Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 6 | 24D | 940 MHz - 941 MHz | 2.62 W | NOTE 2 | 0.5
ppm |
Grant NotesPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied or similar accessory for use with this product that provides at least 2.5 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
The highest reported SAR for head and body-worn accessory conditions are 1.02 W/kg and 1.38 W/kg respectively
Note 1: 11K0F3E, 11K0F1D, 7K60FXD, 7K60F1D, 7K60F1W, 7K60FXW, 7K60FXE, 7K60F1E, 8K10F1E
Note 2: 11K0F3E, 11K0F1D, 7K60FXD, 7K60F1D, 7K60F1W, 7K60FXW, 7K60FXE, 7K60F1E, 8K10F1D, 8K10F1E