Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Apr 02, 2003
Application Purpose
Original Equipment
Date of Application
Mar 04, 2003
Equipment Note
Security accessory
Frequency Range
345.00000000 - 345.00000000
Company
Ademco Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—
β†—

ID Label/Location Info

β†—

Internal Photos

β†—
β†—
β†—

Operational Description

β†—
β†—
β†—

Parts List/Tune Up Info

β†—

Schematics

β†—

Test Report

β†—
β†—
β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5800RL Cont. Industry Canada No.: CANADA: 1748A-5800RL1 REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM. FCC STATEMENT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC ID.CFS8DL5800RL-1 FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: β€’ If using an indoor antenna, have a quality outdoor antenna installed. β€’ Reorient the receiving antenna until interference is reduced or eliminated. β€’ Move the radio or television receiver away from the receiver/control. β€’ Move the antenna leads away from any wire runs to the receiver/control. β€’ Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or installer may find the following booklet prepared by the Federal Communications Commission helpful: "Interference Handbook." This booklet is available from the U.S. Government Printing Office, Washington, DC 20402. The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service. For warranty service, return product transportation prepaid, to Ademco Factory Service, 165 Eileen Way, Syosset, New York 11791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LI- ABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. Β¬1 l ALARM DEVICE MANUFACTURING CO. A DIVISION OF PITTWAY CORPORATION 165 Eileen Way, Syosset, NY 11791 Copyright Β© 1997 PITTWAY CORPORATION

Operational Description

EXHIBIT 1 CFS8DL5800RL-1 Functional Description. The 5800RL-1 remote relay is part of Ademco’s wireless 5800 alarm system. It is used in conjunction with the alarm system and provides remote activation of an alarm indicator ( bell, siren, etc.) or other devices. These messages are transmitted at 345Mhz +/-82kHz using on- off keyed AM modulation. The 5800RL-1 sends a regular supervision message, once every 72 minutes. It sends no other messages except responses to control messages initiated by the alarm system, and tamper messages.

Operational Description

EXHIBIT 2-1 Circuit Description. CFS8DL5800RL-1 The 5800RL-1 is constructed on a single PCB, which contains the RF transmitter and receiver circuitry as well as control circuits. The transmitter is a SAW resonator Colpitts oscillator, Q18, YL5 etc. The transmitter is on-off keyed (AM) modulated by a control signal from the microcontroller U6 which turns PA Q19 on or off via Q20/Q21, thus modulating the output signal. The RF output signal is connected to a PCB mounted antenna via L1,C38,R47,C82,C87. The receiver is a superhet with a single intermediate frequency at 10.7MHz. Q4 etc. is the low noise amplifier which is connected to the PCB mounted antenna. The IC U1 includes a balanced mixer which converts the incoming signal down from 345MHz to 10.7MHz. This IC also includes the required IF gain and detected output. YL1 and YL2 are IF filters. IC U2 and U3 perform video filtering and processing to provide a data signal to the microcontroler U6. The local oscillator is part of the receiver IC U1 SAW device YL3 is the frequency- determining component. 343.3 MHz is fed into the mixer.

Operational Description

EXHIBIT 3 CFS8DL5800RL-1 Message protocol, timing and duty cycle calculation. The data output is phase encoded Manchester which has inherent 50% duty cycle. The transmitted data rate is 3.95 kBs +/-0.5%, i.e. each bit is 253.1uS duration typical and 254.3uS max. The worst case data format consists of 120 bits, The duration of each word is 30.51 mSec max. Each word is transmitted 6 times at each transmission event, the words are separated (start to start) by 102mSec. The total max transmission time at each transmission event is 540.51mSec. The duty cycle over a 100mSec measuring period is calculated as follows: Duty Cycle = Actual RF transmission ON time / 100mSec (interval) Actual transmission ON time = 120 bits X 50% X 254.3uSec = = 15.26mSec Therefore Duty cycle = 15.26 / 100 mSec = .1526 =15.26%

Parts List/Tune Up Info

EXHIBIT 6 CFS8DL5800RL1 Test Equipment list 1. Antenna: RGA-60 S/N: 6127 Cal. on: 05/31/02 Cal. due: 05/31/03 2. Antenna: Log Periodic S/N:365 Cal. on: 06/30/02 Cal. due: 06/30/03 3. Spectrum Analyzer H. P. 8563E S/N: 3246A00232 Cal. on: 03/01/02 Cal. due: 03/01/03

Test Report

EXHIBIT 5 CFS8DL5800RL-1 Report of Measurements. Measurements were made at Ademco 's Measurement Facility at 160 Eileen Way , Syosset , NY 11791 , FCC Registration number : 90421. Measurements were made in accordance with the procedures and reporting requirements of ANSI C63.4-1992. The Test Set-Up (C63.4 section 10.1.3) is shown in the attached drawing. The sequence of testing (C63.4 section 10.1.7) for radiated emissions is as follows: A preliminary scan was conducted with the receiver antenna close to the EUT in order to identify the emission characteristics of the EUT (C63.4 section 8.3.1.1). The antenna and EUT were then placed at the proper separation with the EUT positioned on a non-conducting turntable. The EUT was rotated on the turntable to maximize the received signal strength, then the receiver antenna height was varied to further maximize the received reading. Thereafter, the device was again rotated to a peak output position and the antenna height was re-adjusted for maximum received signal. This procedure was re-iterated until there was no further increase in signal level. This procedure was performed with the EUT rotating in three orthogonal planes (C63.4 section 13.1.4.1) to generate a final maximum reading which is recorded on the radiated emissions result sheet. Similar measurements were made on the receiver to ensure compliance as an unintentional radiator. See Exhibit 6 for list of test equipment (C63.4 section 10.1.4). Note, Spectrum Analyzer resolution bandwidths set as follows; (Video Bandwidth set greater than RBW) - For occupied bandwidth measurements, RBW = 100kHz, (This is in accordance with the minimum RBW allowed by C63.4, which requires RBW greater than 5% of the FCC required occupied bandwidth spec of 0.25% of center frequency). - For radiated emissions below 1 GHz, the RBW = 100kHz. Detector function set to peak. - For radiated emissions above 1 GHz, the RBW = 1MHz. Detector function set to peak. OCCUPIED BANDWIDTH is shown on attached plot. RADIATED EMISSIONS are recorded on attached sheet.

Test Report

Frequency (MHz) Antenna Polarity ( V-H ) Meter Reading (dB uV) Cable/Amp Factor ( dB ) Antenna Factor (dB/M) Converted Reading ( uV/M ) Duty Cycle ( % ) Corrected Reading ( uV/M ) Limit @ 3 Meter ( uV/M ) 30 H 15 729 345 H 66.00 2.316.1116,615 15 2,492.3 7,291 690 H 29.17 3.221.46491.5 15 73.7 729 1035 H 15.83 3.925.47182.0 15 27.3 500 1380 H 30.00 4.629.351,575.8 15 236.4 500 1725 V 26.33 5.331.301,401.2 15 210.2 729 2070 H 28.26 6.328.26212.8 15 31.9 729 2415 H 29.53 6.829.53260.9 15 39.1 729 2760 H 30.18 7.030.18287.7 15 43.1 729 3105 H 30.76 7.430.76322.1 15 48.3 729 3450 H 31.70 12.031.70690.5 15 103.6 729 4000 H 15 729 FEBRUARY, 10, 2003 GREG BARBATO KEN ADDY DATE:____________________ TESTED BY:_________________________APPROVED BY:________________________ ADEMCO 5800RL-1 (TRANSMITTER) TEST SAMPLE (model): _______________________________________________________________________________ TEST METHOD: ANSI C63.4-1992 TEST SPECIFICATION: FCC PART 15, SUBPART C. NOTES: 1) Fo= 345 MHZ 2) DETECTOR = PEAK. 3) FREQUENCY RANGE SCANNED TO 4 GHz. (METER READING +CABLE /AMP FACTOR +ANTENNA FACTOR) 20 4) CONVERTED READING = 10 5) CORRECTED READING = CONVERTED READING X DUTY CYCLE 6) SIX HIGHEST EMISSIONS RECORDED. ALARM DEVICE MANUFACTURING COMPANY 165 EILEEN WAY CFS8DL5800RL-1 SYOSSET, NY 11791 FCC ID#____________________

Test Report

OCCUPIED BANDWIDTH OF CFS8DL5800RL1

Test Report

Frequency (MHz) Antenna Polarity ( V-H ) Meter Reading (dB uV) Cable/Amp Factor ( dB ) Antenna Factor (dB/M) Converted Reading ( uV/M ) Duty Cycle ( % ) Corrected Reading ( uV/M ) Limit @ 3 Meter ( uV/M ) 30----------------------- ----------- ------------------------------------------------- 100 334.3 H 10.17 2.3 16.11 26.85 NA 26.85 200 4000--------------------- ------------ --------------------------------------------------- 500 NOTES: FEBRUARY, 10, 2003 GREG BARBATO KEN ADDY DATE:____________________ TESTED BY:_________________________APPROVED BY:________________________ ADEMCO 5800RL1 ( RECEIVER ) TEST SAMPLE (model): _______________________________________________________________________________ TEST METHOD: ANSI C63.4-1992 TEST SPECIFICATION: FCC PART 15, SUBPART C. NOTES: 1) L.O.: 343.3 MHZ 2) DETECTOR = PEAK. 3) FREQUENCY RANGE SCANNED TO 4 GHz. (METER READING +CABLE /AMP FACTOR +ANTENNA FACTOR) 20 4) CONVERTED READING = 10 5) CORRECTED READING = CONVERTED READING X DUTY CYCLE 6) SIX HIGHEST EMISSIONS RECORDED. ALARM DEVICE MANUFACTURING COMPANY 165 EILEEN WAY SYOSSET, NY 11791 FCC ID#__CFS8DL5800RL-1___

Contact Information

Applicant

Christian Fouth(Sr. Wireless Certification Engineer)
[email protected]15406566372Fax: 17639544816

Technical Contact

Alarm Device Manufacturing CompanyKen L Addy
[email protected]

A Division of Pittway Corporation Β· Syosset, New York Β· United States

Non-Technical Contact

Alarm Device Manufacturing CompanyKen L Addy
[email protected]

Test Firm

AdemcoKenneth Addy
[email protected]516-921-6704Fax: 516-921-4545

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-

Other Applications from Ademco Inc.

Wireless Alarm Transmitter - FCC ID CFS8DL5800MINIV - Resideo LLC.
CFS8DL5800MINIV

Wireless Alarm Transmitter

Jan 28, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Alarm Transmitter - FCC ID CFS8DLWTS800 - Resideo LLC.
CFS8DLWTS800

Wireless Alarm Transmitter

Jan 12, 2026

Equipment Class

DTS - Digital Transmission System
CFS8DLCAMWEWI1

VX5 HD Indoor Camera

Jul 25, 2024

Equipment Class

DTS - Digital Transmission System
VX3 HD Outdoor Camera - FCC ID CFS8DLCAMWEWO1 - Ademco Inc.
CFS8DLCAMWEWO1

VX3 HD Outdoor Camera

Sep 17, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Wireless door/window contact - FCC ID CFS8DLLMD500A - Ademco Inc.
CFS8DLLMD500A

Wireless door/window contact

Jul 20, 2023

Equipment Class

DTS - Digital Transmission System