DRAFT 1 TB9300 Installation and Operation ManualInstallation65 © Tait Limited November 2014 5Installation This chapter provides information on the site requirements for your TB9300 equipment and also describes how to install the base station in a standard 19 inch rack or cabinet. If this is your first time installing a TB9300 base station, we recommend that you read the entire chapter before beginning the actual installation. DRAFT 1 66InstallationTB9300 Installation and Operation Manual © Tait Limited November 2014 5.1Before You Begin 5.1.1Equipment Security The security of your base station equipment is a high priority. If the site is not fully secure, the base station should at least be locked in a secure cabinet to prevent unauthorized access. 5.1.2Grounding and Lightning Protection Electrical GroundThe base station modules are grounded by physical contact between the module case and the subrack. To ensure a good ground connection you must tighten each module retaining clamp securely (refer to “Final Reassembly” on page 110 for the correct torque). A threaded grounding connector is provided on the rear of the subrack for connection to the site ground point (refer to “Connecting Up the Base Station” on page 86 for more details). Lightning GroundIt is extremely important for the security of the site and its equipment that you take adequate precautions against lightning strike. Because it is outside the scope of this manual to provide comprehensive information on this subject, we recommend that you conform to your country’s standards organization or regulatory body. 5.1.3Equipment Ventilation Always ensure there is adequate ventilation around the base station. NoticeDo not operate it in a sealed cabinet. You must keep the ambient temperature within the specified range, and we strongly rec- ommended that you ensure that the cooling airflow is not restricted. NoticeThe cooling fans are mounted on the front panel and will only operate when the panel is fitted correctly to the front of the subrack. To ensure adequate airflow through the base station, do not operate it for more than a few minutes with the front panel removed (e.g. for servicing purposes). 5.1.4Ambient Temperature Sensor The ambient temperature reading for the base station is provided by the temperature sensor located on the front panel circuit board. DRAFT 1 TB9300 Installation and Operation ManualInstallation67 © Tait Limited November 2014 5.1.5Cabinet and Rack Ventilation The cooling airflow for the base station enters through the front panel and exits at the rear of the subrack. For optimum thermal performance, the heated air that has passed through a base station must not be allowed to re- enter the air intakes on the front panel. Any space at the front of the cabinet not occupied by equipment should be covered by a blanking panel. Refer toFigure 5.1 on page 68. To allow enough cooling airflow through a cabinet-mounted base station, we recommend the following: ■an area of at least 23 in 2 (150 cm 2 ) of unrestricted ventilation slots or holes in front of the air intakes for the fans for each subrack; for example, thirty 0.25 x 3.3 in (6 x 85 mm) slots will allow the recommended airflow ■a vent in the top of the cabinet with an area of approximately 23 in 2 (150 cm 2 ) per subrack, or a similar area of ventilation per subrack at the rear of the cabinet behind each subrack ■a 2 U gap at the top of the cabinet. NoticeThe ventilation opening must be unrestricted. If the slots or holes are covered with a filter, mesh or grille, the open area must be increased to allow the same airflow as an unrestricted opening. The maximum ambient temperature entering the cabinet must not exceed + 140°F (+ 60°C). If you are installing multiple subracks in a cabinet, ensure that there will be enough cooling airflow through the cabinet after the equipment has been installed. For example, the recommended maximum number of subracks in a 38 U cabinet is five, as shown in Figure 5.1 on page 68. If the base station is installed in a rack or cabinet with other equipment with different ventilation requirements, we recommend that the base station be positioned below this equipment. Auxiliary Extractor Fans The base station does not require auxiliary extractor fans mounted in the top of the cabinet. If your cabinet is already fitted with fans, the following procedures apply: ■if there are six or more 4.75 in (12 cm) fans, each capable of extracting 94.2 ft 3 per minute (160 m 3 per hour), they must run continuously ■if there are fewer than six fans, you must remove them and ensure the vent in the top of the cabinet has an area of approximately 23 in 2 (150 cm 2 ) per subrack. If you have any other configuration, the performance of your system will depend on how closely you comply with the base station airflow requirements described above. DRAFT 1 68InstallationTB9300 Installation and Operation Manual © Tait Limited November 2014 Figure 5.1Typical cabinet ventilation requirements b ventilation slots d airflow entry c blanking panels e airflow exit path 8in (20 cm) 2U ≥7in (≥17.5cm) side viewfront view top view c c d e b DRAFT 1 TB9300 Installation and Operation ManualInstallation69 © Tait Limited November 2014 5.2Unpacking and Moving the Subrack The subrack is packed in a strong corrugated cardboard carton with top and bottom foam cushions. To prevent personal injury and damage to the equipment, we recommend that two people unpack and move the subrack. To remove the subrack from the carton, follow the procedure illustrated in Figure 5.2. CautionA subrack complete with modules can weigh up to 62 lb (28 kg), or up to 66 lb (30 kg) complete with packaging. We recommend that you have another person help you unpack and move the equipment. The TBAA03-16 carrying handles will make it easier to move the equipment once it has been unpacked. If necessary, remove the modules from the subrack before moving it (refer to “Replacing Modules” on page 99). In all cases …
Text truncated - open the document above for the full version.
Tait Limited Phone: +64 3 357 0283 PO Box 1645, 558 Wairakei Road Fax: +64 3 359 4632 Burnside, Christchurch 8053 www.taitradio.com New Zealand 29 th October 2014 Request for Confidentiality FCC ID: CASTBCL0E In accordance with 47 C.F.R. Section 0.457 and 0.459, Tait Limited, hereby requests confidentiality for Schematics, Parts List, Tune-up Procedure, and Operational Description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. David Jackson Test Laboratory Services Manager Tait Limited
Justifi FCC ID: To meet t Frequenc This Bas e 1. T 2. C tr Program m In additi o 22 9 0 This dev i table ben The Gra n Table 1 – Freq. Ra 896-901 901-902 902-928 928-929 929-930 930-931 931-932 932-935 935-940 NF=Non Fed Des Fox Complia n Tait Limi Christchu 29 th Octo cation Le CASTBCL0 the requirem cy Range Lis e Station Tra The design ca Complies wit ransmit frequ ming this equ on to the foll 0 ice may be u neath. nt Note ‘EF’ – Frequency ange (MHz) deral, F=Federal nce Cordinat ited urch ober 2014 etter – Ex 0E ments of Fede stings for Cer ansmitter has apability to o th 47CFR Pa uencies using uipment is th lowing rule p utilised in sys should be ap Range and R Part 22 P NF NF F/NF tor xtended eral Commun rtification Gr s: operate in the art 90.203(e) g the normal he responsibi parts applied stems operate ppended to th Rule Parts - ( Part 90 NF NF NF NF NF Frequenc nications Com rants, Tait L e frequency b in that the e lly accessible ility of Tait L for: ed by Federa he Grant of A (47CFR Part cy Range mmission (F imited subm band 850-94 equipment op e external co Limited appr al and Public Authorisation 2.106) e F.C.C.) public mits the follow 41 MHz. perator canno ontrols. roved Service c Safety agen n, indicating Pag cation, KDB wing attestati ot directly pr e Agents ncies, as indi g this operatio ge 1 of 1 B634817 - ion. rogram cated in the on is required d.
Tait Limited Phone: +64 3 358 0403 PO Box 1645, 558 Wairakei Road Fax: +64 3 359 4632 Burnside, Christchurch 8053 www.taitradio.com New Zealand 29 th October 2014 Daniel E Crowder Elite Electronic Engineering Inc. 1516 Centre Circle, Downers Grove Illinois 60515 United States of America Dear Dan, Subject: Part 90.203 (j) (5) Certification Statement – FCC ID: CASTBCL0E Tait Limited certifies that it’s digital base station transceiver FCC ID: CASTBCL0E, meets a spectrum efficiency standard of one voice channel per 6.25 kHz of channel bandwidth. Additionally, Tait Limited certifies the equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth. Yours sincerely, David Jackson Test Laboratory Services Manager
Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 1 of 10 Tait Limited External Photographs Exhibit (October 2014) Product: TB9300 Type code: TBCL0E FCC ID: CASTBCL0E IC: 737A-TBCL0E Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 2 of 10 Photograph 01: 100W System – Product view Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 3 of 10 Photograph 02: 100W System – Front panel Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 4 of 10 Photograph 03: 100W System – Rear view Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 5 of 10 Photograph 04: 100W System – Internal view Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 6 of 10 Photograph 05: 100W PA module – Product view Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 7 of 10 Photograph 06: 100W PA module – Front panel Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 8 of 10 Photograph 07: 100W PA module – Rear panel Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 9 of 10 Photograph 08: Reciter module (927-941MHz) – Front panel Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 10 of 10 Photograph 09: Reciter module (927-941MHz) – Rear panel
Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 1 of 3 Tait Limited Compliance Label Photograph Exhibit (October 2014) Product: TB9300 Type code: TBCL0E FCC ID: CASTBCL0E IC: 737A-TBCL0E Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 2 of 3 Photograph 01: 100W System (927 Æ 941MHz) – Product ID label Photograph 02: Reciter module (927 Æ 941MHz) – Compliance label Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 3 of 3 Photograph 03: 100W PA module (850 Æ 941MHz) – Compliance label
Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 1 of 10 Tait Limited Internal Photographs Exhibit (November 2014) Product: TB9300 Type code: TBCL0E FCC ID: CASTBCL0E IC: 737A-TBCL0E Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 2 of 10 Photograph 01: 100W PA modules – Internal view Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 3 of 10 Photograph 02: 100W PA modules – Top. Shields Removed Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 4 of 10 Photograph 03: 100W PA modules - Bottom Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 5 of 10 Photograph 04: Rx PCB - Top Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 6 of 10 Photograph 05: Rx PCB – Top. Shields Removed Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 7 of 10 Photograph 06: Control PCB - Top Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 8 of 10 Photograph 07: Control PCB – Bottom Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 9 of 10 Photograph 08: TXF PCB – Top Tait Limited 535 Wairakei Road, Christchurch 8053 PO Box 1645 CHCH New Zealand +64 3 358 3399, www.taitradio.com Page 10 of 10 Photograph 09: TXF PCB – Top. Shields Removed Photograph 10: TXF PCB – Bottom.
Page 1 of 5 RF Exposure Technical Brief Supplementary to Teltest report 3605 Equipment: TBCL0E Basestation Transceiver IC identification 737A-TBCL0E Rated transmit power: 100W Frequency range: 929 940 MHz Test standard: RSS102 issue 4 Reference Standard: IEEE C95.3 -2002 Contents RSS102 Annex A - RF Technical Brief Cover Sheet .......................................................... 2 RSS102 Annex B - Declaration of RF Exposure Compliance ............................................ 3 Safe Distance calculations – Uncontrolled environment .................................................... 4 Minimum distance requirement stated in the user manual ................................................. 5 References: ....................................................................................................................... 5 Page 2 of 5 RSS102 Annex A - RF Technical Brief Cover Sheet All Fields must be completed with the requested information or the following codes: N/A for Not Applicable, N/P for Not Performed or N/V for Not Available. Where applicable, check appropriate box. 1. COMPANY NUMBER: 737A 2. MODEL NUMBER: TBCL0E 3. MANUFACTURER: Tait Communications 4. TYPE OF EVALUATION: (d) RF Exposure Evaluation.) Note: The worst-case scenario (i.e. highest measured value obtained) shall be reported. (a) SAR Evaluation: Device Used in the Vicinity of the Human Head ● Multiple transmitters: Yes □ No □ ● Evaluated against exposure limits: General Public Use □ Controlled Use □ ● Duty cycle used in evaluation: ____N/A______% ● Standard used for evaluation: _______ N/A __________________ ● SAR value: ___ N/A ___W/kg Measured □ Computed □ Calculated □ (b) SAR Evaluation: Body-Worn Device and Body-Supported Device ● Multiple transmitters: Yes □ No □ ● Evaluated against exposure limits: General Public Use □ Controlled Use □ ● Duty cycle used in evaluation: ___ N/A ___% ● Standard used for evaluation: ____ N/A _____________ ● SAR value: __ N/A ____W/kg Measured □ Computed □ Calculated □ (c) SAR Evaluation: Limb-Worn Device ● Multiple transmitters: Yes □ No □ ● Evaluated against exposure limits: General Public Use □ Controlled Use □ ● Duty cycle used in evaluation: __ N/A ____% ● Standard used for evaluation: ____ N/A __________________ ● SAR value: __ N/A _____W/kg Measured □ Computed □ Calculated □ (d) RF Exposure Evaluation ● Evaluated against exposure limits: General Public Use Controlled Use ● Duty cycle used in evaluation: 100 % ● Standard used for evaluation: IEEE C95.3 -2002 ● Measurement distance: 3.6 m ● RF field strength value: 3.9 V/m □ A/m □ W/m2 Measured □ Computed □ Calculated Page 3 of 5 RSS102 Annex B - Declaration of RF Exposure Compliance ATTESTATION: I attest that the information provided in Annex A is correct; that the Technical Brief was prepared and the information contained therein is correct; that the device evaluation was performed or supervised by me; that applicable measurement methods and evaluation methodologies have been followed; and that the device meets the SAR and/or RF field strength limits of RSS-102. Signature: Date: 19 November 2014 NAME (Please print or type): Mike James TITLE (Please print or type): Laboratory Technical Manager COMPANY (Please print or type): Teltest Laboratories Tait Communications Page 4 of 5 Safe Distance calculations – Uncontrolled environment Transmitter power : 100W Antenna Type: Quad dipole array. Vertically polarised Antenna Gain: 11.1dBi (linear gain of 12.9) Antenna Length: 1.1m Calculation frequency: 929MHz RF Field Strength limit for uncontrolled environments (RSS102 table 4.2) 300MHz to 1500MHz Limit = f/150 Wm 2 = 929/150 =6.19 W/m 2 Near field Calculation Equation 39 of IEEE C93.3-2002 = (2 ℎ) Rearranged to find d = (2 ℎ) For 100W = 100 2 × 6.19 × 1.1 = 2.27 Fresnel region and far field calculation Equation 37 of IEEE C93.3-2002 = 4 Rearranged to find d = 4 For 100W = 100 × 12.9 4 × 6.19 = 4.07 Page 5 of 5 Far Field boundary calculation The near field equation may be applied for several metres from the antenna, but may over predict the power density at longer distances. To determine which result should be used the crossover point where the predicted field strengths are the same is calculated. = ( 2 ℎ ) = 4 Rearranged to find d = ℎ 2 = 12.9 × 1.1 2 = 12.9 × 1.1 2 = 7.29 For a 1.2m antenna at 928MHz, the crossover point is 7.29m. Therefore the near-field calculation is appropriate and the minimum safe distance for the general public is 2.27m. Minimum distance requirement stated in the user manual For convenience the derived figure of 2.27m is rounded up to 3.6m giving the following for 100W = (2 ℎ) = 100 9 2 × 3.6 × 1.1 = 3.9 / Where: S=power density in W/m 2 P= net power output to the antenna (W) d = radius of a cylinder around the antenna (m) h = aperture height of antenna (m) G = linear gain of antenna relative to an isotropic radiator (11.1dBi = 12.9 linear terms) F = frequency (MHz) References: 1. RSS102 issue 4 March 2010 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) 2. IEEE Std C95.3-2002 IEEE Recommended Practice for Measurements and Computations of Radio Frequency End
TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 1 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 LABORATORY TEST REPORT RADIO PERFORMANCE MEASUREMENTS for the TBCL0E Base Station Transceiver Tested in accordance with: FCC 47 CFR Parts 22 and 90 RSS-119 Issue 11 RSS-Gen Issue 3 Report Revision: 1 Issue Date: 10-November-2014 PREPARED BY: Garry Pringle _______________ Test Technician CHECKED & APPROVED BY: M. C. James _______________ Laboratory Technical Manager OATS FCC LISTING REGISTRATION: 837095 OATS IC LISTING REGISTRATION: SITE# 737A-1 All tests reported herein have been performed in accordance with the laboratory's scope of accreditation. This document must not be reproduced except in full, without the written permission of the Compliance Laboratory Manager TELTEST Laboratories (A Division of Tait Communications) Telephone: 64 3 358 3399 PO Box 1645, 558 Wairakei Road, Christchurch, New Zealand. FAX: 64 3 359 4632 TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 2 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 TABLE OF CONTENTS REVISION .................................................................................................................. 3 INTRODUCTION ........................................................................................................ 4 STATEMENT OF COMPLIANCE ............................................................................... 5 MODULATION TYPES, NECESSARY BANDWIDTH & EMISSION DESIGNATORS 6 TEST RESULTS ......................................................................................................... 7 TRANSMITTER OUTPUT POWER (CONDUCTED) .............................................. 7 TRANSMITTER OCCUPIED BANDWIDTH AND SPECTRUM MASKS ................. 8 TRANSMITTER SPURIOUS EMISSIONS (CONDUCTED) .................................. 13 TRANSMITTER SPURIOUS EMISSIONS (RADIATED) ....................................... 18 TRANSMITTER FREQUENCY STABILITY - TEMPERATURE ............................ 22 TRANSMITTER FREQUENCY STABILITY - VOLTAGE ...................................... 24 RECEIVER SPURIOUS EMISSIONS (CONDUCTED) ......................................... 25 TRANSMITTER STANDBY SPURIOUS EMISSIONS (CONDUCTED) ................ 26 TEST EQUIPMENT LIST.......................................................................................... 27 ANNEX A – TEST SETUP DETAILS ........................................................................ 28 TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 3 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 REVISION Date Revision Comments 10-November-2014 1 Initial test report TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 4 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 INTRODUCTION REASON FOR REPORT This report covers the requirements of FCC 47 Parts 22 & 90, and RSS-119 Issue 11 & RSS-Gen Issue 3. Type Approval Testing of the TBCL0E Frequency range 896 Æ 941 MHz in accordance with: FCC 47 CFR Parts 22 and 90 RSS-119 Issue 11 & RSS-Gen Issue 3 REPORT PREPARED FOR Tait Communications PO Box 1645 558 Wairakei Road Christchurch New Zealand DESCRIPTION OF SAMPLE Manufacturer Tait Limited Equipment: Base Station Transceiver Type: TBCL0E Product Description Description Product Code Serial Number Firmware Version Hardware Version Power Amplifier T01-01136-QBAA 18203257 0314 01.00 Reciter T01-01105-QAZZ 18203339 Dmr-trunk.20140429T094912 00.10 PMU TBA30A0-0100 18203735 0316 01.00 Front Panel T01-01110-CCAA 18203907 0.01.00.trunk.338466.2014... 00.04 TEST CONDITIONS All testing was performed between 26 th September Æ 10 th November 2014, and under the following conditions: Ambient temperature: 15 o C Æ 30 o C Relative Humidity: 20% Æ 75% Standard Test Voltage 120 V AC TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 5 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 STATEMENT OF COMPLIANCE We, TELTEST LABORATORIES of 558 Wairakei Road, Christchurch, New Zealand, declare under our sole responsibility that the product: Equipment: Base Station Transceiver Description Product Code Serial Number Firmware Version Hardware Version Power Amplifier T01-01136-QBAA 18203257 0314 01.00 Reciter T01-01105-QAZZ 18203339 Dmr-trunk.20140429T094912 00.10 PMU TBA30A0-0100 18203735 0316 01.00 Front Panel T01-01110-CCAA 18203907 0.01.00.trunk.338466.2014... 00.04 to which this declaration relates, is in conformity with the following standards: FCC 47 CFR Parts 22 and 90 RSS-119 Issue 11 & RSS-Gen Issue 3 Signature: ___________________ Mike James Technical Manager Date: ___________________ TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 6 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 MODULATION TYPES, NECESSARY BANDWIDTH & EMISSION DESIGNATORS MODULATION TYPES: FXD Digital Data 4800 symbols/sec 9600 bps FXW Digital Voice / Data 4800 symbols/sec 9600 bps CHANNEL SPACINGS: 12.5 kHz EMISSION DESIGNATORS: DMR Digital Voice / Data 7K60FXW DMR Digital Data 7K60FXD Digital Mobile Radio (DMR) 4 level FSK (as per ETSI TS 102 361-1) 4800 symbols/sec 9600 bps Digital Data 12.5 kHz Channel Spacing – 7K60FXW 99% bandwidth Emission Designator = 7.6 kHz 7K60FXW FXW represents FM combination of data and telephony. Digital Data 12.5 kHz Channel Spacing – 7K60FXD 99% bandwidth Emission Designator = 7.6 kHz 7K60FXD FXD represents FM data only TELTEST Laboratories Tait Ltd Report Number 3605 FCC ID: CASTBCL0E Page 7 of 28 Report Revision: 1 IC : 737A-TBCL0E Issue Date: 10-November-2014 TEST RESULTS TRANSMITTER OUTPUT POWER (CONDUCTED) SPECIFICATION: FCC 47 CFR 2.1046 RSS-119 5.4 GUIDE: TIA-102.CAAA-C 2.2.1 MEASUREMENT PROCEDURE: 1. Refer Annex A for Equipment set up. 2. The coaxial attenuator has an impedance of 50 Ohms. 3. The unmodulated output power was measured wi…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 22,9 | 927 MHz - 941 MHz | 100 W | 7K60FXD | 0.5 ppm |

Base Station Transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Base Station Transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Mobile Transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Portable Transceiver
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Portable Transceiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter