Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Nov 23, 2010
Application Purpose
Original Equipment
Date of Application
Nov 23, 2010
Equipment Note
PORTABLE MULTIBAND 2-WAY RADIO
Frequency Range
851.00000000 - 869.00000000
Company
Motorola Solutions, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

APX 6000 User Guide Model 1.5 68012001081-A English mASTRO ® APX™ 6000 Series Digital Portable RadiosQuick Reference Card Product Safety and RF Exposure Compliance ATTENTION! This radio is restricted to occupational use only to satisfy FCC RF energy exposure requirements. Before using this product, read the RF energy awareness information and operating instructions in the Product Safety and RF Exposure booklet enclosed with your radio (Motorola Publication part number 6881095C98) to ensure compliance with RF energy exposure limits. Radio Controls Radio On/OffZones and Channels Receiving and TransmittingSending an Emergency Alarm To exit emergency at any time, press and hold the Emergency button. Before using this product, read the operating instructions for safe usage contained in the Product Safety and RF Exposure booklet enclosed with your radio. !  PICTURE TO BE REPLACED WITH APX 6000 MODEL 1.5 • On – On/Off/Volume knob clockwise. • Off – On/Off/Volume knob counterclockwise. • Zone – Zone switch to desired zone. • Channel – Channel switch to desired channel. PICTURE TO BE REPLACED WITH APX 6000 MODEL 1.5 1 Select zone/channel. 2 Listen for a transmission.ORPress and hold Volume Set button. ORPress Monitor button and listen for activity. 3 Adjust volume, if necessary. 4 Press the PTT button to transmit; release to receive. 1 Press the Emergency button. 2 The display shows EMERGNCY and the current zone/channel. A short, medium-pitched tone sounds, and the LED rapidly blinks red. 3 When acknowledgment is received, you hear four beeps; alarm ends; and radio exits emergency. *PMLN5715A* PMLN5715A © 2010 by Motorola, Inc. All Rights Reserved. 06/101301 E. Algonquin Rd., Schaumburg,IL 60196-1078, U.S.A. English Sending an Emergency Call To exit emergency at any time, press and hold the Emergency button. Sending a Silent Emergency Call To exit emergency at any time, press and hold the Emergency button. Display Status Icons 1 Press the Emergency button. 2 Press and hold the PTT button. Speak clearly into the microphone. 3 Release the PTT button to end call. 4 Press and hold Emergency button to exit emergency. 1 Press the Emergency button. 2 The display does not change; the LED does not light up, and there is no tone. 3 Silent emergency c ontinues until you: Press and hold the Emergency button to exit emergency state.ORPress and release the PTT button to exit silent emergency mode and enter regular emergency (alarm, call, or alarm with call) mode. Blinks when the battery is low.The more stripes, the stronger the signal strength for the current site (trunking only).Direct radio to radio communication or connected through a repeater.On = Direct Off = Repeater This channel is being monitored.L = Radio is set at Low power. H = Radio is set at High power. Scanning a scan list.Blinking dot = Detects activity on the Priority-One Channel during scan. Steady dot = Detects activity on the Priority-Two Channel during scan. The vote scan feature is enabled. U vV O M H OR L i j k On = Secure operation. Off = Clear operation. Blinking = Receiving an encrypted voice call. On steady = View mode Blinking = Program mode Zone Bank 1A = Radio is in Zone 1. B = Radio is in Zone 2. C = Radio is in Zone 3. Zone Bank 2D = Radio is in Zone 4. E = Radio is in Zone 5. F = Radio is in Zone 6. m A or B or C D or E or F Declaration of Conformity English i Declaration of Conformity This declaration is applicable to your radio only if your radio is labeled with the FCC logo shown below. DECLARATION OF CONFORMITYPer FCC CFR 47 Part 2 Section 2.1077(a)Responsible Party Name: Motorola, Inc.Address: 1301 East Algonquin Road, Schaumburg, IL 60196-1078, U.S.A.Phone Number: 1-800-927-2744Hereby declares that the product: Model Name: APX 6000 conforms to the following regulations: FCC Part 15, subpart B, section 15.107(a), 15.107(d) and section 15.109(a) Class B Digital DeviceAs a personal computer peripheral, this device complies with Part 15 of the FC C Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Declaration of Conformity English ii Note: This equipment has been tested and found to comply with the li mits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, us es and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference wi ll not occur in a particular installation. If this equipment does cause harmful interference to radi o or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit differ ent from that to which the receiver is connected. • Consult the dealer or an experienc ed radio/TV technician for help. Contents English iii ContentsThis User Guide contains all the information you need to use the AP X™ 6000 Series Digital P ortable Radios.Declaration of Conformity . . . . . . . . . . . . . . . . . .iImportant Safety Information . . . . . . . . . . . . . vii P roduct Safety and RF Exposure Compliance . . . vii Software Version . . . . . . . . . . . . . . . . . . . . . . . viiComputer Software Copyrights . . . . . . . . . . .viiiDocumentation Copyrights . . . . . . . . . . . . . . .viiiDisclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viiiGetting Started . . . . . . . . . . . . . . . . . . . . . . . . . . 1 How to Use This Guide . . . .…

Text truncated - open the document above for the full version.

Users Manual

English Product Safety and RF Energy Exposure Booklet for Portable Two-Way Radios The information provided in this document supersedes the general safety information contained in user guides published prior to February 2002. BEFORE USING THIS RADIO, READ THIS BOOKLET WHICH CONTAINS IMPORTANT OPERATING INSTRUCTIONS FOR SAFE USAGE AND RF ENERGY AWARENESS AND CONTROL INFORMATION AND OPERATIONAL INSTRUCTIONS FOR COMPLIANCE WITH RF ENERGY EXPOSURE LIMITS IN APPLICABLE NATIONAL AND INTERNATIONAL STANDARDS. ALSO READ THE OPERATIONAL INSTRUCTIONS FOR SAFE USAGE. FOR RADIOS THAT HAVE BEEN APPROVED AS INTRINSICALLY SAFE, READ THE INSTRUCTIONS AND INFORMATION ON INTRINSIC SAFETY ON PAGE 10 OF THIS BOOKLET. C a u t i o n © 2007 – 2009 by Motorola, Inc. All rights reserved. 06/09 1301 E. Algonquin Rd., Schaumburg, IL 60196-1078, U.S.A. *6881095C98* 6881095C98-E *NNTN7223B* NNTN7223B 6881095C98-E.book Page 1 Monday, June 22, 2009 11:27 PM 2 English RF Energy Exposure Awareness and Control Information and Operational Instructions for Occupational Use NOTICE: This radio is intended for use in occupational/controlled conditions where users have full knowledge of their exposure and can exercise control over their exposure to meet the occupational limits in FCC and International standards. This radio device is NOT authorized for general population consumer use. This two-way radio uses electromagnetic energy in the radio frequency (RF) spectrum to provide communications between two or more users over a distance. It uses radio frequency (RF) energy or radio waves to send and receive calls. RF energy is one form of electromagnetic energy. Other forms include, but are not limited to, sunlight and x-rays. RF energy, however, should not be confused with these other forms of electromagnetic energy, which when used improperly, can cause biological damage. Very high levels of x-rays, for example, can damage tissues and genetic material. Experts in science, engineering, medicine, health, and industry work with organizations to develop standards for safe exposure to RF energy. These standards provide recommended levels of RF exposure for both workers and the general public. These recommended RF exposure levels include substantial margins of protection. All Motorola two-way radios are designed, manufactured, and tested to ensure they meet government-established RF exposure levels. In addition, manufacturers also recommend specific operating instructions to users of two- way radios. These instructions are important because they inform users about RF energy exposure and provide simple procedures on how to control it. 6881095C98-E.book Page 2 Monday, June 22, 2009 11:27 PM 3 English Please refer to the following websites for more information on what RF energy exposure is and how to control your exposure to assure compliance with established RF exposure limits: http://www.fcc.gov/oet/rfsafety/rf-faqs.html http://www.osha.gov/SLTC/radiofrequencyradiation/index.html Federal Communication Commission (FCC) Regulations The FCC rules require manufacturers to comply with the FCC RF energy exposure limits for portable two-way radios before they can be marketed in the U.S. When two-way radios are used as a consequence of employment, the FCC requires users to be fully aware of and able to control their exposure to meet occupational requirements. Exposure awareness can be facilitated by the use of a product label directing users to specific user awareness information. Your Motorola two-way radio has a RF Exposure Product Label. Also, your Motorola user manual, or separate safety booklet includes information and operating instructions required to control your RF exposure and to satisfy compliance requirements. Compliance with RF Exposure Standards Your Motorola two-way radio is designed and tested to comply with a number of national and International standards and guidelines (listed below) for human exposure to radio frequency electromagnetic energy. This radio complies with the IEEE (FCC) and ICNIRP exposure limits for occupational/controlled RF exposure environments at operating duty factors of up to 50% talk-50% listen and is authorized by the FCC for occupational use only. In terms of measuring RF energy for compliance with these exposure guidelines, your radio generates measurable RF energy only while it is transmitting (during talking), not when it is receiving (listening) or in standby mode. 6881095C98-E.book Page 3 Monday, June 22, 2009 11:27 PM 4 English NOTE:The approved batteries, supplied with this radio, are rated for a 5-5-90 duty factor (5% talk-5% listen-90% standby) even though this radio complies with FCC occupational exposure limits and may operate at duty factors of up to 50% talk. Your Motorola two-way radio complies with the following RF energy exposure standards and guidelines: • United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 2 sub-part J • American National Standards Institute (ANSI)/Institute of Electrical and Electronic Engineers (IEEE) C95. 1-1992 • Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999 Edition • Institute of Electrical and Electronic Engineers (IEEE) C95.1-2005 Edition • International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998 • Ministry of Health (Canada) Safety Code 6. Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz, 1999 • Australian Communications Authority Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard, 2003 • ANATEL ANNEX to Resolution No. 303 of July 2, 2002 "Regulation of limitation of exposure to electrical, magnetic and electromagnetic fields in the radio frequency range between 9 KHz and 300 GHz" and "Attachment to resolution # 303 from July 2, 2002" 6881095C98-E.book Page 4 Monday, June 22, 2009 11:27 PM 5 English RF Exposure Compliance and Control Guidelines and Operating Instructions To control your exposure and ens…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant: Motorola FCC ID: AZ489FT5859 Statement of Certification The technical data supplied with this application, having been taken under my supervision is hereby duly certified. The following is a statement of my qualifications: 1) BSEE Purdue University 2) 15 years experience in the development, testing and certification of Land Mobile Communications Products NAME: Carlos Camps SIGNATURE: /s/ Carlos Camps (signed) DATE: 1 November 2010 POSITION: Engineering Section Manager I hereby certify that the above application was prepared under my direction and that to the best of my knowledge and belief, the facts set forth in the application and accompanying technical data are true and correct: NAME: Chris Ganio SIGNATURE: /s/ Chris Ganio (signed) DATE: 1 November 2010 POSITION: Engineering Manager EXHIBIT 2

Cover Letter(s)

FCC ID: AZ489FT5859 ______________________________________________________________________________ Motorola, Inc. 8000 West Sunrise Boulevard, Fort Lauderdale, Florida 33322 Date: 18 th November 2010 Office of Engineering and Technology Laboratory Division Equipment Authorization Branch Federal Communications Commission Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Subject: Application for Certification of Transmitter with FCC ID: AZ489FT5859, APX6000. Dear Sir or Madam: Motorola Inc, 8000 West Sunrise Boulevard, Fort Lauderdale, Florida, herein submits application for Certification of the subject transmitter. The APX6000 radio is designed for conventional and digital voice with data applications in 6.25e kHz, 12.5 kHz and 25 kHz systems. This Portable Radio transmitter has capabilities for clear and coded communications with a variable transmit power operating within the following frequency ranges: 700 MHz band: 1.0 – 2.99 Watts (30 – 34.7dBm) 800 MHz band: 1.0 – 3.6 Watts (30 – 35.6dBm) The subject transmitter complies with Section 90.203 of the Rules in that the operator cannot directly program transmit frequencies using the unit's normally accessible external controls. A complete application for certification is enclosed. If you require any additional information, please contact me at (954) 723-5793 Sincerely, /s/ Mike Ramnath (signed) Manager, Regulatory Compliance Tel: (954) 723-5793 E-mail: [email protected] EXHIBIT 13

Cover Letter(s)

FCC ID: AZ489FT5859 ______________________________________________________________________________ 8000 West Sunrise Boulevard, Fort Lauderdale, Florida 33322 CONFIDENTIALITY REQUESTED 18 th November 2010 Office of Engineering and Technology Laboratory Division Equipment Authorization Branch Federal Communications Commission Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Subject: Application for Certification of Transmitter with FCC ID: AZ489FT5859, APX6000. Dear Sir or Madam: Motorola is requesting that Exhibit 4 (Circuit Descriptions), Exhibit 5 (Schematic Diagrams), Exhibit 10a (Parts List and Tune-Up Procedures), Exhibit 10b (Exploded Diagrams with Parts List), and Exhibit 12 (Operational Description) not be made routinely available for public inspection. Motorola considers the information in these exhibits to be classified as trade secrets, pursuant to 47 CFR Section 0.457(d) and Section 552(b)(4) of the Freedom of Information Act. Please mark Exhibits 4, 5, 10a, 10b, and 12 as “Confidential.” Please contact me if you require any additional information. Sincerely, /s/ Mike Ramnath (signed) Manager, Regulatory Compliance Tel: (954) 723-5793 E-mail: [email protected] EXHIBIT 13B

External Photos

Applicant: Motorola FCC ID: AZ489FT5859 External Photographs The following photographs are attached. Exhibit 1. Front view. 3A 2. Back view with battery. 3B 3. Front view (FCC label location). 3C 4. Side view (Right). 3D 5. Side view (Left). 3E 6. Top view (Controls). 3F EXHIBIT 3 Applicant: Motorola FCC ID: AZ489FT5859 FRONT VIEW EXHIBIT 3A Applicant: Motorola FCC ID: AZ489FT5859 BACK VIEW WITH BATTERY EXHIBIT 3B Applicant: Motorola FCC ID: AZ489FT5859 FRONT VIEW (FCC LABELS) EXHIBIT 3C Applicant: Motorola FCC ID: AZ489FT5859 SIDE VIEW (RIGHT) EXHIBIT 3D Applicant: Motorola FCC ID: AZ489FT5859 SIDE VIEW (LEFT) EXHIBIT 3E Applicant: Motorola FCC ID: AZ489FT5859 TOP VIEW EXHIBIT 3F

ID Label/Location Info

Applicant: Motorola FCC ID: AZ489FT5859 Identification Label LOCATION See the Attached Photograph or Sketch X Back of Radio Back of Radio under Belt Clip TYPE X The label is a paper polyester film laminate with a pressure sensitive adhesive backing. The adhesive is a permanent type acrylic with a minimum peel strength of 40 oz/inch. MARKINGS (TEXT) X See the Attached Photograph and Exhibit 3C for the actual location of the FCC label on the device. Label Attached Below. See Attached Drawing. EXHIBIT 1 Applicant: Motorola FCC ID: AZ489FT5859 General Information I. Production Plans Quantity production is planned. II. Application References Reference is made to the following Motorola "Application References" 1. Portable Products and their application. 2. Portable Products Transmitter Modulations Methods. 3. Motorola EMC Laboratory-Plantation, Florida III. Data Submittal Procedure: Data is supplied in accordance with Part 2, Sub-part J of the Commissions’ rules. IV. Applicable References: • Reference Certification FCC ID: AZ489FT5859 • EIA/TIA-603 Land Mobile FM or PM Communications Equipment Measurement and Performance Standards • CFR 47, Rule Part 2, 15, and 90 EXHIBIT 1A

Internal Photos

Applicant: Motorola FCC ID: AZ489FT5859 Internal Photographs The following photographs are attached. Exhibit 1. RF board with Shields (Top). 9A 2. RF board without Shields (Top). 9B 3. RF board with Shields (Bottom). 9C 4. RF board without Shields (Bottom). 9D 5. Vocon board with Shields (Top). 9E 6. Vocon board without Shields (Top). 9F 7. Vocon board with Shields (Bottom). 9G 8. Vocon board without Shields (Bottom). 9H 9. Expander board with Shields (Top). 9I 10. Expander board without Shields (Top). 9J 11. Expander board with Shields (Bottom). 9K 12. Expander board without Shields (Bottom). 9L EXHIBIT 9 Applicant: Motorola FCC ID: AZ489FT5859 RF board with Shields (Top) EXHIBIT 9A Applicant: Motorola FCC ID: AZ489FT5859 RF board without Shields (Top) EXHIBIT 9B Applicant: Motorola FCC ID: AZ489FT5859 RF board with Shields (Bottom) EXHIBIT 9C Applicant: Motorola FCC ID: AZ489FT5859 RF board without Shields (Bottom) EXHIBIT 9D Applicant: Motorola FCC ID: AZ489FT5859 Vocon board with Shields (Top) EXHIBIT 9E Applicant: Motorola FCC ID: AZ489FT5859 Vocon board without Shields (Top) EXHIBIT 9F Applicant: Motorola FCC ID: AZ489FT5859 Vocon board with shields board (Bottom) EXHIBIT 9G Applicant: Motorola FCC ID: AZ489FT5859 Vocon board without shields board (Bottom) EXHIBIT 9H Applicant: Motorola FCC ID: AZ489FT5859 Expander board with shields board (Bottom) EXHIBIT 9I Applicant: Motorola FCC ID: AZ489FT5859 Expander board without shields board (Bottom) Applicant: Motorola FCC ID: AZ489FT5859 EXHIBIT 9J Expander board with shields board (Bottom) Applicant: Motorola FCC ID: AZ489FT5859 EXHIBIT 9K Expander board without shields board (Bottom)

RF Exposure Info

SR8654 EMS EME Form-SAR-Rpt-Rev. 10.03 Page 1 of 90 TESTING CERT # 2518.01 DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2 Enterprise Mobility Solutions EME Test Laboratory 8000 West Sunrise Blvd Fort Lauderdale, FL. 33322. Date of Report: 11/22/10 Report Revision: A Report ID: SAR rpt_H98UCD9PW5AN_Rev.A _101122_SR8654 * Refer to section 15 of part 1 for highest SAR summary results. The test results clearly demonstrate compliance with FCC Occupational/Controlled RF Exposure limits of 8 W/kg averaged over 1 gram per the requirements of 47 CFR 2.1093(d). The 10 grams result is not applicable to FCC filing. The test results clearly demonstrate compliance with ICNIRP (1998) Guidelines for limiting exposure in time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz), Health Physics 74, 494-522 RF Exposure limits of 10 W/kg averaged over 10grams of contiguous tissue. Responsible Engineer: Michael Sailsman (Senior Staff Eng.) Report Author: Michael Sailsman (Senior Staff Eng.) Date/s Tested: 7/22/10 – 8/18/10; 10/1/10-10/20/10 Manufacturer/Location: Motorola, Plantation Sector/Group/Div.: G&PS Date submitted for test: 7/23/10 DUT Description: 764-775 MHz and 794-805 MHz at 2.5 W, 806 -824 MHz and 851-870 MHz at 3 W, 6.25K/12.5K/25K, Basic Top Display Model. Capable of digital and analog FM transmission. Also capable of TDMA transmission. Test TX mode(s): CW (PTT) Max. Power output: 2.99 W (764 - 805 MHz), 3.6 W (806 - 870 MHz) Nominal Power: 2.5 W (764 - 805MHz), 3.0 W (806 - 870 MHz) Tx Frequency Bands: 764-775 MHz, 794-805 MHz, 806-824 MHz, 851-870 MHz Signaling type: FM and TDMA Model(s) Tested: H98UCD9PW5AN (MNUF1002A) Model(s) Certified: H98UCD9PW5AN (MNUF1002A) Serial Number(s): NUF1003A0048 Classification: Occupational/Controlled FCC ID: AZ489FT5859 FCC Rule Part(s): 90; 764-775 MHz, 794-805 MHz, 806-824 MHz, 851-870 MHz IC: 109U-89FT5859 IC standard(s): RSS 102 issue 4; Safety Code 6 Based on the information and the testing results provided herein, the undersigned certifies that when used as stated in the operating instructions supplied, said product complies with the national and international reference standards and guidelines listed in section 3.0 of this report. This report shall not be reproduced without written approval from an officially designated representative of the Motorola EME Laboratory. I attest to the accuracy of the data and assume full responsibility for the completeness of these measurements. This reporting format is consistent with the suggested guidelines of the TIA TSB-150 December 2004. The results and statements contained in this report pertain only to the device(s) evaluated. Signature on file – Deanna Zakharia Deanna Zakharia EMS EME Lab Senior Resource Manager, Laboratory Director Approval Date: 11/22/2010 Certification Date: 11/22/2010 Certification No.: L1101127P SR8654 EMS EME Form-SAR-Rpt-Rev. 10.03 Page 2 of 90 Part 1 of 2 1.0 Introduction.........................................................................................4 2.0 Abbreviations / Definitions.................................................................4 3.0 Referenced Standards and Guidelines ................................................4 4.0 SAR Limits .........................................................................................5 5.0 SAR Result Scaling Methodology ......................................................5 6.0 Description of Device Under Test (DUT) ..........................................6 7.0 Optional Accessories and Test Criteria ..............................................6 7.1 Antennas ....................................................................................7 7.2 Batteries .....................................................................................7 7.3 Body worn Accessories .............................................................7 7.4 Audio Accessories .....................................................................8 8.0 Description of Test System.................................................................8 8.1 Description of Robotics/Probes/Readout Electronics................8 8.2 Description of Phantom(s) .........................................................9 8.2.1 Dual Flat Phantom .........................................................9 8.2.2 SAM Phantom................................................................9 8.2.3 Elliptical Flat Phantom ..................................................9 8.3 Description of Simulated Tissue ................................................9 9.0 Additional Test Equipment ...............................................................10 10.0 SAR Measurement System Verification ...........................................11 10.1 Equivalent Tissue Test Results ................................................11 10.2 System Check Test Results ......................................................12 11.0 Environmental Test Conditions ........................................................13 12.0 DUT Test Methodology ....................................................................14 12.1 Measurements ..........................................................................14 12.2 DUT Configuration(s)..............................................................14 12.3 Device Positioning Procedures ................................................14 12.3.1 Body .............................................................................14 12.3.2 Head .............................................................................14 12.3.3 Face ..............................................................................14 12.4 DUT Test Channels..................................................................15 12.5 DUT Test Plan ........................................................................15 12.5.1 General Test Flowchart................................................16 13.0 DUT Test Data ...........................................…

Text truncated - open the document above for the full version.

RF Exposure Info

SR8654 EMS EME Form-SAR-Rpt-Rev. 10.00 Page 1 of 85 TESTING CERT # 2518.01 DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 2 of 2 Enterprise Mobility Solutions EME Test Laboratory 8000 West Sunrise Blvd Fort Lauderdale, FL. 33322. Date of Report: 11/22/10 Report Revision: A Report ID: SAR rpt_H98UCD9PW5AN_Rev.A _101122_SR8654 * Refer to section 15 of part 1 for highest SAR summary results. The test results clearly demonstrate compliance with FCC Occupational/Controlled RF Exposure limits of 8 W/kg averaged over 1 gram per the requirements of 47 CFR 2.1093(d). The 10 grams result is not applicable to FCC filing. The test results clearly demonstrate compliance with ICNIRP (1998) Guidelines for limiting exposure in time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz), Health Physics 74, 494-522 RF Exposure limits of 10 W/kg averaged over 10grams of contiguous tissue. Responsible Engineer: Michael Sailsman (Senior Staff Eng.) Report Author: Michael Sailsman (Senior Staff Eng.) Date/s Tested: 7/22/10 – 8/18/10; 10/1/10-10/20/10 Manufacturer/Location: Motorola, Plantation Sector/Group/Div.: G&PS Date submitted for test: 7/23/10 DUT Description: 764-775 MHz and 794-805 MHz at 2.5 W, 806 -824 MHz and 851-870 MHz at 3 W, 6.25K/12.5K/25K, Basic Top Display Model. Capable of digital and analog FM transmission. Also capable of TDMA transmission. Test TX mode(s): CW (PTT) Max. Power output: 2.99 W (764 - 805 MHz), 3.6 W (806 - 870 MHz) Nominal Power: 2.5 W (764 - 805MHz), 3.0 W (806 - 870 MHz) Tx Frequency Bands: 764-775 MHz, 794-805 MHz, 806-824 MHz, 851-870 MHz Signaling type: FM and TDMA Model(s) Tested: H98UCD9PW5AN (MNUF1002A) Model(s) Certified: H98UCD9PW5AN (MNUF1002A) Serial Number(s): NUF1003A0048 Classification: Occupational/Controlled FCC ID: AZ489FT5859 FCC Rule Part(s): 90; 764-775 MHz, 794-805 MHz, 806-824 MHz, 851-870 MHz IC: 109U-89FT5859 IC standard(s): RSS 102 issue 4; Safety Code 6 Based on the information and the testing results provided herein, the undersigned certifies that when used as stated in the operating instructions supplied, said product complies with the national and international reference standards and guidelines listed in section 3.0 of this report. This report shall not be reproduced without written approval from an officially designated representative of the Motorola EME Laboratory. I attest to the accuracy of the data and assume full responsibility for the completeness of these measurements. This reporting format is consistent with the suggested guidelines of the TIA TSB-150 December 2004. The results and statements contained in this report pertain only to the device(s) evaluated. Signature on file – Deanna Zakharia Deanna Zakharia EMS EME Lab Senior Resource Manager, Laboratory Director Approval Date: 11/22/2010 Certification Date: 11/22/2010 Certification No.: L1101127P SR8654 EMS EME Form-SAR-Rpt-Rev. 10.00 Page 2 of 85 Appendix D Test System Verification Scans The SAR value indicated on the Manufacturer’s Calibration certificate for dipole D835V2/435 was used to determine if the measured SAR values in the head-tissue liquid was within +/-10% from the Manufacturer’s value, per FCC KDB 450824. Since the Manufacturer’s Calibration certificate did not report any body-tissue SAR value, the system verification conducted with the body-tissue liquid using dipole D835V2/435 was carried out using the SAR target determined in the Motorola EMS laboratory according to the guidelines in the IEEE 1528-2003 and the IEC 62209-1(2005) standards, which define purpose and requirements for system check. These standards spell identical requirements for system check and specifically they state that [from IEEE 1528-2003]: “The system check is a check of repeatability to make sure that the system works correctly at the time of the compliance test. It is not a validation of the system with respect to external standards.” (...) “System checks are performed prior to compliance tests and the results must always be within ± 10% of the target value corresponding to the test frequency, liquid, and the source used. The target values are 1 g or 10 g averaged SAR values measured on systems having current system validation and calibration status, and using the system check setup as shown in Figure 14. These target values should be determined using a standard source.” (...) “The system check is a complete 1 g or 10 g averaged SAR measurement. The measured 1 g (or 10 g) averaged SAR value is normalized to the target input power of the standard source and compared with the previously determined target 1 g (or 10 g) value corresponding to the measurement frequency, the standard source, and the specific phantom. The difference from the previously recorded system check target values should be within ± 10%.” The method used in Motorola to define the dipole SAR targets fulfills the requirements of the standards. The targets are defined through measurements conducted…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Deanna Zakharia(Regulatory Compliance Manager)
[email protected]9547234707Fax: --

Test Firm

MotorolaWilliam Elliott
[email protected]954-723-5480Fax: 954-723-6383

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
49851 MHz - 869 MHz3 WNOTE 11.5 ppm
Confidentiality
Long Term
Grant Notes
Power listed is rated conducted. Maximum conducted output power is 2.5 Watts in the 700 MHz Band, and 3.0 Watts in the 800 MHz band per 90.205(s). Minimum output setting is 1W in all cases. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 2.5 cm separation between the device and the user�s body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 2.92 W/kg; Body: 7.62 W/kg accounting for a 50% duty cycle. Note 1: 16K0F3E, 11K0F3E, 8K10F1E, 8K10F1D, 8K10F1W, 20K0F1E

Other Applications from Motorola Solutions, Inc.

Portable two way radio - FCC ID AZ489FT4980 - Motorola Solutions, Inc.
AZ489FT4980

Portable two way radio

Sep 08, 2026

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
AZ489FT4981

Handheld Portable - TANAPA BPR 45 400-470 MHZ 4W NKP

Aug 14, 2026

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
Portable 2-Way Radio with Bluetooth, Bluetooth LE, WIFI 2.4GHz, WIFI 5GHz, LTE - FCC ID AZ489FT7187 - Motorola Solutions, Inc.
AZ489FT7187

Portable 2-Way Radio with Bluetooth, Bluetooth LE, WIFI 2.4GHz, WIFI 5GHz, LTE

Jul 13, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AZ499FT6031

Operation Critical Wireless Earpiece PTT

May 11, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2-way Portable Radio with BT, BTLE, WIFI, NFC and LTE - FCC ID AZ499FT5879 - Motorola Solutions, Inc.
AZ499FT5879

2-way Portable Radio with BT, BTLE, WIFI, NFC and LTE

Dec 19, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter