FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fujitsu Network Communications, Inc./
  3. CFD5GRUTB

CFD5GRUTBPCS Licensed Transmitter - 5G Tri Band RRH

Fujitsu Network Communications, Inc.
PCS Licensed Transmitter - 5G Tri Band RRH - FCC ID CFD5GRUTB - Fujitsu Network Communications, Inc.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Mar 22, 2021
Application Purpose
Original Equipment
Date of Application
Mar 22, 2021
Equipment Note
PCS Licensed Transmitter - 5G Tri Band RRH
Frequency Range
617.00000000 - 652.00000000
Company
Fujitsu Network Communications, Inc.
Country
United States

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

FUJITSU NETWORK COMMUNICATIONS, INC. 2801 Telecom Parkway, Richardson, Texas 75082-3515 Telephone: (972) 690-6000 (800) 777-FAST (U.S.) February 9, 2021 Federal Communications Commission 445 12th Street SW Washington, DC 20554 Attn: Director of Certification Subject: Limited Agency Agreement Fujitsu Network Communications, Inc. FCC ID: CFD5GRUTB To Whom It May Concern: Fujitsu Network Communications, Inc., hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number CFD5GRUTB under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is February 9, 2021. The Limited Agency Agreement expires on August 8, 2021, unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, _____________________________________ Corey M. Dayton Principal Compliance Engineer

Cover Letter(s)

FUJITSU NETWORK COMMUNICATIONS, INC. 2801 Telecom Parkway, Richardson, Texas 75082-3515 Telephone: (972) 690-6000 (800) 777-FAST (U.S.) July 11, 2022 Attention: Application Examiner RE: Request for Confidentiality Applicant: Fujitsu Network Communications, Inc. Model: TA08029-B130 FCC ID: CFD5G2RUTB To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by Fujitsu Network Communications, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Block Diagram • Schematics • User Manual • Internal Photographs - This product is not internally accessible to the end user because the enclosure is fastened together with special line-head (LH) security screws that cannot be removed/unfastened without a special security tool, which is not provided to any customers. An NDA between Fujitsu and their customer is also provided. • Parts List / Tune Up • Operational Description • SDR Software / Security Info Short-term Confidentiality Request is hereby submitted by Fujitsu Network Communications, Inc. to withhold from public review for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing, certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept confidential for a period of 180 days from the date of Authorization: • External Photos • Test Setup Photos These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 11 th Day of July 2022 By: Title: Signed Principal Compliance Engineer Corey M. Dayton Printed

Cover Letter(s)

1 MUTUAL NON-DISCLOSURE AGREEMENT THIS MUTUAL NON-DISCLOSURE AGREEMENT (this “Agreement”) is entered into as of [Date] (the “Effective Date”), by and between [CUSTOMER NAME] (“CUSTOMER”), having a place of business at [Customer Address] and Fujitsu Network Communications, Inc. (the “Company”), having a place of business at 2801 Telecom Parkway, Richardson, TX 75082. Each of [Customer] and the Company may be referred to in this Agreement as a “Party”, and collectively, as the “Parties”. WHEREAS, certain financial, technical and non-technical, business and other information, including, but not limited to, business plans, analyses, forecasts, predictions, projections, intellectual property, trade secrets, contracts, proposals, documents, mechanical and electronic design drawings, specifications, software, technical or engineering data, test procedures, schematics, writings, materials, methods, operations, procedures, know-how, financial information, financial statements and other business data and other information (hereinafter collectively referred to as “Data and Information”), some of which may be Confidential Information (as defined below), may be disclosed: (a) by [Customer] itself and/or through its Representatives (as defined below) to the Company itself and/or its Representatives; and/or (b) by the Company itself and/or its Representatives to [Customer] itself and/or through its Representatives, in the case of each of clause (a) and (b), the Party disclosing such information (through itself or its Representatives) being the “Disclosing Party” and the Party receiving such information (through itself or its Representatives) being the “Receiving Party”. For purposes of this Agreement, “Affiliate” means, with respect to a Party, any person or entity directly or indirectly controlling, controlled by or under common control with such Party. NOW, THEREFORE, in consideration of the terms and conditions hereinafter set forth, and other good and valuable consideration, the receipt and sufficiency of which are hereby acknowledged, the Parties mutually agree as follows: 1. This Agreement confirms the understanding between the Parties concerning a Receiving Party's obligation of strict confidentiality with respect to Confidential Information (as defined below) furnished by the Disclosing Party to a Receiving Party. For purposes of this Agreement, “Confidential Information” means any and all Data and Information received by a Receiving Party from the Disclosing Party, whether before or after the Effective Date, and whether written or oral, and if written, however produced or reproduced, which Data and Information is marked “Confidential” or “Proprietary” or bears a marking of like import, or the Disclosing Party states is to be considered confidential or proprietary, or would logically be considered confidential or proprietary, and any and all information generated therefrom. 2. This Agreement shall expire on the third (3 rd ) anniversary of the Effective Date, unless sooner terminated, renewed or extended in accordance with the terms of this Agreement. Either Party may, at any time and in its sole and absolute discretion for any reason or no reason whatsoever, terminate this Agreement upon prior written notice to the other Party. Notwithstanding the expiration or termination of this Agreement (for any reason or no reason), cessation of discussions, or the successful completion of a potential business relationship, for a period of three (3) years following the date of disclosure of Confidential Information by the 2 Disclosing Party to a Receiving Party (the “Non-Disclosure Period”), such Confidential Information shall not be disclosed to any third parties, and release of and/or access to such Confidential Information shall be restricted to those employees, officers, agents and representatives of the other Party's organization who have a need to know such Confidential Information (its “Representatives”, which term shall include such Party’s Affiliates and the employees, officers, agents and representatives of such Party’s Affiliates). For clarity, expiration or termination of this Agreement (for any reason or no reason) shall not affect the Non- Disclosure Period. All of a Party’s Representatives shall be informed of the confidential nature of the Confidential Information and the restrictions of this Agreement. Any act or omission of a Party’s Representatives that would be a breach of this Agreement if committed by the Party itself shall be deemed to be a breach of this Agreement by the Party. In the event that the Receiving Party determines that it must disclose the Disclosing Party’s Confidential Information to third parties other than its Representatives, then all such third parties must enter into a separate agreement directly with the Disclosing Party prior to any disclosure of the Disclosing Party’s Confidential Information to such third parties by the Receiving Party. The Receiving Party shall use the same degree of care to protect the secrecy and confidentiality of the Confidential Information as it uses to protect its own confidential information and in all events at least a reasonable degree of care. 3. The original and all copies of all or any part of the Disclosing Party’s Confidential Information (including, without limitation, any and all tangible embodiments of Confidential Information that are in the Receiving Party’s possession or under its control, including, without limitation, any Confidential Information that may be found in analyses, compilations, evaluations, studies or other documents based on, containing or referencing the Confidential Information provided by the Disclosing Party and/or prepared by or for the Receiving Party, whether in hard-copy or machine-readable form), shall be returned to the Disclosing Party or destroyed by the Receiving Party, in either case, promptly following written request by the Disclosing Party, except that a Receiving Party may retain a singl…

Text truncated - open the document above for the full version.

ID Label/Location Info

Copyright 20FUJITSU LIMITED20 TB RU Label & Location 0 LabelLayout for GA 1Copyright 2020 FUJITSU LIMITED FNC Label (38x10mm) WarningLabel RU Right Side View RU Left Side View Back of RU Back of RU Product Label 2 Copyright 20FUJITSU LIMITED20 Product Label INTERNAL USE ONLYINTERNAL USE ONLY Copyright 2005-2007 FUJITSU LIMITED3

RF Exposure Info

Evaluation For: Fujitsu Network Communications Product: Tri-Band RU for North America, Model TB 5G RU MPE Report Date: 3/15/2021 Non-Specific EMC Report Shell Rev. December 2017 Page 1 of 2 Report Number: 104509072LEX-003 1 FCC Limits § 1.1310: The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter. Part 1.1310 Limits for Maximum Permissible Exposure (MPE) Evaluation For: Fujitsu Network Communications Product: Tri-Band RU for North America, Model TB 5G RU MPE Report Date: 3/15/2021 Non-Specific EMC Report Shell Rev. December 2017 Page 2 of 2 Report Number: 104509072LEX-003 2 Test Procedure An MPE evaluation for was performed in order to show that the device was compliant with the general population exposure limits from FCC §2.1091. The maximum power density was calculated for each transmitter band at a separation distance of “x”cm using the maximum declared output power including tune up tolerance. For each transmitter the maximum RF exposure at a “x” cm distance using the formula: 10/)( 10 dBmowerConductedP mW PowerConducted= 푃표푤푒푟퐷푒푛푠푖푡푦= 퐶표푛푑푢푐푡푒푑⥂푃표푤푒푟 푚푊 ×퐴푛푡.퐺푎푖푛 4휋×(푥) 2 3 Results: The TB 5G RU is not supplied with an antenna. The maximum antenna gains were supplied by the manufacturer and are shown in the table below for each band. These antenna gains were used to calculate a safe separation distance such that the RF exposure levels would be equal to or less than the required limits for general population exposure for FCC Part 1.1310. As shown below the minimum safe separation distance was 1090cm (10.9 meters) for the worst case transmit band (n29). FCC MPE Data Duty Cycle100(%) Separation Dist.1090(cm) Operating ModeFrequecy (MHz) Declared Max Cond. Power (Inc. Tolerance) (dBm) Duty Cycle Adjusted Cond. Output Power (dBm) Antenna Gain (dB) MPE Value (mW/cm^2) MPE Limit (mW/cm^2) Margin to Limit (mW/cm^2) n2971752.7852.7815.70.47200.480.0060 n7161752.0552.0515.30.36390.410.0475 n2686247.6247.6216.30.16520.570.4095

Test Report

Intertek 731 Enterprise Drive Lexington, KY 40510 Tel 859 226 1000 Fax 859 226 1040 www.intertek.com Fujitsu Network Communications TEST REPORT SCOPE OF WORK EMC TESTING – TRI-BAND RU FOR NORTH AMERICA REPORT NUMBER 104509072LEX-003 ISSUE DATE 3/15/2021 PAGES 40 DOCUMENT CONTROL NUMBER Non-Specific EMC Report Shell Rev. December 2017 © 2017 INTERTEK This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. EMC TEST REPORT (FULL COMPLIANCE) Report Number: 104509072LEX-003 Project Number: G104509072 Report Issue Date: 3/15/2021 Product Tested: Model Number: Tri-Band RU for North America TB 5G RU Standards: Title 47 CFR Part 90 Title 47 CFR Part 27 Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Dr. Lexington, KY 40510 USA Fujitsu Network Communications 2801 Telcom Pkwy Richardson, TX 75082 USA Report prepared by Report reviewed by Bryan Taylor, Team Leader Brian Lackey, Staff Engineer Evaluation For: Fujitsu Network Communications Product: Tri-Band RU for North America EMC Test Report Date: 3/15/2021 Non-Specific EMC Report Shell Rev. December 2017 Page 3 of 40 Report Number: 104509072LEX-003 Table of Contents 1 Introduction and Conclusion ........................................................................................................................... 4 2 Test Summary for Band n29 (717 – 728MHz) .................................................................................................. 4 3 Test Summary for Band n71 (617 – 652MHz) .................................................................................................. 5 4 Test Summary for Band n26 (862 - 869MHz) .................................................................................................. 6 5 Client Information .......................................................................................................................................... 7 6 Description of Equipment under Test and Variant Models .............................................................................. 7 7 System Setup and Method ........................................................................................................................... 10 8 Measurement Procedures and Determination of Worst Case Modes ........................................................... 13 9 Occupied Bandwidth Data ............................................................................................................................ 14 10 Output Power and Peak / Average Ratio Data ......................................................................................... 17 11 Frequency Stability Data .......................................................................................................................... 21 12 Worst Case Conducted Spurious Emission Data ........................................................................................ 24 13 Worst Case Conducted Band Edge Emission Data ..................................................................................... 28 14 Worst Case Radiated Spurious Emissions Data ......................................................................................... 30 15 ANNEX A: Occupied Bandwidth Plots ........................................................................................................ 35 16 ANNEX B: Output Power Plots .................................................................................................................. 36 17 ANNEX C: Conducted Spurious Emission Plots ........................................................................................... 37 18 ANNEX D: Conducted Band Edge Plots ...................................................................................................... 38 19 ANNEX E: Radiated Spurious Emission Plots ............................................................................................. 39 20 Revision History ........................................................................................................................................ 40 Evaluation For: Fujitsu Network Communications Product: Tri-Band RU for North America EMC Test Report Date: 3/15/2021 Non-Specific EMC Report Shell Rev. December 2017 Page 4 of 40 Report Number: 104509072LEX-003 1 Introduction and Conclusion The tests indicated below were performed on the product described in section 6 The remaining test sections are the verbatim text from the actual data sheets used during the investigation. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary for Band n29 (717 – 728MHz) FCC Rule Test Method Test Description Measured Value Limit Results 27.5(c)(2) ANSI C63.26: 2015 Section 5.1 Frequency Ranges 5MHz BW Setting 719.5 – 725.5MHz 10MHz BW Setting 722 – 7…

Text truncated - open the document above for the full version.

Test Report

Occupied Bandwidth Plots, Band n26 Band n26, 5MHz Bandwidth Setting, QPSK Modulation, Port A 26dB Low Channel 99% Low Channel 26dB Mid Channel 99% Mid Channel 26dB High Channel 99% High Channel A 863.56 MHz * 863.56 MHz RBW 100 kHz 863.56 MHzVBW 300 kHz 863.56 MHz SWT 2.5 ms 863.56 MHz * 863.56 MHz Offset 44.5 dB 863.56 MHz LVL 863.56 MHz Ref 60 dBm 863.56 MHz Att 50 dB 863.56 MHz Center864.5 MHz 863.56 MHz Span10 MHz 863.56 MHz 1 MHz/ 863.56 MHz 1 PK 863.56 MHz MAXH 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz 863.56 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 863.56 MHz 1 Marker 1 [T1 ] 35.90 dBm 863.560000000 MHz ndB [T1] 26.00 dB BW 4.900000000 MHz T1 Temp 1 [T1 ndB] 8.61 dBm 862.060000000 MHz T2 Temp 2 [T1 ndB] 10.32 dBm 866.960000000 MHz MARKER 1 863.56 MHz Date: 18.FEB.2021 14:09:35 A 863.28 MHz Offset 44.5 dB 863.28 MHz LVL 863.28 MHz Ref 60 dBm 863.28 MHz Center864.5 MHz 863.28 MHz Span10 MHz 863.28 MHz 1 MHz/ 863.28 MHz 1 PK 863.28 MHz MAXH 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz 863.28 MHz Att 40 dB 863.28 MHz * 863.28 MHz * 863.28 MHz RBW 100 kHz 863.28 MHzVBW 300 kHz 863.28 MHz SWT 2.5 ms 863.28 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 863.28 MHz 1 Marker 1 [T1 ] 35.72 dBm 863.280000000 MHz OBW 4.500000000 MHz T1 Temp 1 [T1 OBW] 31.32 dBm 862.260000000 MHz T2 Temp 2 [T1 OBW] 30.45 dBm 866.760000000 MHz MARKER 1 863.28 MHz Date: 18.FEB.2021 14:10:08 A 864.26 MHz Offset 44.5 dB 864.26 MHz LVL 864.26 MHz Ref 60 dBm 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 864.26 MHz 1 MHz/ 864.26 MHz Center865.5 MHz 864.26 MHz Span10 MHz 864.26 MHz SWT 2.5 ms 864.26 MHz 1 PK 864.26 MHz MAXH 864.26 MHz Att 50 dB 864.26 MHz * 864.26 MHz * 864.26 MHz RBW 100 kHz 864.26 MHzVBW 300 kHz 864.26 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 864.26 MHz 1 Marker 1 [T1 ] 36.00 dBm 864.260000000 MHz ndB [T1] 26.00 dB BW 4.840000000 MHz T1 Temp 1 [T1 ndB] 10.89 dBm 863.100000000 MHz T2 Temp 2 [T1 ndB] 9.88 dBm 867.940000000 MHz MARKER 1 864.26 MHz Date: 18.FEB.2021 14:12:34 A 864.54 MHz Offset 44.5 dB 864.54 MHz LVL 864.54 MHz Ref 60 dBm 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz 864.54 MHz Att 40 dB 864.54 MHz 1 MHz/ 864.54 MHz Center865.5 MHz 864.54 MHz Span10 MHz 864.54 MHz * 864.54 MHz * 864.54 MHz RBW 100 kHz 864.54 MHzVBW 300 kHz 864.54 MHz SWT 2.5 ms 864.54 MHz 1 PK 864.54 MHz MAXH 864.54 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 864.54 MHz 1 Marker 1 [T1 ] 35.57 dBm 864.540000000 MHz OBW 4.500000000 MHz T1 Temp 1 [T1 OBW] 30.90 dBm 863.260000000 MHz T2 Temp 2 [T1 OBW] 29.79 dBm 867.760000000 MHz MARKER 1 864.54 MHz Date: 18.FEB.2021 14:12:10 A 865.28 MHz Offset 44.5 dB 865.28 MHz LVL 865.28 MHz Ref 60 dBm 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 865.28 MHz 1 PK 865.28 MHz MAXH 865.28 MHz Att 50 dB 865.28 MHz 1 MHz/ 865.28 MHz Center866.5 MHz 865.28 MHz Span10 MHz 865.28 MHz * 865.28 MHz * 865.28 MHz RBW 100 kHz 865.28 MHzVBW 300 kHz 865.28 MHz SWT 2.5 ms 865.28 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 865.28 MHz 1 Marker 1 [T1 ] 36.20 dBm 865.280000000 MHz ndB [T1] 26.00 dB BW 4.820000000 MHz T1 Temp 1 [T1 ndB] 10.54 dBm 864.100000000 MHz T2 Temp 2 [T1 ndB] 10.78 dBm 868.920000000 MHz MARKER 1 865.28 MHz Date: 18.FEB.2021 14:14:47 A 865.32 MHz Offset 44.5 dB 865.32 MHz LVL 865.32 MHz Ref 60 dBm 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 1 PK 865.32 MHz MAXH 865.32 MHz 1 MHz/ 865.32 MHz Center866.5 MHz 865.32 MHz Span10 MHz 865.32 MHz Att 40 dB 865.32 MHz * 865.32 MHz * 865.32 MHz RBW 100 kHz 865.32 MHzVBW 300 kHz 865.32 MHz SWT 2.5 ms 865.32 MHz -40 -30 -20 -10 0 10 20 30 40 50 60 865.32 MHz 1 Marker 1 [T1 ] 35.82 dBm 865.320000000 MHz OBW 4.520000000 MHz T1 Temp 1 [T1 OBW] 31.00 dBm 864.240000000 MHz T2 Temp 2 [T1 OBW] 30.78 dBm 868.760000000 MHz MARKER 1 865.32 MHz Date: 18.FEB.2021 14:15:21 Band n26, 5MHz Bandwidth Setting, 16QAM Modulation, Port A 26dB Low Channel 99% Low Channel 26dB Mid Channel 99% Mid Channel 26dB High Channel 99% High Channel A 862.82 MHz Offset 44.5 dB 862.82 MHz LVL 862.82 MHz Ref 64.5 dBm 862.82 MHz Att 30 dB 862.82 MHz * 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 862.82 MHz 1 MHz/ 862.82 MHz Center864.5 MHz 862.82 MHz Span10 MHz 862.82 MHz SWT 2.5 ms 862.82 MHz * 862.82 MHz * 862.82 MHz RBW 100 kHz 862.82 MHzVBW 300 kHz 862.82 MHz 1 PK 862.82 MHz MAXH 862.82 MHz -30 -20 -10 0 10 20 30 40 50 60 862.82 MHz 1 Marker 1 [T1 ] 36.83 dBm 862.820000000 MHz ndB [T1] 26.00 dB BW 4.840000000 MHz T1 Temp 1 [T1 ndB] 9.22 dBm 862.080000000 MHz T2 Temp 2 [T1 ndB] 11.93 dBm 866.920000000 MHz MARKER 1 862.82 MHz Date: 19.FEB.2021 15:08:34 A 863.54 MHz Offset 44.5 dB 863.54 MHz LVL 863.54 MHz Ref 64.5 dBm 863.54 MHz Att 30 dB 863.54 MHz * 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 863.54 MHz 1 MHz/ 863.54 MHz Center864.5 MHz 863.54 MHz Span10 MHz 863.54 MHz * 863.54 MHz * 863.54 MHz RBW 100 kHz 863.54 MHzVBW 300 kHz 863.54 MHz SWT 2.5 ms 863.54 MHz 1 PK 863.54 MHz MAXH 863.54 MHz -30 -20 -10 0 10 20 30 40 50 60 863.54 MHz 1 Marker 1 [T1 ] 37.22 dBm 863.540000000 MHz OBW 4.500000000 MHz T1 Temp 1 [T1 OBW] 30.65 dBm 862.260000000 MHz T2 Temp 2 [T1 OBW] 32.32 dBm 866.760000000 MHz MARKER 1 863.54 MHz Date: 19.FEB.2021 15:08:04 A 865.32 MHz Offset 44.5 dB 865.32 MHz LVL 865.32 MHz Ref 64.5 dBm 865.32 MHz Att 30 dB 865.32 MHz * 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 865.32 MHz 1 MHz/ 865.32 MHz Center865.5 MHz 865.32 MHz Span10 MHz 865.32 MHz * 865.32 MHz * 865.32 MHz RBW 100 kHz 865.32 MHzVBW 300 kHz 865.32 MHz SWT 2.5 ms 865.32 MHz 1 PK 865.32 MHz MAXH 865.32 MHz -30 -20 -10 0 10 20 30 40 50…

Text truncated - open the document above for the full version.

Test Report

Output Power: Band 26, QPSK, 5MHz, Low Channel, Port A Output Power: Band 26, QPSK, 5MHz, Mid Channel, Port A Output Power: Band 26, QPSK, 5MHz, High Channel, Port A Output Power: Band 26, 64QAM, 5MHz, Low Channel, Port A Output Power: Band 26, 64QAM, 5MHz, Mid Channel, Port A Output Power: Band 26, 64QAM, 5MHz, High Channel, Port A Output Power: Band 26, 256QAM, 5MHz, Low Channel, Port A Output Power: Band 26, 256QAM, 5MHz, Mid Channel, Port A Output Power: Band 26, 256QAM, 5MHz, High Channel, Port A Output Power: Band n29, QPSK, 10MHz, Low Channel, Port A Output Power: Band n29, QPSK, 10MHz, Mid Channel, Port A Output Power: Band n29, QPSK, 10MHz, High Channel, Port A Output Power: Band n29, QPSK, 5MHz, Low Channel, Port A Output Power: Band n29, QPSK, 5MHz, Mid Channel, Port A Output Power: Band n29, QPSK, 5MHz, High Channel, Port A Output Power: Band n29, 16QAM, 10MHz, Low Channel, Port A Output Power: Band n29, 16QAM, 10MHz, Mid Channel, Port A Output Power: Band n29, 16QAM, 10MHz, High Channel, Port A Output Power: Band n29, 16QAM, 5MHz, Low Channel, Port A Output Power: Band n29, 16QAM, 5MHz, Mid Channel, Port A Output Power: Band n29, 16QAM, 5MHz, High Channel, Port A Output Power: Band n29, 64QAM, 10MHz, Low Channel, Port A Output Power: Band n29, 64QAM, 10MHz, Mid Channel, Port A Output Power: Band n29, 64QAM, 10MHz, High Channel, Port A Output Power: Band n29, 64QAM, 5MHz, Low Channel, Port A Output Power: Band n29, 64QAM, 5MHz, Mid Channel, Port A Output Power: Band n29, 64QAM, 5MHz, High Channel, Port A Output Power: Band n29, 256QAM, 10MHz, Low Channel, Port A Output Power: Band n29, 256QAM, 10MHz, Mid Channel, Port A Output Power: Band n29, 256QAM, 10MHz, High Channel, Port A Output Power: Band n29, 256QAM, 5MHz, Low Channel, Port A Output Power: Band n29, 256QAM, 5MHz, Mid Channel, Port A Output Power: Band n29, 256QAM, 5MHz, High Channel, Port A Output Power: Band 71, QPSK, 20MHz, Low Channel, Port A Output Power: Band 71, QPSK, 20MHz, Mid Channel, Port A Output Power: Band 71, QPSK, 20MHz, High Channel, Port A Output Power: Band 71, QPSK, 10MHz, Low Channel, Port A Output Power: Band 71, QPSK, 10MHz, Mid Channel, Port A Output Power: Band 71, QPSK, 10MHz, High Channel, Port A Output Power: Band 71, QPSK, 5MHz, Low Channel, Port A Output Power: Band 71, QPSK, 5MHz, Mid Channel, Port A Output Power: Band 71, QPSK, 5MHz, High Channel, Port A Output Power: Band 71, 16QAM, 20MHz, Low Channel, Port A Output Power: Band 71, 16QAM, 20MHz, Mid Channel, Port A Output Power: Band 71, 16QAM, 20MHz, High Channel, Port A Output Power: Band 71, 16QAM, 10MHz, Low Channel, Port A Output Power: Band 71, 16QAM, 10MHz, Mid Channel, Port A Output Power: Band 71, 16QAM, 10MHz, High Channel, Port A Output Power: Band 71, 16QAM, 5MHz, Low Channel, Port A Output Power: Band 71, 16QAM, 5MHz, Mid Channel, Port A Output Power: Band 71, 16QAM, 5MHz, High Channel, Port A Output Power: Band 71, 64QAM, 20MHz, Low Channel, Port A Output Power: Band 71, 64QAM, 20MHz, Mid Channel, Port A Output Power: Band 71, 64QAM, 20MHz, High Channel, Port A Output Power: Band 71, 64QAM, 10MHz, Low Channel, Port A Output Power: Band 71, 64QAM, 10MHz, Mid Channel, Port A Output Power: Band 71, 64QAM, 10MHz, High Channel, Port A Output Power: Band 71, 64QAM, 5MHz, Low Channel, Port A Output Power: Band 71, 64QAM, 5MHz, Mid Channel, Port A Output Power: Band 71, 64QAM, 5MHz, High Channel, Port A Output Power: Band 71, 256QAM, 20MHz, Low Channel, Port A Output Power: Band 71, 256QAM, 20MHz, Mid Channel, Port A Output Power: Band 71, 256QAM, 20MHz, High Channel, Port A Output Power: Band 71, 256QAM, 10M MHz, Low Channel, Port A Output Power: Band 71, 256QAM, 10MHz, Mid Channel, Port A Output Power: Band 71, 256QAM, 10MHz, High Channel, Port A Output Power: Band 71, 256QAM, 5MHz, Low Channel, Port A Output Power: Band 71, 256QAM, 5MHz, Mid Channel, Port A Output Power: Band 71, 256QAM, 5MHz, High Channel, Port A Output Power: Band 26, NBIOT Only (GB) Low Channel, Port A Output Power: Band 26, NBIOT Only (GB) High Channel, Port A Output Power: Band 71, NBIOT Low Channel, Standalone Output Power: Band 71, NBIOT, Mid Channel, Standalone Output Power: Band 71, NBIOT High Channel, Standalone

Test Report

Band n26, 5MHz Bandwidth Setting, QPSK, Low Channel, Port A Band n26, 5MHz Bandwidth Setting, QPSK, Mid Channel, Port A Band n26, 5MHz Bandwidth Setting, QPSK, High Channel, Port A Band n26, 5MHz Bandwidth Setting, 16QAM, Low Channel, Port A Band n26, 5MHz Bandwidth Setting, 16QAM, Mid Channel, Port A Band n26, 5MHz Bandwidth Setting, 16QAM, High Channel, Port A Band n26, 5MHz Bandwidth Setting, 64QAM, Low Channel, Port A Band n26, 5MHz Bandwidth Setting, 64QAM, Mid Channel, Port A Band n26, 5MHz Bandwidth Setting, 64QAM, High Channel, Port A Band n26, 5MHz Bandwidth Setting, 256QAM, Low Channel, Port A Band n26, 5MHz Bandwidth Setting, 256QAM, Mid Channel, Port A Band n26, 5MHz Bandwidth Setting, 256QAM, High Channel, Port A Band n29, 10MHz Bandwidth Setting, QPSK, Low Channel, Port A Band n29, 10MHz Bandwidth Setting, QPSK, Mid Channel, Port A Band n29, 10MHz Bandwidth Setting, QPSK, High Channel, Port A Band n29, 5MHz Bandwidth Setting, QPSK, Low Channel, Port A Band n29, 5MHz Bandwidth Setting, QPSK, Mid Channel, Port A Band n29, 5MHz Bandwidth Setting, QPSK, High Channel, Port A Band n29, 10MHz Bandwidth Setting, 16QAM, Low Channel, Port A Band n29, 10MHz Bandwidth Setting, 16QAM, Mid Channel, Port A Band n29, 10MHz Bandwidth Setting, 16QAM, High Channel, Port A Band n29, 5MHz Bandwidth Setting, 16QAM, Low Channel, Port A Band n29, 5MHz Bandwidth Setting, 16QAM, Mid Channel, Port A Band n29, 5MHz Bandwidth Setting, 16QAM, High Channel, Port A Band n29, 10MHz Bandwidth Setting, 64QAM, Low Channel, Port A Band n29, 10MHz Bandwidth Setting, 64QAM, Mid Channel, Port A Band n29, 10MHz Bandwidth Setting, 64QAM, High Channel, Port A Band n29, 5MHz Bandwidth Setting, 64QAM, Low Channel, Port A Band n29, 5MHz Bandwidth Settin…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Corey Dayton(Principal Compliance Engineer)
[email protected]845-401-6961Fax: 972-479-2647

Technical Contact

Fujitsu Network Communications, Inc.Corey Mark Dayton
[email protected]9724792199

2801 Telecom Parkway · Richardson · United States

Test Firm

Intertek Testing Services NAJames Sudduth
[email protected]859-226-1037Fax: 859 226 1040

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
827617 MHz - 652 MHz6.46 W173KF9W1.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted RMS. This device is a mobile device with respect to RF exposure compliance and must be professionally installed. Installers must be provided with specific information required to satisfy RF exposure compliance for installations. This device has 5 MHz bandwidth mode for Band n26; 5MHz and 10 MHz bandwidth modes for Band n29; and 5 MHz, 10 MHz, and 20 MHz bandwidth modes for Band n71.

Other Applications from Fujitsu Network Communications, Inc.

CFDLN01FRUDB

PCS Licensed Transmitter - O-RAN n25/n66 FDD Dual Band Radio Unit (RU)

Dec 12, 2025

Equipment Class

PCB - PCS Licensed Transmitter
PCS Licensed Transmitter - 5G Tri Band RRH - FCC ID CFD5G2RUTB - Fujitsu Network Communications, Inc.
CFD5G2RUTB

PCS Licensed Transmitter - 5G Tri Band RRH

Aug 25, 2022

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
5G Dual Band RRH - FCC ID CFD5GRUDB3 - Fujitsu Network Communications, Inc.
CFD5GRUDB3

5G Dual Band RRH

Jul 01, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
PCS Licensed Transmitter - 5G Dual Band RRH - FCC ID CFD5GRUDB - Fujitsu Network Communications, Inc.
CFD5GRUDB

PCS Licensed Transmitter - 5G Dual Band RRH

Mar 22, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
2X2 MIMO, low-power cellular base station - FCC ID CFDLS112 - Fujitsu Network Communications, Inc.
CFDLS112

2X2 MIMO, low-power cellular base station

Aug 03, 2015

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter