FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sanyo Electric Co Ltd/
  3. AEZSCP-5K

AEZSCP-5KDual-Band Analog/PCS Phone (AMPS/CDMA)

Sanyo Electric Co Ltd
Dual-Band Analog/PCS Phone (AMPS/CDMA) - FCC ID AEZSCP-5K - Sanyo Electric Co Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Sep 19, 2000
Application Purpose
Original Equipment
Date of Application
Aug 21, 2000
Equipment Note
Dual-Band Analog/PCS Phone (AMPS/CDMA)
Frequency Range
1851.25000000 - 1908.75000000
Company
Sanyo Electric Co Ltd
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

SANYO Electric Co., Ltd. Multimedia Company Personal Telecommunication Division Tel: +81-720-70-6288 Fax:+81-720-70-6084 August 16, 2000 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. To whom it may concern: We, the undersigned, hereby authorize PCTEST Engineering Laboratory Inc., to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by PCTEST Engineering Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial Section 5301 of benefits, including FCC benefits, pursuant to of the Anti-Drug Abuse Act of 1988, 21 U.S. C. 862. Sincerely, Hiromu- Tokumatsu Manager Technical Engineering Department Personal Telecommunication Division Multimedia Company SANYO Electric Co., Ltd.

Cover Letter(s)

August 16, 2000 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: SANYO Electric Co., Ltd. FCC ID: AEZSCP-5K Part 24/22 Certification Gentlemen: Attached herewith, on behalf of SANYO Electric Co., Ltd., is an application for Part 24/22 Certification of the following Dual-Band Analog/PCS phone: FCC ID: AEZSCP-5K TRADE / MODEL: SANYO SCP-5000 EUT TYPE: Dual-Band Analog/PCS Phone (AMPS/CDMA) Tx Freq. Range: 1851.25 – 1908.75 MHz (CDMA) 824.04 – 848.97 MHz (AMPS) Max. RF Output Power: 0.393 Watts ERP - AMPS (25.942 dBm) 0.412 Watts EIRP - PCS CDMA (26.151 dBm) Attached is the applicant’s Letter of Authorization, Confidentiality Request, ESN Affidavit, 911 compliance statement, measurement report data and plots, RF Exposure measurement report and data, FCC ID label and location, test setup photographs, internal and external photographs, block diagram (confidential), schematic diagrams (confidential), operational description, parts list & tune-up procedure, and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. cc: Mr. Koichi Takahashi Vice President, Marketing SANYO Fisher (USA) Corp.

External Photos

© 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone

ID Label/Location Info

© 2000 PCTEST Lab FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. (SEE NEXT PAGE) L +&rht@ DUAl.4AND SPRINT PCS PHONE’” S#h’0 Model No. SCP- 5000 For information. caHl88&m4pcs FCC l D : A E Z S C P - 5 K Made in JAPAN 1 l-

Internal Photos

© 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone

Operational Description

Operational Description FCC ID:AEZSCP-5K Model:SCP-5000 SANYO SCP-5000 is a Dual-Band Mode digital CDMA/AMPS phone. It is designed to comply with Part 15, Part 22 and Part 24 of the CFR. PCS Band (CDMA): TX Frequencies: 1851.25MHz - 1908.75MHz RX Frequencies: 1931.25MHz - 1988.75MHz LO Frequencies: 1720.87MHz - 1778.37MHz TCXO Frequency: 19.68MHz Cellular Band (AMPS) TX Frequencies: 824.040MHz - 848.970MHz RX Frequencies: 869.040MHz - 893.970MHz LO Frequencies: 954.42MHz - 979.35MHz TCXO Frequency: 19.68MHz CDMA Max. Conducted Output Power : +25.2dBm (0.33W) AMPS Max. Conducted Output Power: +24.9dBm (0.31W) Battery voltage: 3.7V Nominal, 3.4 Min., V Li-ion (Supplied with phone) Frequency Stabilization A voltage controlled temperature compensated crystal oscillator (VCTCXO) is utilized as a frequency reference for all of the transceiver local oscillators. This crystal oscillator is specified to a frequency stability of +/- 2.5ppm over temperature and voltage variations. The synthesizer lock status is constantly monitored by the microprocessor and transmission is disabled whenever an out of lock condition is detected. The mobile is locked to the base station during operation. The mobile receiver constantly monitors the received signal from the base station and makes necessary frequency adjustments on the VCTCXO to correct any frequency errors between the mobile and he base station. Suppression of Spurious Radiation Spurious and harmonic suppression is achieved by proper design with various filters and sufficient use of EMI shields. Rigorous testing at the factory ensures continuous compliance. Limiting Power Each mobile is individually calibrated at the factory to ensure Max. power of no more than +25.2dBm for PCS CDMA and +24.9dBm for AMPS by employing a proper frequency and temperature compensation schemes for both the TX and RX automatic gain control (AGC) amplifiers. There are also hardware circuitries to monitor TX power and software reset limits to limit maximum TX power. Limiting Modulation The audio input is sampled, digitally limited, and then filtered to amplitude and frequency limit the signal applied to the modulator. The device supports AMPS standards and ANSI J-STD-008 for CDMA operation. The device has an operating temperature range of –30 to +60C. The functions include Compandor, PLL lock detector for received SAT, filtering of received data, and audio signal filtering for signals.

Parts List/Tune Up Info

SCP-5000 Parts List Ref NO.DescriptionRef NO.DescriptionRef NO.DescriptionRef NO.Description L10016.8nH L10038.2nH L10055.6nH L11014.7nH L11036.8nH L1104150nH L110627nH L110710nH L11088.2nH L110947nH L111047nH L1111120nH L1112120nH L111539nH L111647nH L11185.6nH L11196.8nH L11202.2nH L1121220nH L1122220nH L11233.3nH L11302.2nH L120112nH L120212nH L120356nH L120456nH L130127nH L130227nH L13034.7nH L13044.7nH L130510nH L130822nH L14013.9nH L14021.5nH L140312nH L140415nH L140510nH L14061.2nH L14205.6nH L14226.8nH L14302.7nH L14312.7nH L14324.7nH L14334.7nH SCP-5000 Parts List Ref NO.DescriptionRef NO.DescriptionRef NO.DescriptionRef NO.Description C10011.5pFC1313100pFC152110uF C10028pFC13140.01uFC15220.01uF C1005100pFC131547pFC15231000pF C11000.01uFC131647pFC1524100pF C11011pFC131747pFC1525100pF C11020.1uFC1318100pFC15261000pF C11081000pFC13198pFC15271000pF C11091000pFC13203300pFC15281000pF C11102pFC13213300pFC15290.01uF C1111100pFC1322100pFC15304700pF C11121000pFC13231000pFC15310.47uF C1113100pFC13240.01uFC15320.022uF C111410pFC13250.01uFC15400.1uF C1115100pFC13261000pFC16031000pF C11170.1uFC13270.022uFC1801100pF C111856pFC13280.47uFC1802100pF C1119100pFC1329560pFC18031uF C11201000pFC13301000pFC18042.2uF C112118pFC1331100pFC18052.2uF C11221.5pFC1332100pFC1807100pF C11230.01uFC133312pFC18081uF C112412pFC13340.1uFC18092.2uF C1127100pFC13354pFC18102.2uF C1128100pFC13364pFC18111uF C11301pFC1403100pFC181310uF C113539pFC1404100pF C113639pFC14051000pF C1139100pFC14061000pF C11401000pFC14071000pF C114133pFC141010pF C11421000pFC141110pF C1143100pFC141210pF C11441000pFC14130.01uF C114533pFC14149pF C11461000pFC141515pF C11473pFC141615pF C11480.01uFC14174.7uF C11532pFC141815pF C115410pFC141915pF C1155100pFC14206pF C11601000pFC14213pF C11650.5pFC142215pF C11681.5pFC142310pF C12010.01uFC1425100pF C12024700pFC14261uF C12031000pFC1427100pF C12060.01uFC14281uF C12080.01uFC1429100pF C12090.01uFC1430100pF C12100.22uFC14310.01uF C12111000pFC14341000pF C12121000pFC14351000pF C12130.01uFC14381.5pF C1214100pFC14451000pF C12150.01uFC14504pF C12161000pFC15010.01uF C121722pFC1503100pF C121922pFC15041uF C130522pFC15050.1uF C13081000pFC15061000pF C13090.1uFC150710uF C13104700pFC15080.022uF C13110.1uFC15090.22uF C13120.01uFC15200.01uF SCP-5000 Parts List Ref NO.DescriptionRef NO.DescriptionRef NO.DescriptionRef NO.Description R10010R14191.2k R10020R14200 R10050R14260 R11010R14280 R11050R15000 R11066.8kR1501680 R110810R150215k R11093.3kR150347k R11101kR15044.7k R11128.2kR1505120k R111468R1506100k R111510R15074.7k R111610R150810k R11204.7kR150927 R112110kR15101k R12011kR15113.9k R120210R1512220 R120310R15130 R12041kR15141k R120510kR15151k R120610kR1516 R12074.7kR151751 R12088.2kR15181k R1209100R15191k R12100R15201k R12110R18011 R12120R18021 R122010kR18051 R12811kR18061 R12821kR18100 R12831k R12841k R12851k R12861k R12871k R12881k R13011k R13021k R13040 R13050 R130610k R13070 R130812k R13091k R13106.2k R131110k R131210k R13200 R132247 R13310 R140010k R14010 R1406150 R14080 R14091k R14100 R141156 R141256 R141356k R14141k R14153.9k R141610k R14171.8k R141822k SCP-5000 Parts List Reference No.FunctionPart No. PLL Synthesizer IC 151PLL ICMB15F73SP X1502 PCS/AMPS VCOYK509MDB097M1750B Q1502TransisterHN7G03FU Transmitter IC143PCS Power AmplifierRF2153 X144 AMPS Power AmplifierPA3100 2 IC141SwitchuPG158TB IC142Invert ICTC7SU04FU IC162Temp Sens.LM20M7X Q1401,1402TransisterHN7G03FU D1401,1402DiodeHSC88 X101DiplexerLFDP15N0039A XF102PCS DuplexerDFYK1R88C1R96HHJ XF103AMPS DuplexerEFSD836MB1Z1 XF143PCS IsolatorCE0421R88DCB XF146AMPS IsolatorCE053R836DCA XF141PCS SAW FilterSAFC1867.5T1897.5ML1DOT XF144AMPS SAW FilterSRF836NJC31 XF142PCS CouplerLDC10B190J1880 XF145AMPS CouplerLDC10B150J0836 Regulator IC181, 182Regulator(3.0V/3.0V)R5321D003A IC183Regulator(2.9V)R1121N291B Receiver IC113LNA/MixerRFR3100 IC112PCS LNANE34018 IC111AMPS LNAGN01096B IC114TC7SU04FU Q1101,1102TransisterHN7G03FU XF112PCS RF SAW FilterM196NW2BP_KF00541 XF111AMPS RF SAW FilterSAFC881.5MF1A0T X114PCS IF SAW FilterB4910 XF113AMPS IF SAW FilterSAFC85.380MA15X IF AGC Circuit IC131TX AGC+Mixer ICRFT3100 IC121RX AGC ICIFR3000 Q1201,1301TransistorDTC144EE D1202,1203,1301,1302DiodeHVC202A Q1202,1302DiodeDAN235E TCXO Circuit X1501TCXOKT18-ECV30A-19.680M Q1501Transistor2SC4649 Tentative Specification of ISOLATORWritten by M. Kawashima Tentative SPEC No. : NCE64-P0822A Checked by Y. Ohtani Part Number : CE0401G88DCB000TT1 Date 19/ Apr./ ’00 Old Part Number : CE0401R88DCB A>: Revised by MK on May/19/’00 1. Electrical Frequency Range1850∼1910 MHz Operating Temp.-35∼+85°C+20∼+30°C Insertion Loss0.6 dB max.A> 0.5 dB max. Isolation14 dB min.A> 15 dB min. VSWR Forward Reverse 1.6 max. 1.6 max. --- max. --- max. Rating Power2.5 W max. Reflection Power0.6 W max. Impedance50 Ω Attenuation Absolute value A> (*) 3700∼3820MHz 10 dB min. (*) 5550∼5730MHz 15dB min. Note1: Case surface temperature should be less than 100°C under the operation. 2: The specifications and dimensions in this spec. may be subject to change without notice. 3: (*) will not be measured in regular production. This value always meets the specification. 2: Mechanical (Figure, Circuit, Port) OTHERWISE SPECIFIED : +/-0.2 TOLERANCES UNLESS DIMENSIONS : mm M 1 : OUT 6 : IN 2,3,4,5 : GROUND I/O,GND Terminal Solder resist 0.4+/-0.1 0.2+/-0.1 1.4 0.05+/-0.1 0.4+/-0.1 2.1 0.02 1.9+/-0.1 4 5 6 3 2 1 4.0 1.4 4.0 0.4+/-0.1 0.4+/-0.1 Standard Preliminary Specification of ISOLATORWritten byY.Nakamura Preliminary SPEC No. :NCE64-P0637G Checked byK.Matsunaga Part Number :CE0521R88DCB Date25/ Feb/ ’97 1. Electrical Frequency Range1850∼1910 MHz Operating Temp.-35∼+85°C+20∼+30°C Insertion Loss 0.6 dB max. --- dB max. IsolationB> 14 dB min.B> 15 dB min. VSWR Forward Reverse 1.6 max. 1.6 max. --- max. --- max. Rating Power2.5 W max. Reflection Power0.6 W max. Impedance50 Ω Attenuation Absolute value F>C>(*) 3700∼3820MHz 3 dB min.(-35∼+85°C) C> (*) 5550∼5730MHz 10 dB min.(-35∼+85°C) Note1: Case surface temperature should be less than 100…

Text truncated - open the document above for the full version.

RF Exposure Info

ering Lab., Inc. PCTEST Engineering Laboratory, Inc. 66606660--B Dobbin Road B Dobbin Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290TEL (410) 290--6652 6652 •• FAX (410) 290 FAX (410) 290--66546654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) SANYO ELECTRIC CO., LTD. Dates of Tests: August 14-18, 2000 c/o Sanyo Sales & Supply (USA) Corp. Test Report S/N: SAR.200814408.AEZ 900 North Arlington Heights Road, Suite 300 Test Site: PCTEST Lab, Columbia, MD USA Itasca, IL 60143-2844 Attn: Mr. Koichi Takahashi, V.P. Marketing SANYO Fisher (USA) Corporation FCC ID AEZSCP-5K APPLICANT SANYO ELECTRIC CO., LTD. EUT Type: Dual-Band Analog/PCS Phone (AMPS/CDMA) Tx Frequency: 824.04 – 848.97 MHz (AMPS) / 1851.25 – 1908.75 MHz (PCS CDMA) Rx Frequency: 869.04 – 893.97 MHz (AMPS) / 1931.25 – 1988.75 MHz (PCS CDMA) Max. RF Output Power: 0.393 W ERP AMPS (25.942 dBm), 0.412 W EIRP PCS CDMA (26.151 dBm) Max. SAR Measurement: 1.400W/kg (1g) AMPS Head SAR; 0.657W/kg (1g) PCS CDMA Head SAR; 1.350W/kg (1g) AMPS Body SAR; 1.380W/kg (1g) PCS CDMA Body SAR; 1.640W/kg (10g) AMPS Hand SAR; 2.290W/kg (10g) PCS CDMA Hand SAR Trade Name/Model(s): SANYO SCP-5000 FCC Classification: Licensed Portable Transmitter Held to Ear (PCE) Application Type: Certification Serial Number: n/a (pre production) FCC Rule Part(s): 2.1093; ET Docket 96.326; 24(E); 22(H) This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1992. (See Test Report). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). 200814408.AEZ SAR Measurement Report FCC Part 24/22 Certification © 2000 PCTEST Lab i Table of Contents 1.1 SCOPE 1 2.1 INTRODUCTION / SAR DEFINITION 2 3.1 SAR MEASUREMENT SET-UP 3 4.1 E-FIELD PROBE SYSTEM 4 5.1 E-FIELD PROBE CALIBRATION PROCESS 5-6 6.1 PHANTOM, HOLDER, & EQUIVALENT TISSUE 7 7.1 SYSTEM SPECIFICATIONS 8 8.1 MEASUREMENT PROCESS 9 9.1 TEST POSITION OF THE PHONE 10 10.1 BODY SAR TEST SETUP 11 11.1 ANSI/IEEE C95.1 RF EXPOSURE LIMITS 12 12.1 MEASUREMENT UNCERTAINTIES 13 13.1 TEST DATA SUMMARY 14-19 14.1 SAR TEST EQUIPMENT LIST 20 15.1 CONCLUSION 21 16.1 REFERENCES 22 Test Report S/N: SAR.200814408.AEZ SAR Measurement Report Test Date(s): August 14-18, 2000 FCC Part 24/22 Certification SANYO FCC ID: AEZSCP-5K (Model: SCP-5000) © 2000 PCTEST Lab Dual-Band Analog/PCS Phone (AMPS/CDMA) 1 SAR MEASUREMENT REPORT 1.1 Scope Environmental evaluation measurements of specific absorption rate 1 (SAR) distributions in simulated human head and body tissues exposed to radiofrequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 2 Company Name: SANYO ELECTRIC CO., LTD. c/o Sanyo Sales & Supply (USA) Corp. Address: 900 North Arlington Heights Road, Suite 300 Itasca, IL 60143-2844 Attention: Koichi Takahashi, V.P. Marketing SANYO Fisher (USA) Corporation • EUT Type: Dual-Band Analog/PCS Phone • Trade Name: SANYO • Model(s): SCP-5000 • FCC IDENTIFIER: AEZSCP-5K • S/N: Pre-production • Tx Frequency: 824.04 – 848.97 MHz (AMPS) 1851.25 – 1908.75 MHz (PCS CDMA) • Rx Frequency: 869.04 – 893.97 MHz (AMPS) 1931.25 – 1988.75 MHz (PCS CDMA) • Application Type: Certification • FCC Classification: Licensed Portable Transmitter Held to Ear (PCE) • Modulation(s): AMPS / CDMA • FCC Rule Part(s): § 2.1093, Docket 96-326; § 24(E); § 22(H) • Max. RF Output Power: 0.393W ERP AMPS (25.942 dBm) / 0.412W EIRP PCS CDMA (26.151 dBm) • Antenna Type: Helical • Antenna Dimensions: 7.4 cm. (Length) • Dates of Tests: August 14-18, 2000 • Place of Tests: PCTEST Engineering Lab. Columbia, MD, U.S.A. • Report Serial No.: SAR.200814408.AEZ 1 Specific Absorption Rate (SAR) is a measure of the rate of energy absorption due to exposure to an RF transmitting source (wireless portable device). 2 IEEE/ANSI Std. C95.1-1992 limits are used to determine compliance with FCC ET Docket 93-62. Fig. 1 SAR Test Setup Test Report S/N: SAR.200814408.AEZ SAR Measurement Report Test Date(s): August 14-18, 2000 FCC Part 24/22 Certification SANYO FCC ID: AEZSCP-5K (Model: SCP-5000) © 2000 PCTEST Lab Dual-Band Analog/PCS Phone (AMPS/CDMA) 2 2.1 INTRODUCTION The FCC has adopted the guidelines for evaluating the environmental effects of radiofrequency radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-1992 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. (c) 1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New York 10017.[2] The measurement procedure described in IEEE/ANSI C95.3-1992 Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave[3] is used for guidance in measuring SAR due to the RF radiation exposure from the Equipment Under Test (EUT). These criteria for…

Text truncated - open the document above for the full version.

RF Exposure Info

SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.939 mW/g, SAR (10g): 0.616 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0991 [824.04MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 9.99E-2 3.00E-1 5.00E-1 6.99E-1 8.99E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.40 mW/g, SAR (10g): 0.917 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0991 [824.04MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 1.48E-1 4.45E-1 7.42E-1 1.04E+0 1.33E+0 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.745 mW/g, SAR (10g): 0.484 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0383 [836.49MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 7.92E-2 2.38E-1 3.96E-1 5.54E-1 7.13E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.14 mW/g, SAR (10g): 0.738 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0383 [836.49MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 1.22E-1 3.67E-1 6.12E-1 8.56E-1 1.10E+0 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.09 mW/g, SAR (10g): 0.711 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0799 [848.97MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 1.15E-1 3.44E-1 5.74E-1 8.04E-1 1.03E+0 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- FM Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.29 mW/g, SAR (10g): 0.837 mW/g SANYO Dual-Band Model:SCP-5000 FM Mode, Ch.0799 [848.97MHz] Conducted Power = 24.9dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 1.35E-1 4.04E-1 6.73E-1 9.43E-1 1.21E+0 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.657 mW/g, SAR (10g): 0.306 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 4.90E-2 1.47E-1 2.45E-1 3.43E-1 4.41E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.404 mW/g, SAR (10g): 0.200 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 3.57E-2 1.07E-1 1.78E-1 2.50E-1 3.21E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.362 mW/g, SAR (10g): 0.165 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 2.57E-2 7.71E-2 1.29E-1 1.80E-1 2.31E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.318 mW/g, SAR (10g): 0.157 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 2.98E-2 8.94E-2 1.49E-1 2.09E-1 2.68E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.235 mW/g, SAR (10g): 0.0994 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.1175 [1908.75MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 1.68E-2 5.04E-2 8.40E-2 1.18E-1 1.51E-1 PCTEST Engineering Laboratory, Inc. SANYO FCC ID:AEZSCP-5K -- PCS Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.241 mW/g, SAR (10g): 0.119 mW/g SANYO Dual-Band Model:SCP-5000 PCS Mode, Ch.1175 [1908.75MHz] Conducted Power = 25.2dBm; Flip = open Test Date -- 08-14-2000 SAR Tot [mW/g] 2.24E-2 6.72E-2 1.12E-1 1.57E-1 2.02E-1 PCTEST En…

Text truncated - open the document above for the full version.

RF Exposure Info

© 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone © 2000 PCTEST Lab FCC ID: AEZSCP-5K NVLAP Lab Code: 1004310 SANYO Dual-Band Analog / PCS Phone

RF Exposure Info

i Safety Information: FCC RF Exposure Information WARNING! Read this information before using your phone In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96- 326 adopted an updated safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. CAUTION Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. Do not use the phone with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Please contact your local dealer for replacement antenna. Body-worn Operation This device was tested for typical body-worn operations with the back of the phone kept 0.40 inches (1.0cm) from the body. To comply with FCC RF exposure requirements, a minimum separation distance of 0.40 inches (1.0cm) must be maintained between the user’s body and the back of the phone, including the antenna, whether extended or retracted. All belt-clips, holsters and similar accessories used by this device must not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with FCC RF exposure limits and should be avoided. Note: For more information about RF exposure, please visit the FCC website at www.fcc.gov

RF Exposure Info

Probe ET3DV5 SN:1370 Manufactured: February 1999 Calibrated: February 2000 Calibrated for System DASY3 Page 1 of 8 ET3DV5 SN:1370 Introduction The performance of all probes is measured before delivery. This includes an assessment of the characteristic parameters, receiving patterns as a function of frequency, frequency response and relative accuracy. Furthermore, each probe is tested in use according to a dosimetric assessment protocol. The sensitivity parameters (NormX, NormY, NormZ), the diode compresion parameter (DCP) and the conversion factor (ConvF) of the probe and some of the measurement diagrams are given in the following. The performance of the individual probes varies slightly due to tolerances arising from the manufacturing process. Since the lines are highly resistive (several MOhms), the offset and noise problem is greatly increased if signals in the low μ V range are measured. Accurate measurement below 10 μW/g are possible if the following precautions are taken. 1) check the current grounding with the multimeter 1 , i.e., low noise levels, 2) compensate the current offset 1 , 3) use long integration time (approx. 10 seconds), 4) calibrate 1 before each measurement, 5) persons should avoid moving around the lab while measuring. Since the field distortion caused by the supporting material and the sheath is quite high in the θ direction, the receiving pattern is poor in air. However, the distortion in tissue equivalent material is much less because of its high dielectricity. In addition, the fields induced in the phantoms by dipole structures close to the body are dominently parallel to the surface. Thus, the error due to non-isotropy is much better than 1 dB for dosimetric assessments. The probes are calibrated in the TEM cell ifi 110 although the field distribution in the cell is not very uniform and the frequency response is not very flat. To ensure consistency, a strict protocol is followed. The conversion factor (ConF) between this calibration and the measurement in the tissue simulation solution is performed by comparison with temperature measurements and computer simulations. This conversion factor is only valid for the specified tissue simulating liquids at the specified frequencies. If measurements have to be performed in solutions with other electrical properties or at other frequencies, the conversion factor has to be assessed by the same procedure. As the probes have been constructed with printed resistive lines on ceramic substrates (thick film technique), the probe is very delicate with respect to mechanical shocks. Attention: Do not drop the probe or let the probe collide with any solid object. Never let the robot move without first activating the emergency stop feature (i.e., without first turning the data acquisition electronics on). 1 Feature of the DASY Software Tool. Fig 1: Due to the field distortion caused by the supporting mat…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hideaki Mukaida
[email protected]818-998-7322Fax: 818-701-4192

Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

6660-B Dobbin Road · Columbia, Maryland · United States

Non-Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
324E1.85 GHz - 1.91 GHz412.00 mW1M25F9W2.5 ppm
Confidentiality
Long Term

Other Applications from Sanyo Electric Co Ltd

Cellular CDMA Phone with Bluetooth - FCC ID AEZW63SA - Sanyo Electric Co Ltd
AEZW63SA

Cellular CDMA Phone with Bluetooth

Mar 30, 2008

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
Cellular/ PCS CDMA Phone with Bluetooth - FCC ID AEZSCP-3800 - Sanyo Electric Co Ltd
AEZSCP-3800

Cellular/ PCS CDMA Phone with Bluetooth

Mar 09, 2008

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Cellular/ PCS CDMA Phone with Bluetooth - FCC ID AEZSCP-25H - Sanyo Electric Co Ltd
AEZSCP-25H

Cellular/ PCS CDMA Phone with Bluetooth

Sep 12, 2007

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
W-CDMA subscriber terminal - FCC ID AEZCPE-400-2C0 - Sanyo Electric Co Ltd
AEZCPE-400-2C0

W-CDMA subscriber terminal

Jun 14, 2007

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
PND (Personal Navigation Device) - FCC ID AEZNVM-4070 - Sanyo Electric Co Ltd
AEZNVM-4070

PND (Personal Navigation Device)

Jun 04, 2007

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified