Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02-050 / / / Exhibit - H 1 of 1 USERβS MANUAL FOR CD-RW/DVD-ROM DRIVE MODEL SD-R1312
Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02-050 / / / Exhibit - A 1 of 1 CD-RW/DVD-ROM DRIVE MODEL SD-R1312 BLOCK DIAGRAM
Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02-050 / / / Exhibit - B 1 of 3 PHOTO OF CD-RW/DVD-ROM DRIVE MODEL SD-R1312 Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02-050 / / / Exhibit - B 2 of 3 PHOTO OF CD-RW/DVD-ROM DRIVE MODEL SD-R1312 Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02-050 / / / Exhibit - B 3 of 3 PHOTO OF CD-RW/DVD-ROM DRIVE MODEL SD-R1312
Toshiba Corporation Application No. YFA-R3381 FCC ID: CJ6AT02 -050 / / / Exhibit - C 1 of 1 ID Label / Location Info: 1. FCC statements & FCC ID number are indicated on the rating label. Word; This device complies with Part 15 of the FCC Rules. Operation is Subject to the following two conditions : (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID : CJ6AT02-050 / / / 2. Location of FCC label Front 3. Sketch of rating label
FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 29 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341 Japan TEL 81-478-82-0963 FAX 81-478-82-3373 THE PHOTOS OF TEST-SETUPS Conducted emission 150/450kHz - 30MHz (Mains ports) FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 30 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341 Japan TEL 81-478-82-0963 FAX 81-478-82-3373 THE PHOTOS OF TEST-SETUPS Radiated emission 30MHz - 1000/2000MHz
DIRECTORY Page A) Documentation noneConstructional dataform (CDF) 18Summary 15 - 17Test result 13 - 14Test configuration 12Equipment under test 6 - 11Test conditions 5Measurement uncertainty and Symbols definitions Test methods, Environmental conditions, Power supply system utilized, 4Test facilities 3Test regulations 2Directory B) Test data N/AVoltage fluctuations and flicker N/AHarmonic currents N/A1GHz - 18GHzEquivalent radiated emissions N/A30MHz - 300MHzInterference power 24 - 2830MHz - 1000/2000MHzRadiated emissions N/A150kHz - 30MHzRadiated emissions N/A150kHz - 30MHzConducted emissions (Telecommunication) 19 - 23150/450kHz - 30MHzConducted emissions (Mains) C) Appendix 29 - 30The photos of test-setups N/A : Not Applicable FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 2 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341Japan TEL 81-478-82-0963 FAX 81-478-82-3373 TEST REGULATIONS The tests were performed according to following regulations : o - EN 61000-6-3 :2001 o - EN 61000-6-4 :2001 o - EN 55011:1998o - Group 1o - Group 2 o - EN 55011:1998 / A1:1999o - Class Ao - Class B o - EN 55014-1:2000o - Household appliances and similar o - EN 55014-1:2000 / A1:2001o - Tools o - Semiconductor devices o - EN 55022:1994 / A2:1997 o - EN 55022:1998 o - Class Ao - Class B o - EN 60601-1-2 :1993 o - EN 60601-1-2 :2001 o - EN 61326:1997 / A2:2001o - Class Ao - Class B o - EN 61000-3-2 :1995 / A2:1998o - Class Ao - Class B o - EN 61000-3-2 :2000o - Class Co - Class D - Harmonic current emission o - EN 61000-3-3 :1995 - Voltage fluctuations and flicker o - EN 61000-3-3 :1995 / A1:2001 -------------------------------------------------------------------------------------------------------------------- - FCC Part 15 Subpart Bo - Class A - Class B Test Method : ANSI C63.4-1992 o - FCC Part 15 Subpart Bo - Class Ao - Class B Test Method : ANSI C63.4-1992 according to 15.109(g) : CISPR 22 o - FCC Part 18 Subpart C Test Method : FCC/OST MP-5 (1985) -------------------------------------------------------------------------------------------------------------------- o - ICES-003:1997o - Class Ao - Class B Test Method : C108.8-M1983 -------------------------------------------------------------------------------------------------------------------- o - AS/NZS 2064 :1997 / A1:1997o - Group 1o - Group 2 o - Class Ao - Class B o - AS/NZS 1044 :1995 / A1:1997o - Household appliances and similar o - Tools o - Semiconductor devices o - AS/NZS 3548 :1995 / A2:1997o - Class Ao - Class B -------------------------------------------------------------------------------------------------------------------- o - VCCIo - Class Ao - Class B -------------------------------------------------------------------------------------------------------------------- o - CISPR 11:1997o - Group 1o - Group 2 o - CISPR 11:1997 / A1:1999o - Class Ao - Class B o - CISPR 14-1:2000o - Household appliances and similar o - CISPR 14-1:2000 / A1:2001o - Tools o - Semiconductor devices o - CISPR 22:1993 / A2:1996 o - CISPR 22:1997 o - Class Ao - Class B FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 3 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341Japan TEL 81-478-82-0963 FAX 81-478-82-3373 TEST FACILITIES All measurement facilities are located in 1614, Mushihata, Omigawa-machi, Katori-gun, Chiba-ken, 289-0341 Japan. Accredited by American Association for Laboratory Accreditation(A2LA) for the emission and immunity tests stated in the scope of the certificate under Certificate Number 1266-01. Authorized by NEMKO for the emission and immunity tests stated in the scope of the authorization under Authorization Number ELA172. Approved by the Ministry of Commerce in New Zealand under ENG 3/9 AJD. Recognized by TUV Product Service for the emission and immunity tests stated in the scope of the certificate under Certificate No. JPN9803C. Registered by Federal Communications Commission under the registered numbers 90558 for No. 1 test site, 510504 for No. 2 test site, 90557 for No. 4 test site and 99356 for No. 5 test site. Registered by Voluntary Control Council For Interference by Information Technology Equipment(VCCI) under Registered Numbers R-188 and C-785 for No. 1 open site, C-187 for No. 1 shielded room, R-189 for No. 2 open site, C-188 for No. 2 shielded room, R-656 for No. 4 open site, C-613 for No. 4 shielded room, R-1227 and C-1290 for No.5 open site, and C-1291 for No.5 shielded room. FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 4 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341Japan TEL 81-478-82-0963 FAX 81-478-82-3373 TEST METHODS The test methods are implemented subject to the internal test procedures based on the regulations indicated with " " on the page 3. ENVIRONMENTAL CONDITIONS Temperature --- see test data Humidity --- % see test data Atmospheric pressure --- hPasee test data POWER SUPPLY SYSTEM UTILIZED Power supply system : DC+5V, +12V AC120V/60Hz for PC MEASUREMENT UNCERTAINTY The treatment of the measurement uncertainty shall be based on "Guide to the expression of Uncertainty in Measurement" (GUM). The uncertainty of measurement result is Conducted Emission Test: 1.76dB Radiated Emission Test: 3.73dB for a level of confidence of approximately 95%, (k=2). DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT - Black box indicates that the listed condition, standard or equipment is applicable for this Report. o - Blank box indicated that the listed condition, standard or equipment was not applicable for this Report. FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 5 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341Japan TEL 81-47β¦
Text truncated - open the document above for the full version.
FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 29 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341 Japan TEL 81-478-82-0963 FAX 81-478-82-3373 THE PHOTOS OF TEST-SETUPS Conducted emission 150/450kHz - 30MHz (Mains ports) FCC ID : CJ6AT02-050 Rev. 5.2 Model: SD-R1312, Final tested date: September 13, 2002, File No. TR1-02837F page 30 of 30 EMC Kashima Corporation 1614,Mushihata,Omigawa-machi,Katori-gun,Chiba-ken,289-0341 Japan TEL 81-478-82-0963 FAX 81-478-82-3373 THE PHOTOS OF TEST-SETUPS Radiated emission 30MHz - 1000/2000MHz
9470 Irvine Boulevard Β· Irvine, California Β· United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

dynabook Wireless Optical Silent Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Notebook Computer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
dynadock WiAC
Equipment Class
NII - Unlicensed National Information Infrastructure TX
TransferJet USB Adapter
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
TransferJet MicroUSB Adapter
Equipment Class
UWB - Ultra Wideband Transmitter