F6O-INBODY-H20Body Composition Analyzer

InBody Co., Ltd.
Body Composition Analyzer - FCC ID F6O-INBODY-H20 - InBody Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 15, 2020
Application Purpose
Original Equipment
Date of Application
Jun 15, 2020
Equipment Note
Body Composition Analyzer
Frequency Range
2402.00000000 - 2480.00000000
Company
InBody Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User’s Manual H20B_manual_ENG_B_200222_129x183.indd 12020-03-12 오후 2:31:35 For any problems with the InBody Dial or any clinical questions, contact: InBody Co., Ltd. [HEAD OFFICE] 625, InBody Bldg., Eonju-ro, Gangnam-gu, Seoul 06106 Republic of Korea TEL: +82-2-501-3939 FAX: +82-2-578-5669 Website: inbody.com E-mail: [email protected] ©2020 InBody Co., Ltd. All rights reserved. Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd. under the copyright laws. This manual might have typographical errors, and its content can be changed without prior notice. InBody Co., Ltd. shall not be liable for any errors, incidental, or consequential damages that occurred by not complying with the content of the User̓s Manual. Representative & Sponsor Information InBody Europe B.V. Gyroscoopweg 122, 1042 AZ, Amsterdam, The Netherlands TEL: +31-20-238-6080 FAX: +31-6-5734-1858 Website: nl.inbody.com E-mail: [email protected] Australian Sponsor. [AUSTRALIA] Emergo AUSTRALIA. Level 20, Tower II, Darling Park, 201 Sussex Street, Sydney, NSW 2000, AUSTRALIA TEL: +61-2-9006-1662 FAX: +61-2-9006-1010 Website: emergogroup.com E-mail: [email protected] Customer Service Information InBody USA [USA] 13850 Cerritos Corporate Dr. Unit C Cerritos, CA 90703 USA TEL: +1-323-932-6503 FAX: +1-323-952-5009 Website: inbody.com E-mail: [email protected] InBody Japan [JAPAN] Tani Bldg., 1-28-6, Kameido, Koto-ku, Tokyo 136-0071 Japan TEL: +81-3-5875-5780 FAX: +81-3-5875-5781 Website: inbody.co.jp E-mail: [email protected] InBody China [CHINA] 903, 904, XingDiPlaza, No.1698 YiShanRoad, Shanghai 201103 China TEL: +86-21-64439705 FAX: +86-21-64439706 Website: inbodychina.com E-mail: [email protected] Please note the important information below before reading this manual. Failure to comply with safety warnings and regulations can cause serious injury or death. Failure to comply with safety cautions and regulations can cause injury or property damage. Warning Caution H20B_manual_ENG_B_200222_129x183.indd 32020-03-12 오후 2:31:36 InBody Test Posture Stretch out your arms. Avoid contact with your waist. Put your thumb on the round electrodes. Place your heel at the end of the heel electrodes and allow the rest of your foot to point forward. H20B_manual_ENG_B_200222_129x183.indd 42020-03-12 오후 2:31:37 Contents 2 3 4 6 7 8 9 11 12 13 14 15 17 17 Precautions Product Components and Set-Up Instructions A. Product Components B. Installing InBody App Weight Measurement InBody Test A. Precautionary Steps B. Test Posture C. Test Instructions D. Understanding InBody Outputs E. Standard Range Graph of Weight and Muscle Mass Troubleshooting A. Error Message B. Solving Simple Problems Frequently Asked Questions (FAQ) Others A. Classification B. Specifications Product Warranty I. II. III. IV. V. VI. VII. H20B_manual_ENG_B_200222_129x183.indd 52020-03-12 오후 2:31:37 23 2 Do not use as follows: 1. People with medical devices including an implantable medical device or a patient monitoring device, such as a Pacemaker, should not use the InBody. InBody Co., Ltd. is not liable for any incidental or consequential damages that occur. 2. Keep your InBody device away from other electronics while testing. It may cause errors. 3. Sterilize the InBody with a soft cloth or with ethyl alcohol wipes before each use. Do not pour liquids onto the InBody. It may cause the product to short circuit or cause electric shock. People with contagious diseases should not use an InBody device. 4. Excessively high or low temperatures, humidity, and pressure can affect the accuracy of the InBody. Do not use in a humid place such as a bathroom. 5. Keep food, beverages and other liquids away from your InBody device. 6. Do not disassemble the InBody. It can cause electric shock or damage, product malfunction, and other errors. InBody Co., Ltd. will not be liable for any incidental or consequential injuries or damages from the product that occurred. 7. Do not use this product for purposes other than body composition analysis or weight measurement. Use as follows: 1. If you cannot maintain the correct testing posture to take the InBody Test alone, request assistance from a helper. Help children maintain the proper posture during the measurement. 2. Place the InBody on a flat and vibrationless floor. Placing it on an uneven floor, like a carpet or a mattress can result in incorrect measurements. For long-term storage, remove the battery pack, and place it on a flat surface. 3. Use the packing material provided with the product when moving your InBody. Dispose waste in compliance with the law. 4. Only trained InBody service team members can repair InBody devices. If your device is in need of repair, please contact us at [email protected]. I. Precautions H20B_manual_ENG_B_200222_129x183.indd 22020-03-12 오후 2:31:37 23 3 II. Product Components A. Product Components Product components : InBody, User’s Manual, AA Battery (4) Hand electrodes Display screen Dial Foot electrodes Footplate (주)인바디, 충청남도 천안시 서북구 입장면 흑암길 15 Battery insert Back cover Display screen: Displays outcomes on the screen. Dial: Use to power ON/OFF, input height and check results. Hand electrodes: User holds the device with hands and fingers. Foot electrodes: User stands on the device, placing the back of heels on the rear electrodes. Footplate: Measures the weight of the user. Battery insert: The InBody takes 4 AA batteries. Open the cover to insert the batteries. Back cover: Only InBody service team members can open. H20B_manual_ENG_B_200222_129x183.indd 32020-03-12 오후 2:31:37 45 II. Product Components B. Installing InBody App ❶ Make sure to download and install the InBody App on your smartphone prior to testing. (min. iOS 8, min. Android 5.0) ❷ Download the InBody App from iPhone App Store and Google Play Store. Scan the QR Code below to move to the App Download page. For an Android phone, turn on NFC(Read/Write) and touch the NFC mark on the…

Text truncated - open the document above for the full version.

Cover Letter(s)

Letter of Authorization Company : InBody Co., Ltd. Address : InBody Bldg., 625, Eonju-ro, Gangnam-gu, Seoul, 06106, South Korea Product Name : Body Composition Analyzer Model Number : InBody H20B FCC Identifier : F6O-INBODY-H20 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Kyung Keun, Kim Date: June 15, 2020 Title: Manager Signature of applicant:

Cover Letter(s)

Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: June 15, 2020 Subject; Request for Confidentiality FCC ID: F6O-INBODY-H20 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. • Schematic Diagram • Block Diagram • Part List • Operational Description Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission' s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. • External Photos • Internal Photos • Test Setup Photos • User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Name: Kyung Keun, Kim Title: Manager

External Photos

Page 1 of 6 Page 2 of 6 Page 3 of 6 Page 4 of 6 Page 5 of 6 Page 6 of 6

ID Label/Location Info

Page 1 of 1 IDENTIFICATION LABEL: PROPOSED LABEL The shall be permanently affixed in the rear side of the equipment

Internal Photos

Page 1 of 9 Page 2 of 9 Page 3 of 9 Page 4 of 9 Page 5 of 9 Page 6 of 9 Page 7 of 9 Page 8 of 9 Page 9 of 9 Chip Antenna

RF Exposure Info

Page 1 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT FOR LOW-POWER, NON-LICENSED TRANSMITTER Test Report No. : OT-206-RWD-026 AGR No. : A204A-172 Applicant : InBody Co., Ltd. Address : InBody Bldg., 625, Eonju-ro, Gangnam-gu, Seoul, 06106, South Korea Manufacturer : InBody Co., Ltd. Address : 15, Heugam-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do 31025 KOREA Type of Equipment : Body Composition Analyzer FCC ID. : F6O-INBODY-H20 Model Name : InBody H20B Multiple Model Name : N/A Serial number : N/A Total page of Report : 7 pages (including this page) Date of Incoming : April 27, 2020 Date of issue : June 15, 2020 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Tae-Ho, Kim / Senior Manager Ki-Hong, Nam / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 4 2. GENERAL INFORMATION ............................................................................................................................................ 5 2.1 PRODUCT DESCRIPTION ................................................................................................................................................. 5 2.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 5 3. EUT MODIFICATIONS .................................................................................................................................................... 5 4. MAXIMUM PERMISSIBLE EXPOSURE ...................................................................................................................... 6 4.1 APPLICABLE STANDARD ................................................................................................................................................ 6 4.2 EUT DESCRIPTION ......................................................................................................................................................... 6 4.3 TEST RESULT ................................................................................................................................................................. 7 Page 3 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) Revision History Rev. No. Issue Report No. Issued Date Revisions Section Affected 0 OT-206-RWD-026 June 15, 2020 Initial Release All Page 4 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 1. VERIFICATION OF COMPLIANCE Applicant : InBody Co., Ltd. Address : InBody Bldg., 625, Eonju-ro, Gangnam-gu, Seoul, 06106, South Korea Contact Person : Kyung Keun, Kim / Manager Telephone No. : +82-2-300-2241 FCC ID : F6O-INBODY-H20 Model Name : InBody H20B Brand Name : Serial Number : N/A Date : June 15, 2020 EQUIPMENT CLASS DTS – DIGITAL TRNSMISSION SYSTEM E.U.T. DESCRIPTION Body Composition Analyzer THIS REPORT CONCERNS Original Grant MEASUREMENT PROCEDURES ANSI C63.10: 2013 TYPE OF EQUIPMENT TESTED Pre-Production KIND OF EQUIPMENT AUTHORIZATION REQUESTED Certification EQUIPMENT WILL BE OPERATED UNDER FCC RULES PART(S) FCC PART 15 SUBPART C Section 15.247 KDB 558074 D01 15.247 Meas Guidance v05r02 Modifications on the Equipment to Achieve Compliance None Final Test was Conducted On 10 m, Semi Anechoic Chamber -. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 5 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 2. GENERAL INFORMATION 2.1 Product Description The InBody Co., Ltd., Model InBody H20B (referred to as the EUT in this report) is a Body Composition Analyzer. The product specification described herein was obtained from product data sheet or user’s manual. Device Type Body Composition Analyzer Temperature Range 10 °C ~ 40 °C Operating Frequency 2 402 MHz ~ 2 480 MHz RF Output Power -0.81 dBm Number of Channel 40 Channel Modulation Type GFSK (Bluetooth LE) Antenna Type Chip Antenna Antenna Gain 1.99 dBi List of each Osc. or crystal Freq.(Freq. >= 1 MHz) 16 MHz 2.2 Alternative type(s)/model(s); also covered by this test report. -. None 3. EUT MODIFICATIONS -. None Page 6 of 7 Report No.: OT-206-RWD-026 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-1…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 32 Report No.: OT-206-RWD-025 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT FOR LOW-POWER, NON-LICENSED TRANSMITTER Test Report No. : OT-206-RWD-025 AGR No. : A204A-172 Applicant : InBody Co., Ltd. Address : InBody Bldg., 625, Eonju-ro, Gangnam-gu, Seoul, 06106, South Korea Manufacturer : InBody Co., Ltd. Address : 15, Heugam-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do 31025 KOREA Type of Equipment : Body Composition Analyzer FCC ID. : F6O-INBODY-H20 Model Name : InBody H20B Multiple Model Name : N/A Serial number : N/A Total page of Report : 32 pages (including this page) Date of Incoming : April 27, 2020 Date of issue : June 15, 2020 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Tae-Ho, Kim / Senior Manager Ki-Hong, Nam / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 32 Report No.: OT-206-RWD-025 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 5 2. TEST SUMMARY .............................................................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 7 4. EUT MODIFICATIONS .................................................................................................................................................... 7 5. SYSTEM TEST CONFIGURATION ............................................................................................................................... 8 5.1 JUSTIFICATION ............................................................................................................................................................... 8 5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8 5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................... 9 6. PRELIMINARY TEST ...................................................................................................................................................... 9 6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ......................................................................................................... 9 6.2 GENERAL RADIATED EMISSIONS TESTS ....................................................................................................................... 9 7. MINIMUM 6 DB BANDWIDTH .................................................................................................................................... 11 7.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11 7.2 TEST SET-UP ................................................................................................................................................................. 11 7.3 TEST EQUIPMENT USED ................................................................................................................................................ 11 7.4 TEST DATA .................................................................................................................................................................... 12 8. MAXIMUM PEAK OUTPUT POWER ......................................................................................................................... 14 8.1 OPERATING ENVIRONMENT .................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 - Radiated Emission Test Page 2 of 2

Contact Information

Applicant

Min seok Lee(Manager)
[email protected]+82-02-2182-8918Fax: +82-02-578-5669

Technical Contact

InBody Co., Ltd.
[email protected]

South Korea

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from InBody Co., Ltd.

F6OH30NWIE

Body Composition Analyzer

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
Hand grip strength dynamometer - FCC ID F6OIBHGSM - InBody Co., Ltd.
F6OIBHGSM

Hand grip strength dynamometer

Sep 27, 2023

Equipment Class

JAB - Part 15 Class B Digital Device
Body Composition Analyzer - FCC ID F6OINBODYFIT - InBody Co., Ltd.
F6OINBODYFIT

Body Composition Analyzer

Jul 29, 2023

Equipment Class

DTS - Digital Transmission System
Body Composition Analyzer - FCC ID F6OINBODYBAND3 - InBody Co., Ltd.
F6OINBODYBAND3

Body Composition Analyzer

Oct 08, 2021

Equipment Class

DTS - Digital Transmission System
Blood Pressure Monitor - FCC ID F6O-INBODY-BP170B - InBody Co., Ltd.
F6O-INBODY-BP170B

Blood Pressure Monitor

Aug 19, 2020

Equipment Class

DTS - Digital Transmission System