K5623V2 10/07 Rev. A (Preliminary) LIMITED WARRANTY Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 2 Corporate Center Drive, Melville, NY, 11747, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to your local authorized Honeywell representative. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire , or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. This device complies with Part 15 of FCC rules and RSS 210 of IC. Operation is subject to the following two conditions: (1) this device may not cause harmful interference. (2) this device must accept any interference received, including interference that may cause undesired operation. Note: The user shall not make any changes or modifications to the equipment unless authorized by the Installation and Setup Guide or User Guide. Unauthorized changes or modifications could void the user's authority to operate the equipment. U L For dry, indoor use only. Do not install in air-handling spaces. ÊK5623V2PŠ 2 Corporate Center Drive, Suite 100 P.O. Box 9040 Melville, NY 11747 Copyright © 2007 Honeywell International Inc. www.security.honeywell.com Preliminary K5623V2 10/07 Rev. A ADEMCO 5817CB WIRELESS COMMERCIAL / HOUSEHOLD TRANSMITTER INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The 5817CB is a universal contact-monitoring transmitter that can be used with household and commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations, and remote duct detectors. Upon activation, it emits an RF signal to a control panel that sends a burglary or fire alarm to a central station. The 5817CB has three unique input loops (zones). The first loop (primary loop) is supervised and typically used for high-priority alarm reporting such as commercial fire or burglary. It requires a 470K ohm end-of-line resistor to be placed across the sensor. The second loop is the built-in, normally closed reed switch (used in conjunction with a magnet, as described below). The third loop is another normally closed household burglary loop. All three loops may be used. A fourth (automatically enrolled) loop contains two tamper switches to protect the 5817CB transmitter. A built-in cover tamper switch is activated when the cover is removed. A unit tamper switch is activated if the unit is separated from its mounting plate. PROGRAMMING The 5817CB has its own unique serial number permanently assigned during manufacture. You must "enroll" this transmitter serial number in the control panel at some point prior to its usage in the alarm system. Refer to the control panel's installation instructions for specific programming procedure. Note: During programming of the control panel, program the 5817CB transmitter as Input Type "RF" (i.e., supervised RF) ( mandatory for UL installations ). MOUNTING For proper orientation of the unit in relation to its wall mounting plate and the loop wiring, read all of this section before installing the unit. Signal strength may vary from location to location. Before mounting the transmitter permanently, conduct Go/No Go tests (see control'…
Text truncated - open the document above for the full version.
EXHIBIT 4—1 TOP PLASTIC CFS8DL5817CB-2 / 573F-5817CB2
EXHIBIT 4—2 BOTTOM PLASTIC CFS8DL5817CB-2 / 573F-5817CB2
EXHIBIT 8 LABEL INFORMATION CFS8DL5817CB-2 / 573F-5817CB2 SECTION 2.1033 (c) and Part 15.21 SECTION 2.1033 (c) Label and label location - A photo showing the identification label clearly (you must be able to see the name and FCC ID number), and the location on the device. In lieu of a photo for this, you may submit a engineer’s drawing. Part 15.21 & RSS 210 Statement - for all intentional and unintentional radiators is also printed on the label. All devices shall bear the following statement in a conspicuous location on the device: “ This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada . Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. “ The Label shall also display the IC ID and a IC Model Number. OUR TEXT READS: HONEYWELL 5817CB This device complies with Part 15 of FCC & RSS 210 of Industry Canada. Operation is subject To the following two conditions: (1)This device may not cause harmful in- terference, and (2)This device must accept any interference received, including inter- ference that may cause undesired operation. FCC ID: CFS8DL5817CB-2 IC: 573F-5817CB2 IC MODEL: 5817CB2 K14946 Rev. A 10/07 THIS IS THE LOCATION OF THE LABEL ON THE BACK PLASTIC: PLEASE SEE PAGE 2 FOR THE ACTUAL ENGINEERS DRAWING OF THE LABEL. AWK14946 10/07 K14946 Rev. A 10/07 FCC ID: CFS8DL5817CB-2 IC: 573F-5817CB2 IC MODEL: 5817CB2 5817CB This device complies with Part 15 of FCC & RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful in- terference, and (2) this device must accept any interference received, including inter- ference that may cause undesired operation. K14946 K14946 Rev. A 10/07 FCC ID: CFS8DL5817CB-2 IC: 573F-5817CB2 IC MODEL: 5817CB2 5817CB This device complies with Part 15 of FCC & RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful in- terference, and (2) this device must accept any interference received, including inter- ference that may cause undesired operation. K14946
EXHIBIT 4—3 PCB IN PLASTIC CFS8DL5817CB-2 / 573F-5817CB2
EXHIBIT 4-4 PCB TOP CFS8DL5817CB-2 / 573F-5817CB2
EXHIBIT 1 CFS8DL5817CB-2 / 573F-5817CB2 Functional Description. The 5817CB-2 is a battery powered portable transmitter and is part of a wireless alarm system. It is used in conjunction with a receiver (5881) to indicate an open door or window to the alarm system. It is functionaly identical to the 5817CB. The messages are transmitted at 345Mhz +/-82Khz using on-off keyed AM modulation. The 5817CB-1 sends a regular supervision or check-in message, no more often than once per hour. It also sends messages initiated by the condition of the loop (open or closed).
EXHIBIT 2-2 CFS8DL5817CB-2 / 573F-5817CB2 The 5817CB-2 remote zone transmitter consists of a message encoding chip (U1) , a SAW - stabilized Colpits oscillator (Q2) , and PA stage (Q3). The message encoding chip is responsible for: 1. generating the zone alarm message 2. generating the tamper and supervision messages. 3. performing all watchdog functions. When sending a message, the message encoder chip turns on the SAW oscillator (Q2) using Q1 to apply VCC , R7 and R8 bias Q2 on, SAW device Y1 sets the frequency, capacitors C10 and C11 set the feedback , R9 sets the current through the oscillator, and C13 couples the RF into the PA. The encoder chip then uses transistors Q4 - 5 to key the PA (Q3). This is on / off AM modulation (FCC Type 100KK1 modulation )C19 and L1 tune the PA, C15, RL27, suppress harmonics, and C17 / C18 tune the antenna to resonance.
EXHIBIT 3-1 CFS8DL5817CB-2 / 573F-5817CB2 5817CB-1 Duty Cycle Calculation: Message protocol, timing and duty cycle calculation. The data output is phase-encoded Manchester that has inherent 50% duty cycle and consists of 64 bits per word A supervision transmission is six identical words separated by (start to start) by nominal 125mSec (100 mSec min, 150 mSec max). Each message has a nominal data rate of 3.7 kb/s (3.2kb/s min to 4.2kb/s max). Therefore the duty cycle is calculation is as follows: The word format consists of 64 bits, The duration of each bit is 312.5 uSec max. The duty cycle over a 100 mSec measuring period is calculated as follows: Duty cycle = Actual RF transmission ON time / 100 mSec Actual transmission ON time = 64 bits X 50% X 312.5 uSec = 10 mSec Therefore duty cycle = 10 / 100 mSec = .10 = 10%, and peak to average field strength is 20 db. Total on-air time for a supervision transmission is: 64 X 312.5 uSec + (5 X 150 mSec) = 0.77 seconds In the case of an alarm transmission, the group of six transmissions is repeated twice, with the second group delayed from the first by a max time of 2 seconds. The worst case on-air time is 2 X (supervision time) + 2 = 3.54 seconds Summary: - Duty cycle = 10% On airtime = 3.54 seconds
EXHIBIT 3-2 TIMING DIAGRAM CFS8DL5817CB-2 / 573F-5817CB2 Section 15.255(b) Section 15.255(b), when the radiated emission limits are expressed in terms of the average value of the emission, and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. The exact method of calculating the average field strength shall be submitted with any application for certification. SEE THE NEXT PAGE
EXHIBIT 5-1 CFS8DL5817CB-2 / 573F-5817CB2 Report of Measurements. Measurements for Radiated Emissions were made in accordance with the procedures an d reporting requirements at: Honeywell's OATS ( FCC No: 152762 & IC No:573F-1 ) both of which are located at: 2 Corporate Center Drive, Melville, NY 11747 The test report consists of the following exhibits: REPORT OF MEASUREMENTS ( This EXHIBIT ) EXHIBIT 5-1 PICTURES OF THE TEST SET UP are found in EXHIBIT 5-2 RADIATED EMISSIONS are recorded in EXHIBIT 5-3 BANDWIDTH MASK is recorded in EXHIBIT 5-4 TEST EQUIPMENT USED is recorded in EXHIBIT 6
HONEYWELL SECURITY & CUSTOM ELECTRONICSREV B SEPT 07 2 Corporate Center Drive Melville, NY 11747EXHIBIT 5-3 FCC ID # CFS8DL5817CB-2 Date : 09/18/2007 Tested by : Yasseen Mohammed Approved by :K.Addy Test Sample (model) : 5817CB-2 Test method: ANSI C63.4 - 2004 Test specification: FCC Part 15, Sub-part C and RSS 210 , Issue 7 Notes: (1) Fo = 345MHz. (2) Detector = Peak (3) Frequency range scanned to 4 GHz. Emissions not reported were more than 20dB below the specified unit. [(Meter reading + Cable/Amp factor + Antenna factor) / 20 )] (4) Conv. Reading = 10 (5) Corr. Reading = Conv. Reading X Duty Cycle (6) Six Highest Emissions Recorded Freq. (MHz) Antenna Polarity (V/H) Meter Reading (dB uV) Cable/Amp Factor (dB) Antenna Factor (dB/m) Conv. Reading (uV/M) Duty Cycle (%) Corr. Reading (uV/M) Limit @ 3M (uV/M) 30 CABLE "A" + "B" 03/12/2007 BICONILOG S/N:00029390 729 345h77.602.614.9056885.310.0%5688.57292 690h42.203.719.301819.710.0%182.0729 1035h32.804.722.701023.310.0%102.3500 1380h37.405.525.802722.710.0%272.3500 1725h32.606.328.002213.110.0%221.3729 2070h36.307.030.304786.310.0%478.6729 2415h26.307.632.001972.410.0%197.2729 2760 h 26.308.5 32.802398.810.0%239.9500 3105h25.309.032.502187.810.0%218.8729 3450h25.0010.733.002722.710.0%272.3729 4000 CABLE "A" + "B" 03/12/2007 BICONILOG S/N:00029390
EXHIBIT 5-4 CFS8DL5817CB-2 / 573F-5817CB2 5817CB-2 OCCUPIED BANDWIDTH (619 KHz)
EXHIBIT 6 TEST EQUIPMENT USED CFS8DL5817CB-2 / 573F-5817CB2 Section 15.231 and ANSI C63.4 Section 15.231, per C63.4. This is a list of all test equipment used. Test Equipment list 1. Antenna: BICONOLOG S/N: 00045682 Cal. on: 05/10/07 Cal. due: 05/10/08 2. Spectrum Analyzer TEK 2784 S/N: B010165 Cal. on: 10/16/06 Cal. due: 10/15/07
EXHIBIT 5-2 PHOTOS OF UNIT UNDER TEST CFS8DL5817CB-2 / 573F-5817CB2 THE INTENTIONAL RADIATOR EMISSIONS WERE DONE ON HONEYWELL’S OATS MEASUREMENT FACILITY ( FCC No: 152762 & IC No: 573F-1 ) LOCATED AT 2 CORPORATE CENTER DRIVE, MELVILLE, NY 11747. SENSE ANT HORIZONTAL: UUT VERTICAL: UUT HORIZONTAL: UUT OBLIQUE: SENSE ANT VERTICAL: UUT VERTICAL: UUT HORIZONTAL: UUT OBLIQUE: TEST SITE: TEST EQUIPMENT: THE TEST TECH:
2 Corporate Center Drive · Melville, New York · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 345 MHz - 345 MHz | - |

Wireless Alarm Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Alarm Transmitter
Equipment Class
DTS - Digital Transmission SystemVX5 HD Indoor Camera
Equipment Class
DTS - Digital Transmission System
VX3 HD Outdoor Camera
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Wireless door/window contact
Equipment Class
DTS - Digital Transmission System