Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 1 | 80 | 156 MHz - 162 MHz | 5 W | 16K0G3E | 3.2000000000
ppm |
Grant NotesOutput power listed is rated conducted. Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in push-to-talk held-near-face and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and audio accessory configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements, and users must be provided with the training information. The highest reported SAR values for FCC-authorized operations accounting for a 50% duty factor are: face: < 0.10 W/kg; body: < 0.10 W/kg; simultaneous exposure: 0.67 W/kg.