Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 1 | 22,74,80,90,90.210(e) | 136 MHz - 174 MHz | 5 W | NOTE1 | 0.5000000000
ppm |
Grant NotesPower listed is conducted. Maximum conducted output power is 6.0W according to 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance.
The highest reported SAR for head and body-worn accessory use conditions are 0.90 W/kg and 3.39 W/kg respectively.
NOTE1: 11K0F3E, 7K60FXE, 7K60FXD, 7K60F1D, 7K60F1E, 7K60F1W