COFNFABACMR02802.11ac/a/b/g/n + BT Wireless Module

Universal Global Scientific Industrial Co., Ltd.
802.11ac/a/b/g/n + BT Wireless Module - FCC ID COFNFABACMR02 - Universal Global Scientific Industrial Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 25, 2014
Application Purpose
Original Equipment
Date of Application
Feb 25, 2014
Equipment Note
802.11ac/a/b/g/n + BT Wireless Module
Frequency Range
5745.00000000 - 5825.00000000
Company
Universal Global Scientific Industrial Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Product Business Unit/ Research & Development Division The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. User Guide of NFA-BAC-MR-02 SOURCE ORGANIZATION: USI WP/ RD/ HW Prepared by Terry Hua Date: 2014/02/05 Checked by Date: Approved by Date: Concurrence Date: Document No. Rev. 1.0 Product No. Product Code Model No. NFA-BAC-MR-02 Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2014/02/05 Page 2 Description EVB User Guide of NFA-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. Change Sheet Rev. Date Description of change Approval & Date Page Par Change(s) 1.0 2014/02/05 All All Initial Version Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2014/02/05 Page 3 Description EVB User Guide of NFA-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. Table of Contents 1. Introduction ................................................................................ 4 2. Testing Environment Setup....................................................... 4 3. TX Command for Measurement ................................................ 5 4. RX Command for Measurement................................................ 6 Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2014/02/05 Page 4 Description EVB User Guide of NFA-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. 1. Introduction This EVB is an interface transfer card for NFA-BAC-MR-02 NGFF Card. The NGFF card is built in 802.11 a/b/g/n/ac and Bluetooth function. The EVB will transfer NGFF interface to PCI express card interface for inserting the Testing PC 2. Testing Environment Setup Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2013/12/04 Page 5 Description EVB User Guide of NFB-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. 3. TX Command for Measurement Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2013/12/04 Page 6 Description EVB User Guide of NFB-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. 4. RX Command for Measurement Universal Global Scientific Industrial Co., Ltd. Doc No. Rev 1.0 Document released by WP/ RD/ HW Date. 2013/12/04 Page 7 Description EVB User Guide of NFB-BAC-MR-02 The content of this document is to be treated as strictly confidential and is not to be disclosed, reproduced or used, except as authorized in writing by Universal Global Scientific Industrial Co., Ltd. Copyright © 2010 Universal Global Scientific Industrial Co., Ltd. Industry Canada statement This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. This device is intended only for OEM integrators under the following conditions: (For module device use) 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes: (Pour utilisation de dispositif module) 1) L'antenne doit être installée de telle sorte qu'une distance de 20 cm est respectée entre l'antenne et les utilisateurs, et 2…

Text truncated - open the document above for the full version.

Attestation Statements

1 141La351 Sec.1TaipingRoadaotuNantTaiwan Tel:+886-49-235-0876http:/ .usi.com.tw DFSclientdevicechannelplanand softwareoperationaldeclaration Date:2014-02-12 We UNIVERSALGLOBALSCIENTIFICINDUSTRIALCO. LTD.declarethat the deviceFCCID: COFNFABACMR02ModelName:NFA-BAC-MR-02 doesnot haveAd Hoc on non-USfrequencies"and/oron DFSfrequencies.Also the clientsoftwareand associateddriverswill not initiateany transmission on DFSfrequencieswithoutinitiationby a master.Thisincludesrestrictionon transmissionsfor beaconsand supportfor ad-hocpeer-topeermodes. Belowis the channel/frequencyplanfor the device Active 384042 44' 48 52 5190 5200521052205240 5260 ActiveActiveActiveActiveActivePassive C ~quencyHz) ~.10i ScanTypePassivePassive CH 10 102104 uemcyj 55005510 5520 ~g§ Type Essivei assivePassive Gtl AIon DFSchannelsthe WLANdriverin the deviceoperatesunderthe controlof an AP at all timesexceptwhenin ad-hocmodeon US non-DFSchannels The devicepassivelyscansDFSfrequenciesuntila masterdeviceis detected.The controlof this functionalityis not accessibleto anyoneunderany conditions Furthermothe firmwareis protectedby specialsignatureand CRCchecksum.Signatureand CRCchecksumwill be calculatedand verifiedbeforefirmware upgrade.Unauthorizedmodificationto firmwarewill leadthe failureof verificationthusfirmwareupgradeis not allowed. Sincerelyyours Signature d MartinShih AssociateManager UNIVERSALGLOBALSCIENTIFICINDUSTRIALCO. LTD TE 886 9-2350876#26129 FAX:886-49-2332061

Cover Letter(s)

UniversalGlobalScientificIn 141Lane351Sec.1TaipingRoadTsaotuenNantouTaiwan Tel:+8869-235876httpvww.usLcom.tw FederalCommunicationsCommission AuthorizationandEvaluationDivision Date:February122014 ConfidentialitvReauest FCC10:COFNFABACMR02 PursuanttoSections0 57and059ofthecommission'sruleswerequestshort-term confidentialtreatmentforthefollowinginformationuntilMarch282014inordertoensuresensitive businessinformationremainsconfidentialuntiltheactualmarketingofthedevice: ExternalPhotos TestSetupPhotos User'sManual InternalPhoto Thankyou! Sincerelyyours --4adkJi-- MartinShih AssociateManager UNIVERSALGLOBALSCIENTIFICINDUSTRIALCO.LTD. TE886-49-2350876#26129 FAX:886-49-2332061 E-mail:[email protected]

Cover Letter(s)

m 141Lane351 Sec.1TaipingRoadtuen NantouTaiwan Tel:+8869-235-0876http:/ .usi.com.tw Date:2014/1/29 FCC10: COFNFABACMR02 FederalCommunicationsCommission Authorizationand EvaluationDivision ConfidentialitvReauest Pursuantto Sections057 and 059 of the Commission'sRulesthe Applicantherebyrequests confidentialtreatmentof informationaccompanyingthis Applicationas outlinedbelow: Schematics BlockDiagram The abovematerialscontaintradesecretsand proprietaryinformationnot customarilyreleasedto the public.The publicdisclosureof thesemattersmightbe harmfulto the Applicantand provide unjustifiedbenefitsto its competitors. The Applicantunderstandsthat pursuantto Rule057disclosureof this Applicationand all accompanyingdocumentationwill not be madebeforethe dateof the Grantfor this application. Sincerelyyours Mavr~ Sh MartinShih AssociateManager UNIVERSALGLOBALSCIENTIFICINDUSTRIALCO..LTD. TEL:886-49-2350876#26129 FAX:686-49-2332061 E-mail:[email protected]

Cover Letter(s)

l 141Lane351Sec.1ipingRoadTsaoluenNanlouTaiwan Tel:+88.6-49-235-0876hUp:llwww.usi.com.lw AGENCYAUTHORIZATIONLETTER Date:2014/1/29 Towhomit mayconcern: WetheundersignedUNIVERSALGLOBALSCIENTIFICINDUSTRIALCO.LTD.hereby authorizeBureauVeritasConsumerProductsServices(H.K)d. TaoyuanBranch.ofTaiwanto actonourbehalfinallmattersrelatingtoallprocessesrequiredintheFCCPart15Capproval andanycommunicationneededwiththenationalauthority.Anyandallactscarriedoutby BureauVeritasConsumerProductsServices(H.K)d. TaoyuanBranch.onourbehalfshall havethesameeffectsasactsofourown. If youhaveanyquestionsregardingtheauthorizationpleasedon'thesitatetocontactus. Thankyou! Sincerelyyours Signature:7' ~ MartinShih AssociateManager UNIVERSALGLOBALSCIENTIFICINDUSTRIALCO..LTD. TE886-49-2350876#26129 FAX:886-49-2332061 E-mail:[email protected]

Cover Letter(s)

FCC ID: COFNFABACMR02 Report No.: RF140123E01 Modular Approval Request Letter Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch February 24, 2014 Dear Application Examiner, UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD., It’s a 802.11ac/a/b/g/n + BT Wireless Module, FCC ID: COFNFABACMR02 would like to have your authorization as a modular approval specific to the mobile RF exposure condition. The requirements of section 15.212 of FCC rules have been met and shown on the following statements. 1. “The modular transmitter must have its own RF shielding.” The radio portion of this module has been shielded, please see exhibition External Photo. 2. “The modular transmitter must have buffered modulation/data inputs.” The EUT has buffered data inputs, it is integrated in chip Marvell 8897 QFN. 3. “The modular transmitterS must have its own power supply regulation.” The part number of this regulator is Marvell 8897 QFN. 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(C).” The EUT meets the FCC antenna requirements. The spurious emission, unique antenna connector and photo of antennas are shown in the test report. 5. “The modular transmitter must be tested in a stand-alone configuration” The EUT was tested in a stand-alone configuration via a extender. Please see section Photographs of Test Configuration in the test report, the EUT was plugged in this extender. 6. “The modular transmitter must be labeled with its own FCC ID number.” Please see exhibition Label Sample for the FCC ID of this module. And also in the exhibition Users Manual, there are instructions give to the OEM on how to label the end product. 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements.” The EUT is compliant with all applicable FCC rules. Detail instructions for maintaining compliance are given in the Users Manual. 8. “The modular transmitter must comply with any applicable RF exposure requirements.” The EUT is compliant with all applicable RF exposure requirements. RF Exposure is addressed in the RF exposure exhibition. Please contact me if you have any further questions. Thanks for your attention. Best Regards, signature Hank Chung / Assistant Manager Bureau Veritas Consumer Products Services (H.K.) Ltd., Hsinchu Branch

External Photos

Report No.: 140123E01 Page 1 CONSTRUCTION PHOTOS OF EUT Report No.: 140123E01 Page 2 Report No.: 140123E01 Page 3 Report No.: 140123E01 Page 4

ID Label/Location Info

(Fig. 1) FCC ID: COFNFABACMR02 FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. Label 2 3 4 5 1 1 2 3 4 5 A B C D E F G H A B C D E F G H DESCRIPTION A9 NO A2 A3 A4 A7 A6 A5 A8 UNIT: Shang/PE/MD SOURCE ORGANIZATION Universal Scientific Industrial Co.,Ltd. USI R DATE Unless otherwise tolerence specified ± label for NFA-BAC-MR-02 MODEL NO TITLE DESIGNER APP BY DATE DATE USI P/N SCALE: 1/1 DWG NO REV A1 mm 1 SHEET Star 1)空白标签料号: 2)label材质: Model: NFA-BAC-MR-02 FCC ID:COFNFABACMR02 IC:10293A-NFABACMR02 UG

Internal Photos

Report No.: 140123E01 Page 1 CONSTRUCTION PHOTOS OF EUT

Operational Description

FCC ID: COFNFABACMR02 Report No.: RF140123E01 Operational Description This device is a 802.11ac/a/b/g/n + BT Wireless Module, which operates in both of 2.4GHz and 5GHz bands; the maximum data rate could be up to 866.7Mbps which OFDM technique. If the signal to noise radio is too poor which could not support 866.7Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by DC 3.3V from host equipment. The antennas provided to the EUT, please refer to the following table: The other instruction, please have a look at the users manual. FCC 15.407(c) states: The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude the transmission of control or signaling information or the use of repetitive codes used by certain digital technologies to complete frame or burst intervals. Applicants shall include in their application for equipment authorization a description of how this requirement is met” Data transmission is always initiated by software, which is then pass down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets (ACKs, CTS, PSPoll, etc...) are initiated by the MAC. There are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets are being transmitted.

RF Exposure Info

Report No.: SA140123E01 1 of 11 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA140123E01 MODEL NO.: NFA-BAC-MR-02 FCC ID: COFNFABACMR02 RECEIVED: Jan. 23, 2014 TESTED: Feb. 07 to 11, 2014 ISSUED: Feb. 21, 2014 APPLICANT: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD. ADDRESS: 141, Lane 351, Sec. 1, Taiping Road., Tsaotuen, Nantou 54261, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: SA140123E01 2 of 11 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD .................................................................................... 3 1. CERTIFICATION ...................................................................................................... 4 2. RF EXPOSURE LIMIT .............................................................................................. 5 3. MPE CALCULATION FORMULA ............................................................................. 5 4. CLASSIFICATION .................................................................................................... 5 5. ANTENNA GAIN....................................................................................................... 6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ........................... 7 Report No.: SA140123E01 3 of 11 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA140123E01 Original release Feb. 21, 2014 Report No.: SA140123E01 4 of 11 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: 802.11ac/a/b/g/n + BT Wireless Module BRAND NAME: UG MODEL NO.: NFA-BAC-MR-02 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD. TESTED DATE: Feb. 07 to 11, 2014 STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: NFA-BAC-MR-02) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Feb. 21, 2014 ( Midoli Peng, Specialist ) APPROVED BY : , DATE: Feb. 21, 2014 ( May Chen, Manager ) Report No.: SA140123E01 5 of 11 Report Format Version 5.0.0 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA140123E01 6 of 11 Report Format Version 5.0.0 5. ANTENNA GAIN The antennas provided to the EUT, please refer to the following table: Transmitter Circuit Brand Model Antenna Gain(dBi) <Including cable loss> Frequency range (GHz to GHz) Antenna Type Connecter Type Cable Loss (dB) Cable Length (mm) Chain (0) Ant. 1 (WLAN Ant) High-Tek Electronics Co.,Ltd DC33001JB20 1.5 2.4~2.4835 PIFA i-pex(MHF) 0.65 260 0.68 2.77 2.72 5.15~5.35 5.47~5.75 5.75~5.85 PIFA i-pex(MHF) 1.02 1.07 1.09 260 Chain (1) Ant. 2 (WLAN+BT Ant) High-Tek Electronics Co.,Ltd DC33001JB30 -1.55 2.4~2.4835 PIFA i-pex(MHF) 0.98 390 1.57 2.77 1.70 5.15~5.35 5.47~5.7 5.75~5.85 PIFA i-pex(MHF) 1.53 1.6 1.64 390 Note: For 802. 11a/b/g mode: Max. antenna gain was chosen for final test. Report No.: SA140123E01 7 of 11 Report Format Version 5.0.0 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER For WLAN: 15.247(2.4GHz) 802.11b FREQUENCY (MHz) CONDUCTED POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2412 - 2462 98.401 1.5 20 0.02765 1.00 802.11g FREQUENCY (MHz) CONDUCTED POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2412 - 2462 470.977 1.5 20 0.13235 1.00 802.11n(HT20) FREQUENCY BAND (MHz) CONDUCTED…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF140123E01-2 1 of 26 Report Format Version 5.2.0 DFS TEST REPORT REPORT NO.: RF140123E01-2 MODEL NO.: NFA-BAC-MR-02 FCC ID: COFNFABACMR02 RECEIVED: Jan. 23, 2014 TESTED: Feb. 08, 2014 ISSUED: Feb. 21, 2014 APPLICANT: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD. ADDRESS: 141, Lane 351, Sec. 1, Taiping Road., Tsaotuen, Nantou 54261, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF140123E01-2 2 of 26 Report Format Version 5.2.0 Table of Contents RELEASE CONTROL RECORD ............................................................................. 3 1. CERTIFICATION ........................................................................................... 4 2. EUT INFORMATION ..................................................................................... 5 2.1 OPERATING FREQUENCY BANDS AND MODE OF EUT .......................... 5 2.2 EUT SOFTWARE AND FIRMWARE VERSION ............................................ 5 2.3 DESCRIPTION OF AVAILABLE ANTENNAS TO THE EUT.......................... 5 2.4 TRANSMIT POWER CONTROL (TPC) ........................................................ 8 2.5 STATEMENT OF MAUNFACTURER ............................................................ 8 3. U-NII DFS RULE REQUIREMENTS ............................................................. 9 3.1 WORKING MODES AND REQUIRED TEST ITEMS .................................... 9 3.2 TEST LIMITS AND RADAR SIGNAL PARAMETERS ................................. 10 4. TEST & SUPPORT EQUIPMENT LIST ...................................................... 13 4.1 TEST INSTRUMENTS ................................................................................ 13 4.2 DESCRIPTION OF SUPPORT UNITS ....................................................... 13 5. TEST PROCEDURE ................................................................................... 14 5.1 BVADT DFS MEASUREMENT SYSTEM: ................................................... 14 5.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL: .................... 15 5.3 DEVIATION FROM TEST STANDARD ....................................................... 16 5.4 CONDUCTED TEST SETUP CONFIGURATION ....................................... 16 5.4.1 CLIENT WITHOUT RADAR DETECTION MODE ....................................... 16 6. TEST RESULTS ......................................................................................... 17 6.1 SUMMARY OF TEST RESULTS ................................................................ 17 6.2 DETAILED TEST RESULTS ....................................................................... 18 6.2.1 TEST MODE: DEVICE OPERATING IN CLIENT WITHOUT RADAR DETECTION MODE. .................................................................................. 18 6.2.1.1 DFS DETECTION THRESHOLD ............................................................... 18 6.2.1.2 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME ...... 19 6.2.1.3 NON- OCCUPANCY PERIOD .................................................................... 20 6.2.1.4 NON-ASSOCIATED TEST ......................................................................... 22 6.2.1.5 NON- CO-CHANNEL TEST ....................................................................... 22 7. INFORMATION ON THE TESTING LABORATORIES ................................ 23 8. APPENDIX-A .............................................................................................. 24 9. APPENDIX B - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ...................................................... 26 Report No.: RF140123E01-2 3 of 26 Report Format Version 5.2.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF140123E01-2 Original release Feb. 21, 2014 Report No.: RF140123E01-2 4 of 26 Report Format Version 5.2.0 1. CERTIFICATION PRODUCT: 802.11ac/a/b/g/n + BT Wireless Module BRAND NAME : UG MODEL NO.: NFA-BAC-MR-02 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD. TESTED: Feb. 08, 2014 STANDARDS: FCC Part 15, Subpart E (Section 15.407) FCC 06-96 The above equipment (Model: NFA-BAC-MR-02) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and was in compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the m…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF140123E01-2 1 of 53 Report Format Version 5.0.0 FCC TEST REPORT (BLUETOOTH) REPORT NO.: RF140123E01-2 MODEL NO.: NFA-BAC-MR-02 FCC ID: COFNFABACMR02 RECEIVED: Jan. 23, 2014 TESTED: Feb. 07 to 12, 2014 ISSUED: Feb. 21, 2014 APPLICANT: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD. ADDRESS: 141, Lane 351, Sec. 1, Taiping Road., Tsaotuen, Nantou 54261, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, Taiwan, R.O.C. TEST LOCATION (2): No.49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF140123E01-2 2 of 53 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ........................................................................................................ 4 1 CERTIFICATION ................................................................................................................ 5 2 SUMMARY OF TEST RESULTS ......................................................................................... 6 2.1 ME ASUREMENT UNCERTAINTY ..................................................................................... 7 3 GENERAL INFORMATION ................................................................................................. 8 3.1 GENERAL DESCRIPTION OF EUT(BLUETOOTH) ............................................................ 8 3.2 DESCRIPTION OF TEST MODES ...................................................................................... 9 3.3 TEST MODE APPLICABLITY AND TESTED CHANNEL DETAIL: ......................................10 3.4 GENERAL DESCRIPTIO…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Martin Shih(Manager)
[email protected]886-49-235-0876Fax: 886-49-233-2061

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
315C5.75 GHz - 5.83 GHz299.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power listed is the maximum combined conducted output power. Single Modular Approval for mobile RF Exposure condition. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation in accordance with FCC multi-transmitter product guidelines. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter.

Other Applications from Universal Global Scientific Industrial Co., Ltd.

COF-WMCW51MS

802.11a/b/g/n/ac/ax 1x1 + BT 5.3 Combo Module

Feb 23, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
802.11a/b/g/n/ac 1x1 with BT 5.0 SiP Module - FCC ID COF-BM25-EXT - Universal Global Scientific Industrial Co., Ltd.
COF-BM25-EXT

802.11a/b/g/n/ac 1x1 with BT 5.0 SiP Module

Sep 09, 2024

Equipment Class

DTS - Digital Transmission System
802.11a/b/g/n/ac 2x2 MIMO + BT 5.1 Combo Module - FCC ID COF-WMBACAT49 - Universal Global Scientific Industrial Co., Ltd.
COF-WMBACAT49

802.11a/b/g/n/ac 2x2 MIMO + BT 5.1 Combo Module

Feb 24, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Azure Sphere Module - FCC ID COF-AS01 - Universal Global Scientific Industrial Co., Ltd.
COF-AS01

Azure Sphere Module

Jun 22, 2020

Equipment Class

DTS - Digital Transmission System
3G Module - FCC ID COF-UNA-A - Universal Global Scientific Industrial Co., Ltd.
COF-UNA-A

3G Module

May 19, 2015

Equipment Class

PCB - PCS Licensed Transmitter