Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TransCore 8600 Jefferson Street NE Albuquerque, New Mexico 87113 October 2010 P/N 412123 Multiprotocol Rail Reader System Guide Multiprotocol Rail Reader System Guide Information in this document is subject to change and does not represent a commitment on the part of TC License, Ltd. © 2010 TC License, Ltd. All rights reserved. TRANSCORE, AMTECH, and EGO are registered trademarks of TC License, Ltd. All other trademarks listed are the property of their respective owners. Contents are subject to change. Printed in the U.S.A. For further information, contact: TransCore 3410 Midcourt Road, Suite 102 Carrollton, Texas 75006 USA Phone:(214) 461-4031 Fax:(214) 461-6478 Technical Support Web:transcore.com/rfidsupport For comments or questions about this document, e-mail [email protected]. WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION (FCC) LOCATION AND MONITORING SERVICE STATEMENT 47 CFR §90.351 NOTE: The user is required to obtain a Part 90 site license from the FCC to operate this radio frequency identification (RFID) device in the United States. See product label for FCC ID number. Access the FCC Web site at www.fcc.gov/Forms/Form601/601.html or at wireless.fcc.gov/index.htm?job=online_filing to obtain additional information concerning licensing requirements. NOTE: Users in all countries should check with the appropriate local authorities for licensing requirements. FCC RADIO FREQUENCY INTERFERENCE STATEMENT 47 CFR §15.105(a) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate RF energy and may cause harmful interference to radio communications if not installed and used in accordance with the instruction manual. Operating this equipment in a residential area is likely to cause harmful interference, in which case, depending on the laws in effect, the user may be required to correct the interference at their own expense. NO UNAUTHORIZED MODIFICATIONS 47 CFR §15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without permission from TransCore, LP. Unauthorized modification may void the equipment authorization from the FCC and will void the TransCore warranty. USE OF SHIELDED CABLES IS REQUIRED 47 CFR §15.27(a) NOTE: Shielded cables must be used with this equipment to comply with FCC regulations. TransCore, LP USA Multiprotocol Rail Reader System Guide Health Limits for Multiprotocol Rail Reader Using Exter- nal Antenna (902 to 928 MHz) Within the United States, environmental guidelines regulating safe exposure levels are issued by the Occupational Safety and Health Administration (OSHA). Section 1910.97 of OSHA Safety and Health Standards 2206 legislates a maximum safe exposure limit of 10 milliwatts per square centimeter (mW/cm 2 ) averaged over 6 minutes at 902 MHz. Although not binding, other organizations such as the American National Standards Institute (ANSI) have issued similar guidelines that are more restrictive than the OSHA limits (ANSI C95.1). ANSI guidelines recommend a maximum safe power density in mW/cm 2 of: Frequency (in MHz) 1500 Thus, the maximum permissible exposure for general population/uncontrolled expo- sure at 902 MHz is 0.60 mW/cm 2 . The power limit is a six-minute average. The RF power density generated by the Multiprotocol Rail Reader (MPRR) was cal- culated using a maximum antenna gain of 9.5 dBd, equivalent to the antenna gain of the external antenna. Warning At 2 W conducted into the antenna and a distance of 30 inches (77 cm) from the antenna, the maximum power density calculated was less than 0.60 mW/cm 2 . Install the antenna at least 30 inches (77 cm) from the general public. Maintenance per- sonnel must remain at least 14 inches (35 cm) from antenna when system is operat- ing. The data confirms that the TransCore MPRR effectively meets OSHA requirements and thus does not represent an operating hazard to either the general public or mainte- nance personnel. Contents Contents Health Limits for Multiprotocol Rail Reader Using External Antenna (902 to 928 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv 1 Introduction Purpose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 System Guide Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Licensing Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 2 Developing the Site Plan System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Reader. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 How It Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Overview of Site Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Reading of Mixed Population Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Antenna and Tag Alignment . . . . . . . . . . . . . . . . . . . . . …
Text truncated - open the document above for the full version.
October 18, 2010 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Applicant: Transcore - Amtech Technology Center 8600 Jefferson Street NE Albuquerque, New Mexico 87113 Re: Confidentiality for submittal information regarding FCC ID number FIH05716 Product: Licensed Transmitter operating under part 90 Dear Sirs: Transcore Amtech Technology Center requests that the material in the Schematics, Operational Description, Block Diagram, and parts list be withheld from public disclosure in accordance with Section 0.459 of the Commission’s Rules, 47 C.F.R. 0.459, following grant of the application. In support of this request, Transcore Amtech Technology Center submits the following: CONFIDENTIAL FILES Block Diagram Conf BlkDia MPRR.pdf Operational Description Conf OpDes MPRR.pdf Operational Description Conf OpDes MPRR 2.pdf Schematics Conf Schem MPRR.pdf Parts List Conf PartList MPRR.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Operational Description, block diagram, parts list, and Schematics, which are segregated, from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: FIH05716 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, and schematic. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4 5 6 7 8 4. Explana competit The mate transmitt have a va 5. Explana Disclosur Center en Disclosur developm Technolo 6. Identific disclosur The infor Technolo agreemen 7. Identific previous To the kn publicly numero u FCC, the this radio 8. Justifica not be av This mat relatively and manu This equi unlike m cases. A might att equipmen Should y Thank y o Sincerel y Scot Rog ation of the d tion: erial for whic ting equipme ariety of com ation of how re would, in ngineering p re would als ment, thereby ogy Center. cation of any re: rmation for w ogy Center a nts. cation of wh s disclosure nowledge of heretofore. us disclosure e protection s o technology ation of the p vailable for erial should y frequently, ufacturing te ipment is de most consume As such, it is tempt to use nt will be em you require a ou for your c y, gers degree to wh ch confident ent that is of mpeting sour w disclosure n effect, give personnel, wh so offer comp y allowing c y measures which confid and not made hether the in of the infor f those prepa While the g s in industr y sought is nar y. period duri public disc not be discl , disclosure o echniques th esigned for c er equipment important th knowledge mployed. any further in consideration hich the inf tiality is sou ffered on a h rces. of the info r away the fru ho have desi petitors addi competitors a taken by th dential treatm e available to nformation rmation to t aring this app eneral theory y and standar rrowly draw ng which th closure: osed for at l of the design hat could hav ommercial, t, this equipm hat the design of the design nformation, p n in this mat formation co ught is emplo ighly compe rmation cou uits of the la igned the eq itional unwa an advantage he submittin ment is soug o third partie is available third parties plication, the y of operatio rds groups a wn and pertai he submittin east 25 year n information ve an adverse industrial, an ment could b n not be mad n to comprom please conta tter. oncerns a se oyed in the d etitive basis. uld result in abors of Tran quipment and arranted insig e, not availab ng party to p ght is kept co es except pu to the publ s: e information on of this eq s well as in r ns to certain ng party ass rs. While im n would lead e competitiv nd governm be used for m de available mise the app act the under ervice that i design and m Customers substantia l nscore Amte d the manufa ght into the s ble to Transc prevent una onfidential b ursuant to non lic and the e n has not be quipment has rule making n specific im serts that th mprovements d to insights ve effect for m mental applica more than a to unauthor i plications for rsigned. is subject to manufacture o for this equ l competitiv ech Technolo acturing proc state of the p core Amtech authorized by Transcore n-disclosure extent of any en disclosed s been the su proceedings mplementation he material s in design ar into both de many years ations. As s decade in s o ized persons r which the o of this uipment ve harm: ogy cess. product h e Amtech e y d ubject of s of the ns of should re made esign to come. uch, ome s who
October 18, 2010 Timco Engineering Inc. Federal Communications Commission 849 NW State Road 45 Equipment Approval Services Newberry, FL 32669 Pittsburgh, PA 15251-3315 Applicant: Transcore - Amtech Technology Center 8600 Jefferson Street NE Albuquerque, New Mexico 87113 Equipment: FCC ID: FIH05716 FCC Rules: Part 2 and 90 Sirs The form 731 and application have been electronically submitted and attachments up loaded to your site for use in processing for grant of certification. Confidentiality is requested as outlined below. Short-term Pursuant to DA 04-1705 of the Commission’s public notice, we request short-term confidential treatment for the following information until 45 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External Photographs Short Term ExtPho MPRR.pdf Test Setup Short Term TSup MPRR.pdf Internal Photographs Short Term IntPho MPRR.pdf User Manual Short Term UserMan MPRR.pdf Permanent Transcore Amtech Technology Center requests that the material in the Parts List, Schematics, block diagram, and Operational Description be withheld from public disclosure in accordance with Section 0.459 of the Commission’s Rules, CFR47 0.459, following grant of the application. It is requested that the information contained in the operational description, block diagram, parts list, internal photographs, and schematics of the application be held confidential per Section 0.459. A statement of confidentiality will be attached with the application at the time of submittal. Block Diagram Conf BlkDia MPRR.pdf Operational Description Conf OpDes MPRR.pdf Operational Description Conf OpDes MPRR 2.pdf Schematics Conf Schem MPRR.pdf Parts List Conf PartList MPRR.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone / Facsimile (913) 837-3214
October Office o f Federal C Columbi Applica n Re: Sho r FIH0571 Product: Dear Sirs Transcor from pub with DA- Short ter External Test Setu Internal P User Man Permane Block Di Operation Operation Schemati Parts Lis Should y Thank yo Sincerel y Scot Rog 18, 2010 f Engineerin Communicat a, MD 2104 nt: Trans 8600 J Albuq rt-term Confi 6 LMS s: re Amtech T blic disclosur -04-1705 of rm confiden Photograph up Photographs nual ent Confide iagram nal Descript nal Descript ics t you require a ou for your c y, gers g and Techn tions Comm 46 core - Amte Jefferson Str querque, New fidentiality re Licensed Tr echnology C re until 45 d fthe Commis ntial files s Sh Sh s Sh Sh ential files C o tion Co tion Co Co Co any further in consideration ROG 4405 Wes Louisburg (913) 837 - nology ission ch Technolo reet NE w Mexico 87 equest for su ransmitter op Center reque days after the ssion’s publi ort Term Ex ort Term TS ort Term Int ort Term Us onf BlkDia M onf OpDes M onf OpDes M onf Schem M onf PartList M nformation, p n in this mat GERS st 259 th Terrac , KS 66053 -3214 ogy Center 7113 ubmittal info perating und sts that the f e Grant of Eq ic notice. xtPho MPRR Sup MPRR.p tPho MPRR serMan MPR MPRR.pdf MPRR.pdf MPRR 2.pdf MPRR.pdf MPRR.pdf please conta tter. S LAB ce ormation rega der part 90 following inf quipment Au R.pdf pdf .pdf RR.pdf act the under BS, IN arding FCC formation be uthorization rsigned. NC. ID number e withheld in accordannce
Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: Short Term ExtPho MPRR Page 1 of 2 Equipment photographs Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: Short Term ExtPho MPRR Page 2 of 2
Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: LabelSmpl MPRR Page 1 of 2 Label Sample and Placement MPRR Multiple Protocol Railroad Radio FIH05716 1584A-05716 Label Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: LabelSmpl MPRR Page 2 of 2
Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: Short Term IntPho MPRR Page 1 of 2 Internal photographs Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: Short Term IntPho MPRR Page 2 of 2
Confidential Page 1 of 1 10/1/2010 MPRR Tune-up Procedure The Encompass 4 is factory calibrated for peak power. For peak power, the Encompass 4 is set to transmit a CW signal at 902.25 MHz at full power. This output signal is measured with an Agilent power meter (Model no. E4419B) and a high power sensor (Model no. E9301H). With the temperature compensated digital feedback control loop (TCDFCL) running, the loop reference value for peak power, which is stored in the Field Programmable Gate Array (FPGA) is adjusted to center up the peak power level to 33 dBm +/- 0.25 dB. Once this reference value is stored, the TCDFCL automatically controls the peak power across frequency and operating power levels. The unit is then tested to meet the following specifications: Power output range +18 to +33 dBm, in 1 dB steps; Accuracy +/-1.0 dB, over frequency range; Stability +/-1.25 dB, from –40 to +70 °C.
Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: RFExp MPRR Page 1 of 1
NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID#: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: October 16, 2010 Revision 1 File: Transcore MPRR TstRpt 101001 Page 1 of 40 Application Submittal Test Report For Grant of Certification Model: MPRR (Multiple Protocol Railroad Radio) LMS Location and Monitoring Service 902.25 - 903.75 and 910.0 - 921.5 MHz Transmitter FCC ID: FIH05716 IC: 1584A-05716 FOR TRANSCORE AMTECH TECHNOLOGY CENTER 8600 Jefferson Street, NE Albuquerque, NM 87113 Report Number 101001 Authorized Signatory: Scot D. Rogers NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID#: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: October 16, 2010 Revision 1 File: Transcore MPRR TstRpt 101001 Page 2 of 40 Test Report For Application of Certification For Transcore Amtech Technology Center 8600 Jefferson Street, NE Albuquerque, NM 87113 Phone: (505) 856-8101 Model: MPRR (MULTIPLE PROTOCOL RAILROAD RADIO) LMS Transmitter Frequency: 902.25 - 903.75 and 910.0 - 921.5 MHz FCC ID: FIH05716 IC: 1584A-05716 Test Date: October 1, 2010 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 W. 259th Terrace Louisburg, KS 66053 Telephone / Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID#: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: October 16, 2010 Revision 1 File: Transcore MPRR TstRpt 101001 Page 3 of 40 Table Of Contents TABLE OF CONTENTS .................................................................................................... 3 EXECUTIVE SUMMARY .................................................................................................. 6 Equipment Under Test ............................................................................................................................................. 6 OPINION / INTERPRETATION OF RESULTS ................................................................. 6 ENVIRONMENTAL CONDITIONS.................................................................................... 6 APPLICABLE STANDARDS AND TEST PROCEDURES ............................................... 7 LIST OF TEST EQUIPMENT ............................................................................................ 7 TEST SITE LOCATION .................................................................................................... 8 2.1033(C) APPLICATION FOR CERTIFICATION ............................................................ 9 2.1046 RF POWER OUTPUT ........................................................................................... 11 Measurements Required .......................................................................................................................................... 11 Test Arrangement ..................................................................................................................................................... 11 Figure One Power output at antenna terminal (ATA operation) ............................................................................ 12 Figure Two Power output at antenna terminal (modulated operation) ................................................................... 12 Results Output Power at Antenna Terminal .......................................................................................................... 13 2.1047 MODULATION CHARACTERISTICS ................................................................... 13 Measurements Required .......................................................................................................................................... 13 Test Arrangement ..................................................................................................................................................... 13 Results Modulation Characteristics ........................................................................................................................ 13 2.1049 OCCUPIED BANDWIDTH .................................................................................... 14 Measurements Required .......................................................................................................................................... 14 Test Arrangement ..................................................................................................................................................... 14 Results of Occupied Band Width............................................................................................................................. 14 NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID#: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: October 16, 2010 Revision 1 File: Transcore MPRR TstRpt 101001 Page 4 of 40 Figure Three Occupied Bandwidth 902.25 MHz (ATA) ....................................................................................... 15 Figure Four Occupied Bandwidth 921.50 MHz (ATA) ........................................................…
Text truncated - open the document above for the full version.
Rogers Labs, Inc. Transcore Amtech Technology Center SN: ENG1 4405 W. 259th Terrace Model: MPRR (Multiple Protocol Railroad Radio) FCC ID: FIH05716 Louisburg, KS 66053 Test #: 101001 IC: 1584A-05716 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 90 and RSS-137 Date: 10/16/2010 Revision 1 File: Short Term TSup MPRR Page 1 of 1 Test setup photographs
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 5 | 90.353 | 911.75 MHz - 919.75 MHz | 1.8 W | 381KL1D | 6 ppm |

Low Power Communication Device for use in Toll exchange applications
Equipment Class
DTS - Digital Transmission System
Low Power Communication Device for use in Toll exchange applications
Equipment Class
DTS - Digital Transmission System
Location and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Location and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station TransmitterLocation and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter