Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 6 | 22,9 | 896 MHz - 940 MHz | 3 W | 8K10F1W | 0.5
ppm |
Grant NotesOutput Power listed is rated conducted output power. This transmitter must be restricted to work-related operations in an Occupational / Controlled RF exposure environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific body-worn accessories, such as antennas, belt-clips, and holsters, tested for this filing. The maximum reported SAR for head (face) and body-worn exposure conditions are 3.55 W/kg and 6.94 W/kg, respectively.