FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Somfy Systems/
  3. DWN-ROLLUPZB24

DWN-ROLLUPZB24ROLL UP2 24 Zigbee HP LI-ON 5178669

Somfy Systems
ROLL UP2 24 Zigbee HP LI-ON 5178669 - FCC ID DWN-ROLLUPZB24 - Somfy Systems
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 23, 2025
Application Purpose
Original Equipment
Equipment Note
ROLL UP2 24 Zigbee HP LI-ON 5178669
Frequency Range
2402.00000000 - 2480.00000000
Company
Somfy Systems
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

O RIGINAL INSTRUCTIONS Complete instruction guide available online on www.somfy.info 1 3 2 x2 x3 12 s START UPDRIVE SETTING USE DRIVE RESETTING Short installation guide UP DOWN This drive does not require any maintenance operation. STOPMY For initial unpackaging of drive, wake up the drive by briefly pressing the motor head programming button or plugging in the charger. This reset deletes all programmed control points, all end limit settings, resets the favourite (my) position for the drive and leaves the current Zigbee network. From the Application “Help me by Somfy” scan the QR code here to find complete setting instructions. “Help me by Somfy” available on stores WAKE UP THE DRIVE To set the drive, download "TaHoma pro" application available on stores Once the "TaHoma pro" application is downloaded, open the app and follow the instructions to set the drive. INSTRUCTIONS TO BE RESPECTED These instructions apply to all ROLL UP2 24 Zigbee HP LI-ION drive, the different versions of which are available in the current catalogue. FIELD OF APPLICATION The Roll Up 24 drives are designed to motorise all types of: –Interior vertical blinds which front rail moves solely by gravity with a mass less than 15 kg. LIABILITY Please read these instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the instructions detailed in the attached Safety instructions document must also be observed. The drive must be installed by a motorisation and home automation professional, according to instructions from Somfy and the regulations applicable in the country in which it is commissioned. It is prohibited to use the drive outside the field of application described above. Such use, and any failure to comply with the instructions given in this guide and in the attached Safety instructions document, absolves Somfy of any liability and invalidates the warranty. The installer must inform its customers of the operating and maintenance conditions for the drive and must provide them with the instructions for use and maintenance, and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation on the drive must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain additional information, contact a Somfy adviser or go to the website www.somfy.com. SAFETY INSTRUCTIONS FOR WIRING Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve. Attach cables to prevent any contact with moving parts. If the drive is used outdoors, and if the power supply cable is a type H05VV-F cable, the cable should be installed in a UV-resistant duct, e.g. under a gland. Leave the drive power supply cable accessible: the product must be easily replaceable. Always make a loop in the power supply cable to prevent water entering the drive. WARNING To ensure electrical safety, this Class III drive must be powered by a «SELV» voltage source (Safety Extra Low Voltage). The drive must be installed by a motorisation and home automation professional (for example electrical specialist according to DIN VDE 0100-100 for Germany), according to instructions from Somfy and the regulations applicable in the country in which it is commissioned. Using this drive with any products which are not listed in the attached «Compatibility matrix» document shall also render invalid any Somfy warranty and release Somfy from any liability. For the purposes of recharging the battery, only use the detachable supply unit provided with this appliance. Improper using battery pack may cause overheat, fire, explosion, resulting in serious injury or death. Do not expose the drive or battery to excessive temperatures. There is a risk if terminals of the battery-operated drive or battery being short circuited by metal objects. Ensure battery is fully charged prior to installation on site. To increase the life of the battery, it is recommended to fully charge it every year. 5184975A EN EN ROLL UP2 24 Zigbee HP LI-ION SPECIFIC INSTRUCTIONS FOR ASSEMBLY ROLL UP2 24 Zigbee HP LI-ION : interior diameter of the tube has to be Ø 22 mm or greater. Frequency bands and Maximum power used Power supply 2.4 GHz - 2.4835 GHz e.r.p. <63mW [USA, Australia, Canada] 2.4 GHz - 2.4835 GHz e.r.p. <10mW [Other countries] 15V DC-1A class 2 power supply SELV + LPS 0 °C to 40 °CCharging temperature The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by SOMFY ACTIVITES SA is under license. Other trademarks and trade names are those of their respective owners. ReferenceDesignation 5178669ROLL UP2 24 Zigbee HP LI-ION Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF RADIATION EXPOSU…

Text truncated - open the document above for the full version.

Attestation Statements

Somfy Systems, Inc., 121 Herrod Blvd., Dayton, NJ 08810 CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: 08-21-2025 FCC ID: DWN-ROLLUPZB24 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Somfy Systems, Inc. (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. Contact Person: Jim Hellander Company Name: Somfy Systems, Inc. ( FRN# 0006579940) Company US Address: 121 Herrod Blvd., Dayton, NJ 08810 Email: [email protected] Sincerely yours, Jim Hellander

Attestation Statements

Somfy Systems, Inc. 121 Herrod Blvd., Dayton, NJ 08810 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-21-25 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: DWN-ROLLUPZB24 Somfy Systems, inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Somfy Systems, Inc. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Jim Hellander Somfy Systems, Inc. 121 Herrod Blvd., Dayton, NJ 08810 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 07-17-25 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: DWN-ROLLUPZB24 Somfy Systems, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Jim Hellander

Cover Letter(s)

Date: August 25, 2025 Ref: Application for FCC & ISED Certification on Somfy Tx under FCC ID: DWN-ROLLUPZB24 & IC:12049A-ROLLUPZB24 Ctrl#: 0048-250825-01 F rom: Wei Li, Advanced Compliance Laboratory To Whom It May Concern: Dear Sir/ Madam, We, Advanced Compliance Laboratory, as EMC testing lab and agent, would like to represent the applicant, Somfy Systems to apply for your approval on product authorization for new certification under FCC ID: DWN-ROLLUPZB24 & IC:12049A-GL2UWF50ZHP. The investigation for the EMC performance of the EUT(s), ROLL UP2 24 Zigbee HP LI-ON, Model# 5178669, performed in May, 2025 on behalf of the applicant. It was found that EUTs comply with the requirements of FCC Part 15.247 & RSS-247, RSS-Gen. The system was configured as the typical condition during the test. Enclosed please find the test data/report with application forms. The measurement facility used to collect the test data is BUREAU VERITAS ADT (Shanghai) Corporation, located at No. 829, Xinzhuan Road, Shanghai, P.R.China (201612), which is currently accredited by A2LA with cert # 2343.01. Should you need more information, please contact me at (908) 392-3378 or email me to [email protected]. Your attention is highly appreciated. Sincerely, Wei Li Manager Advanced Compliance Laboratory, Inc. 210 Cougar Court Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Lab

Cover Letter(s)

August 21, 2025 FCC ID: DWN-ROLLUPZB24 IC ID: 12049A-ROLLUPZB24 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the schematics, block diagram, operational description of the EUT treated as confidential. The information contained within is a result of extensive investment and development effort by Somfy Systems, Inc. and its disclosure will compromise Somfy's Intellectual Property and competitive edge. We thus ask the FCC and IC NOT to publish the information mentioned above, in order to protect Somfy's Intellectual Property. Regards, Somfy Systems, Inc. Jim Hellander Electronics Engineer

External Photos

ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 PHOTOS OF EUT – EXTERNAL COMPLETE EUT ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 EUT HEAD ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 EUT HEAD ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 EUT HEAD ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 EUT OUTPUT SHAFT ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 EUT OUTPUT SHAFT ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225 ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 9/08/225

ID Label/Location Info

ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 ID Label Label position

Internal Photos

ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 8/25/225 PHOTOS OF EUT – INTERNAL EUT HEAD PCBA ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 8/25/225 EUT HEAD PCBA ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 8/25/225 EUT DISASSEMBLED ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 8/25/225 EUT MAIN PCBA EUT MAIN PCBA ROLLUP 2 24 ZIGBEE HP LI-ION DWN-ROLLUPZB24 12049A-ROLLUPZB24 Somfy Systems, Inc. 8/25/225 EUT MAIN & HEAD PCBA CONNECTED

RF Exposure Info

Report No.: LDF-ESH-P23121109B-3-A1 Page No. 1 / 7 Report Format Version: 6.1.1 MPE Test Report Report No.: LDF-ESH-P23121109B-3-A1 FCC ID: DWN-ROLLUPZB24 Product: ROLL UP2 24 ZIGBEE HP LI-ION Model: 5178669 Received Date: Apr.28, 2025 Test Date: April 29, 2025 to May 10, 2025 Issued Date: May.13, 2025 Applicant: Somfy Systems, Inc. Address: 121 Herrod Blvd. Dayton, NJ 08810 Manufacturer: Somfy Systems, Inc. Address: 121 Herrod Blvd. Dayton, NJ 08810 Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P23121109B-3-A1 Page No. 2 / 7 Report Format Version: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 3 1 General Information ........................................................................................................................... 5 1.1 General Description of EUT............................................................................................................ 5 2 RF Exposure ..................................................................................................................................... 7 2.1 Limits For Maximum Permissible Exposure (MPE) ......................................................................... 7 2.2 MPE Calculation Formula ............................................................................................................... 7 2.3 MPE Calculation Formula ............................................................................................................... 7 2.4 Calculation Result of Maximum Permissible Exposure.................................................................... 7 Report No.: LDF-ESH-P23121109B-3-A1 Page No. 3 / 7 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued LDF-ESH-P23121109B-3 Original release Feb.02, 2024 LDF-ESH-P23121109B-3-A1 Update product information May.13, 2025 Report No.: LDF-ESH-P23121109B-3-A1 Page No. 5 / 7 Report Format Version: 6.1.1 2 General Information 2.1 General Description of EUT For BLE Product ROLL UP2 24 ZIGBEE HP LI-ION Brand Test Model 5178669 Power Rating Tubular motor: 12V ; 0,9A; Rated torque:0,55Nm; Operating time:4minutes. Modulation Type GFSK Modulation Technology Bluetooth Low Energy 5.0 Operating Frequency 2402MHz ~ 2480MHz Number of Channel 40 Antenna Type External Antenna Antenna Connector -- Antenna Gain 2 dBi Note: 1.For more details, please refer to the User’s manual of the EUT. Report No.: LDF-ESH-P23121109B-3-A1 Page No. 6 / 7 Report Format Version: 6.1.1 For Zigbee Product ROLL UP2 24 ZIGBEE HP LI-ION Brand Test Model 5178669 Power Rating Tubular motor: 12V ; 0,9A; Rated torque:0,55Nm; Operating time:4minutes. Modulation Type O-QPSK Modulation Technology 6LoWPAN Operating Frequency 2405MHz to 2480MHz Number of Channel 16 Antenna Type External Antenna Antenna Connector -- Antenna Gain 2 dBi 2.2 Test Facility Laboratory Name: BUREAU VERITAS ADT (Shanghai) Corporation Laboratory Address: No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China Test Location: No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China A2LA Lab Code: 2343.01 FCC-Recognized Accredited Testing Lab: CN1213 ISED Recognized Lab: 6392A FCC Accredited Test Site Number: 176467 Report No.: LDF-ESH-P23121109B-3-A1 Page No. 7 / 7 Report Format Version: 6.1.1 3 RF Exposure 3.1 Limits For Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 300-1,500- - F/1500 30 1,500-100,000 - - 1.0 30 F = Frequency in MHz 3.2 MPE Calculation Formula Power density (S) is calculated according to the formula: S = PG / (4πR²) Where S = power density in mW/cm² P = transmit power in mW G = numeric gain of transmit antenna (numeric gain=Log-1(dB antenna gain/10)) R = distance (cm) 3.3 MPE Calculation Formula The antenna of this product, under normal use condition, is at least 20cm from the body of the user. So the device is classified as Mobile Device. 3.4 Calculation Result of Maximum Permissible Exposure Frequency Band (MHz) Max. Conducted output power(dBm) Antenna Gain (dBi) Distance (cm) Power Density (mW/cm 2…

Text truncated - open the document above for the full version.

Test Report

Report No.: LDF-ESH-P23121109B-2-A1 Page No. 1 / 50 Report Format Verision: 6.1.1 FCC Test Report Report No.: LDF-ESH-P23121109B-2 FCC ID: DWN-ROLLUPZB24 Product: ROLL UP2 24 ZIGBEE HP LI-ION Test Model: 5178669 Received Date: Apr.28, 2025 Test Date: -- Issued Date: May.13, 2025 Applicant: Somfy Systems, Inc. Address: 121 Herrod Blvd. Dayton, NJ 08810 Manufacturer: Somfy Systems, Inc. Address: 121 Herrod Blvd. Dayton, NJ 08810 Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P23121109B-2-A1 Page No. 2 / 50 Report Format Verision: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 5 1Certificate of Conformity .................................................................................................................... 6 2Summary of Test Results ................................................................................................................... 7 2.1Test Facility .................................................................................................................................... 7 2.2Test Instruments ............................................................................................................................ 8 2.3Measurement Uncertainty .............................................................................................................. 9 2.4Modification Record ....................................................................................................................... 9 3General Information ..........................................................................................................................10 3.1General Description of EUT...........................................................................................................10 3.2Description of Test Modes ............................................................................................................. 11 3.3Description of system under test ................................................................................................... 11 3.3.1 Test Mode Applicability: .................................................................................................................12 3.3.2 Test Condition: ..............................................................................................................................13 3.4Duty Cycle of Test Signal ..............................................................................................................14 3.5Description of Support Units ..........................................................................................................16 3.6General Description of Applied Standards .....................................................................................16 4Test Procedure and Results ..............................................................................................................17 4.1AC Power Conducted Emission.....................................................................................................17 4.1.1 Limits ............................................................................................................................................17 4.1.2 Test Procedures ............................................................................................................................17 4.1.3 Deviation from Test Standard.........................................................................................................17 4.1.4 Test Setup .....................................................................................................................................18 4.1.5 EUT Operating Conditions .............................................................................................................18 4.1.6 Test Results ..................................................................................................................................19 4.2Minimum 6dB Bandwidth...............................................................................................................21 4.2.1 Limit .......................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: LDF-ESH-P23121109B-1-A1 Page No. 1 / 50 Report Format Verision: 6.1.1 FCC Test Report Report No.: LDF-ESH-P23121109B-1-A1 FCC ID: DWN-ROLLUPZB24 Product: ROLL UP2 24 ZIGBEE HP LI-ION Test Model: 5178669 Received Date: Apr.28, 2025 Test Date: -- Issued Date: May.13, 2025 Applicant: Somfy Systems, inc. Address: 121 Herrod Blvd, Dayton, NJ 08810 Manufacturer: Somfy Systems, Inc. Address: 121 Herrod Blvd. Dayton, NJ 08810 Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P23121109B-1-A1 Page No. 2 / 50 Report Format Verision: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 5 1Certificate of Conformity .................................................................................................................... 6 2Summary of Test Results ................................................................................................................... 7 2.1Test Facility .................................................................................................................................... 7 2.2Test Instruments ............................................................................................................................ 8 2.3Measurement Uncertainty .............................................................................................................. 9 2.4Modification Record ....................................................................................................................... 9 3General Information ..........................................................................................................................10 3.1General Description of EUT...........................................................................................................10 3.2Description of Test Modes ............................................................................................................. 11 3.3Description of system under test ................................................................................................... 11 3.3.1 Test Mode Applicability: .................................................................................................................12 3.3.2 Test Condition: ..............................................................................................................................13 3.4Duty Cycle of Test Signal ..............................................................................................................14 3.5Description of Support Units ..........................................................................................................16 3.6General Description of Applied Standards .....................................................................................16 4Test Procedure and Results ..............................................................................................................17 4.1AC Power Conducted Emission.....................................................................................................17 4.1.1 Limits ............................................................................................................................................17 4.1.2 Test Procedures ............................................................................................................................17 4.1.3 Deviation from Test Standard.........................................................................................................17 4.1.4 Test Setup .............................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

James P Hellander(Industrial Operations Manager)
[email protected]Fax: 609-495-8153

Test Firm

BUREAU VERITAS LCIE CHINA COMPANY LIMITEDFrank Wu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
115C2.40 GHz - 2.48 GHz2.40 mW1M02G1D
215C2.40 GHz - 2.48 GHz16.50 mW2M24G1D
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing.

Other Applications from Somfy Systems

Ysia 1, Ysia 5, Ysia 5 TDBU HP Zigbee II, 5175210B, 5175211B, 5175066B - FCC ID DWNV2TDBUBL - Somfy Systems
DWNV2TDBUBL

Ysia 1, Ysia 5, Ysia 5 TDBU HP Zigbee II, 5175210B, 5175211B, 5175066B

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
Ysia 5 Variation HP Zigbee II, 5171079B - FCC ID DWNVARBL - Somfy Systems
DWNVARBL

Ysia 5 Variation HP Zigbee II, 5171079B

Aug 18, 2026

Equipment Class

DTS - Digital Transmission System
TDBU 25 WF Zigbee HP 5183668 - FCC ID DWNTDBU25ZB - Somfy Systems
DWNTDBU25ZB

TDBU 25 WF Zigbee HP 5183668

Jun 23, 2026

Equipment Class

DTS - Digital Transmission System
Decoflex RTS In-Wall Mount 1810830 - FCC ID DWNDECOFLEX2 - Somfy Systems
DWNDECOFLEX2

Decoflex RTS In-Wall Mount 1810830

Feb 25, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Ysia 5 TDBU HP Zigbee 5175066A - FCC ID DWNV2TDBU - Somfy Systems
DWNV2TDBU

Ysia 5 TDBU HP Zigbee 5175066A

Oct 02, 2024

Equipment Class

DTS - Digital Transmission System