User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 110-March-00 User’s manual for band or channel selective Repeater MRx01B Power User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 210-March-00 Copyright MIKOM, Buchdorf 2000 All rights reserved. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 310-March-00 Table of Contents LIST OF FIGURES AND TABLES6 LIST OF UNIT SPECIFIC ABBREVIATIONS7 CONTENTS OF DELIVERY7 HEALTH AND SAFETY WARNING 8 PREAMBLE9 1INTRODUCTION11 1.1Intended purpose11 1.2About the MRx01B Power11 1.3Modular design11 1.4Applications12 2FUNCTIONAL DESCRIPTION13 2.1General13 2.2Conversion modules14 2.3Mother board14 2.4Control module SM 2009 ( Rev. 07 and higher )16 2.5Duplexer20 2.6Active combiner21 2.7Measuring aids21 2.8Feedforward amplifier22 2.9Power supply22 3FUNCTIONS AND FEATURES24 3.1Band and channel selectivity24 User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 410-March-00 3.2Gain setting24 3.3ALC25 3.4CFO25 3.5BITE and alarms25 3.5.1Handling of alarms27 3.5.2Status report28 3.5.3Severity levels28 4OPTIONAL EQUIPMENT29 4.1VSWR module29 4.2External alarms29 4.3Modem30 4.4External RF output31 4.5Battery backup module32 5INSTALLATION33 5.1Mechanical installation34 5.2Electrical installation36 5.2.1Grounding36 5.2.2Power connection37 5.2.3Connection of the antenna cables37 6SETTING TO WORK39 6.1Preparation39 6.2Setting of operational parameters39 6.2.1Manual settings by means of rotary switches40 6.2.2Setting of the attenuation40 6.2.3Settings via personal computer as terminal42 6.2.4Settings via modem44 7TROUBLE SHOOTING45 7.1Error indication45 7.2Alarm monitoring with the STATUS HIST command45 User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 510-March-00 7.3Power supply46 7.4General remarks46 8MAINTENANCE47 8.1General47 8.2Replacement of the fuses (mains)47 8.3Replacement of the power supply fuse48 8.4Replacement of the mains cable48 8.5Replacement of the RAM / RTC battery49 8.6Replacement of the duplexers50 8.7Replacement of conversion modules50 8.8Replacement of the control module SM 200953 8.9Replacement of power supplies54 8.10Replacement of active combiner modules55 8.11Replacement of feedforward amplifier55 9APPENDICES58 9.1Repeater specifications58 9.2Spare parts lists for MRx01B Power68 9.2.1Spare parts list for MR301B Power68 9.2.2Spare parts list for MR401B Power70 9.2.3Spare parts list for MR701B Power71 9.2.4Spare parts list for MR801B Power and MR801Bi Power73 9.3Installation drawing of the Repeater75 9.4Top view of the Repeater (left side , exemplary configuration)76 9.5Top view of the Repeater (right side, exemplary configuration)77 9.6One channel configuration – cabling and block diagram78 10INDEX80 User’s manual for Repeater MRx01B Power M0079A1A.docId.-No. 151775Page 610-March-00 LIST OF FIGURES AND TABLES table 1-1 List of international sales offices..............................................................................10 figure 2-1 Block diagram of MRx01B Power..........................................................................13 figure 2-2 Top view of a conversion module...........................................................................14 figure 2-3 Top view of a mother board....................................................................................15 figure 2-4 Configuration of the control module ( Rev.07 and higher )....................................18 figure 2-5 Configuration of the DIP-Switches.........................................................................19 figure 2-6 Top view of the duplexers.......................................................................................20 figure 2-7 Top view of the active combiner module................................................................21 figure 2-8 Top view of the feedforward amplifier...................................................................22 figure 2-9 Mounting position of power supplies......................................................................23 figure 2-10 ON / OFF position of external switch...................................................................23 figure 3-1 Position of rotary switches......................................................................................24 table 3-2 List of all available alarms........................................................................................26 figure 4-1 Clamps for external alarms......................................................................................29 figure 4-2 Modem kit...............................................................................................................31 figure 4-3 Position of external RF output.................................................................................31 figure 4-4 Mounting position of batteries................................................................................32 figure 5-1 System description..................................................................................................33 figure 5-2 Top view and clearance distance.............................................................................34 figure 5-3 Wall mounting brackets...........................................................................................35 figure 5-4 Grounding kit..........................................................................................................36 figure 5-5 Screw terminal.........................................................................................................37 figure 5-6 Connector panel layout............................................................................................38 table 6-1 LED i…
Text truncated - open the document above for the full version.
User’s manual for Repeater MRx01B Power Manual updatex01.docId.-No. 151775Page 15-November-00 User’s manual for band or channel selective Repeater MRx01B Power User’s manual for Repeater MRx01B Power Manual updatex01.docId.-No. 151775Page 95-November-00 HEALTH AND SAFETY WARNINGS Installer Warning: Any over the air radiated use of this product is intended to be used with either Roof Top (Building-mount) or Pole Mounted (Non- building-mount) Antennas. Antenna installation must conform within the following guidelines to meet FCC RF exposure limits, otherwise a environmental evaluation is required if: Broadband PCS (subpart E): Non-building-mounted antennas: height above ground level to lowest point of antenna < 10m Radio (Part 24) and total power of all channels > 2000 W ERP (3280 W EIRP). Building-mounted antennas: Total power of all channels > 2000 W ERP (3280 W EIRP). Cellular Radiotelephone Service (Part 22, subpart H): Non-building- mounted antennas: height above ground level to lowest point of antenna < 10m Radio (Part 22) and total power of all channels > 1000 W ERP (1640 W EIRP). Building-mounted antennas: Total power of all channels > 1000 W ERP (1640 W EIRP). Private Land Mobile Radio\Specialized Mobile Radio (Part 90): Non-building-mounted antennas: height above ground level to lowest point of antenna < 10m Radio (Part 90) and total power of all channels > 1000 W ERP (1640 W EIRP). Building-mounted antennas: Total power of all channels > 1000 W ERP (1640 W EIRP). For any clarification, please refer to FCC rules, 47 CFR ch. I, part 1.1307 User’s manual for Repeater MRx01B Power Manual updatex01.docId.-No. 151775Page 105-November-00 F Note: The electrical installation has to be performed in accordance with the safety regulations of the local authorities. Due to safety reasons the electrical installation must be performed by qualified personnel. The cover of this unit should not be opened while power is applied. Subsequent installation, commissioning and maintenance activities that require the unit to be powered with the cover open shall only be carried out by suitably qualified personnel. F Note: The grounding of the Unit has to be performed by all means. A grounding bolt is provided at the cabinet in order to connect the earth bonding cable. F Note: The Unit is heavy-weight. Make sure that a suitable mounting surface is used. Only adequate manpower is allowed to handle the system. F Note: ESD precautions have to be observed! Before maintenance work use the available grounding system to connect ESD protection measures. User’s manual for Repeater MRx01B Power Manual updatex01.docId.-No. 151775Page 125-November-00 1 INTRODUCTION 1.1 Intended purpose Cellular telephone systems transmit signals in two directions between base stations and mobile telephones within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, a repeater is used to extend transmission range. In the downlink path the repeater picks up the signal from a donor antenna of an existing cell, amplifies and re-transmits it into the desired dark spot. In the uplink direction the repeater receives signals from mobile stations present in its coverage area and re-transmits them to the corresponding base station. The over the air radiated use of this repeater is intended to be used with either Roof Top or Pole Mounted Antennas. To provide coverage in a indoor application one must mount the antennas on or outside the building structure that is occupied. This must be done in a matter that conforms to the FCC RF exposure ( See health and Saftey section of this manual). 1.2 About the MRx01B Power This repeater bi-directionally amplifies signals between multiple mobiles and a single base station in the frequency band. It is employed where poor topological conditions cause weak field strengths. It can provide highly selective amplification of band segments or channels in the frequency band. The MRx01B Power can be set-up locally or remotely. A PCMCIA slot for modem operation is an available option. The repeater has a large number of functions that can be monitored and changed by the operators via a terminal emulation program or the MIKOM OMC software platform. An easy to understand and simple to learn communication language is available to help the operator query status reports from the repeater or to change settings. User’s manual for Repeater MRx01B Power Manual updatex01.docId.-No. 151775Page 135-November-00 1.3 Modular design F Note:It is not possible to combine MRx01 units / modules with other MRx01 units / modules without verifying FCC Approval and RF Exposure Compliance ( See health and Saftey section of this manual). For any clarification, please refer to FCC rules, 47 CFR ch. I, part 1.1307 The MRx01B repeater’s modular design provides the flexibility in addressing present and future system needs. Each repeater is custom configured. The main unit includes equipment common to all systems ( cabinet, control module, power supply, mother board ). To this main unit hardware modules are added as needed. In addition to different duplexers, a wide range of conversion modules can be selected depending on the used network system. MRx01B Power modules operating in PCS1900, AMPS800, or LMR\IDEN800 bands are available.
LMR800 BAND OR CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks AN ALLEN TELECOM COMPANY MR801Bi POWER Industriering 10 ï 86675 Buchdorf ï Germany ï Phone: +49 (0) 90 99 6 90 ï Fax: +49 (0) 90 99 69 31 E-mail: [email protected] ï http://www.mikom.com MIKOMís MR801Bi POWER is available as a variable band selective or channel selective repeater for iDEN and Analog. This repeater bi-directionally amplifies signals between multiple mobiles and a single base station in the AMPS800 frequency band. It is employed where poor topological conditions cause weak field strengths. It can provide highly selective amplification of band segments or channels in the AMPS800 band. MR801Bi POWER modules can be combined with other repeater modules in order to create a multi-band repeater system. Modules operating in PCS1900, GSM1800, GSM900, or iDEN bands are available. When different modules are combined, a common antenna and control interface are available. The MR801Bi POWER can be set-up locally or remotely. A PCMCIA slot for modem operation is an available option. The repeater has a large number of functions that can be monitored and changed by the operators via a terminal emulation program or the MIKOM OMC software platform. An easy to understand and simple to learn communication language is available to help the operator query status reports from the repeater or to change settings. ïEfficient ultra high power amplifiers ïInterference cancellation equipment for antenna isolation improvement ïRemote control and operation & maintenance center ïBuilt in test equipment ïEasy and fast to install and upgrade ïRS232, PCMCIA or PSTN data interface ïCombinations of AMPS800, PCS1900, GSM900, GSM1800, TACS and ETACS are possible ïBand or channel selective ©1999 Allen Telecom Inc. 8/99 MK-1016 Rev. 2 LMR800 BAND OR CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks AN ALLEN TELECOM COMPANY MR801Bi POWER Industriering 10 ï 86675 Buchdorf ï Germany ï Phone: +49 (0) 90 99 6 90 ï Fax: +49 (0) 90 99 69 31 E-mail: [email protected] ï http://www.mikom.com ELECTRICAL SPECIFICATIONS FrequencyUplink 806-824 MHz; Downlink 851-869 MHz Gain90 dB Gain variation over frequency and temperature*±2.5 dB (±3.5 dB at extreme temperatures) Gain adjust range30 dB in 2 dB steps Gain adjust range tolerance±0.5 dB Return loss15 dB @ 25∞C ambient temperature Spurious/intermodulation-13 dBm max Power supply100-130 VAC / 40-60 Hz Option: 15-24 VDC or 36-72 VDC Option: 220-250 VAC / 40-60 Hz RF connector7/16 female; Option: N female Environmental and safetySee separate leaflet *Normal temperature range +5∞ to +40∞C; Extreme temperature range -33∞ to +50∞C BAND AND CHANNEL SPECIFICATIONS VariableChannel BandwidthSelective Bandwidth 0.1*-15.0 MHz25 kHz Slope 3 dB to 30 dB2 MHz- 30 dB bandwidth-f c ±60 kHz 50 dB bandwidth-f c ±120 kHz Delay6 μs20 μs typ. Delay variation (typical)±150 ns±500 ns typ. Far off selectivity40 dB50 dB NF at Gmax8 dB6 dB NF at Gmax -30 dB13 dB12 dB OICP-3 at Gmax48 dBm48 dBm OICP-3 at Gmax -10 dB48 dBm48 dBm OICP-3 at Gmax -20 dB47 dBm47 dBm OICP-3 at Gmax -30 dB45 dBm45 dBm Output noise in band at Gmax-81 dBm/Hz- Output noise out of band at Gmax-101 dBm/Hz- Pwr consumption stdby/max pwr: 1 module155/220 W typ.150/210 W typ. 4 modules200/265 W typ.175/240 W typ. * 1.5 dB gain degradation at 100 kHz LMR800 BAND OR CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks AN ALLEN TELECOM COMPANY MR801Bi POWER Industriering 10 ï 86675 Buchdorf ï Germany ï Phone: +49 (0) 90 99 6 90 ï Fax: +49 (0) 90 99 69 31 E-mail: [email protected] ï http://www.mikom.com AVAILABLE POWER PER TECHNOLOGY iDENAnalog Pout at 1 channel37.0 dBm40.0 dBm Pout/channel at 2 channels31.0 dBm37.0 dBm Pout/channel at 4 channels28.0 dBm33.0 dBm Pout/channel at 8 channels25.0 dBm29.0 dBm ALC threshold Adjustable MECHANICAL SPECIFICATIONS Height, width, depth21.1 x 18.2 x 7.9 inches 535 x 462.5 x 200 mm Volume>46 liters Weight (approx.)103 lbs (47 kg) All data is subject to change without notice LMR800 BAND OR CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks AN ALLEN TELECOM COMPANY MR801Bi POWER Industriering 10 ï 86675 Buchdorf ï Germany ï Phone: +49 (0) 90 99 6 90 ï Fax: +49 (0) 90 99 69 31 E-mail: [email protected] ï http://www.mikom.com DESIGN PRINCIPLE OPTIONS VSWR moduleMeasurement of VSWR of downlink output antenna port. Alarm threshold at 10 dB return loss. Battery backup, UPSBackup time 20 min to 2 hours. RF power boosterDownlink power capability of 50 watts or 100 watts peak. Low noise uplink preamplifier. MountingPole mounting kit and free standing option. This preliminary data is for information purposes only and should not be construed as an offer for sale of the equipment described pending F.C.C. type acceptance.
MR801iB LMR800 CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks 30500 Bruce Industrial Parkway ï Cleveland, Ohio 44139-3996 Phone 440-519-8600 ï FAX 440-519-8607 ï www.allentele.com AN ALLEN TELECOM COMPANY ©1999 Allen Telecom Inc. 7/99 MK-1006 Rev. 1 MIKOMís MR801iB is a availble as a channel selective repeater for iDEN and analog. This repeater bi-directionally amplifies signals between multiple mobiles and a single base station in the LMR800 frequency band. It is employed where poor topological conditions cause weak field strengths. It can provide highly selective amplification of channels in the LMR800 band. MR801iB modules can be combined with other repeater modules in order to create a multi-band repeater system. Modules operating in AMPS800, PCS1900, GSM1800, or GSM900 bands are available. When different modules are combined a common antenna and control interface are available. The MR801iB can be set-up locally or remotely. A PCMCIA slot for modem operation is an available option. The repeater has a large number of functions that can be monitored and changed by the operators via a terminal emulation program or the MIKOM OMC software platform. An easy to understand and simple to learn communication language is available to help the operator query status reports from the repeater or to change settings. ïEfficient ultra high power amplifiers ïInterference cancellation equipment for antenna isolation improvement ïRemote control and operation and maintenance center ïExtremely small size and weight, less than 30 lbs (14 kg) ïBuilt in test equipment ïEasy and fast to install and upgrade ïRS232, PCMCIA or PSTN data interface ïCombinations of PCS1900, GSM1800, GSM900, TACS, ETACS, AMPS800, and iDEN are possible MR801iB LMR800 CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks 30500 Bruce Industrial Parkway ï Cleveland, Ohio 44139-3996 Phone 440-519-8600 ï FAX 440-519-8607 ï www.allentele.com AN ALLEN TELECOM COMPANY ELECTRICAL SPECIFICATIONS FrequencyUplink 806-821 MHz; Downlink 851-866 MHz Gain85 dB Gain variation over frequency and temperature*±2.5 dB (±3.5 dB at extreme temperatures) Gain adjust range30 dB in 2 dB steps Gain adjust range tolerance±0.5 dB Return loss15 dB @ 25∞C ambient temperature Spurious/intermodulation-13 dBm max for non European systems -36/-30 dBm for European Systems Power supply100-130 VAC / 40-60 Hz Option: 15-24 VDC or 36-72 VDC Option: 220-250 VAC / 40-60 Hz RF connectors7/16 female; Option: N female Environmental and safetySee separate leaflet *Normal temperature range +5∞ to +40∞C; Extreme temperature range -33∞ to +50∞C BAND AND CHANNEL SPECIFICATIONS 3 dB bandwidth25 kHz 30 dB bandwidthf c ±60 kHz 50 dB bandwidthf c ±120 kHz Delay20 μs Delay variation (typical)±500 ns Far off selectivity55 dB NF at Gmax5 dB NF at Gmax -30 dB8 dB OICP-3 at Gmax48 dBm OICP-3 at Gmax -10 dB48 dBm OICP-3 at Gmax -20 dB48 dBm OICP-3 at Gmax -30 dB47.5 dBm Pwr consumption stdby/max pwr: 1 module110/110 W typ. 4 modules140/140 W typ. MR801iB LMR800 CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks 30500 Bruce Industrial Parkway ï Cleveland, Ohio 44139-3996 Phone 440-519-8600 ï FAX 440-519-8607 ï www.allentele.com AN ALLEN TELECOM COMPANY AVAILABLE POWER Pout at 1 channel36.0 dBm Pout/channel at 2 channels31.0 dBm Pout/channel at 4 channels26.5 dBm Pout/channel at 8 channels23.0 dBm ALC thresholdadjustable MECHANICAL SPECIFICATIONS The MR801iB is available in two different cabinets (see table below). The standard cabinet is able to hold a 2 channel system and is upgradeable to an 8 channel system through an external cablebridge between the 2 channel cabinets. A combination of AMPS800 with other bands such as PCS1900 or GSM900 is possible. An 8 channel cabinet is also available. 2 ch cabinet (standard)8 ch cabinet (large) Channel selective ̧ ̧ Band select ̧ ̧ Height, width, depth16.7 x 10.0 x 4.3 inches21.1 x 18.2 x 7.9 inches 425 x 255 x 110 mm535 x 462.5 x 200 mm Volume<12 liters45 liters Weight (approx.)30 lbs (14 kg) per unit103 lbs (47 kg) All data is subject to change without notice. MR801iB LMR800 CHANNEL SELECTIVE REPEATER for iDEN and Analog Networks 30500 Bruce Industrial Parkway ï Cleveland, Ohio 44139-3996 Phone 440-519-8600 ï FAX 440-519-8607 ï www.allentele.com AN ALLEN TELECOM COMPANY DESIGN PRINCIPLE OPTIONS VSWR moduleMeasurement of VSWR of downlink output antenna port. Alarm threshold at 10 dB return loss. Interference Cancellation EquipmentElectronic improvement of antenna isolation. Available for iDEN. (I.C.E.)channel option. Battery backup, UPSBackup time 20 min to 2 hours. RF power boosterDownlink power capability of 50 watts composite. Low noise uplink preamplifier. MountingPole mounting kit and free standing option. This preliminary data is for information purposes only and should not be construed as an offer for sale of the equipment described pending F.C.C. type acceptance.
MR801Bi The final amplifier used in the MR801Bi is a class A linear amplifier rated at a P1dB of 8 watts. The rated RF Power output using this amplifier is +37 dBm. Separate amplifiers, having the same electrical performance other than frequency of operation, are used for the uplink and downlink paths. MR801Bi Power The final amplifier used in the MR801Bi Power is a feed-forward linear amplifier rated for 30 watts peak power. The rated RF Power output using this amplifier is +43 dBm. Separate amplifiers, having the same electrical performance other than frequency of operation, are used for the uplink and downlink paths.
Figure 1 - External View 1 Figure 2 - External View 2
Figure 1 - Left Side of EUT cabinet Figure 2 - Right Side of EUT Cabinet Figure 3 - Conversion Module Figure 4 - High Power Amplifier Module Figure 5 - Channelized Module with iDEN filter Figure 6 - Active Combiner Module Figure 7 - Low Power Amplifier Module
Technical description For a technical description refer to MR801Bi Users Manual IDNr: 151793 pages 12-21 and the MR801Bi Power Users Manual IDNr: 151794 pages 12-21.
-----------------À Strukturstückliste 148616 MR801Bi (G) /00 00001 0 1 2 3 4 5 6 7 8Ë-------------------------------------------------------------- 148616 *MR801Bi (G) /00 1,000 112425 Adapter 10 0,000 143896 *Montagematerial 20 1,000 150152 *Basic Module /00 30 0,000 150153 *Extension Module /00 40 0,000 150150 *Bas.Mod.Var.BW 15,0MHz/01 50 0,000 150151 *Ext.Mod.Var.BW 15,0MHz/01 60 0,000 138305 Power Supply, GER plug/10 70 0,000 142832 Power Supply, UK plug /10 80 0,000 144306 Power Supply, no plug /00 90 0,000 148812 Power Supply, no plug /00 100 0,000 141230 Power Supply, USA plug/10 110 0,000 145504 Power Supply, no plug /00 120 0,000 144946 Power Supply, no plug /02 130 0,000 145524 Power Supply, no plug /01 140 0,000 148336 *Duplexer DL Input act./00 150 1,000 148335 *Duplexer UL Input act./00 160 1,000 148698 *Final Amplifier /00 170 1,000 148959 *Active Combiner DL/02 180 1,000 148960 *Active Combiner UL/02 190 1,000 147127 SW REP1009 V1.11 200 0,000 143051 *Control Unit SM2009 /07 210 1,000 143052 *Battery Backup Module /02 220 0,000 143750 *Battery Backup Module /02 230 0,000 143055 SW MOB100 V1.10 240 1,000 143407 *Main Board /00 250 1,000 143563 *Main Board /00 260 1,000 146200 *Sparepart kit 270 1,000 33167 Termination Resistor 280 2,000 146179 *Wall mounting kit 290 1,000 142529 Pole mounting kit 300 0,000 146190 *LED-Kit 310 0,000 150615 *RF Gland / SMA to N/00 320 0,000 147710 *4 Ext. Alarms /00 330 0,000 151090 *Modification Kit /00 340 0,000 149918 *Modification Kit /00 350 0,000 151092 *Modification Kit /00 360 0,000 149920 *Modification Kit /00 370 0,000 151727 *Modification Kit TDMA /00 380 0,000 151729 *Modification Kit TDMA /00 390 0,000 150404 Mobile kit AMPS800 /00 400 0,000 150407 Mobile kit AMPS800 /00 410 0,000 151013 Faltkarton 2.7 8-Kanal 420 1,000 151014 Ethafoam 220 8-Kanal 430 1,000 149916 Kabelbaum 440 1,000 148964 Manual REP1009V1.xx 450 0,000 151793 Manual MR801Bi 460 0,000 Gesamt: 17,000 0,00 -----------------À Strukturstückliste 150152 Basic Module /00 00001 0 1 2 3 4 5 6 7 8Ë-------------------------------------------------------------- 150152 *Basic Module /00 1,000 150830 Assembly drawing 10 0,000 149094 Assembly drawing 20 0,000 148557 *Montagematerial 30 1,000 151757 *Platine best. 1358.1 40 2,000 144406 Platine roh 1238.1 50 2,000 149089 *Bandpassfilterbox /00 60 1,000 149849 *Detektor GSM 900/AMPS /00 70 2,000 90332 Kondensator 6,8pF 80 3,000 94037 Kondensator SMD 100,0pF 90 1,000 113332 Kondensator SMD 0,5pF 100 1,000 117549 Spule SMD 22,0nH, ±5% 110 1,000 131656 Kondensator SMD 1,2pF 120 1,000 131680 Kondensator SMD 10,0pF 130 2,000 131706 Widerstand SMD 0,0Ohm 140 1,000 131763 Widerstand SMD 220,0Ohm 150 1,000 131797 Widerstand SMD 1,0kOhm 160 1,000 140380 Widerstand SMD 560,0Ohm 170 1,000 143290 Stiftleiste 12-p.2-reihig 180 1,000 143505 Spule SMD 6,8nH, ±5% 190 1,000 144736 Kondensator SMD 33,0pF 200 1,000 144786 Widerstand SMD 5,6kOhm 210 1,000 146089 Kondensator SMD 2,7pF 220 2,000 148029 Kondensator SMD 8,2pF 230 1,000 148414 Spule SMD 18,0nH, ±5% 240 1,000 148501 Kondensator SMD 1,8pF 250 1,000 148521 Stiftleiste, 12-polig 260 1,000 148752 Isolator 0,806-0,825GHz 270 2,000 148753 Isolator 0,845-0,875GHz 280 2,000 148894 Widerstand Poti SMD 290 1,000 151737 *Platine best. 1415.1 300 3,000 151738 *Platine best. 1415.1 310 3,000 116004 Zylinderkopfschraube 320 6,000 14332 Unterlegscheibe für M2,0 330 12,000 147826 Label 340 0,000 147817 Label 350 0,000 60772 Etiketten 360 0,000 Gesamt: 60,000 0,00 -----------------À Strukturstückliste 150153 Extension Module /00 00001 0 1 2 3 4 5 6 7 8Ë-------------------------------------------------------------- 150153 *Extension Module /00 1,000 150863 Assembly drawing 10 0,000 149094 Assembly drawing 20 0,000 148889 *Montagematerial 30 1,000 151756 *Platine best. 1365.1 40 2,000 150624 Platine roh 1390.1 50 2,000 143367 *Platine best. 1178.3 60 2,000 149849 *Detektor GSM 900/AMPS /00 70 2,000 149089 *Bandpassfilterbox /00 80 1,000 90332 Kondensator 6,8pF 90 3,000 94037 Kondensator SMD 100,0pF 100 1,000 113332 Kondensator SMD 0,5pF 110 1,000 117549 Spule SMD 22,0nH, ±5% 120 1,000 131656 Kondensator SMD 1,2pF 130 1,000 131680 Kondensator SMD 10,0pF 140 2,000 131706 Widerstand SMD 0,0Ohm 150 1,000 131763 Widerstand SMD 220,0Ohm 160 1,000 131797 Widerstand SMD 1,0kOhm 170 1,000 140380 Widerstand SMD 560,0Ohm 180 1,000 143290 Stiftleiste 12-p.2-reihig 190 1,000 143505 Spule SMD 6,8nH, ±5% 200 1,000 144736 Kondensator SMD 33,0pF 210 1,000 144786 Widerstand SMD 5,6kOhm 220 1,000 146089 Kondensator SMD 2,7pF 230 2,000 148029 Kondensator SMD 8,2pF 240 1,000 148414 Spule SMD 18,0nH, ±5% 250 1,000 148501 Kondensator SMD 1,8pF 260 1,000 148521 Stiftleiste, 12-polig 270 1,000 148752 Isolator 0,806-0,825GHz 280 1,000 148753 Isolator 0,845-0,875GHz 290 1,000 148894 Widerstand Poti SMD 300 1,000 151737 *Platine best. 1415.1 310 3,000 151738 *Platine best. 1415.1 320 3,000 116004 Zylinderkopfschraube 330 4,000 14332 Unterlegscheibe für M2,0 340 8,000 147815 Label 350 0,000 60772 Etiketten 360 0,000 Gesamt: 54,000 0,00 -----------------À Strukturstückliste 150150 Bas.Mod.Var.BW 15,0MHz/01 00001 0 1 2 3 4 5 6 7 8Ë-------------------------------------------------------------- 150150 *Bas.Mod.Var.BW 15,0MHz/01 1,000 148020 Assembly drawing 10 0,000 148009 *Montagematerial 20 1,000 151066 *Platine best. 1347.2 30 2,000 12344 Kondensator SMD 1,5pF 40 1,000 12351 Kondensator SMD 1,0pF 50 2,000 12419 Kondensator SMD 5,6pF 60 2,000 12427 Kondensator SMD 6,8pF 70 2,000 90332 Kondensator 6,8pF 80 3,000 131631 Kondensator SMD 0,5pF 90 4,000 140864 Widerstand SMD 62,0Ohm 100 1,000 143387 Spule SMD 10 nH, ±5% AVX 110 2,000 144115 Kondensator SMD 10,0nF 120 1,000 144117 Kondensator SMD 4,7pF 130 1,000 144119 Kondensator SMD 82pF 140 2,000 146089 Kondensator SMD 2,7pF 150 2,000 146152 Kondensator SMD 5,6pF 160 1,000 148029 Kondensator SMD 8,2pF 170 2,000 148031 Kondensator SMD 39pF 180 2,000 148035 Kondensator SMD 3,9pF 190 2,000 1…
Text truncated - open the document above for the full version.
-----------------À Strukturstückliste 151270 MR801Bi Power (G) /00 00001 0 1 2 3 4 5 6 7 8Ë-------------------------------------------------------------- 151270 *MR801Bi Power (G) /00 1,000 149952 Assembly drawing 10 0,000 150563 Assembly drawing 20 0,000 150521 *Montagematerial 30 1,000 148335 *Duplexer UL Input act./00 40 1,000 148336 *Duplexer DL Input act./00 50 1,000 148960 *Active Combiner UL/02 60 1,000 148959 *Active Combiner DL/02 70 1,000 150150 *Bas.Mod.Var.BW 15,0MHz/01 80 0,000 150151 *Ext.Mod.Var.BW 15,0MHz/01 90 0,000 150152 *Basic Module /00 100 0,000 150153 *Extension Module /00 110 0,000 151232 Feedforward Amplifier /01 120 1,000 151233 Feedforward Amplifier /01 130 1,000 138305 Power Supply, GER plug/10 140 0,000 142832 Power Supply, UK plug /10 150 0,000 148812 Power Supply, no plug /00 160 0,000 144306 Power Supply, no plug /00 170 0,000 141230 Power Supply, USA plug/10 180 0,000 145524 Power Supply, no plug /01 190 0,000 144946 Power Supply, no plug /02 200 0,000 145504 Power Supply, no plug /00 210 0,000 147710 *4 Ext. Alarms /00 220 0,000 143052 *Battery Backup Module /02 230 0,000 143750 *Battery Backup Module /02 240 0,000 150615 *RF Gland / SMA to N/00 250 0,000 112425 Adapter 260 0,000 143055 SW MOB100 V1.10 270 1,000 147127 SW REP1009 V1.11 280 0,000 149917 *Modification Kit /00 290 0,000 149918 *Modification Kit /00 300 0,000 151135 *Modification Kit TDMA /00 310 0,000 150529 *Modification Kit /00 320 0,000 149920 *Modification Kit /00 330 0,000 151671 *Modification Kit TDMA /00 340 0,000 149778 *Main Board 26V version/00 350 1,000 149777 *Main Board 26V version/00 360 1,000 143051 *Control Unit SM2009 /07 370 1,000 146179 *Wall mounting kit 380 1,000 146200 *Sparepart kit 390 1,000 33167 Termination Resistor 400 2,000 149648 *Konf. Kabel DC 410 2,000 150753 *Konf.Kabel DC ac…
Text truncated - open the document above for the full version.
802 N. Kealy · Lewisville, Texas · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 9 | 851.0125 MHz - 868.9875 MHz | 20 W | D7W | Amp |

ION-E
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
ION-M17P/26 EU
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
ION-B TFAH-US7/17
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
ION-B TFAH-US4B
Equipment Class
PCB - PCS Licensed Transmitter
ION-B TFBM17 FIBER OPTIC DISTRIBUTION REMOTE UNIT
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter