Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 2 | 22,74,80,90,90.21 | 406.1 MHz - 512 MHz | 4 W | NOTE 1 | 1.5
ppm |
Grant NotesPower listed is conducted. Maximum conducted output power is 4.8 W according to 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head and body-worn accessory conditions are 4.43 W/kg and 4.72 W/kg, respectively accounting for a 50% duty-cycle.
Note 1: 11K0F3E, 7K60F1E, 7K60F1D, 7K60F1W, 7K60FXE, 7K60FXD