Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PREK4460-1V5 8/05 Rev A ADEMCO 6150RF ADEMCO 6150RFADEMCO 6150RF ADEMCO 6150RF Keypad/Transceiver Keypad/TransceiverKeypad/Transceiver Keypad/Transceiver INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The 6150RF Keypad/Transceiver is a combination unit incorp- orating a normally-open relay output and the functions of: • 6150 Fixed Addressable Keypad • 5881M RF Receiver • 5800TM Transmitter Module The 6150RF Keypad/Transceiver may be used on any control panel that supports the 6150 Keypad (e.g., VISTA-10P/10SE, VISTA-15/15P, VISTA-20P/20SE/20HWSE, VISTA-40, VISTA- 50P, VISTA-128B/128BP, 4110DL, 4110XM, 4140XMP) Wireless Features The 6150RF supports the following: • 5828/5828V wireless keypads. • Up to 8 wireless keys locally (programmed directly into 6150RF) without occupying any zones supported by the control panel. • Button-type transmitters (e.g., 5804, 5804BD) for local operation. • A maximum of 16 transmitters programmed into any 5800 Series-supported control panel. • Wireless keys with high-security (e.g., 5804E). • RF jam detection when the receiver is enabled. The 6150 provides the following: • Low-battery indications for the local wireless keys. • A nominal range of 200' for the RF transmitters (some transmitters have a shorter range). • Wireless key support for control panels that do not support RF themselves (such as 4110DL). U UU U L LL L The 5802, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5804WATCH, 5805BDV, 5814, 5816TEMP, 5819, 5819SBRS, 5819SWHS, and 5850 transmitters are not intended for UL installations. Programming Features • Auto Enroll mode for programming wireless keys. • Provides a method for deleting a serial number and re- enrolling a new one in its place. • Provides default settings for the wireless key functions. Additional Features • Sends status signals (Armed, Ready, etc.) to bi-directional units such as 5804BDV, 5805BDV and 5828/5828V. • Operates the on-board relay in conjunction with the receiver (e.g., to trip a garage door opener). Note: This particular feature is not intended for UL installations. • Activates relays programmed into the control panel. • Provides an End User mode to enable/disable local wireless keys (e.g., if a user accidentally loses a wireless key). (Refer to the 6150RF User Guide for this procedure.) APPLICATION GUIDELINES Use the following guidelines when planning an installation: • Local wireless keys (wireless keys programmed directly into the 6150RF) may be used regardless of whether the RF receiver in the 6150RF is enabled or disabled. • If using bi-directional devices, be sure to enable the transmitter module in the 6150RF. • If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not exceed the number of receivers supported by the control panel.) • If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be entered into the 6150RF. This user code must also be programmed into the control panel. • You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID Source is the 6150RF (Local). 6150RF Application Guide The following guide outlines how to program the wireless keys, RF receiver, and the House ID in the 6150RF for your installation. * Two 6150RFs are needed for this application: one assigned to partition 1 and one assigned to partition 2. ** If using an RF keypad on only one partition, the 6150RF’s partition assignment must match the partition set in field 1*48. *** If set for Local on a partition control, the 6150RF’s partition assignment must match the one programmed in the BD device. Are you using 6150RF Programming Options System Control Panel RF keys beyond system’s capacity? RF receivers beyond system’s capacity? RF keypads and/or Bi- directional devices on more than 1 partition? Program Wireless Keys Into Receiver Enable House ID Source*** 4110DL, 4110XM, 4140XMP, VISTA- 20HWSE N/A N/A N/A 6150RF OFF Local [0] NO NO N/A System ON [1] System [1] YES NO N/A 6150RF ON [1] System [1] VISTA-10P, VISTA-10SE, VISTA-15, VISTA-15P, VIA-30PSE YES YES N/A 6150RF OFF [0] Local [0] NO NO NO System ON [1] System [1] YES NO NO 6150RF ON [1] System [1] YES YES NO 6150RF OFF [0] Local [0] NO YES YES* System OFF [0] Local [0] VISTA-20SE, VISTA-20P YES YES YES* 6150RF OFF [0] Local [0] NO NO NO** System ON [1] System [1] YES NO NO** 6150RF ON [1] System [1] YES YES NO** 6150RF OFF [0] Local [0] NO YES YES System OFF [0] Local [0] VISTA-40, VISTA-50P, VISTA-128B, VISTA-128BP YES YES YES 6150RF OFF [0] Local [0] - 7 - SPECIFICATIONS Physical: 6-1/4” H x 4-7/8” W x 1” D (158.75mm x 123.8mm x 25.4mm) Wiring: Refer to Wiring Table on page 2 Range: 200' nominal Frequency: 345 MHz Voltage: 12VDC Current: Standby 80mA Backlighting on and Sounder on 105mA Relay: Normally-Open, 1A, 28VDC Sounder: Piezo-electric (fire alarm is loud pulsing tone; burglary/audible panic alarm is two tone sound FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED. FCC ID: CFS8DL6150RFT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. IC: 573F-6150RFT FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manu- facturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the spe…
Text truncated - open the document above for the full version.
COVER LETTER Federal Communications Commission Honeywell International Inc. Equipment Approval Services Radio Engineering PO BOX 358315 160 Eileen Way Pittsburgh, PA 15251 5315 Syosset, NY 11791 December,20, 2005 Subject: Application for Certification of Honeywell’s Security Device type: 6150RFT FCC ID: CFS8DL6150RFT Dear Sir or Madam: Please find (e-filed) a 731 application form and 159 payment form for submittal of this product. The following exhibits were also uploaded to your site: • functional description • circuit description • block diagram • schematic • duty cycle / timing calculation • timing diagram • external and internal photos • product test report • users manual • label This is for the certification of Honeywell’s 6150RTF transceiver under FCC rules and regulations Part 15 subpart C. If you have any questions or require additional information, please contact me at 516-921-6704 Ext. 6640 Regards, Ken Addy Director Radio Engineering
EXHIBIT 8 THE FCC PART 15 LABEL CFS8DL6150RFT SECTION 2.1033 (c) and Part 15.21 SECTION 2.1033 (c) Label and label location - A photo showing the identification label clearly (you must be able to see the name and FCC ID number), and the location on the device. In lieu of a photo for this, you may submit a engineer’s drawing. Part 15.21 Statement - for all intentional and unintentional radiators is also printed on the label. All devices shall bear the following statement in a conspicuous location on the device: “ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. “ IC: 573F-6150RFT FCC ID: CFS8DL6150RFT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EXHIBIT 1 Functional Description. CFS8DL6150RFT Functional Description. The 6150RFT fixed transceiver is part of Ademco’s wireless 5800 alarm system. It is used in conjunction with portable transmitters (e.g. 5804) or portable transceivers (e.g. 5804BD). This allows remote control of the alarm system and provides remote indication that a control instruction has been enacted. These messages are transmitted at 345Mhz +/-82kHz using on-off keyed AM modulation. The 6150RFT does not send a regular supervision or check-in message, it transmits no other messages except those which are a confirmation of reception of manually initiated control messages which have been received from portable remote control transmitters and control and alarm messages.
EXHIBIT 2-1 CIRCUIT DESCRIPTION CFS8DL6150RFT SECTION 2.1033(b) SECTION 2.1033(b) (2a). For Part 15 a statement describing how the device operates. The 6150RFT consists of a single chip transmitter (U4) under control of the microprocessor (U5) , the transmitters FDE is crystal (YL2; 10.78125 MHz X 32 = 345 MHz ) and it’s output is matched to 50 ohms ( by:L1, C19, L2, etc.). This output is fed via the transmit / receive switch (SW2) to the diversity antenna switch (CR25, CR27, etc.) which in turn feeds ANT1 and ANT2 via there respective matching circuits (C31,L7 etc, and C37,L6 etc.) that microprocessor (U5) also controls the T/R and antenna switches. During receive the same diversity antenna system and transmit / receive switch feeds filter (FL2) and the single chip receiver (U9) the receiver is a single conversion ‘superhet’ with a internal phase locked LO who’s FDE is crystal (YL5; 20.89375 MHz. X 16 = 334.3 MHz , i.e., 345 – 334.3 = 10.7 MHz IF) IF band pass is provided by the 10.7 MHz filter (FL1) the raw base-band is processed by the processing circuit (U7 , U8, etc.) and sent to microprocessor (U5) for final processing.
EXHIBIT 3-1 CFS8DL6150RFT Duty Cycle calculation Total number of bytes: 15 bytes Nominal base band frequency: 4Khz (250usec/bit) Total time = 15 x 250usec x 8(bits/byte) = 30 msec Because of Manchester encoding (50% duty cycle) On time is: 30msec x0.5 = 15 msec Therefore, TM2 message Duty Cycle is = 15msec/100msec= 15%
CFS8DL6150RFT Transmission Format Serialized data is Manchester Phase Encoded as shown below. Bit stream is sent out on a most significant bit first fashion. Message redundancy and RF Spatial diversity are implemented by transmitting six identical messages (sextet) on alternating antennae (three messages are transmitted on each antenna). Message Format – It contains a total of 15 bytes, two bytes of preamble and 13 bytes of data. 16 bits + 13 bytes sent at 4K bits/sec (2msec/byte) = 30msec Preamble House Code L0 L1 L2 L3. CRC1 Cancel,Night/Msg. Type V0 V1 V2 CRC2 16 bits 0 1 2 3 4 5-6 7 8 9 10 11-12 All bytes are transmitted Most significant bit first Preamble is FFFE (hex) and is used for data synchronization purposes. 1 1 1 0 1 0 1 0 0 1 1 0 0 0 1 Bit Cell Interval = 250 usec (4Khz) 30msec. 100 msec approx. Single sextet Format Transmission Direction
L.STERNSTEIN 3/14/05
EXHIBIT 5-1 CFS8DL6150RFT Report of Measurements. Measurements were made at Honeywells Measurement Facility at 160 Eileen Way , Syosset , NY 11791 , FCC Registration number : 90421. Measurements were made in accordance with the procedures and reporting requirements of ANSI C63.4-1992. The Test Set-Up (C63.4 section 10.1.3) is shown in the attached drawing. The sequence of testing (C63.4 section 10.1.7) for radiated emissions is as follows: A preliminary scan was conducted with the receiver antenna close to the EUT in order to identify the emission characteristics of the EUT (C63.4 section 8.3.1.1). The antenna and EUT were then placed at the proper separation with the EUT positioned on a non-conducting turntable. The EUT was rotated on the turntable to maximize the received signal strength, then the receiver antenna height was varied to further maximize the received reading. Thereafter, the device was again rotated to a peak output position and the antenna height was re-adjusted for maximum received signal. This procedure was re-iterated until there was no further increase in signal level. This procedure was performed with the EUT rotating in three orthogonal planes (C63.4 section 13.1.4.1) to generate a final maximum reading which is recorded on the radiated emissions result sheet. Similar measurements were made on the receiver to ensure compliance as an unintentional radiator. See Exhibit 6 for list of test equipment (C63.4 section 10.1.4). Note, Spectrum Analyzer resolution bandwidths set as follows; (Video Bandwidth set greater than RBW) - For occupied bandwidth measurements, RBW = 100kHz, (This is in accordance with the minimum RBW allowed by C63.4, which requires RBW greater than 5% of the FCC required occupied bandwidth spec of 0.25% of center frequency). - For radiated emissions below 1 GHz, the RBW = 100kHz. Detector function set to peak. - For radiated emissions above 1 GHz, the RBW = 1MHz. Detector function set to peak. OCCUPIED BANDWIDTH is shown on attached plot. RADIATED EMISSIONS are recorded on attached sheet.
HONEYWELL SECURITY & CUSTOM ELECTRONICS 165 EILEEN WA Y SYOSSET, NY 11791EXHIBIT 5-3 FCC ID # CFS8DL6150RFT Date :12/6/2005 Tested by :Y. Mohammed Approved by :K.Addy Test Sample (model) : 6150RFAS-T3 Test method: ANSI C63.4 - 1992 Test specification: FCC Part 15, Sub-part C Notes: (1) Fo = 345MHz. (2) Detector = Peak (3) Frequency range scanned to 4 GHz. Emissions not reported were more than 20dB below the specified unit. [(Meter reading + Cable/Amp factor + Antenna factor) / 20 )] (4) Conv. Reading = 10 (5) Corr. Reading = Conv. Reading X Duty Cycle (6) Six Highest Emissions Recorded Freq. (MHz) Antenna Polarity (V/H) Meter Reading (dB uV) Cable/Amp Factor (dB) Antenna Factor (dB/M) Conv. Reading (uV/M) Duty Cycle (%) Corr. Reading (uV/M) Limit @ 3M (uV/M) 30 CABLE "A"BICONILOG729 345H77.601.214.7847752.915.0%7162.97292 690H45.001.819.101972.415.0%295.9729 1035H38.002.222.701396.415.0%209.5500 1380H28.002.524.96592.915.0%88.9500 1725H28.002.827.55827.015.0%124.0729 2070H28.003.029.521061.715.0%159.3729 2415H28.003.331.131322.815.0%198.4729 2760 H 28.003.7 31.501445.415.0%216.8729 3105H28.004.131.611532.915.0%229.9729 3450H28.004.432.221702.215.0%255.3729 4000 CABLE "A"BICONILOG
6150RFT OCCUPIED BANDWIDTH (451 KHz)
EXHIBIT 6 TEST EQUIPMENT USED CFS8DL6150RFT Section 15.231 and ANSI C63.4 Section 15.231, per C63.4 section 10.1.4. This is a list of all test equipment used. Test Equipment list 1. Antenna: BICONOLOG S/N: 00029290 Cal. on: 09/14/04 Cal. due: 09/14/05 2. Spectrum Analyzer H. P. 8563E S/N:3246A00232 Cal. on: 08/23/04 Cal. due: 08/23/05
165 Eileen Way · Syosset, New York · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 345 MHz - 345 MHz | - |

Wireless Alarm Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Alarm Transmitter
Equipment Class
DTS - Digital Transmission SystemVX5 HD Indoor Camera
Equipment Class
DTS - Digital Transmission System
VX3 HD Outdoor Camera
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Wireless door/window contact
Equipment Class
DTS - Digital Transmission System