FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Canon Inc./
  3. AZD264

AZD264Digital Camera

Canon Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 23, 2026
Application Purpose
Original Equipment
Equipment Note
Digital Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Canon Inc.
Country
Japan

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

FCC/ISED E-Label Information Model: DS126991 A. Information to be displayed The information that will be displayed on the e-label and information that will remain in the user manual is show below: Information On E-label In Manual FCC ID number Yes Yes SDoC logo Yes No 15.19 statement (“This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”) Yes Yes Class A/B Digital Device user manual statements 1 No Yes SDoC declaration 1 No Yes Caution to the user that changes or modifications not expressly approved by the party responsible for compliance could void the user′s authority to operate the equipment 1 No Yes 1. If the e-label includes information typically included in the manual then the e- label shall clearly differentiate between information required to be on the device′s surface and information required to be in the manual-refer to 784748 D02 e labeling v02r01 Images of the e-label screen are provided below B. Access to the required information on the e-label Setup: 1. Press the Menu button to display the menu screen. 2. Operation ▲ ▼ ◀ ▶ Display the Sub menu. 3. Operation ▲ ▼ ◀ ▶ Select [Authentication Mark], then press OK. No special access codes or permissions are required to go through the above steps beyond entering a user-defined password to protect against unauthorized access to the device. 1. The information is stored on the device, no special accessories or supplemental plugins (e.g., a SIM/USIM card) are required to access the information. Yes. 2. Users are provided specific instructions on how to access the information. The information to the user is provided user manual stated on the website. C. Labeling for Importation and Purchasing 1. Products utilizing e-labels are required to have a physical label on the product at the time of importation, marketing and sales. For devices imported in bulk and not packaged individually, a removable adhesive label or, for devices in protective bags, a label on the bags is acceptable for this purpose. Any removable label shall be of a type intended to survive normal shipping and handling and must only be removed by the customer after purchase. For devices imported already in individual packages ready for sale, the information may alternatively be provided on the package. It shall contain: a. The FCC ID and/or the SDoC logo (if applicable); and b. Any other information required by specific rule to be provided on the surface of the product unless such information is permitted to be included in the User′s manual or other packaging inserts. The FCC ID logo are present on the product package. D. Other considerations 1. The above information must be programmed by the responsible party and the information must be secured in such a manner that third-parties cannot modify it. The e-label information is pre-programmed by the grantee. The user cannot modify the e-label information. 2. All the applicable regulatory information required on the packaging or user instructions must be provided according to the rules even if it is displayed electronically. Yes, it is provided.

ID Label/Location Info

Label Sample

RF Exposure Info

Report No.: 2640631R-SAUSV01S-A Page: 1 of 2 Appendix A. System Check Data Report No.: 2640631R-SAUSV01S-A Page: 2 of 2 Test Laboratory: DEKRA Date: 2026/05/18 System Performance Check_2450MHz-Head Communication System: UID 0, CW; Frequency: 2450 MHz Communication System PAR: 0 dB Medium parameters used: f = 2450 MHz; σ = 1.77 S/m; ε r = 38.88; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2011) DASY Configuration: • Probe: EX3DV4 - SN3698; ConvF(6.64, 6.51, 6.41) @ 2450 MHz; Calibrated: 2025/11/27 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1207; Calibrated: 2025/11/13 • Phantom: ELI 5.0; Type: QDOVA002AA; Serial: 1199 • Measurement SW: DASY52, Version 52.10 (4); Configuration/2450MHz-Head/Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 16.5 W/kg Configuration/2450MHz-Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 112.7 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 22.5 W/kg SAR(1 g) = 12.2 W/kg; SAR(10 g) = 6.12 W/kg Smallest distance from peaks to all points 3 dB below = 8.9 mm Ratio of SAR at M2 to SAR at M1 = 55% Maximum value of SAR (measured) = 19.1 W/kg

RF Exposure Info

Report No.: 2640631R-SAUSV01S-A Page: 1 of 2 Appendix B. Highest Measurement Data Report No.: 2640631R-SAUSV01S-A Page: 2 of 2 Test Laboratory: DEKRA Date: 2026/05/18 4_WLAN2.4GHz_802.11b-1M_CH11_Top_0mm_ANT Main Communication System: UID 0, WLAN 2.4G; Frequency: 2462 MHz Communication System PAR: 0 dB Medium parameters used: f = 2462 MHz; σ = 1.78 S/m; ε r = 38.83; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2011) DASY Configuration: • Probe: EX3DV4 - SN3698; ConvF(6.64, 6.51, 6.41) @ 2462 MHz; Calibrated: 2025/11/27 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1207; Calibrated: 2025/11/13 • Phantom: ELI 5.0; Type: QDOVA002AA; Serial: 1199 • Measurement SW: DASY52, Version 52.10 (4); Configuration/Flat/Area Scan (7x12x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.711 W/kg Configuration/Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 23.03 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.28 W/kg SAR(1 g) = 0.405 W/kg; SAR(10 g) = 0.154 W/kg Smallest distance from peaks to all points 3 dB below = 5.8 mm Ratio of SAR at M2 to SAR at M1 = 42.2% Maximum value of SAR (measured) = 0.883 W/kg

RF Exposure Info

Appendix D. Probe Calibration

RF Exposure Info

Appendix E. Dipole & Source Calibration

RF Exposure Info

Report No.: 2640631R-SAUSV01S-A Page: 1 of 26 Test report No.: 2640631R-SAUSV01S-A SAR Test Report Product Name Digital Camera Trademark Canon Model and /or type reference DS126991 Applicant ́s name / address Canon Inc. 16-1, Shimonoge 3-chome, Takatsu-ku, Kawasaki- shi, Kanagawa 213-8512, Japan Manufacturer ́s name Canon Inc. FCC ID AZD264 Applicable Standard IEEE 1528-2013 KDB 447498 D01 v06 KDB 865664 D01 v01r04 Test Result Max. SAR Measurement (1g) 2.4 GHz: 0.536 W/kg Verdict Summary IN COMPLIANCE Documented By (Supervisor / Jinn Chen) Tested By (Senior Engineer / Luke Cheng) Approved By (Assistant Manager / San Lin) Date of Receipt 2026/04/23 Date of Issue 2026/07/09 Report Version V1.0 Report No.: 2640631R-SAUSV01S-A Page: 2 of 26 INDEX Page 1. General Information ........................................................................................................ 5 1.1 EUT Description ................................................................................................. 5 1.2 Antenna List ....................................................................................................... 5 1.3 SAR Test Exclusion Calculation ......................................................................... 6 1.4 Test Environment ................................................................................................ 7 1.5 Measurement procedures................................................................................... 8 2. SAR Measurement System ............................................................................................. 9 2.1 DASY System Description .................................................................................. 9 2.2 Area Scans ....................................................................................................... 10 2.3 DASY E-Field Probe ......................................................................................... 11 2.4 DATA Acquisition Electronics (DAE) and Measurement Server ........................ 12 2.5 Robot ................................................................................................................ 13 2.6 Device Holder ................................................................................................... 13 2.7 Phantom ........................................................................................................... 14 3. Tissue Simulating Liquid .............................................................................................. 15 3.1 The composition of the tissue simulating liquid ................................................ 15 3.2 Tissue Calibration Result ..................................... ............................................. 15 3.3 Tissue Dielectric Parameters for Phantoms ..................................................... 16 4. Measurement Procedure ............................................................................................... 17 4.1 SAR System Check .......................................................................................... 17 4.2 SAR Measurement Procedure .......................................................................... 18 5. RF Exposure Limits ....................................................................................................... 19 6. Test Equipment List ...................................................................................................... 20 7. Measurement Uncertainty ............................................................................................. 22 8. Conducted Power Measurement (Including tolerance allowed for production unit) ................................................................................................................................ 24 9. Test Results ................................................................................................................... 25 9.1 Test Results Summary ..................................................................................... 25 Appendix A. System Check Data Appendix B. Highest measurement Data Appendix C. Test Setup Photographs Appendix D. Probe Calibration Data Appendix E. Dipole & Source Calibration Appendix F. Product Photos-Please refer to the file: 2640631R-Product Photos Report No.: 2640631R-SAUSV01S-A Page: 3 of 26 Competences and Guarantees DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA. General conditions 1. The test results relate only to the samples tested. 2. The test results shown in the test report are traceable to the national/international standard through the calibration report of the equipment and evaluated measurement uncertainty herein. 3. This report must not be used to claim product endorsement by TAF or any agency of the government. 4. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification Co., Ltd. 5. Measurement uncertainties evaluated for each testing system and associated connections are given here to pro…

Text truncated - open the document above for the full version.

Test Report

Date: 2026.5.6 Quectel KN35500 Antenna Report Version: 1.0 | Status: Released •Device Dimensions: - •Antenna Quantity: 1 •Network Standard and Frequency Band: pWIFI:2.4GHz pPerformance Requirements: üAntenna Efficiency>40%. Project Overview • Antenna Type: PCB antenna Version: 1.0 | Status: ReleasedPage 7 / 18 Passive Test •VSWR (Voltage Standing Wave Ratio) VSWR (Voltage Standing Wave Ratio): 2400–2500MHz < 2.6; 1 2 3 4 5 6 7 8 9 10 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 2 4 0 0 2 5 0 0 2 6 0 0 2 7 0 0 2 8 0 0 2 9 0 0 3 0 0 0 V S W R Frequency(MHz) VSWR A2 Version: 1.0 | Status: ReleasedPage 8 / 18 Passive Test •Efficiency Efficiency: 2400–2500MHz > 29.8%; 0 10 20 30 40 50 60 70 80 90 100 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 2 4 0 0 2 5 0 0 2 6 0 0 2 7 0 0 2 8 0 0 2 9 0 0 3 0 0 0 E f f i c i e n c y ( % ) Frequency(MHz) Efficiency A2 Version: 1.0 | Status: ReleasedPage 9 / 18 Passive Test •Average Gain Average Gain : 2400–2500MHz > -5.3 dB; -10 -8 -6 -4 -2 0 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 2 4 0 0 2 5 0 0 2 6 0 0 2 7 0 0 2 8 0 0 2 9 0 0 3 0 0 0 A V G G a i n ( d B i ) Frequency(MHz) AVG Gain A2 Version: 1.0 | Status: ReleasedPage 10 / 18 Passive Test •Peak Gain Peak Gain : 2400–2500MHz: -2.4 dBi; -8 -6 -4 -2 0 2 4 6 8 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 2 4 0 0 2 5 0 0 2 6 0 0 2 7 0 0 2 8 0 0 2 9 0 0 3 0 0 0 P e a k G a i n ( d B i ) Frequency(MHz) Peak Gain A2 www.quectel.com •Passive Data Passive Test Passive Test 2400MHz2410MHz*2450MHz2500MHz VSWR 2.02.12.32.6 Efficiency(%) 40.040.940.129.8 Average Gain(dB) -4.0-3.9-4.0-5.3 Peak gain(dBi) -2.5-2.4-2.8-4.7 "2410MHz*" indicates the frequency point corresponding to the maximum peak gain value within the frequency band. Version: 1.2 | Status: ReleasedPage 12 / 15 Passive Test •Radiation Pattern-A2 ANT 2450 MHz

Test Report

Report No.: 2640631R-RFUSV01S-A Page : 1 of 35 Appendix A. Test Result of AC Power Line Conducted Emission TX_n40_2437MHz_Line TX_n40_2437MHz_Neutral Report No.: 2640631R-RFUSV01S-A Page : 2 of 35 Appendix B. Test Result of Occupied Bandwidth & DTS Bandwidth Modulation Frequency (MHz) 99% Occupied Bandwidth (MHz) DTS Bandwidth (MHz) Limit (MHz) 99% Occupied Bandwidth DTS Bandwidth 802.11b (20MHz) 2412 13.87 10.04 - ≧ 0.5 2437 13.95 9.56 - ≧ 0.5 2462 13.87 9.60 - ≧ 0.5 802.11g (20MHz) 2412 16.26 15.04 - ≧ 0.5 2437 16.34 15.68 - ≧ 0.5 2462 16.26 15.08 - ≧ 0.5 802.11n (20MHz) 2412 17.62 15.96 - ≧ 0.5 2437 17.58 15.40 - ≧ 0.5 2462 17.46 15.64 - ≧ 0.5 802.11n (40MHz) 2422 35.16 31.36 - ≧ 0.5 2437 35.24 34.48 - ≧ 0.5 2452 35.32 32.56 - ≧ 0.5 Report No.: 2640631R-RFUSV01S-A Page : 3 of 35 For 99% Occupied Bandwidth: 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1 802.11b/20MHz/1M/2437MHz/Ch6/Ant.1 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1 802.11g/20MHz/6M/2437MHz/Ch6/Ant.1 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 4 of 35 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1 802.11n/20MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1 802.11n/40MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 5 of 35 For DTS Bandwidth: 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1 802.11b/20MHz/1M/2437MHz/Ch6/Ant.1 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1 802.11g/20MHz/6M/2437MHz/Ch6/Ant.1 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 6 of 35 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1 802.11n/20MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1 802.11n/40MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 7 of 35 Appendix C. Test Result of Maximum Peak Conducted Output Power Modulation Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Limit (dBm) Result 802.11b (20MHz) 2412 12.82 30.00 Pass 2437 13.04 30.00 Pass 2462 12.85 30.00 Pass 802.11g (20MHz) 2412 20.20 30.00 Pass 2437 19.87 30.00 Pass 2462 20.46 30.00 Pass 802.11n (20MHz) 2412 19.69 30.00 Pass 2437 19.70 30.00 Pass 2462 19.59 30.00 Pass 802.11n (40MHz) 2422 20.48 30.00 Pass 2437 20.22 30.00 Pass 2452 21.12 30.00 Pass Report No.: 2640631R-RFUSV01S-A Page : 8 of 35 Average for reference only Modulation Frequency (MHz) Maximum Conducted Output Power (dBm) Limit (dBm) Result 802.11b (20MHz) 2412 10.34 30.00 Pass 2437 10.55 30.00 Pass 2462 10.46 30.00 Pass 802.11g (20MHz) 2412 10.99 30.00 Pass 2437 10.90 30.00 Pass 2462 11.16 30.00 Pass 802.11n (20MHz) 2412 10.83 30.00 Pass 2437 10.62 30.00 Pass 2462 10.92 30.00 Pass 802.11n (40MHz) 2422 10.82 30.00 Pass 2437 10.84 30.00 Pass 2452 10.98 30.00 Pass Report No.: 2640631R-RFUSV01S-A Page : 9 of 35 Appendix D. Test Result of Maximum Power Spectral Density Modulation Frequency (MHz) Maximum Power Spectral Density (dBm/3kHz) Limit (dBm/3kHz) Result 802.11b (20MHz) 2412 -13.56 8.00 Pass 2437 -12.41 8.00 Pass 2462 -11.73 8.00 Pass 802.11g (20MHz) 2412 -10.65 8.00 Pass 2437 -12.84 8.00 Pass 2462 -10.16 8.00 Pass 802.11n (20MHz) 2412 -12.29 8.00 Pass 2437 -13.55 8.00 Pass 2462 -11.86 8.00 Pass 802.11n (40MHz) 2422 -15.02 8.00 Pass 2437 -14.26 8.00 Pass 2452 -14.80 8.00 Pass Report No.: 2640631R-RFUSV01S-A Page : 10 of 35 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1 802.11b/20MHz/1M/2437MHz/Ch6/Ant.1 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1 802.11g/20MHz/6M/2437MHz/Ch6/Ant.1 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 11 of 35 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1 802.11n/20MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1 802.11n/40MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 12 of 35 Appendix E. Test Result of Antenna Port Conducted Emission 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1 (Ref.) 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1 802.11b/20MHz/1M/2437MHz/Ch6/Ant.1 (Ref.) 802.11b/20MHz/1M/2437MHz/Ch6/Ant.1 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1 (Ref.) 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 13 of 35 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1 (Ref.) 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1 802.11g/20MHz/6M/2437MHz/Ch6/Ant.1 (Ref.) 802.11g/20MHz/6M/2437MHz/Ch6/Ant.1 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1 (Ref.) 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 14 of 35 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1 (Ref.) 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1 802.11n/20MHz/MCS0/2437MHz/Ch6/Ant.1 (Ref.) 802.11n/20MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1 (Ref.) 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 15 of 35 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1 (Ref.) 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1 802.11n/40MHz/MCS0/2437MHz/Ch6/Ant.1 (Ref.) 802.11n/40MHz/MCS0/2437MHz/Ch6/Ant.1 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1 (Ref.) 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1 Report No.: 2640631R-RFUSV01S-A Page : 16 of 35 802.11b/20MHz/1M/2412MHz/Ch1/Ant.1(Band Edge) 802.11b/20MHz/1M/2462MHz/Ch11/Ant.1(Band Edge) 802.11g/20MHz/6M/2412MHz/Ch1/Ant.1(Band Edge) 802.11g/20MHz/6M/2462MHz/Ch11/Ant.1(Band Edge) 802.11n/20MHz/MCS0/2412MHz/Ch1/Ant.1(Band Edge) 802.11n/20MHz/MCS0/2462MHz/Ch11/Ant.1(Band Edge) Report No.: 2640631R-RFUSV01S-A Page : 17 of 35 802.11n/40MHz/MCS0/2422MHz/Ch3/Ant.1(Band Edge) 802.11n/40MHz/MCS0/2452MHz/Ch9/Ant.1(Band Edge) Report No.: 2640631R-RFUSV01S-A Page: 18 of 35 Appendix F. Test Result of Radiated Emission TX_b_2412MHz_H TX_b_2412MHz_V TX_b_2437MHz_H TX_b_2437MHz_V Report No.: 2640631R-RFUSV01S-A Page: 19 of 35 TX_b_2462MHz_H TX_b_2462MHz_V TX_g_2412MHz_H TX_g_2412MHz_V Report No.: 2640631R-RFUSV01S-A Page: 20 of 35 TX_g_2437MHz_H TX_g_2437MHz_V TX_g_2462MHz_H TX_g_2462MHz_V Report No.: 2640631R-RFUSV01S-A Pag…

Text truncated - open the document above for the full version.

Test Report

Report No.: 2640631R-RFUSV01S-A Page: 1 of 23 Test Report No: 2640631R-RFUSV01S-A TEST REPORT FCC Rules & Regulations Product Name Digital Camera Brand Name Canon Model No. DS126991 FCC ID AZD264 Applicant ́s Name / Address Canon Inc. 16-1, Shimonoge 3-chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8512, Japan Manufacturer’s Name Canon Inc. Test Method Requested, Standard FCC CFR Title 47 Part 15 Subpart C Section 15.247 Verdict Summary IN COMPLIANCE Documented by Jinn Chen Approved by Alan Chen Date of Receipt 2026/04/23 Date of Issue 2026/07/09 Report Version V1.0 Report No.: 2640631R-RFUSV01S-A Page: 2 of 23 INDEX page Competences and Guarantees ................................................................................................................................ 4 General Conditions .................................................................................................................................................. 4 Revision History ....................................................................................................................................................... 5 Summary of Test Result .......................................................................................................................................... 6 1. General Information .................................................................................................................................. 7 1.1. EUT Description ....................................................................................................................................... 7 1.2. EUT Information ....................................................................................................................................... 8 1.3. Testing Applied Standards ........................................................................................................................ 8 1.4. Testing Location Information .................................................................................................................... 9 1.5. Ambient Conditions In The Laboratory ................................................................................................... 10 1.6. Measurement Uncertainty ...................................................................................................................... 10 1.7. List of Test Equipment ............................................................................................................................ 11 2. Test Configuration of EUT ...................................................................................................................... 12 2.1. Test Condition ......................................................................................................................................... 12 2.2. Test Frequency Mode ............................................................................................................................. 12 2.3. Duty Cycle .............................................................................................................................................. 13 2.4. Measurement Configuration ................................................................................................................... 14 2.5. Tested System Details ............................................................................................................................ 15 2.6. Configuration of Tested System ............................................................................................................. 15 3. AC Power Line Conducted Emission ..................................................................................................... 16 3.1. Test Setup ............................................................................................................................................... 16 3.2. Test Limit ................................................................................................................................................ 16 3.3. Test Procedure ....................................................................................................................................... 16 3.4. Test Result of AC Power Line Conducted Emission ............................................................................... 16 4. Occupied Bandwidth & DTS Bandwidth ................................................................................................. 17 4.1. Test Setup ............................................................................................................................................... 17 4.2. Test Limit ................................................................................................................................................ 17 4.3. Test Procedures ...................................................................................................................................... 17 4.4. Test Result of Occupied Bandwidth & DTS Bandwidth .......................................................................... 17 5. Maximum Peak Conducted Output Power ............................................................................................. 18 5.1. Test Setup ............................................................................................................................................... 18 5.2. Test Limit ................................................................................................................................................ 18 5.3. Test Procedures ...................................................................................................................................... 18 5.4. Test Result of Maximum Peak Conducted Output Power ...................................................................... 18 6. Maximum Power Spectral Density ........................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Genta Sato(General Manager)
[email protected]Fax: 81-44-844-3938

Technical Contact

Canon U.S.A., Inc.Julie La Spina

One Canon Park, · Melville, New York, 11747 · United States

Test Firm

DEKRA TESTING AND CERTIFICATION CO., LTD. LinKouMirenda Liao
[email protected]Fax: +886-2-2602-6881

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz130.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported Body SAR value is 0.54 W/kg.

Other Applications from Canon Inc.

AZD260

Digital Camera

Dec 17, 2025

Equipment Class

DTS - Digital Transmission System
Wireless Module - FCC ID AZD248 - Canon Inc.
AZD248

Wireless Module

Aug 11, 2024

Equipment Class

DTS - Digital Transmission System
AZD323

Wireless Module

Jul 22, 2024

Equipment Class

DTS - Digital Transmission System
AZD250

Wireless Microphone

Jun 09, 2024

Equipment Class

DTS - Digital Transmission System
Wireless LAN Module - FCC ID AZDFM3L998 - Canon Inc.
AZDFM3L998

Wireless LAN Module

Feb 12, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX