproduct-relatedwebsite,ifsucha websiteexists;thepackagingmaterialmustprovidespecificinstructionsonhowtolocatethe websiteinformation,andacopyoftheseinstructionsmustbeincludedintheapplicationfor equipmentcertification. Theinstructiononhowtoaccesstheinformationisintheboxinthe Safety/Warranty/Regulatorybooklet,andintheonlineversionofthe Safety/Warranty/Regulatorybooklet: “Regulatoryinformation,certification,andcompliancemarkscanbefoundwiththe followingstepsfromtheHomescreen:Settings>Aboutphone>Regulatorylabels.” (c)DevicesdisplayingtheirFCCIdentifier,warningstatements,orotherinformation electronicallymustpermitaccesstotheinformationwithoutrequiringspecialcodes,accessories orpermissionsandtheaccesstothisinformationmustnotrequiremorethanthreestepsfromthe devicesettingmenu.Thenumberofstepsdoesnotincludethosestepsforuseofscreenlocks, passcodesorsimilarsecurityprotectiondesignedtocontroloveralldeviceaccess. Nospecialaccessoriesorsupplementalplug-insarerequiredtoaccesstheinformation. Toaccessthee-labelinformation,inthedevicefromtheHomescreen: Select:Settings>Aboutphone>Regulatorylabels (d)TheelectronicallydisplayedFCCIdentifier,warningstatements,orotherinformationmustbe displayedelectronicallyinamannerthatisclearlylegiblewithouttheaidofmagnification. Yes (e)Thenecessarylabelinformationmustbeprogrammedbytheresponsiblepartyandmustbe securedinsuchamannerthatthird-partiescannotmodifyit. Thee-labelinformationispre-programmedbythegrantee.Theusercannotmodifythe e-labelinformation. (f)DevicesdisplayingtheirFCCIdentifier,warningstatements,orotherinformation electronicallymustalsobelabeled,eitheronthedeviceoritspackaging,withtheFCCIdentifier orotherinformation(suchasamodelnumberandidentificationofawebpagethathoststhe relevantregulatoryinformation)thatpermitsthedevicestobeidentifiedatthetimeof importation,marketing,andsalesascomplyingwiththeFCC’sequipmentauthorization requirements.Devicescanbelabeledwithastick-onlabel,printingonthepackaging,alabelon aprotectivebag,orbysimilarmeans.Anyremovablelabelshallbeofatypeintendedtosurvive normalshippingandhandlingandmustonlyberemovedbythecustomerafterpurchase. TheFCCIDandHACdetailsarepresentontheproductpackaging. FCC§20.19(f)Labelinganddisclosurerequirementsforhearingaid-compatiblehandsets (1)Packagelabel.Forallhandsetmodelscertifiedtobehearingaid-compatible,manufacturers andserviceprovidersshallensurethatthehandset'spackagelabelstatesthatthehandsetis hearingaid-compatibleandthehandset'sactualconversationalgainwithandwithoutahearing aidifcertifiedusingatechnicalstandardwithvolumecontrolrequirements.Theactual conversationalgaindisplayedforusewithahearingaidshallbethelowestratingassignedto thehandsetforanycoveredairinterfaceorfrequencyband. Yes,theexteriorpackagingwillnotethatthedeviceishearingaidcompatibleandwill includetheconversationalgainswithandwithoutaid.Here’sanexample: FCCID:A4RGGH2X HearingAidCompatible ConversationalGain: 19dBw/aid&18dBw/oaidDA23-914
Date: 2024-02-21 System Check_Head_750MHz DUT: D750V3 - SN1012 Communication System: CW; Frequency: 750.000 MHz Medium: HSL_750_240221 Medium parameters used: f= 750.000 MHz; σ= 0.877 S/m; ε r = 42.9 Ambient Temperature: 23.8°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.65, 9.46, 11.18); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.423 W/kg; SAR (10g) = 0.282 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.05 dB SAR (1g) = 0.422 W/kg; SAR (8g) = 0.291 W/kg; SAR (10g) = 0.276 W/kg Smallest distance from peaks to all points 3 dB below = 19.6 mm Ratio of SAR at M2 to SAR at M1 = 89.6 % Date: 2024-02-22 System Check_Head_750MHz DUT: D750V3 - SN1012 Communication System: CW; Frequency: 750.000 MHz Medium: HSL_750_240222 Medium parameters used: f= 750.000 MHz; σ= 0.886 S/m; ε r = 43.0 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.65, 9.46, 11.18); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.429 W/kg; SAR (10g) = 0.286 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.04 dB SAR (1g) = 0.418 W/kg; SAR (8g) = 0.289 W/kg; SAR (10g) = 0.273 W/kg Smallest distance from peaks to all points 3 dB below = 20.4 mm Ratio of SAR at M2 to SAR at M1 = 90.1 % Date: 2024-02-23 System Check_Head_750MHz DUT: D750V3 - SN1012 Communication System: CW; Frequency: 750.000 MHz Medium: HSL_750_240223 Medium parameters used: f= 750.000 MHz; σ= 0.880 S/m; ε r = 42.9 Ambient Temperature: 23.7°C; Liquid Temperature: 22.7°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.65, 9.46, 11.18); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.423 W/kg; SAR (10g) = 0.281 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.02 dB SAR (1g) = 0.415 W/kg; SAR (8g) = 0.286 W/kg; SAR (10g) = 0.271 W/kg Smallest distance from peaks to all points 3 dB below = 20.4 mm Ratio of SAR at M2 to SAR at M1 = 89.9 % Date: 2024-02-24 System Check_Head_750MHz DUT: D750V3 - SN1012 Communication System: CW; Frequency: 750.000 MHz Medium: HSL_750_240224 Medium parameters used: f= 750.000 MHz; σ= 0.884 S/m; ε r = 42.8 Ambient Temperature: 23.8°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.65, 9.46, 11.18); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.415 W/kg; SAR (10g) = 0.276 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.01 dB SAR (1g) = 0.404 W/kg; SAR (8g) = 0.279 W/kg; SAR (10g) = 0.265 W/kg Smallest distance from peaks to all points 3 dB below = 21.3 mm Ratio of SAR at M2 to SAR at M1 = 89.3 % Date: 2024-02-25 System Check_Head_835MHz DUT: D835V2 - SN4d060 Communication System: CW; Frequency: 835.000 MHz Medium: HSL_835_240225 Medium parameters used: f= 835.000 MHz; σ= 0.920 S/m; ε r = 42.4 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.58, 9.16, 10.94); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.541 W/kg; SAR (10g) = 0.355 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.00 dB SAR (1g) = 0.533 W/kg; SAR (8g) = 0.366 W/kg; SAR (10g) = 0.346 W/kg Smallest distance from peaks to all points 3 dB below = 17.8 mm Ratio of SAR at M2 to SAR at M1 = 88.4 % Date: 2024-02-26 System Check_Head_835MHz DUT: D835V2 - SN4d060 Communication System: CW; Frequency: 835.000 MHz Medium: HSL_835_240226 Medium parameters used: f= 835.000 MHz; σ= 0.917 S/m; ε r = 42.7 Ambient Temperature: 23.1°C; Liquid Temperature: 22.1°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(9.58, 9.16, 10.94); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.540 W/kg; SAR (10g) = 0.355 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.01 dB SAR (1g) = 0.531 W/kg; SAR (8g) = 0.364 W/kg; SAR (10g) = 0.344 W/kg Smallest distance from peaks to all points 3 dB below = 17.8 mm Ratio of SAR at M2 to SAR at M1 = 88.3 % Date: 2024-02-27 System Check_Head_835MHz DUT: D835V2 - SN4d060 Communication System: CW; Frequency: 835.000 MHz Medium: HSL_835_240227 Medium parameters used: f= 835.000 MHz…
Text truncated - open the document above for the full version.
Date: 2024-03-16 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240316 Medium parameters used: f= 3700.000 MHz; σ= 3.06 S/m; ε r = 37.6 Ambient Temperature: 23.7°C; Liquid Temperature: 22.7°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.04 W/kg; SAR (10g) = 1.13 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = 0.00 dB SAR (1g) = 3.07 W/kg; SAR (8g) = 1.29 W/kg; SAR (10g) = 1.14 W/kg Smallest distance from peaks to all points 3 dB below = 8.0 mm Ratio of SAR at M2 to SAR at M1 = 75.5 % Date: 2024-03-18 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240318 Medium parameters used: f= 3700.000 MHz; σ= 3.14 S/m; ε r = 37.9 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.12 W/kg; SAR (10g) = 1.16 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = 0.00 dB SAR (1g) = 3.15 W/kg; SAR (8g) = 1.33 W/kg; SAR (10g) = 1.18 W/kg Smallest distance from peaks to all points 3 dB below = 8.0 mm Ratio of SAR at M2 to SAR at M1 = 75.4 % Date: 2024-03-20 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240320 Medium parameters used: f= 3700.000 MHz; σ= 3.10 S/m; ε r = 37.6 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.29 W/kg; SAR (10g) = 1.24 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = -0.06 dB SAR (1g) = 3.22 W/kg; SAR (8g) = 1.37 W/kg; SAR (10g) = 1.21 W/kg Smallest distance from peaks to all points 3 dB below = 8.3 mm Ratio of SAR at M2 to SAR at M1 = 76.1 % Date: 2024-03-22 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240322 Medium parameters used: f= 3700.000 MHz; σ= 3.10 S/m; ε r = 37.8 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.24 W/kg; SAR (10g) = 1.20 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = -0.00 dB SAR (1g) = 3.25 W/kg; SAR (8g) = 1.38 W/kg; SAR (10g) = 1.22 W/kg Smallest distance from peaks to all points 3 dB below = 8.0 mm Ratio of SAR at M2 to SAR at M1 = 76.4 % Date: 2024-03-23 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240323 Medium parameters used: f= 3700.000 MHz; σ= 3.09 S/m; ε r = 37.6 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.15 W/kg; SAR (10g) = 1.17 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = 0.01 dB SAR (1g) = 3.17 W/kg; SAR (8g) = 1.35 W/kg; SAR (10g) = 1.19 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 77.2 % Date: 2024-03-25 System Check_Head_3700MHz DUT: D3700V2 - SN1022 Communication System: CW; Frequency: 3700.000 MHz Medium: HSL_3700_240325 Medium parameters used: f= 3700.000 MHz; σ= 3.11 S/m; ε r = 37.7 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7692; ConvF(7.11, 6.91, 8.06); Calibrated: 2023-07-18 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1311; Calibrated: 2023-09-13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Serial: 1719; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.16 W/kg; SAR (10g) = 1.18 W/kg; Pin=17.0dBm/Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.4 mm Power Drift = 0.00 dB SAR (1g) = 3.20 W/kg; SAR (8g) = 1.36 W/kg; SAR (10g) = 1.20 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 77.2 % Date: 2024-03-01 System Check_Head_3900MHz DUT: D3900V2 - SN1017 Communication System: CW; Frequency: 3900.000 MHz Medium: HSL_3900_240301 Medium parameters used: f= 3900.000 MHz; σ= 3.36 S/m; ε r…
Text truncated - open the document above for the full version.
Date: 2024-02-27 System Check_Head_5800MHz DUT: D5GHzV2 - SN1128 Communication System: CW; Frequency: 5800.000 MHz Medium: HSL_5G_240227 Medium parameters used: f= 5800.000 MHz; σ= 5.29 S/m; ε r = 36.2 Ambient Temperature: 23.2°C; Liquid Temperature: 22.2°C DASY8 Configuration: - Probe: EX3DV4 - SN3925; ConvF(5.1, 5.1, 5.1); Calibrated: 2023-04-25 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn703; Calibrated: 2023-05-16 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.46 W/kg; SAR (10g) = 1.00 W/kg; Pin=17.0dBm/Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm Power Drift = 0.04 dB SAR (1g) = 3.71 W/kg; SAR (8g) = 1.23 W/kg; SAR (10g) = 1.06 W/kg Smallest distance from peaks to all points 3 dB below = 7.6 mm Ratio of SAR at M2 to SAR at M1 = 61.9 % Date: 2024-02-28 System Check_Head_5800MHz DUT: D5GHzV2 - SN1128 Communication System: CW; Frequency: 5800.000 MHz Medium: HSL_5G_240228 Medium parameters used: f= 5800.000 MHz; σ= 5.33 S/m; ε r = 34.6 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY8 Configuration: - Probe: EX3DV4 - SN3925; ConvF(5.1, 5.1, 5.1); Calibrated: 2023-04-25 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn703; Calibrated: 2023-05-16 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.51 W/kg; SAR (10g) = 1.01 W/kg; Pin=17.0dBm/Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm Power Drift = 0.01 dB SAR (1g) = 3.74 W/kg; SAR (8g) = 1.24 W/kg; SAR (10g) = 1.07 W/kg Smallest distance from peaks to all points 3 dB below = 7.6 mm Ratio of SAR at M2 to SAR at M1 = 61.8 % Date: 2024-02-29 System Check_Head_5800MHz DUT: D5GHzV2 - SN1128 Communication System: CW; Frequency: 5800.000 MHz Medium: HSL_5G_240229 Medium parameters used: f= 5800.000 MHz; σ= 5.32 S/m; ε r = 35.9 Ambient Temperature: 23.4°C; Liquid Temperature: 22.4°C DASY8 Configuration: - Probe: EX3DV4 - SN3925; ConvF(5.1, 5.1, 5.1); Calibrated: 2023-04-25 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn703; Calibrated: 2023-05-16 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.50 W/kg; SAR (10g) = 1.01 W/kg; Pin=17.0dBm/Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm Power Drift = 0.01 dB SAR (1g) = 3.73 W/kg; SAR (8g) = 1.24 W/kg; SAR (10g) = 1.07 W/kg Smallest distance from peaks to all points 3 dB below = 6.9 mm Ratio of SAR at M2 to SAR at M1 = 61.6 % Date: 2024-03-01 System Check_Head_5800MHz DUT: D5GHzV2 - SN1128 Communication System: CW; Frequency: 5800.000 MHz Medium: HSL_5G_240301 Medium parameters used: f= 5800.000 MHz; σ= 5.29 S/m; ε r = 35.5 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY8 Configuration: - Probe: EX3DV4 - SN3925; ConvF(5.1, 5.1, 5.1); Calibrated: 2023-04-25 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn703; Calibrated: 2023-05-16 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=17.0dBm/Area Scan (40.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 3.47 W/kg; SAR (10g) = 1.00 W/kg; Pin=17.0dBm/Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm Power Drift = 0.01 dB SAR (1g) = 3.70 W/kg; SAR (8g) = 1.23 W/kg; SAR (10g) = 1.06 W/kg Smallest distance from peaks to all points 3 dB below = 7.6 mm Ratio of SAR at M2 to SAR at M1 = 61.8 % Date: 2024-02-09 System Check_Head_6500MHz DUT: D6.5GHzV2 - SN1003 Communication System: CW; Frequency: 6500.000 MHz Medium: HSL_6G_240209 Medium parameters used: f= 6500.000 MHz; σ= 6.15 S/m; ε r = 34.8 Ambient Temperature: 23.4°C; Liquid Temperature: 22.4°C DASY8 Configuration: - Probe: EX3DV4 - SN3925; ConvF(5.35, 5.35, 5.35); Calibrated: 2023-04-25 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn703; Calibrated: 2023-05-16 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW, 0-- Pin=20.0dBm/Area Scan (51.0 mm x 85.0 mm): Measurement Grid: 8.5 mm x 8.5 mm SAR (1g) = 25.6 W/kg; SAR (10g) = 5.06 W/kg; Pin=20.0dBm/Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 3.4 mm x 3.4 mm x 1.4 mm Power Drift = 0.01…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 97.10 mW |
Phone
Equipment Class
UWB - Ultra Wideband TransmitterPhone
Equipment Class
TNB - Licensed Non-Broadcast Station TransmitterPhone
Equipment Class
6CD - 15E 6 GHz Low Power Dual ClientPhone
Equipment Class
PCE - PCS Licensed Transmitter held to earPhone
Equipment Class
UWB - Ultra Wideband Transmitter