FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nedap N. V./
  3. CGDVP1006B

CGDVP1006BRFID Device

Nedap N. V.
RFID Device - FCC ID CGDVP1006B - Nedap N. V.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 12, 2020
Application Purpose
Original Equipment
Date of Application
May 12, 2020
Equipment Note
RFID Device
Frequency Range
0.13420000 - 0.13420000
Company
Nedap N. V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instruction Manual VP1006-B Safety Instructions 5287774 / Version 01.001 / April 2020 / EN Original instructions Livestock Management Copyright Copyright © Nedap N.V. All rights reserved. The information in this document is subject to change without notice, it is not to be reproduced in any way, in whole or in part, without the written consent of Nedap N.V. All trademarks referenced belong to their respective owners. Disclaimer Nedap N.V. has made every effort to ensure the accuracy of the information contained in this document. However, Nedap N.V. makes no representations or warranties whatsoever whether express or implied as to the accuracy, correctness, completeness or fit-for-purpose or suitability for the purpose of this product. You use the products at your own risk. Nedap N.V. excludes any liability to the maximum extent permitted by applicable law for the damages caused by errors or failures made during the installation or improper use of this product or by not applying the instructions stated in this document. Nedap N.V. reserves the right to make improvements or amendments to this document and/or the products described therein at any time without any notification. The latest version of this document can be found on the Nedap Livestock Management business portal (www.nedap.com/livestockmanagement-portal). Please download the latest version of this document (by yourself or reseller) and keep a copy for your own records. This document can be published in various languages but only the English language version will prevail. Nedap N.V. assumes no responsibility for any errors caused for the translations into another language. Warranty and spare parts Please consult the Nedap products dealer from whom you purchased this product, in regards to the applicable warranty conditions. This product cannot be used for any other purpose as described in this document. If the product is not installed according to this document; the warranty provided is not applicable. At the sole discretion of Nedap N.V., Nedap N.V. may decide to change the conditions of the warranty policy. You agree that Nedap N.V. is able to compensate you the pro-rata value of the warranty involved rather than replacing or repairing the product depending on the technical or economical value of the product. Prior to applying the warranty, please verify if you comply with the warranty conditions of the warranty policy, whether you can successfully apply for the replacement or repair of a defective part. Parts can only be replaced with original Nedap parts, otherwise the warranty policy will not be applicable on the product. If the warranty is applicable, please contact the dealer or send the defective parts to the dealer. Additional information For any information or questions regarding the product, please contact your own dealer. VP1006-B / Safety Instructions 5287774 / Version 01.001 / April 2020 / EN 1 Livestock Management VP1006-B VP1006-B / Safety Instructions 5287774 / Version 01.001 / April 2020 / EN 2 Livestock Management Content 1Safety .................................................................................................. 3 2Compliance .......................................................................................... 5 VP1006-B / Safety Instructions 5287774 / Version 01.001 / April 2020 / EN 3 Livestock Management 1 Safety Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual may result in serious injury or death. Keep this manual in a safe location for future reference. Symbols used in the manual Danger Indicates a hazardous situation that, if not avoided, will result in death or serious injury. Warning Indicates a hazardous situation that, if not avoided, could result in death or serious injury. Caution Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. Indicates important information but not hazard related. Suggestions and advice to perform certain tasks more easily. General safety instructions Warning Always turn off the mains power supply when working on the electrical installation. Warning Always wear proper protection when installing and maintaining the VP1006-B. Caution Use the VP1006-B only with a suitable power supply. The power supply or power adapter must comply with local regulations for a SELV, limited power (NEC class2, ps2) output (e.g. Nedap VP2001-B or Nedap power adapter (P/N 9223126)). Caution Installation and service should only be done by locally qualified personnel. Caution Install the system according to the local rules and regulations. Working environment Caution The installation area must be free from any obstacles, including animals. VP1006-B / Safety Instructions 5287774 / Version 01.001 / April 2020 / EN 4 Livestock Management Caution Make sure all components are installed out of reach of animals. Caution Make sure all cables are properly concealed, and form no danger for stumbling. Caution Take into account the high concentrations of ammonia when installing and maintaining the VP1006-B in pig barns. Animal welfare and safety The automated actions of the Nedap Livestock Management systems do never discharge the installer and the user of the system from his/her responsibility to assure and to take care of the well-being of the animals. VP1006-B / Safety Instructions 5287774 / Version 01.001 / April 2020 / EN 5 Livestock Management 2 Compliance FCC and ISED Compliance statement This device complies with part 15 of the FCC Rules and with RSS-210 of Innovation, Science and Economic Development Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Cet…

Text truncated - open the document above for the full version.

Users Manual

TÜV Rheinland Nederland B.V. Eiberkamp 10 9351VT Leek The Netherlands . ® TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval. To whom it may concern, On behalf of our customer Nedap N.V., we hereby declare the antenna of the following device: FCC ID: CGDVP1006B IC: 1444A-VP1006B Manufacturer: Nedap N.V. Brand: Nedap Model: VP1006B The VP1006B may be used with the following magnetic loop antennas: Single Loop Walk Through, Single Loop Walk Over, VP6011, VP6012, VP6030, VP6040, VP6041, VP6042 and VP6050. All branded Nedap. Antenna dimensions (cm) Antenna Single Loop Walk Through 100 by 195-210 Antenna Single Loop Walk Over 80 by 120 Antenna VP6011 24 by 12,5 Antenna VP6012 24 by 12,5 Antenna for VP6030 28 by 39 Antenna VP6040 2 times 64,6 x 30,3 and 64,6 by 59,2 Antenna VP6041 2 times 47,6 by 38,8 Antenna VP6042 2 times 47,6 by 38,8 Antenna VP6050 47,6 by 117,6 Antenna VP6041 and VP6042 are identical. However, model VP6041 is adjusted for environments with lots of steel for short distances. The VP6042 is adjusted for longer distances (1 m) recognition. Best regards, TÜV Rheinland Nederland B.V. R. van der Meer Test Engineer

Attestation Statements

Trade register: 08013836 | IBAN: NL08 ABNA 0453299555 | BIC: ANBNANL2A | VAT: NL006456285B01 The General Terms and Conditions of ICT-Office apply to all our offers and agreements. These conditions can be found at our website and can be provided upon request. July 26, 2019 Authority to Act as Agent TUV Rheinland of North America, Inc. 1279 Quarry Ln., Ste. A Pleasanton, CA 94566 To Whom It May Concern: I appoint Richard van der Meer of TÜV Rheinland Nederland B.V. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TÜV Rheinland Group, still resides with Nedap N.V. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: August 01, 2020 By: __________________________ __Reinold Hubers_________ (Signature) (Print name) Title: _Compliance Manager________ Telephone:__+31 5440471111________________________ On behalf of: _ _Nedap N.V.___________ Nedap N.V. Parallelweg 2 7141 DC Groenlo The Netherlands T: +31 (0)544 471 111 [email protected] www.nedap.com

Cover Letter(s)

Trade register: 08013836 | IBAN: NL08 ABNA 0453299555 | BIC: ANBNANL2A | VAT: NL006456285B01 The General Terms and Conditions of ICT-Office apply to all our offers and agreements. These conditions can be found at our website and can be provided upon request. April 1, 2020 Subject: Confidentiality Request for FCC ID: _CGDVP1001B and IC: 1444A-VP1001B And FCC ID: _CGDVP1006B and IC: 1444A-VP1006B Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Nedap N. V. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: __________________________ _Reinold Hubers____ (Signature/Title) (Print name) Compliance Manager Nedap N.V. Parallelweg 2 7141 DC Groenlo The Netherlands T: +31 (0)544 471 111 [email protected] www.nedap.com

External Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. Eiberkamp 10 9351VT Leek The Netherlands Telephone: +31 888887888 Internet: www.tuv.com/nl E-mail: [email protected] Project number: 19022705.p02 Page 1 of 8 PHOTOGRAPHS OF THE EXTERIOR OF A BRAND NEDAP, MODEL VP1006B Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 2 of 8 Table of contents 1 PHOTOGRAPHS OF THE EQUIPMENT. ............................................................................................................. 3 1.1 EXTERNAL VIEW. ............................................................................................................................................... 3 1.1.1 Top view. ................................................................................................................................................. 3 1.1.2 Bottom view. ............................................................................................................................................ 4 1.1.3 Front view. ............................................................................................................................................... 5 1.1.4 Rear view ................................................................................................................................................ 6 1.2 SIDE VIEWS ...................................................................................................................................................... 7 Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 3 of 8 1 Photographs of the equipment. 1.1 External view. 1.1.1 Top view. Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 4 of 8 1.1.2 Bottom view. Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 5 of 8 1.1.3 Front view. Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 6 of 8 1.1.4 Rear view Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 7 of 8 1.2 Side views Left side view Brand mark: Model: Nedap VP1006B Project number: 19052705.p02 Page 8 of 8 Right side view END OF REPORT

ID Label/Location Info

Label info Warning/statement label Location , see next page Product as positioned on back side of the device Location of warninglabel on device

Internal Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. Eiberkamp 10 9351VT Leek The Netherlands Telephone: +31888887888 Internet: www.tuv.com/nl E-mail: [email protected] Project number: 19022705.p01 Page 1 of 8 PHOTOGRAPHS OF THE INTERIOR OF A BRAND NEDAP, MODEL VP1006B Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 2 of 8 Table of contents 1.1 INTERNAL VIEW 1, TOP COVER REMOVED. ........................................................................................................... 3 1.2 INTERNAL VIEW 2, CONTROL/DISPLAY PCB ASSEMBLY AS LIFTED FROM THE UNIT ................................................ 4 1.3 INTERNAL VIEW 2, EMPTY CASE .......................................................................................................................... 5 .................................................................................................................................................................................. 5 2 INNER ASSEMBLY, PCB VIEW .......................................................................................................................... 6 2.1 MAIN PCB VIEW, COMPONENT SIDE. .................................................................................................................. 6 2.2 MAIN PCB VIEW, BACK SIDE .............................................................................................................................. 7 2.1 PCB VIEW – ASSY 7845235 – RF PCB .............................................................................................................. 8 Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 3 of 8 1.1 Internal view 1, top cover removed. Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 4 of 8 1.2 Internal view 2, Control/Display PCB assembly as lifted from the unit Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 5 of 8 1.3 Internal view 2, empty case Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 6 of 8 2 Inner assembly, PCB view 2.1 Main PCB view, component side. Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 7 of 8 2.2 Main PCB view, back side Brand mark: Model: Nedap VP1006B Project number: 19022705.p01 Page 8 of 8 2.1 PCB view – Assy 7845235 – RF pcb END OF REPORT

Test Report

PrÏ‹fberich - Produkte Test Report - Products Prüfbericht-Nr.: Test Report No.: 19022705C.r02 Auftrags-Nr.: Order No.: 89003402 Seite 1 von 29 Page 1 of 29 Kunden-Referenz-Nr.: Client Reference No.: 1541649 Auftragsdatum: Order date: 2020-03-13 Auftraggeber: Client: Nedap N.V., Parallelweg 2 7141 DC Groenlo, Netherlands, A. Haytema Prüfgegenstand: Test item: 134.2 kHz Inductive RFID Card Reader / Motor controller Bezeichnung / Typ-Nr.: Identification / Type No.: VP1006B in combination with VP6012 antenna and Single Loop Walk Through antenna Auftrags-Inhalt: Order content: Compliance with regulatory requirements Prüfgrundlage: Test specification: 47 CFR PART 15 (10-1-19 EDITION), Subpart 15C RSS-Gen (Issue 5 April 2018) General Requirements for Compliance of Radio Apparatus and RSS-210 (Issue 10 Dec 2019) Licence-exempt Radio Apparatus - Wareneingangsdatum: Date of receipt: 2020-03-16 Prüfmuster-Nr.: Test sample No.: - Prüfzeitraum: Testing period: 2020-03-20 / 2020-04-02 Ort der Prüfung: Place of testing: Leek Prüflaboratorium: Testing laboratory: TÜV Rheinland Nederland B.V. Leek Laboratory Prüfergebnis*: Test result*: Pass TÜV Rheinland Nederland B.V. . Eiberkamp 10 . 9351 VT Leek . Tel: + 31 88 8887888 Mail: [email protected] . Web: www.tuv.com geprüft von / tested by: genehmigt von / reviewed & authorized by: Datum /date: 2020-04-17 Richard van der Meer, Expert 2020-04-17 Erik van der Wal, Expert Datum Date Name / Stellung Name / Position Unterschrift Signature Datum Date Name / Stellung Name / Position Unterschrift Signature Sonstiges / Other: issue date is equal to authorized date Zustand des Prüfgegenstandes be Anlieferung: 2 Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: Legend: 1 = sehr gut P(ass) = entspricht o.g. 1 = very good P(ass) = passed a.m. 2 = gut Prüfgrundlage(n) 2 = good Test specification(s) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 3 = satisfactory F(ail) a.m. test specification(s) 4 = ausreichend N/A = nicht anwendbar 4 = sufficient N/A = not applicable 5 = mangelhaft N/T/ = nicht getested 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwending eines Prüfzeichens. This test report only relates to the above mentioned testsample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This report does not entitle to carry any test mark V04 PrÏ‹fbericht - Produkte Test Report - Products Test Report No.: 19022705C.r02 Page 2 of 29 TEST SUMMARY Test Specification Clause Test Case Pass Fail Not applicable Not performed §15.209 / RSS-Gen Table 5 Radiated Emissions §15.207 / RSS-Gen Table 4 AC Power Line Conducted Emissions Revisions Revisions Revision Revision Datum Date Anmerkung Remark Verfasser Author - 2020.04.17 First release R. van der Meer Note: Latest revision report will replace all previous reports PrÏ‹fbericht - Produkte Test Report - Products Test Report No.: 19022705C.r02 Page 3 of 29 Contents 1. GENERAL REMARKS ............................................................................................... 4 1.1.1 Complementary Materials ............................................................................................................ 4 1.1.2 Special Accessories ..................................................................................................................... 4 1.1.3 Equipment modifications .............................................................................................................. 4 2. TEST SITES ............................................................................................................ 5 2.1 TEST FACILITIES ..................................................................................................... 5 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS TABLE 1: LIST OF TEST AND MEASUREMENT EQUIPMENT ..................................................................................... 6 2.3 MEASUREMENT UNCERTAINTY ................................................................................. 7 3. GENERAL PRODUCT INFORMATION ........................................................................... 8 3.1 COUNTERMEASURES TO ACHIEVE COMPLIANCE ......................................................... 8 3.2 OPERATION MODES ................................................................................................ 8 3.3 PHYSICAL CONFIGURATION FOR TESTING ................................................................. 9 3.4 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................... 11 4. TEST RESULTS ..................................................................................................... 12 4.1.1 20dB and 99% Bandwidth .......................................................................................................... 12 4.1.2 Radiated Emissions of Transmitter ............................................................................................ 16 4.1.3 Radiated field strength measurements H-field, 0.009-30 MHz. ..................................................... 18 Test equipment used (for reference see test equipment listing). ............................................................ 18 2 AC POWER LINE CONDUCTED MEASUREMENTS ...................................................... 23 2.1.1 AC Power Line Conducted Emission of Transmitter .................................................................. 24 Plots of the AC Power-line Conducted Emissions .................................................................................. 25 PrÏ‹fbericht - Produkte Test Report - Products Test Report No.: 19022705C.r02 Page 4 of 29 1. General Remarks 1.1.1 Complementary Materials There is no attachment to this test report. 1.1.2 Special A…

Text truncated - open the document above for the full version.

Test Setup Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. P.O. Box 37 9350 AA Leek (NL) Eiberkamp 10 9351 VT Leek (NL) Telephone: +31 8888887888 Internet: www.tuv.com E-mail: [email protected] Project number: 19022705.fcc02b Page 1 of 11 PHOTOGRAPHS OF THE TESTSETUP OF A BRAND NEDAP, MODEL VP1006B Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 2 of 11 Table of contents 1 PHOTOGRAPHS OF THE TEST SETUP. ...................................................................................................................... 3 1.1 RADIATED EMISSIONS. ................................................................................................................................................... 3 1.1.1 Radiated emissions, H-field 0.009 MHz – 30 MHz ......................................................................................... 3 1.1.2 Radiated emissions, E-field 30 MHz – 1000 MHz .......................................................................................... 9 2 AC POWER LINE CONDUCTED EMISSIONS ............................................................................................................ 10 2.1.1 AC power line conducted emissions test setup, EUT with VP6012 antenna ............................................ 10 2.1.2 AC power line conducted emissions test setup, EUT with Single Walk Through antenna ..................... 11 Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 3 of 11 1 Photographs of the test setup. 1.1 Radiated Emissions. 1.1.1 Radiated emissions, H-field 0.009 MHz – 30 MHz Setup EUT with VP6012 antenna @3m Setup EUT with VP6012 antenna @5m Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 4 of 11 Setup EUT with VP6012 antenna @10m Setup in Semi -AR @3m Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 5 of 11 Setup EUT with Single Walk Through antenna, @3m (X-orientation) Setup EUT with Single Walk Through antenna, @3m (Y-orientation) Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 6 of 11 Setup EUT with Single Walk Through antenna, @3m (Z-orientation) Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 7 of 11 Setup EUT with Single Walk Through antenna, @5m Setup EUT with Single Walk Through antenna, @10m Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 8 of 11 Setup in Semi -AR @3m Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 9 of 11 1.1.2 Radiated emissions, E-field 30 MHz – 1000 MHz Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 10 of 11 2 AC Power Line Conducted Emissions 2.1.1 AC power line conducted emissions test setup, EUT with VP6012 antenna Brand mark: Model: Nedap VP1006B Project number: 19022705.fcc02b Page 11 of 11 2.1.2 AC power line conducted emissions test setup, EUT with Single Walk Through antenna END OF REPORT

Contact Information

Applicant

Reinold Hubers(Approbation Officer)
[email protected]0031544471111Fax: 0031544463475

Technical Contact

Nedap N.V.Reinold Hubers
[email protected]0031544471111

Parallelweg 2 · Groenlo · Netherlands

Test Firm

TUV Rheinland Nederland B.V.Wiebe Boekema
[email protected]31-088-888-7888Fax: 31-653-162-192

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1342 MHz - 0.1342 MHz-
Confidentiality
Long Term

Other Applications from Nedap N. V.

VP1004-B System - FCC ID CGDVP1004B - Nedap N. V.
CGDVP1004B

VP1004-B System

Jan 25, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
SMARTTAG EAR - FCC ID CGDFERPH - Nedap N. V.
CGDFERPH

SMARTTAG EAR

Dec 15, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Reader for 120 kHz and 13.56 MHz cards and also NFC, QR and BT - FCC ID CGDNVR2001 - Nedap N. V.
CGDNVR2001

Reader for 120 kHz and 13.56 MHz cards and also NFC, QR and BT

Dec 01, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Long-range vehicle and driver identification tag - FCC ID CGDBOOSTER11 - Nedap N. V.
CGDBOOSTER11

Long-range vehicle and driver identification tag

Nov 30, 2020

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
4kW Electronic Lamp Driver - FCC ID CGDLD4KW - Nedap N. V.
CGDLD4KW

4kW Electronic Lamp Driver

Jul 15, 2020

Equipment Class

DTS - Digital Transmission System