Technical Specifications
| # | Rule Parts | Frequency Range | Power Output |
|---|
| 5 | 15E | 5.84 GHz - 5.88 GHz | 87.00 mW |
Grant NotesOutput power listed is conducted for U-NII Bands 1 - 3 and EIRP for U-NII Band 4.
This device supports 2x2 MIMO operations and bandwidths up to 80MHz for 802.11. The highest reported SAR values for head, body-worn, product specific (hotspot) and simultaneous transmission exposure conditions are 1.10 W/kg, 0.39 W/kg, 0.35 W/kg and 1.59 W/kg respectively. To satisfy FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
HAC-2019. Conversational gain values of 16.99 dB (with hearing aid) and 18.50dB (without hearing aid).