Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 24, 2003
Application Purpose
Original Equipment
Date of Application
Nov 24, 2003
Equipment Note
2.4GHz Fixed Wireless (ISM)
Frequency Range
2415.00000000 - 2457.50000000
Company
Motorola Solutions, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AP_CMM2-UM-en Issue 4 Draft November 2003 © 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A. Canopy™ Access Point Cluster and Gen II Cluster Management Module USER MANUAL AP_CMM2 User Manual Issue 4 Draft Page 2 of 48 NOTICES Important Note on Modifications Intentional or unintentional changes or modifications to the equipment must not be made unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. U.S. Federal Communication Commision (FCC) and Industry Canada (IC) Notification This device complies with part 15 of the U. S. FCC Rules and Regulations and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. In Canada, users should be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250 – 5350 MHz and 5650 – 5850 MHz and these radars could cause interference and/or damage to license-exempt local area networks (LELAN). This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the U.S. FCC Rules and with RSS-210 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures:  Increase the separation between the affected equipment and the unit;  Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to;  Consult the dealer and/or experienced radio/TV technician for help. FCC IDs and Industry Canada Certification Numbers are listed in the following table: Module Types Operating Frequency Range Maximum Transmitter Power ReflectorFCC IDIndustry Canada Cert Number SM AP BHISM 2403-2483 MHz250mWAllowed on SM and BH ABZ89FC5808109W-2400 SM AP BHU-NII 5250-5350 MHz200mWNot AllowedABZ89FC3789109W-5200 SM AP BHU-NII 5725-5825 MHz200mWAllowed on SM and BH ABZ89FC4816109W-5700 SM AP BHISM 5725-5850 MHz200mWAllowed on SM and BH ABZ89FC5804109W-5700 The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. European Community Notification Notification of Intended Purpose of Product Uses This product is a two-way radio transceiver suitable for use in Broadband RLAN systems. It uses operating frequencies which are not harmonized through the EC. All licenses must be obtained before using the product in any EC country. Declaration of conformity: Motorola declares the GHz radio types listed below comply with the essential requirements and other relevant provisions of Directive1999/5/EC. Relevant Specification EN 301 893 or similar - radio spectrum EN301489-17 - EMC EN60950 - safety Product Details for Products Tested for Compliance with Relevant EC Directives Module Type Band Frequency Range Maximum Transmitter Power Effective Isotropic Radiated Power (EIRP) Modulation Type Operating Channels Non- overlapping Channel Spacing Access Point5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module 5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Backhaul5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz AP_CMM2 User Manual Issue 4 Draft Page 3 of 48 Backhaul with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Canopy can be configured to operate at a range of frequencies, but at this time, only channels from 5745 MHz through 5805 MHz of the 5.7 GHz product have been tested for compliance with relevant EC directives. Before configuring equipment to operate outside this range, please check with your regulator. Exposure Note The Canopy Subscriber Module (SM) must be installed to provide a separation distance of at least 20 cm (7.9 in) from all persons, when adding the Canopy reflector dish (in the 2.4 or 5.7 GHz band), the reflector dish must be installed to provide a separation distance of at least 1.5m (59.1 in) from all persons and does not emit a RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb. In both configurations the maximum RMS power does not exceed 200mW. The applicable power density exposure limit is 10 Watt/m 2 , according to the FCC OET Bulletin 65, the ICNIRP guidelines, and the Health Canada Safety Code 6. The corresponding compliance distances referenced above have been determined by assuming worst-case scenarios. The peak power density (S) in the far-field of a radio-frequency source with rms transmit power P and antenna gain G at a distance d is 2 4d GP S π ⋅ = In the case of the Canopy SM without reflector, the gain is 8 dBi (a factor of 6.3), so the peak power density equals the exposure limit at a distance of 10 cm. A four-fold additional compliance margin is artificially introduced by doubling the distance to 20 cm. In the case of the Canopy SM with reflector, the gain is 26 dBi (…

Text truncated - open the document above for the full version.

Users Manual

Canopy TM Backhaul Module USER MANUAL BH02-UM-en Issue 4 Draft November 2003 © 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Backhaul User Manual Issue 4 DraftPage 2 of 55 NOTICES Important Note on Modifications Intentional or unintentional changes or modifications to the equipment must not be made unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. U.S. Federal Communication Commision (FCC) and Industry Canada (IC) Notification This device complies with part 15 of the U. S. FCC Rules and Regulations and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. In Canada, users should be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250 – 5350 MHz and 5650 – 5850 MHz and these radars could cause interference and/or damage to license-exempt local area networks (LELAN). This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the U.S. FCC Rules and with RSS-210 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures:  Increase the separation between the affected equipment and the unit;  Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to;  Consult the dealer and/or experienced radio/TV technician for help. FCC IDs and Industry Canada Certification Numbers are listed in the following table: Module Types Operating Frequency Range Maximum Transmitter Power ReflectorFCC IDIndustry Canada Cert Number SM AP BHISM 2403-2483 MHz250mWAllowed on SM and BHABZ89FC5808109W-2400 SM AP BHU-NII 5250-5350 MHz 200mWNot AllowedABZ89FC3789109W-5200 SM AP BHU-NII 5725-5825 MHz 200mWAllowed on SM and BHABZ89FC4816109W-5700 SM AP BHISM 5725-5850 MHz200mWAllowed on SM and BHABZ89FC5804109W-5700 The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. European Community Notification Notification of Intended Purpose of Product Uses This product is a two-way radio transceiver suitable for use in Broadband RLAN systems. It uses operating frequencies which are not harmonized through the EC. All licenses must be obtained before using the product in any EC country. Declaration of conformity: Motorola declares the GHz radio types listed below comply with the essential requirements and other relevant provisions of Directive1999/5/EC. Relevant Specification EN 301 893 or similar - radio spectrum EN301489-17 - EMC EN60950 – safety Product Details for Products Tested for Compliance with Relevant EC Directives Module TypeBand Frequency Range Maximum Transmitter Power Effective Isotropic Radiated Power (EIRP) Modulation Type Operating Channels Non- overlapping Channel Spacing Access Point5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module 5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Backhaul5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Backhaul User Manual Issue 4 DraftPage 3 of 55 Backhaul with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Canopy can be configured to operate at a range of frequencies, but at this time, only channels from 5745 MHz through 5805 MHz of the 5.7 GHz product have been tested for compliance with relevant EC directives. Before configuring equipment to operate outside this range, please check with your regulator. Exposure Note The Canopy Subscriber Module (SM) must be installed to provide a separation distance of at least 20 cm (7.9 in) from all persons, when adding the Canopy reflector dish (in the 5.7 GHz band), the reflector dish must be installed to provide a separation distance of at least 1.5m (59.1 in) from all persons and does not emit a RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb. In both configurations the maximum RMS power does not exceed 200mW. The applicable power density exposure limit is 10 Watt/m 2 , according to the FCC OET Bulletin 65, the ICNIRP guidelines, and the Health Canada Safety Code 6. The corresponding compliance distances referenced above have been determined by assuming worst-case scenarios. The peak power density (S) in the far-field of a radio-frequency source with rms transmit power P and antenna gain G at a distance d is 2 4d GP S π ⋅ = In the case of the Canopy SM without reflector, the gain is 8 dBi (a factor of 6.3), so the peak power density equals the exposure limit at a distance of 10 cm. A four-fold additional compliance margin is artificially introduced by doubling the distance to 20 cm. In the case of the Canopy SM with reflector, the gain is 26 dBi (a factor of 400), so the peak power density equals th…

Text truncated - open the document above for the full version.

Users Manual

Canopy TM Subscriber Module USER MANUAL SM02-UM-en Issue 4 Draft November 2003 © 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A SM User Manual Issue 4 DraftPage 2 of 33 NOTICES Important Note on Modifications Intentional or unintentional changes or modifications to the equipment must not be made unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. U.S. Federal Communication Commision (FCC) and Industry Canada (IC) Notification This device complies with part 15 of the U. S. FCC Rules and Regulations and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. In Canada, users should be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250 – 5350 MHz and 5650 – 5850 MHz and these radars could cause interference and/or damage to license-exempt local area networks (LELAN). This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the U.S. FCC Rules and with RSS-210 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures:  Increase the separation between the affected equipment and the unit;  Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to;  Consult the dealer and/or experienced radio/TV technician for help. FCC IDs and Industry Canada Certification Numbers are listed in the following table: Module Types Operating Frequency Range Maximum Transmitter Power ReflectorFCC IDIndustry Canada Cert Number SM AP BHISM 2403-2483 MHz250mWAllowed on SM and BH ABZ89FC5808109W-2400 SM AP BHU-NII 5250-5350 MHz200mWNot AllowedABZ89FC3789109W-5200 SM AP BHU-NII 5725-5825 MHz200mWAllowed on SM and BH ABZ89FC4816109W-5700 SM AP BHISM 5725-5850 MHz200mWAllowed on SM and BH ABZ89FC5804109W-5700 The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. European Community Notification Notification of Intended Purpose of Product Uses This product is a two-way radio transceiver suitable for use in Broadband RLAN systems. It uses operating frequencies which are not harmonized through the EC. All licenses must be obtained before using the product in any EC country. Declaration of conformity: Motorola declares the GHz radio types listed below comply with the essential requirements and other relevant provisions of Directive1999/5/EC. Relevant Specification EN 301 893 or similar - radio spectrum EN301489-17 - EMC EN60950 - safety Product Details for Products Tested for Compliance with Relevant EC Directives Module TypeBand Frequency Range Maximum Transmitter Power Effective Isotropic Radiated Power (EIRP) Modulation Type Operating Channels Non- overlapping Channel Spacing Access Point5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module 5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Subscriber Module with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Backhaul5.725 to 5.825 GHz 200mW RMS 1 Watt EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Backhaul with Reflector 5.725 to 5.825 GHz 200mW RMS 63 Watts EIRPHigh Index 2-level or 4-level FSK 5745 to 5805 MHz in 5 MHz increments 20 MHz Canopy can be configured to operate at a range of frequencies, but at this time, only channels from 5745 MHz through 5805 MHz of the SM User Manual Issue 4 DraftPage 3 of 33 5.7 GHz product have been tested for compliance with relevant EC directives. Before configuring equipment to operate outside this range, please check with your regulator. Exposure Note The Canopy Subscriber Module (SM) must be installed to provide a separation distance of at least 20 cm (7.9 in) from all persons, when adding the Canopy reflector dish (in the 2.4 or 5.7 GHz band), the reflector dish must be installed to provide a separation distance of at least 1.5m (59.1 in) from all persons and does not emit a RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb. In both configurations the maximum RMS power does not exceed 200mW. The applicable power density exposure limit is 10 Watt/m 2 , according to the FCC OET Bulletin 65, the ICNIRP guidelines, and the Health Canada Safety Code 6. The corresponding compliance distances referenced above have been determined by assuming worst-case scenarios. The peak power density (S) in the far-field of a radio-frequency source with rms transmit power P and antenna gain G at a distance d is 2 4d GP S π ⋅ = In the case of the Canopy SM without reflector, the gain is 8 dBi (a factor of 6.3), so the peak power density equals the exposure limit at a distance of 10 cm. A four-fold additional compliance margin is artificially introduced by doubling the distance to 20 cm. In the case of the Canopy SM with reflector, the gain is 26 dBi (a factor of 400), so the peak power density equals the …

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC ID: ABZ89FC5808 Request for Confidentiality In accordance with 47 C.F.R. Section 0.459, we, Motorola Inc., hereby request confidentiality for the block diagram, schematic and product description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. Motorola Inc.

External Photos

Canopy unit #0A003E200015 in housing

Internal Photos

CANOPY unit #0A003E200015, Radio Printed Wiring Board (Component Side): CANOPY Unit #0A003E200015, Radio Printed Wiring Board (Solder Side):

Test Report

Note: The layout and components in the logic circuitry of the 2.4GHz Radio is identical to that of the 5GHz Radio. Changes in the RF section were the removal of the frequency doubler which allows the use of the 5GHz VCO in the 2.4GHz band. No other changes to the synthesizer were required. The ceramic 5GHz band pass filters were replaced with 2.4GHz band pass filters.

Test Report

CANOPY 2400ISM Radiated Test Testing for Compliance with FCC Part 15.247 when Operated in the ISM Band 17 November 2003 Compliance testing with FCC rules part 15.247 was performed in radiated fashion since production CANOPY units have no RF connector. A test fixture was used to make power spectral density, maximum output power, and occupied bandwidth measurements. A reference antenna replacing the UUT calibrated the coupling factor for the test fixture. Measurements were made on CANOPY unit serial #0A003E200015 and #0A003E200016. The test setup diagram is as follows: MEASURING RECEIVER LO RF BB CANOPY TEST FIXTURE COMPUTER UUT POWER METER SPECTRUM ANALYZER GPIB INTERFACE SIGNAL GENERATOR SIGNAL GENERATOR COUPLER SCOPE 1234 DET SIGNAL GENERATOR POWER DIV POWER DIV POWER COMB LOAD PAD PAD PAD PAD Spectrum Analyzer Reference Level Calibration The silent carrier power at all test frequencies was normalized (via the RF attenuator pads in the test station) to 0dBm in the analyzer plots. The dBm units in the plots can be translated to dBc. TX bit error test pattern was initiated at maximum transmit duty cycle and data throughput for the radio under test. This will result in 97.7% duty cycle or an average power versus maximum power ratio of -0.10dB. Cal Plot #0A003E200015 carrier power=25.2dBm 5.247c. Band Edge Requirements The following plot shows that the CANOPY radio produces an acceptable out-of-band spectral output when operated at the channel limits of 2415MHz at the lowest frequency, and 2457.5MHz at the highest frequency. The display line indicated the –20dB specification limit for non-restricted out-of-band spectral emissions. 2-Level FSK – 20Mb Signaling 4-Level FSK – 20Mb Signaling The test results indicated that the band-edge spectral emissions were more than 20dB below the in-band power for both 2-level FSK and 4-level FSK modulation modes. The carrier frequencies tested were 2415MHz, 2435MHz and 2457.5MHz. 15.247d. Conducted Peak Power Spectral Density The plots showed below display the peak power spectral density results for the radio operation in the frequency band 2415-2457.5MHz. The carrier power (translated to a conducted measurement) at the antenna port was 25.2dBm maximum at 2435MHz. At 2415MHz the carrier power was 24.7dBm. At 2457.5MHz the carrier power was 24.5dBm. The specification limit for this measurement was –17.2dBc (8dBm) in this unit under test. 2-Level FSK – 10Mb Signaling 2-level FSK Modulation Results: The maximum peak power spectral density when measured in a 3 kHz resolution bandwidth was –20.17dBc (4.33dBm) at the uppermost operating frequency of 2457.5MHz. At 2435MHz the maximum peak power spectral density was measured to be -20.17dBc (5.03dBm). At the lowest operating frequency, 2415MHz the maximum peak power spectral density was measured to be –21.0dBc (3.7dBm). 15.247d. Conducted Peak Power Spectral Density The plots showed below display the peak power spectral density results for the radio operation in the frequency band 2415-2457.5MHz. The carrier power (translated to a conducted measurement) at the antenna port was 25.2dBm maximum at 2435MHz. At 2415MHz the carrier power was 24.7dBm. At 2457.5MHz the carrier power was 24.5dBm. The specification limit for this measurement was –17.2dBc (8dBm) in this unit under test. 4Level FSK 20MbSignaling 4FSK Modulation Results: The maximum peak power spectral density when measured in a 3 kHz resolution bandwidth was -20.33dBc (4.17dBm) at the uppermost operating frequency of 2457.5MHz. At 2435MHz the maximum peak power spectral density was measured to be -20.5dBc (4.7dBm). At the lowest operating frequency, 2415MHz the maximum peak power spectral density was measured to be –21.0dBc (3.7dBm). CANOPY 2400ISM Radiated Test Testing for Compliance with FCC Part 15.209 when Operated in the ISM Band 17 November 2003 A CANOPY 2400 ISM unit, serial#0A003E200016, was tested outdoors to check compliance with FCC requirement 15.209, restricted band emissions for ISM data-modulated radios. The testing was done using a model 3115 and a model 3116 calibrated dual-ridged waveguide-horn antennas manufactured by EMCO, Inc., an Agilent 8563E 26.5GHz spectrum analyzer, and a laptop to control the DUT and take data from the spectrum analyzer. The two antennas combined allowed a frequency measurement range of 1GHz to 26.5GHz. The spatial separation between the EMCO horn antennas and the DUT was maintained at 3 meters during the test. The FCC requirement for restricted band emissions is stated in terms of field strength at 500uV/m at a distance of 3 meters. Using the free space impedance of 377 ohms, the equivalent power density is –61.78dBm/m 2 which is equal to 663 picoWatts/m 2 . Multiplying this value by 4 pr 2 , where r is the distance in meters, equates to 75nWatts at the radio independent of frequency. Since path loss and cable loss both vary with frequency, an adjusted specification was calculated for each measurement frequency to determine if the power level in dBm measured at the spectrum analyzer was passing. It was determined that the peak power out of the radio in a 100kHz band was 18.3dBm at 2415MHz and a limit of - 1.7dBm was used as pass fail criteria for non restricted band measurements in section 15.249(c). The operating frequency of the radio presented a challenge to measuring the harmonics radiated by the radio. Since the highest harmonic to be measured is 24.575GHz, finding test equipment that possesses reasonable noise figures and obtaining coax cables with mode-free moderate loss is difficult. The resolution bandwidth of 1MHz also adds to the problem of making an effective radiated power measurement. As an aid in performing these measurements, the radio was designed with the ability to operate in continuous-wave mode, permitting the use of narrow bandwidths on the analyzer. The test antennas and test radio were mounted on adjustable tripods and placed 3 meters apart. The test setup diagram is as follows: Two differ…

Text truncated - open the document above for the full version.

Test Setup Photos

Outdoor testing site

Test Setup Photos

The test antennas and test radio were mounted on adjustable tripods and placed 3 meters apart.

Contact Information

Applicant

Matthew Nawrocki
[email protected]847-812-5841Fax: 847-576-0903

Non-Technical Contact

MotorolaPatricia Martello
[email protected]847-538-5252

Test Firm

Motorola Inc.Albert Patapack
[email protected]847-523-3670Fax: 847-523-4538

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.42 GHz - 2.46 GHz330.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The installation and operating configurations of this transmitter, including any antenna gain and cable loss, must satisfy MPE Categorical Exclusion Requirements of Sec. 2.1091. The antenna used for this transmitter must be installed to provide a seperation distance of at least 1.5 meters from all persons during normal operation. Users and installers must be provided with antenna installation instructions and transmitter operating conditions including antenna co-location requirements of 1.1307(b)(3), for satisfying RF exposure compliance.

Other Applications from Motorola Solutions, Inc.

Non Broadcast Transmitter - FCC ID ABZ89FT4940 - Motorola Solutions, Inc.
ABZ89FT4940

Non Broadcast Transmitter

Aug 06, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ABZ89FT4950

Non-Broadcast Transmitter

Jun 25, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ABZ89FT5901

Non Broadcast Transmitter

Jun 20, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Non Broadcast Transmitter - FCC ID ABZ99FT5101B - Motorola Solutions, Inc.
ABZ99FT5101B

Non Broadcast Transmitter

May 02, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Non Broadcast Transmitter - FCC ID ABZ99FT3095B - Motorola Solutions, Inc.
ABZ99FT3095B

Non Broadcast Transmitter

Mar 26, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter