Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PANASONIC APPLIANCESCOMPANY of AMERICA, MICROWAVE TECHNICAL LABORATORY 5201 Tollview Drive, E-Zip E2J-16 Rolling Meadows, IL. 60008 Direct Dial Line: (847)637-4673 Fax: (847)637-4677 PAPA May29, 2012 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT:Confidentiality Request regarding application for certification of FCC ID:ACLAQ3F01 Pursuant to section 0.457 and 0.459 of the commission’s rules, the applicant hereby requests confidential treatment of information accompanying this application as outlined below. Exhibit DescriptionExhibit Name SchematicsSchematics.pdf The above materials contain trade secrets and proprietary information not customarily released tothe public.Thepublic disclosure of thesematerialsmight be harmful to the applicant and provideunjustified benefits to its competitors. Pursuant to DA 04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit DescriptionExhibit Names Test Setup Photo(s)Test Setup Photos.pdf DUT ExternalPhotosExternal Photos.pdf DUT InternalPhotosInternal Photos.pdf Users ManualUser Manual.pdf Sincerely, George Vazquez Engineer, Codes & Safety Cc: S. Yamashita
PANASONIC APPLIANCESCOMPANY of AMERICA, MICROWAVE TECHNICAL LABORATORY 5201 Tollview Drive, E-Zip E2J-16 Rolling Meadows, IL 60008 Direct Dial Line: (847)637-4673 Fax: (847)637-4677 PAPA May 29, 2012 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: FILING FOR CERTIFICATION GRANTEE CODE ACL. We are sending application for modelwith FCC IdentifierACLAQ3F01. ThisMicrowave Ovenisto be approved under the regulations for part 18. In the submission you will find exhibits for measurements taken in both Radiated and Line Conducted modes. As permitted by FCC rules, these measurements were taken by a registered lab. The lab has submitted documents which are on file with the FCC.For a quick reference to all of the exhibits submitted, please reference the Application Index and Summary after this cover letter page. If there are any questions pertaining to this application, please contact me. Sincerely, George Vazquez Engineer, Codes & Safety Cc: S. Yamashita FCC ID:ACLAQ3F01 APPLICATION INDEX AND SUMMARY APPLICATION FOR CERTIFICATION Model No.Brand NameFCC ID. NE-12521 NE-12523 NE-12721 NE-12723 Panasonic ACLAQ3F01 LIST OF EXHIBITS EXHIBITA:SCHEMATIC DIAGRAM EXHIBITB~C PHOTOGRAPHS OF EQUIPTMENT EXHIBITD:TEST SETUP PHOTOS EXHIBITE:USERS MANUAL EXHIBITF:SAMPLE/LOCATION of FCC ID. LABEL EXHIBITG: TEST REPORT TECHNICAL REPORT 1. DESCRIPTION OF MEASUREMENT FACILITY: The description of the measurement facility isalreadyon file with FCC. Please refer to the commission's registrationnumber313583, 655103, 148738 and 134570. 2.USERSMANUAL Reference: EXHIBIT E 3. APPLICANT: PANASONIC APPLIANCE COMPANY of AMERICA, MICROWAVE TECHNICAL LABORATORY, E-Zip E2J-16 5201Tollview Drive Rolling Meadows, Illinois 60008 4.MANUFACTURER: PanasonicCorporation,Appliances Company, Kitchen Appliances Business Unit 1-5-1 Takatsukadai, Nishi-ku,Kobe-shi,Hyogo651-2271 Japan 5. MEASUREMENT SITE: FCC Registration Numbers 313583, 655103, 148738 and 134570. UL Japan, Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mei-ken516-0021 Japan 6. EQUIPMENT SPECIFICATIONS: Electrical Power Requirement:120Vac, 60Hz,17.3A Nominal Operating Frequency:2450 MHz Maximum RF Energy Generated:1200W (IEC 705) Magnetron Type:2M210-M1(twoprovided). Feed Type and Location:Through the wave guide on thebottom and topof the oven. Stirrer:StirrerType(two provided, bottom and top). Cabinet Dimensions:(W)422x (H)337x (D)508(mm) Oven Cavity Dimensions:(W)330x (H)175x (D)310(mm) Door Seal Type:Slit Choke seal and capacitive seal method.
EXHIBIT B–EXTERNAL PHOTOGRAPHS Front View Rear View Front Viewwith Door Open
SAMPLE AND LOCATION OF FCC ID LABEL Grantee Code: ACL Product Code: AQ3F01 MHP: Code Identifies location of manufacture MHP denotes: Panasonic Corporation, Appliances Company Kitchen Appliances Business Unit 1-5-1 Takatsukadai, Nishi-ku, Kobe-shi, Hyogo 651-2271 Japan ACLAQ3F01 EXHIBIT F Label Location 200X NE-12521 120V 17.3A SINGLE PHASE 60Hz AC PP 00001 ACLAQ3F01 APRIL 2012
EXHIBITC–INTERNALPHOTOGRAPHS Right SideViewwithout Enclosure LeftSideViewwithout Enclosure RearViewwithout Enclosure TopViewwithout Enclosure Top and BottomViewof Power Supply Board Top and BottomViewof Power Relay Board MagnetronView Door AssemblyView
Test report No. : 32HE0037-HO-A Page : 2 of 18 Issued date : May 28, 2012 FCC ID : ACLAQ3F01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Manufacturer information ............................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................ 3 SECTION 3: Test specification, procedures & results ......................................................... 4 SECTION 4: Operation of E.U.T. during testing .................................................................. 6 SECTION 5: Radiation Hazard Measurement (Safety check) ............................................ 7 SECTION 6: Radiated Emission .......................................................................................... 10 APPENDIX 1: Data of EMI test ........................................................................................... 13 Radiated Emission ....................................................................................................................... 13 APPENDIX 2: Test instruments ........................................................................................... 16 APPENDIX 3: Photographs of test setup ............................................................................. 18 Radiated Emission ....................................................................................................................... 18 Test report No. : 32HE0037-HO-A Page : 3 of 18 Issued date : May 28, 2012 FCC ID : ACLAQ3F01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Manufacturer information Company Name : Panasonic Corporation Appliances Company Kitchen Appliances Business Unit Address : 1-5-1 Takatsukadai, Nishi-ku, Kobe City 651-2271, Japan Telephone Number : +81-77-561-3199 Facsimile Number : +81-77-561-4312 Contact Person : Koji Kanzaki SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Commercial Microwave Oven Model No. : NE-12521 Serial No. : Refer to Clause 4.2 Rating : AC 120V/60Hz Output 1200W (By IEC 705) Receipt Date of Sample : March 22, 2012 Country of Mass-production : Japan Condition of EUT : Engineering prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Clock frequency in the system : 8MHz Operating frequency : 2450MHz Feature of EUT : The commercial microwave oven using magnetron. Type of Magnetron : 2M210 Door Seal Type : Choke Employed mode : Stirrer Test report No. : 32HE0037-HO-A Page : 4 of 18 Issued date : May 28, 2012 FCC ID : ACLAQ3F01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test specification Test Specification : FCC Part 18 2002, final revised on July 10, 2002 Title : FCC 47CFR Part18 Industrial, scientific, and medical equipment 3.2 Procedures and results Item Test Procedure & Limits Deviation Worst margin Result Radiation Hazard Measurement Section 18.305 FCC/OST MP-5 N/A - Complied Radiated emission Section 18.305 FCC/OST MP-5 *1) N/A 9.8dB 7370.920MHz, Vertical, AV Complied *Note: UL Japan, Inc.’s EMI Work Procedure 13-EM-W0420 and 13-EM-W0424. *Radiated emission test was only performed according to the customer’s request. *1) The limit is decided by the power. Refer to Appendix 4. 3.3 Addition to standard Other than above, no addition, exclusion nor deviation has been made from the standard. 3.4 Uncertainty EMI The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2. Test room (semi- anechoic chamber) Radiated emission (3m*)(+dB) (1m*)(+dB) (0.5m*)(+dB) 9kHz -30MHz 30MHz -300MHz 300MHz -1GHz 1GHz -10GHz 10GHz -18GHz 18GHz -26.5GHz 26.5GHz -40GHz No.1 4.2dB 5.0dB 5.1dB 4.7dB 5.7dB 4.4dB 4.3dB No.2 4.1dB 5.2dB 5.1dB 4.8dB 5.6dB 4.3dB 4.2dB No.3 4.5dB 5.0dB 5.2dB 4.8dB 5.6dB 4.5dB 4.2dB No.4 4.7dB 5.2dB 5.2dB 4.8dB 5.6dB 5.1dB 4.2dB *3m/1m/0.5m = Measurement distance Radiated emission test (3m) The data listed in this test report has enough margin, more than the site margin. Test report No. : 32HE0037-HO-A Page : 5 of 18 Issued date : May 28, 2012 FCC ID : ACLAQ3F01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 3.5 Test Location UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 FCC Registration Number IC Registration Number Width x Depth x Height (m) Size of reference ground plane (m) / horizontal conducting plane Other rooms No.1 semi-anechoic chamber 313583 2973C-1 19.2 x 11.2 x 7.7m 7.0 x 6.0m No.1 Power source room No.2 semi-anechoic chamber 655103 2973C-2 7.5 x 5.8 x 5.2m 4.0 x 4.0m - No.3 semi-anechoic chamber 148738 2973C-3 12.0 x 8.5 x 5.9m 6.8 x 5.75m No.3 Preparation room No.3 shielded room - - 4.0 x 6.0 x 2.7m N/A - No.4 semi-anechoic chamber 134570 2973C-4 12.0 x 8.5 x 5.9m 6.8 x 5.75m No.4 Preparation room No.4 shielded room - - 4.0 x 6.0 x 2.7m N/A - No.5 semi-anechoic chamber - - 6.0 x 6.0 x 3.9m 6.0 x 6.0m - No.6 shielded room - - 4.0 x 4.5 x 2.7m 4.75 x 5.4 m - No.6 measurement room - - 4.75 x 5.4 x 3.0m 4.75 x 4.15 m - No.7 shielded room - - 4.7 x 7.5 x 2.7m 4.7 x 7.5m - No.8 measurement room - - 3.1 x 5.0 x 2.7m N/A - No.9 measurement room - - 8.0 x 4.5 x 2.8m 2.0 x 2.0m - No.10 measurement room - - 2.6 x 2.8 x 2.5m 2.4 x 2.4m - No.11 measurement room - - 3.1 x 3.4 x 3.0m 2.4 x 3.4m - * Size of vertical conducting plane (for Conducted …
Text truncated - open the document above for the full version.
Test report No. : 32HE0037-HO-A Page : 18 of 18 Issued date : May XX, 2012 FCC ID : ACLAQ3F01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Radiated Emission Photo 1 Photo 2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 2.40 GHz - 2.50 GHz | 1200 W |

Microwave Oven with two Magnetrons Model 2M261-M32
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven with two Magnetrons Model 2M261-M32
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven with two Magnetrons Model 2M261-M32
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven with Magnetron
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven with Magnetron 2M261-M32
Equipment Class
8CC - Part 18 Consumer Device