FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sigma Designs Inc/
  3. D87-SG-UZB3503

D87-SG-UZB3503Z-Wave USB Adapter

Sigma Designs Inc
Z-Wave USB Adapter - FCC ID D87-SG-UZB3503 - Sigma Designs Inc
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 22, 2013
Application Purpose
Original Equipment
Date of Application
Aug 22, 2013
Equipment Note
Z-Wave USB Adapter
Frequency Range
908.40000000 - 916.00000000
Company
Sigma Designs Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. UZB-SD3503 Z-Wave USB Adapter User’s Manual UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. CONTENTS 1. INTRODUCTION ..........................................................................................................................3 2. SPECIFICATIONS ..........................................................................................................................4 3. PC CONTROLLER APPLICATION SOFTWER INSTALLATION .............................................................5 4.1 Installation .............................................................................................................................5 4.2 Start the Z-Wave PC Controller application ..............................................................................8 4.3 Remove Z-Wave PC Controller application Software ................................................................9 4.4 User Interface ....................................................................................................................... 10 4. FCC NOTICE TO USERS ............................................................................................................... 22 5. EU DECLARATION OF CONFORMITY ........................................................................................... 23 UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. 1. INTRODUCTION UZB, Z-Wave USB Stick and bundled application software (PC Controller) enables you to control a range of Z-Wave enabled devices through your PC or Notebook. Z-wave is an established short range interoperable two-way RF mesh network technology. Refer to http://www.z-wave.com/modules/ZwaveStart/ for detail of the technology. Refer to http://www.z-wave.com/modules/Products/ for various Z-Wave ready products. Refer to http://www.z-wavealliance.org/modules/AllianceStart/ for Z-Wave Alliances. Features  Simply plug in UZB to USB port of a PC/Notebook with PC Controller installed  Fully compatible with Z-wave enable network that can communicate with any Z-wave certified device. System Requirements  Windows 2000/XP/Vista 7 32 & 64 bit  Linux kernel 2.6.24+ UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. 2. SPECIFICATIONS Z-Wave & RF Specification RF EU US Z-Wave Chip SD3503 Z-Wave Library Serial API Version 4 Basic Device Class Static Controller Z-Wave Protocol Z-Wave version ZDK 4.5x and ZDK6.0x Data Rate 9.6kbps / 40kbps / 100kbps Frequency 9.6 kbps: 40 kbps: 100 kbps: 868.42 MHz 868.40 MHz 869.85 MHz 9.6 kbps: 40 kbps: 100 kbps: 908.42 MHz 908.40 MHz 916.00 MHz Range Typical 40 meters UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. 3. PC CONTROLLER APPLICATION SOFTWER INSTALLATION 4.1 Installation 1. Exit all programs. 2. Run the installation file of the Z-Wave PC Controller application. Figure 1. Welcome page of Z-Wave PC Controller installation 3. Select the installation folder and who should be able to use the Z-Wave PC Controller application. Please note, that it is not recommended to move the Z-Wave PC Controller application manually after it has been installed into the above specified folder. When done, click Next. UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. Figure 2. Installation folder 4. Installation confirmation appears. Click Next again to confirm and start the installation. Figure 3. Confirmation page of Z-Wave PC Controller installation UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. 5. The actual installation procedure will pass with progress indicator and final confirmation appears. 6. Click Close to complete the installation. Figure 4. Installation complete UZB-SD3503 Z-Wave USB Adapter 1 1 All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be edited, copied or circulated without prior written agreement by Sigma Designs. © 2012 Sigma Designs, Inc. 4.2 Start the Z-Wave PC Controller application You can start the Z-Wave PC Controller using the Start menu. To open the Start menu, click the Start button in the lower-left corner of your screen. Or, press the Windows logo key on your keyboard. The Start menu appears. To open Z-Wave PC Controller, click its icon shown in t…

Text truncated - open the document above for the full version.

ID Label/Location Info

UZB-SD3503 FCC ID Label and Location UZB-SD3503 V1.0 P 1 of 2 23 Jul 2013 Sigma Designs, Inc UZB-SD3503 (Z-Wave 500 Series) FCC ID Label and Location Ver. 1.0 23 rd July 2013 UZB-SD3503 FCC ID Label and Location UZB-SD3503 V1.0 P 2 of 2 23 Jul 2013 Sigma Designs, Inc 1 FCC LABEL WORDING, DIMENSIONS & LOCATION The Label will be printed on a WHITE Sticker with following wordings and logo:- The dimension of the WHITE Sticker is 35mm x 10mm. Please note that the black box is not part of the label. It is used to indicate the edge of the WHITE sticker. The WHITE Sticker will be stick onto the back casing of UZB as depicted in the diagrams below.

Internal Photos

Page 2 Page 3

Operational Description

FCC ID: D87-SG-UZB3503 Report No.: RF130710C03 Operational Description The transmitter of the EUT (Z-Wave USB Adapter) is powered by 5Vdc from host equipment. The output power of this device is very low. Under normal use condition, the transmitter and the receiver are quite close, so high EIRP power is neither necessary nor allowed because of interference. For more detailed instruction, please take a look at the user’s manual.

Test Report

Report No.: RF130710C03 1 of 47 Report Format Version 5.0.0 FCC TEST REPORT REPORT NO.: RF130710C03 MODEL NO.: UZB FCC ID: D87-SG-UZB3503 RECEIVED: Jul. 15, 2013 TESTED: Jul. 30 ~ Jul. 31, 2013 ISSUED: Jul. 31, 2013 APPLICANT : Sigma Designs, Inc ADDRESS : 1778 McCarthy Blvd., Milpitas, California, United States, 95035 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF130710C03 2 of 47 Report Format Version 5.0.0 Table of Contents RELEASE CONTROL RECORD .............................................................................................................. 3 1. CERTIFICATION ......................................................................................................................... 4 2. SUMMARY OF TEST RESULTS ................................................................................................. 5 2.1 MEASUREMENT UNCERTAINTY .............................................................................................. 5 3. GENERAL INFORMATION ......................................................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................ 6 3.2 DESCRIPTION OF TEST MODES .............................................................................................. 6 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................................. 7 3.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................ 8 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ......................................................................... 8 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................. 9 4. TEST TYPES AND RESULTS ................................................................................................... 10 4.1 RADIATED EMISSION MEASUREMENT ................................................................................. 10 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .............................................................. 10 4.1.2 TEST INSTRUMENTS ............................................................................................................... 11 4.1.3 TEST PROCEDURES ............................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ..................................................................................... 12 4.1.5 TEST SETUP ............................................................................................................................ 13 4.1.6 EUT OPERATING CONDITIONS .............................................................................................. 13 4.1.7 TEST RESULTS ........................................................................................................................ 14 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................................ 26 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ......................................................... 26 4.2.2 TEST INSTRUMENTS .............................................................................................................. 26 4.2.3 TEST PROCEDURES ............................................................................................................... 27 4.2.4 DEVIATION FROM TEST STANDARD ..................................................................................... 27 4.2.5 TEST SETUP ............................................................................................................................ 28 4.2.6 EUT OPERATING CONDITIONS .............................................................................................. 28 4.2.7 TEST RESULTS ........................................................................................................................ 29 4.3 BAND EDGE MEASUREMENT ................................................................................................ 35 4.3.1 LIMITS OF BAND EDGE MEASUREMENT .............................................................................. 35 4.3.2 TEST INSTRUMENTS ...............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST 2 RADIATED EMISSION TEST

Contact Information

Applicant

Robert Pleva(Director of Technical Marketing)
[email protected]510-897-0220Fax: 510-897-0350

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C908.4 MHz - 916 MHz-
Confidentiality
Long Term

Other Applications from Sigma Designs Inc

Z-Wave USB Stick - FCC ID D87-UZB3-U - Sigma Designs Inc
D87-UZB3-U

Z-Wave USB Stick

Oct 25, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Z-Wave & Infra Red Remote Control - FCC ID D87-SG-ZIRC3502 - Sigma Designs Inc
D87-SG-ZIRC3502

Z-Wave & Infra Red Remote Control

Aug 22, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Z-Wave Serial Interface Module with On-Board Antenna - FCC ID D87-ZM5304-U - Sigma Designs Inc
D87-ZM5304-U

Z-Wave Serial Interface Module with On-Board Antenna

Aug 22, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Z-Wave Over IP Gateway - FCC ID D87-SG-ZIPR3503 - Sigma Designs Inc
D87-SG-ZIPR3503

Z-Wave Over IP Gateway

Aug 22, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ZIRC Z-Wave/Infra-red Audio Video Remote Control - FCC ID D87-SG-ZIRC - Sigma Designs Inc
D87-SG-ZIRC

ZIRC Z-Wave/Infra-red Audio Video Remote Control

Sep 05, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter