
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AL11 USER GUIDE – Draft Rev2 1 | Page USER GUIDE AlertMaster AL11 Home Alert System Clarity, a Division of Plantronics, Inc. 4289 Bonny Oaks Drive, Chattanooga, TN 37406 Tel: 800‐426‐3738 Fax: 800‐325‐8871 E‐mail: [email protected] Website: www.clarityproducts.com ©2010 Clarity, a Division of Plantronics, Inc. All rights reserved. AlertMaster, Clarity and AL11 are trademarks or registered trademarks of Plantronics, Inc. Rev. A (04 ‐10) AL11 USER GUIDE – Draft Rev2 2 | Page CONTENTS (TO BE LEFT EMPTY UNTIL FINAL VERSION IS CREATED; THIS PAGE SHOWS THE TABLE OF CONTENTS) AL11 USER GUIDE – Draft Rev2 3 | Page IMPORTANT SAFETY INSTRUCTIONS When using your Clarity AL11, basic safety precautions should always be followed to reduce the risk of fire, electric shock and persons including the following: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. Do not use this product near a bathtub, wash basin, kitchen sink or laundry tub, in a wet basement, near a swimming pool or anywhere else there is water. 4. Avoid using a telephone (other than a cordless type) during a storm. There may be a remote risk of electrical shock from lightning. 5. Do not use a telephone to report a gas leak in the vicinity of the leak. 6. Unplug this product from the wall outlets before cleaning. Do not use liquid cleaners or aerosol cleaners on the product. Use a damp cloth for cleaning. 7. Place this product on a stable surface. Serious damage and/or injury may result if the product falls. 8. Do not cover the slots and openings on this product. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built‐in installation unless proper ventilation is provided. 9. Operate this product using the electrical voltage as stated on the base unit or the owner’s manual. If you are not sure of the voltage in your home, consult your dealer or local power company. 10. Do not place anything on the power cord. Install the product where no one will step or trip on the cord. 11. Do not overload wall outlets or extension cords as this can increase the risk of fire or electrical shock. 12. Never push any objects through the slots in the product. They can touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock. Never spill liquid of any kind on the product. 13. To reduce the risk of electrical shock, do not take this product apart. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used. 14. Unplug this product from the wall outlets and refer servicing to the manufacturer under the following conditions: A. When the power supply cord or plug is frayed or damaged. B. If liquid has been spilled into the product. C. If the product has been exposed to rain or water. D. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions. Improper adjustment may require extensive work by a qualified technician to restore the telephone to normal operation. E. If the product has been dropped or the case has been damaged. F. If the product exhibits a distinct change in performance. 15. Never install telephone wiring during a lightning storm. 16. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. 17. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. 18. Use caution when installing or modifying telephone lines. 19. Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions AL11 USER GUIDE – Draft Rev2 4 | Page ADDITIONAL SAFETY NOTES FOR CANADIAN USERS The following items are included as part of the CS‐03 Requirements. The standard connecting arrangement for the equipment is CA11A. This product meets the applicable Industry Canada technical specifications. NOTE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective operational and safety requirements. The Department does not guarantee that the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Warning: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Ringer Equivalent Number is an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to t…
Text truncated - open the document above for the full version.
[company header optional] FCC Confidentiality Request Number: CF303 Version: V01 Date: 01-02-2010 To the FCC and FCC TCB handling this application for certification Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company name Clarity’a Division of Plantronics.Inc Addresss 4289 Bonny Oaks Drive106,Chattanooga,Tennessee 37406,USA City Chattanooga Country USA request non-disclosure and confidential treatment for our certification under: Grantee Code Product Number FCC ID: ACE AL11RTXS of the following materials submitted within this certification application: (please cross what is applicable, or add other documents) x Operational Description x Block Diagrams x Schematics Diagrams Bill of Materials Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) Chattanooga 2010.06.21 Lisa.clardy Manager
[company header optional] FCC Authorization Letter Number: CF304 Version: V01 Date: 01-02-2010 We, (the approval holder) Company name Clarity’a Division of Plantronics.Inc. Addresss 4289 Bonny Oaks Drive106,Chattanooga,Tennessee 37406,USA City Chattanooga Province. Country USA declare that the following representative (agent): Name (person) Company name Asia Institute Technology (Dongguan) Limited Addresss No.6 Binhe Road, Tianxin Village, Huangjiang, City Dongguan, Guangdong Country China is hereby authorized to apply the following equipment for certification on our behalf: Product Description AlertMaster Home Alert System Type or Model(s) AL11,AL12 Tradename or Brand(s) We also authorize Teleconformity, Mr. M. Koop, (address: Rietven 31, 7534NH Enschede, Netherlands) to process this application. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) Chattanooga 2010.06.21 Lisa Clardy Manager
Report No.: F-R1006006 Page 20 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. 7 APPENDIX-Photographs of EUT Constructional Details Photo 1 Photo 2
Report No.: F-R1006006 Page 21 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Report No.: F-R1006006 Page 22 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Report No.: F-R1006006 Page 23 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 Report No.: F-R1006006 Page 24 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Photo 9
Report No.: F-R1006006 Page 1 of 27 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Test Report Client Information: Applicant: Clarity’s Division of Plantronics.Inc. Applicant add.: 4289 Bonny Oaks Drive106, Chattanooga,Tennessee 37406,USA EUT Information: EUT Name: Alert Master Home Alert System Model No.: AL11, AL12 Brand Name: N/A FCC ID ACEAL11RTXS IC ID 1186C-AL11RTXS Prepared By: Asia Institute Technology (Dongguan) Limited Add. : No.6 Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. Date of Receipt: May 30, 2010 Date of Test: May 31. ~ Jun.16, 2010 Date of Issue: Jun.28, 2010 Test Result: Pass Test procedure used: ANSI C63.4-2003, RSS-Gen Issue 2 This device described above has been tested by Asia Institute Technology (Dongguan) Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. *This test report must not be used by the client to claim product endorsement by any agency of the U.S. government. Reviewed by: Approved by: Test director Technical director Report No.: F-R1006006 Page 2 of 27 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. 1 Contents Page COVER PAGE 1 CONTENTS ...........................................................................................................................................................2 2 TEST SUMMARY ..................................................................................................................................................3 2.1 COMPLIANCE WITH FCC PART 15 SUBPART C/RSS-GEN/RSS-210.....................................................................3 2.2 MEASUREMENT UNCERTAINTY............................................................................................................................3 3 TEST FACILITY.....................................................................................................................................................4 3.1 DEVIATION FROM STANDARD...............................................................................................................................4 3.2 ABNORMALITIES FROM STANDARD CONDITIONS....................................................................................................4 4 GENERAL INFORMATION ...................................................................................................................................5 4.1 GENERAL DESCRIPTION OF EUT ........................................................................................................................5 4.2 DESCRIPTION OF TEST CONDITIONS....................................................................................................................6 4.3 PERIPHERAL LIST...............................................................................................................................................7 5 EQUIPMENTS LIST FOR ALL TEST ITEMS .......................................................................................................7 6 TEST RESULT.......................................................................................................................................................8 6.1 ANTENNA REQUIREMENT....................................................................................................................................8 6.1.1 Standard requirement ..............................................................................................................................8 6.1.2 EUT Antenna ...........................................................................................................................................8 6.2 CONDUCTION EMISSIONS MEASUREMENT...........................................................................................................9 6.2.1 limit...........................................................................................................................................................9 6.2.2 Test procedure.........................................................................................................................................9 6.2.3 Test result ..............................................................................................................................................10 6.3 RADIATED EMISSIONS MEASUREMENT..............................................................................................................12 6.3.1 Limit........................................................................................................................................................12 6.3.2 Test procedure.......................................................................................................................................12 6.3.3 Test Result .............................................................................................................................................15 6.4 OCCUPIED BANDWIDTH....................................................................................................................................18 6.4.1 Limit........................................................................................................................................................18 6.4.2 Test procedure:......................................................................................................................................18 6.4.3 Test Result .............................................................................................................................................19 6.5 TEST SETUP PHOTOGRAPH...............................................................................................................................22 7 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS .…
Text truncated - open the document above for the full version.
Report No.: F-R1006006 Page 19 of 24 Rev:None Asia Institute Technology (Dongguan) Limited No,6.Binhe Road, Tianxin Village, Huangjiang, Dongguan, Guangdong, China. 6.5 Test Setup photograph
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 303.875 MHz - 303.875 MHz | - |

Mobile phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Corded Telephone with TAM and WiFi Feature
Equipment Class
DTS - Digital Transmission System
GSM Senior Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Doorbell
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
AlertMaster Home Alert System
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver