
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX J: USER’S MANUAL Please see the following Operator’s Manual. DIGITAL/ANALOG PORTABLE RADIO OPERATING MANUAL 5100 SERIES PORTABLERADIO VHF/UHF/700 and 800 MH Z PROJECT25 CONVENTIONAL SMARTNET ® /S MARTZONE ® 7.2 VDC, 1 and 5 Watts (VHF); 1 and 4 Watts (UHF); 1 and 3 Watts (700/800 MHz) Part No. 242-51xx-xxx 3 RF EXPOSURE INFORMATION RF ENERGY EXPOSURE AWARENESS AND CONTROL INFORMATION, AND OPERATIONAL INSTRUCTIONS FOR FCC OCCUPATIONAL USE REQUIREMENTS BEFORE USING YOUR PORTABLE 2-WAY RADIO, READ THIS IMPORTANT RF ENERGY AWARENESS AND CONTROL INFORMATION AND OPERATIONAL INSTRUCTIONS TO ENSURE COMPLIANCE WITH THE FCC’S RF EXPOSURE GUIDELINES. NOTICE: This radio is intended for use in occupa- tional/controlled conditions, where users have full knowledge of their exposure and can exercise control over their exposure to meet FCC limits. This radio device is NOT authorized for general population, consumer, or any other use. This 2-way radio uses electromagnetic energy in the radio frequency (RF) spectrum to provide commu- nications between two or more users over a distance. It uses radio frequency (RF) energy or radio waves to send and receive calls. RF energy is one form of elec- tromagnetic energy. Other forms include, but are not limited to, electric power, sunlight and x-rays. RF energy, however, should not be confused with these other forms of electromagnetic energy, which when used improperly can cause biological damage. Very high levels of x-rays, for example, can damage tissues and genetic material. Experts in science, engineering, medicine, health and industry work with organizations to develop stan- dards for exposure to RF energy. These standards provide recommended levels of RF exposure for both workers and the general public. These recommended RF exposure levels include substantial margins of protection. All 2-way radios marketed in North America are designed, manufactured and tested to ensure they meet government established RF expo- sure levels. In addition, manufacturers also recom- mend specific operating instructions to users of 2-way radios. These instructions are important because they inform users about RF energy exposure and provide simple procedures on how to control it. Please refer to the following websites for more information on what RF energy exposure is and how to control your expo- sure to assure compliance with established RF expo- sure limits. •http://www.fcc.gov/oet/rfsafety/rf-faqs.html •http://www.osha.gov/SLTC/ radiofrequencyradiation/index.html FEDERAL COMMUNICATIONS COMMISSION REGULATIONS The FCC rules require manufacturers to comply with the FCC RF energy exposure limits for portable 2-way radios before they can be marketed in the U.S. When 2-way radios are used as a consequence of employment, the FCC requires users to be fully aware of and able to control their exposure to meet occupa- tional requirements. Exposure awareness can be facili- tated by the use of a product label directing users to specific user awareness information. Your EFJohnson 2-way radio has a RF exposure product label. Also, your EFJohnson user manual, or product manual, or separate safety booklet includes information and oper- ating instructions required to control your RF exposure and to satisfy compliance requirements. COMPLIANCE WITH RF EXPOSURE STANDARDS Your EFJohnson 2-way radio is designed and tested to comply with a number of national and international standards and guidelines (listed below) for human exposure to radio frequency electromagnetic energy. This radio complies with the IEEE and ICNIRP expo- sure limits for occupational/controlled RF exposure environment at operating duty factors of up to 50% transmitting and is authorized by the FCC for occupa- tional use only. In terms of measuring RF energy for compliance with the FCC exposure guidelines, your radio radiates measurable RF energy only while it is transmitting (during talking), not when it is receiving (listening) or in standby mode. Note: The approved batteries supplied with this radio are rated for a 5-5-90 duty factor (5% talk-5% listen - 90% standby), even though this radio complies with the FCC occupational RF exposure limits and may operate at duty factors of up to 50% talk. 4 RF EXPOSURE INFORMATION Your EFJohnson 2-way radio complies with the following RF energy exposure standards and guide- lines: •United States Federal Communications Commis- sion, Code of Federal Regulations; 47 CFR §§ 1.1307, 1.1310, 2.1091 and 2.1093 •American National Standards Institute (ANSI) / Institute of Electrical and Electronic Engineers (IEEE) C95. 1-1992 •Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999 Edition RF EXPOSURE COMPLIANCE AND CONTROL GUIDELINES AND OPERATING INSTRUCTIONS To control your exposure and ensure compliance with the occupational/controlled environment expo- sure limits always adhere to the following procedures. Guidelines : •Do not remove the RF Exposure Label from the device. •User awareness instructions should accompany device when transferred to other users. •Do not use this device if the operational require- ments described herein are not met. Operating Instructions : •Transmit no more than the rated duty factor of 50% of the time. To transmit (talk), push the Push-To- Talk (PTT) button. To receive calls, release the PTT button. Transmitting 50% of the time, or less, is important because this radio generates measurable RF energy exposure only when transmitting (in terms of measuring for standards compliance). •Hold the radio in a vertical position in front of face with the microphone (and the other parts of the radio, including the antenna) at least one inch (2.5 am) away from the nose. Keeping the radio at the proper distance is important because RF exposures decrease…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX C: CONFIDENTIALITY REQUEST LETTER Please see the following page. Waseca Office: E.F. Johnson Company • 299 Johnson Ave., P.O. Box 1249 • Waseca, MN 56093-0514 • 800-328-3911 • 507-835-6222 • Fax 507-835-8356 www.efjohnson.com September 14, 2004 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: The following information is to be held confidential pursuant of 47 CFR Part 0 §0.457 and Section 552(b)(4) of the Freedom of Information Act, because the information provided contains trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. • Schematics • Product Description • Block Diagram • Bill of Materials (Parts List) / Alignment Sincerely, John Oblak VP New Technology E. F. Johnson Co.
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX B: AGENCY AUTHORIZATION LETTER Please see the following page. Waseca Office: E.F. Johnson Company • 299 Johnson Ave., P.O. Box 1249 • Waseca, MN 56093-0514 • 800-328-3911 • 507-835-6222 • Fax 507-835-8356 www.efjohnson.com September 14, 2004 Federal Communications Commission EQUIPMENT AUTHORIZATION BRANCH 7435 Oakland Mills Road Columbia, MD 21046 Re: Agent Authorization To Whom It May Concern: E. F. Johnson Co. hereby authorizes Rhein Tech Laboratories, Inc. (RTL), 360 Herndon Parkway, Suite 1400, Herndon, VA 20170 to act as agent. APPLICANT ANTI-DRUG ABUSE CERTIFICATION: In signing this letter, Applicant certifies that, in the case of an individual applicant, he or she is not subject to a denial of federal benefits, that includes: FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a), or, in the case of a non-individual applicant. No party to the application is subject to a denial of federal benefits, that includes FCC benefits, pursuant to that section. For the definition of a “party” for these purposes, see 47 CFR 1.2002(b). Sincerely, John Oblak VP New Technology E.F. Johnson Co.
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX D: ATTESTATION LETTER Please see the following page. Waseca Office: E.F. Johnson Company • 299 Johnson Ave., P.O. Box 1249 • Waseca, MN 56093-0514 • 800-328-3911 • 507-835-6222 • Fax 507-835-8356 www.efjohnson.com September 14, 2004 Federal Communications Commission EQUIPMENT AUTHORIZATION BRANCH 7435 Oakland Mills Road Columbia, MD 21046 Re: Programming Capability Dear FCC Representative; Reference part 90.203(e), frequency programming capability. The end user will not be able to program the channel frequencies. A service shop or authorized agent using a special programming cable and computer software can program the allowed TX/RX frequencies. The end user can only select from the preprogrammed channels using the channel select knob. The software and programming cable are not available to the end user. Sincerely, John Oblak VP New Technology E.F. Johnson Co.
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 December 22, 2004 RE: FCC ID: ATH2425141_ATCB002026 Attention: Desmond A. Fraser I have a few comments on this Application. Please note that further comments may arise in response to answers provided to the questions below. 1. Please note that the SAR report has some very large power drifts associated. While you have provided a power drift plot, it would be good if an explanation of why the power drifted so much could be provided. After all, a 70+% change is quite extreme for SAR. Was this also experienced during EMC testing? How did it affect power or spurious emissions measurements during EMC testing? Providing these answers may help to understand the device and how it operates under normal conditions and gives a better understanding of the testing overall and compliance. SAR Response : We have observed that high power PTT radios in the UHF and VHF bands typically have a more extreme drift during the SAR test than during a bench test. This is due to the fact that the antenna is coupling to the tissue simulating fluid in the phantom and that the phantom itself is insulating the radio. These effects tend to make the radio heat up a lot more than it does on a bench. This heating effect can cause very high drifts during a SAR test. During the Body-Worn SAR test, the antenna is typically at a different distance from the phantom than for the Face-Held test. Experience has shown that this can lead to not only a difference in SAR level but also a difference in drift performance. In addition, it is not uncommon for a speaker- microphone or headset accessory to affect the near-field radiated performance as well as the drift. We cannot see the difference because Body-Worn SAR is not tested without an accessory and a Face-Held test is not tested with an accessory. We can see clearly that the SAR test with the highest drift for this device was the Body-Worn Speaker-Micrphone Antenna test at mid channel. The drift was -1.14 dB which translates to a 30% increase in the SAR result according to our scaling method (adding the drift to the SAR result). We have determined that it is an unavoidable consequence of SAR testing a high power PTT radio given the time it takes to measure the volume required for an accurate SAR value. EMC Response: No power drift was determined during initial power measurements. Although, conducted antenna port measurements were taken using only short transmissions for each measurements as well as radiated measurements. The battery was refreshed often and measurements resumed at the same frequencies to assure no deviations in amplitudes. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX L: EXTERNAL PHOTOGRAPHS PHOTOGRAPH 23: RADIO FRONT Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 24: RADIO BACK Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 25: RADIO ACCESSORY CONNECTOR SIDE Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 26: RADIO TOP Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 27: RADIO PTT SIDE
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX E: LABEL AND LABEL LOCATION PHOTOGRAPH 1: FCC ID / IC ID LABEL AND LOCATION Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 2: RF LABEL AND LOCATION
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX M: INTERNAL PHOTOGRAPHS PHOTOGRAPH 28: CHASSIS WITH SHIELDS Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 29: CHASSIS WITH SHIELDS REMOVED Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 30: RF AND LOGIC BOARD BACK OUT OF CHASSIS Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 31: LOGIC BOARD BOTTOM Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 32: LOGIC BOARD TOP Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 33: RF BOARD BOTTOM Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 34: RF BOARD TOP Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 35: USER INTERFACE BOARD IN FRONT COVER Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 36: USER INTERFACE BOARD BACK Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 PHOTOGRAPH 37: USER INTERFACE BOARD FRONT
Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 APPENDIX A: RF EXPOSURE Please see the SAR Evaluation that follows. © 2004 Celltech Labs Inc. 1 of 20 Test Report S/N: 111504ATH-T589-S90U Test Date(s): December 11-12, 2004 Test Type: FCC/IC SAR Evaluation Performed By: Spencer Watson Compliance Technologist Celltech Labs Inc. Reviewed By: Russell W. Pipe Senior Compliance Technologist Celltech Labs Inc. Celltech Labs Inc. declares under its sole responsibility that this wireless portable device has demonstrated compliance with the Specific Absorption Rate (SAR) RF exposure requirements specified in FCC 47 CFR §2.1093 and Health Canada’s Safety Code 6. The device was tested in accordance with the measurement standards and procedures specified in FCC OET Bulletin 65, Supplement C (Edition 01-01) and Industry Canada RSS-102 Issue 1 (Provisional) for the Occupational / Controlled Exposure environment. All measurements were performed in accordance with the SAR system manufacturer recommendations. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Labs Inc. The results and statements contained in this report pertain only to the device(s) evaluated. DECLARATION OF COMPLIANCE SAR RF EXPOSURE EVALUATION Test Lab CELLTECH LABS INC. Testing and Engineering Services 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250-448-7047 Fax: 250-448-7046 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information E.F. JOHNSON CO. 123 N. State Street Waseca, MN 56093 United States FCC IDENTIFER: ATH2425141 IC IDENTIFIER: 933B-2425141 Model(s): 5140 / 5141 Rule Part(s): FCC 47 CFR §2.1093; IC RSS-102 Issue 1 (Provisional) Test Procedure(s): FCC OET Bulletin 65, Supplement C (Edition 01-01) Device Classification: Licensed Non-Broadcast Transmitter Held to Face (TNF) Device Description: Portable FM UHF PTT Radio Transceiver Modulation Type: FM (UHF) Tx Frequency Range: 450 - 512 MHz Max. RF Output Power Measured: 36.75 dBm Conducted (450 MHz) 36.68 dBm Conducted (480 MHz) 36.78 dBm Conducted (512 MHz) Antenna Type(s) Tested: ¼- Wave Whip (P/N: 501-0017-107) Battery Type(s) Tested: NiMH 7.5 V 3600 mAh (P/N: 587-5100-360) Body-Worn Accessories Tested: Speaker-Microphone with Antenna (P/N: 589-0015-058) Speaker-Microphone (P/N: 589-0015-057) Boom-Microphone Headset (P/N: 589-0015-059) Plastic Belt-Clip with Metal Spring (P/N: 585-5100-128) Max. SAR Levels Evaluated: Face-held: 1.69 W/kg (50% Duty Cycle) Body-worn: 4.64 W/kg (50% Duty Cycle) © 2004 Celltech Labs Inc. 2 of 20 Test Report S/N: 111504ATH-T589-S90U Test Date(s): December 11-12, 2004 Test Type: FCC/IC SAR Evaluation TABLE OF CONTENTS 1.0INTRODUCTION.....................................................................3 2.0DESCRIPTION OF DUT............................................................ 3 3.0SAR MEASUREMENT SYSTEM................................................ 4 4.0MEASUREMENT SUMMARY..................................................... 5 5.0DETAILS OF SAR EVALUATION............................................... 6 6.0EVALUATION PROCEDURES................................................... 6 7.0SYSTEM PERFORMANCE CHECK............................................. 7 8.0SIMULATED EQUIVALENT TISSUES......................................... 8 9.0SAR SAFETY LIMITS............................................................... 8 10.0ROBOT SYSTEM SPECIFICATIONS........................................... 9 11.0PROBE SPECIFICATION.......................................................... 10 12.0PLANAR PHANTOM................................................................ 10 13.0VALIDATION PHANTOM........................................................... 10 14.0DEVICE HOLDER.................................................................... 10 15.0TEST EQUIPMENT LIST........................................................... 11 16.0MEASUREMENT UNCERTAINTIES............................................ 12-13 17.0REFERENCES........................................................................14 APPENDIX A - SAR MEASUREMENT DATA............................................... 15 APPENDIX B - SYSTEM PERFORMANCE CHECK DATA............................ 16 APPENDIX C - SYSTEM VALIDATION PROCEDURES................................. 17 APPENDIX D - PROBE CALIBRATION...................................................... 18 APPENDIX E - MEASURED FLUID DIELECTRIC PARAMETERS................... 19 APPENDIX F - SAR TEST SETUP & DUT PHOTOGRAPHS.......................... 20 Applicant: E.F. Johnson Co. FCC ID: ATH2425141 IC ID: 933B-2425141 Model(s):5140 / 5141 Portable FM UHF PTT Radio Transceiver 450 - 512 MHz 2004 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the written permission of Celltech Labs Inc. 3 of 20 Test Report S/N: 111504ATH-T589-S90U Test Date(s): December 11-12, 2004 Test Type: FCC/IC SAR Evaluation This measurement report demonstrates compliance of the E.F. Johnson Co. Model(s): 5140/5141 Portable FM UHF PTT Radio Transceiver FCC ID: ATH2425141 with the SAR (Specific Absorption Rate) RF exposure requirements specified in FCC 47 CFR §2.1093 (see reference [1]), and Health Canada’s Safety Code 6 (see reference [2]) for the Occupational / Controlled Exposure environment. The measurement procedures described in FCC OET Bulletin 65, Supplement C (Edition 01-01) (see reference [3]) and IC RSS-102 Issue 1 (Provisional) (see reference [4]), were employed. A description of the product, ope…
Text truncated - open the document above for the full version.
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway Suite 1400 Herndon, VA 20170 Phone: 703-689-0368; Fax: 703-689-2056; Metro: 703-471-6441 CERTIFICATION APPLICATION REPORT FCC PART 90 & INDUSTRY CANADA RSS-119 Test Lab: Rhein Tech Laboratories, Inc. Phone: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 Herndon, VA 20170 Web Site: www.rheintech.com Applicant: E. F. Johnson Phone: 507-835-6276 299 Johnson Ave. Fax: 507-835-6666 P.O. Box 1249 Email: [email protected] Waseca, MN 56093-0514 Contact: John Oblak FCC ID: ATH2425141 FRN NUMBER: 0005-8136-88 MODEL: 242-514x RTL WORK ORDER NUMBER: 2004185 EQUIPMENT TYPE: UHF-H PTT RTL QUOTE NUMBER: QRTL04-374 DATE OF TEST REPORT: December 16, 2004 FCC Classification: TNF – Licensed Non-Broadcast Transmitter Held to Face FCC Rule Part(s): Part 90: Private Land Mobile Radio Services Industry Canada Standard: RSS-119: Land Mobile and Fixed Radio Transmitters and Receivers, 27.41 MHz to 960 MHz Frequency Range (MHz) Output Power (W) Frequency Tolerance (PPM, %, or Hz) Emission Designator 450 – 512 4.6 1.5 PPM 11K0F3E 450 - 512 4.6 1.5 PPM 16K0F3E 450 - 512 4.6 1.5 PPM 8K10F1E 450 - 512 4.6 1.5 PPM 8K10F1D We, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve compliance with these standards. Furthermore, there was no deviation from, additions to or exclusions from the FCC Part 2, FCC Part 90, Industry Canada RSS-119, ANSI/TIA-603-B-2002 and ANSI/TIA/EIA 603-1. Signature: Date: December 16, 2004 Typed/Printed Name: Desmond A. Fraser Position: President Signature: Date: December 16, 2004 Typed/Printed Name: Daniel Baltzell Position: Test Engineer Rhein Tech Laboratories Report #: 2004185 360 Herndon Parkway FCC ID: ATH2425141 Suite 1400 Model: 242-514x Herndon, VA 20170 Standards: FCC Part 90 &IC RSS-119 http://www.rheintech.com Date: December 16, 2004 TABLE OF CONTENTS 1 GENERAL INFORMATION ...................................................................................................................................6 1.1 SCOPE .........................................................................................................................................................6 1.2 TEST FACILITY............................................................................................................................................6 1.3 RELATED SUBMITTAL(S)/GRANT(S) .........................................................................................................6 2 EQUIPMENT INFORMATION................................................................................................................................7 2.1 TEST SYSTEM DETAILS.............................................................................................................................7 2.2 WORST CASE CONFIGURATION OF TESTED SYSTEM..........................................................................8 3 DC VOLTAGES AND CURRENTS - §2.1033(C)(8) ..............................................................................................8 4 RF POWER OUTPUT - §2.1046 / RSS-119 §6.2...................................................................................................9 4.1 ANSI/TIA-603-B-2002, SECTION 2.2.1 TEST PROCEDURE ......................................................................9 4.2 RF POWER OUTPUT TEST EQUIPMENT ..................................................................................................9 4.3 RF POWER OUTPUT TEST DATA ............................................................................................................10 5 MODULATION CHARACTERISTICS - §2.1047 TEST PROCEDURE / RSS-119 §6.6 ......................................11 5.1 MODULATION CHARACTERISTICS TEST EQUIPMENT.........................................................................11 6 MODULATION CHARACTERISTICS - AUDIO FREQUENCY RESPONSE - §2.1047(A)..................................12 6.1 TEST PROCEDURE...................................................................................................................................12 6.2 TEST DATA ................................................................................................................................................12 7 MODULATION CHARACTERISTICS - AUDIO LOW PASS FILTER RESPONSE - §2.1047(A)........................13 7.1 TEST PROCEDURE...................................................................................................................................13 7.2 TEST DATA ................................................................................................................................................13 8 MODULATION CHARACTERISTICS - MODULATION LIMITING §2.1047(B)...................................................14 8.1 TEST PROCEDURE...................................................................................................................................14 8.2 TEST DATA ................................................................................................................................................14 9 OCCUPIED BANDWIDTH - §2.1049 / RSS-119 §6.4..........................................................................................18 9.1 OCCUPIED BANDWIDTH - §2.1049 TEST PROCEDURE ........................................................................18 9.2 OCCUPIED BANDWIDTH TEST EQUIPMENT..........................................................................................18 9.3 OCCUPIED BANDWIDTH TEST DATA .....................................................................................................19 10 SPURIOUS EMISSIONS AT ANTENNA TERMINAL - §2.1051 / RSS-119 §6.3 ...........................................22 10.1 SPURIOUS EMISSIONS AT ANTENNA TERMINAL - §2.1051 TEST PROCEDURE .....…
Text truncated - open the document above for the full version.
360 Herndon Parkway, Suite 1400 · Herndon, Virginia · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 9 | 450 MHz - 512 MHz | 4.6 W | 8K10F1E | 1.5 ppm |

DUAL BAND VHF AND 700/800 MHz MOBILE TRANSCEIVER
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
VP 600 UHF Land Mobile Radio Transceiver
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Portable VHF Push-To-Talk (PTT) Radio Transceiver
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Vantage 700/800 MHz Portable Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
700 MHz LAND MOBILE REPEATER
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter