FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TransCore/
  3. FIHSPSBPT15V1

FIHSPSBPT15V1Low Power Communication Device for use in Toll exchange applications

TransCore
Low Power Communication Device for use in Toll exchange applications - FCC ID FIHSPSBPT15V1 - TransCore
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 27, 2026
Application Purpose
Original Equipment
Equipment Note
Low Power Communication Device for use in Toll exchange applications
Frequency Range
2402.00000000 - 2480.00000000
Company
TransCore
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

– SmartPass Lane Beacon & Signal Beacon User Guide 16-0205-003 Rev X1 08/2026 TransCore’s SmartPass Lane Beacon and SmartPass Signal Beacon work in conjunction with the SmartPass mobile application to reliably determine a vehicle’s lane of travel as it moves through a toll zone — supporting accurate transaction assignment and reducing reliance on traditional roadside hardware. Universal Bluetooth® Low Energy compatibility (BLE) allows for frictionless integration across mobile and Internet of Things (IoT) ecosystems. This guide provides site planning, installing, testing, and general operating instructions. This information is intended for use by authorized TransCore dealers, installers, and service personnel. SmartPass Lane Beacon & Signal Beacon User Guide ii TransCore Proprietary Information in this document is subject to change and does not represent a commitment on the part of TransCore, LP. © 2016-2026 TransCore, LP. All rights reserved. TRANSCORE, AMTECH, EGO, and ENCOMPASS are registered trademarks and are used under license. All other trademarks are the property of their respective owners. Contents are subject to change. Printed in the U.S.A. For further information, contact: TransCore 8600 Jefferson Street NE Albuquerque, New Mexico 87113 USA TransCore Technical Support Phone: (505) 856-8007Web: www.transcore.com TransCore Sales Support Phone: (800) 923-4824 TransCore Proprietary iii WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION (FCC) FCC RADIO FREQUENCY INTERFERENCE STATEMENT 47 CFR §15.105(A) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate RF energy and may cause harmful interference to radio communications if not installed and used in accordance with the instruction manual. Operating this equipment in a residential area is likely to cause harmful interference, in which case, depending on the laws in effect, the user may be required to correct the interference at their own expense. NO UNAUTHORIZED MODIFICATIONS 47 CFR §15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without permission. Unauthorized modification may void the equipment authorization from the FCC and will void the warranty. TRANSCORE, LP USA SmartPass Lane Beacon & Signal Beacon User Guide iv TransCore Proprietary AVERTISSEMENT À L’ATTENTION DES UTILISATEURS AUX ÉTATS-UNIS FEDERAL COMMUNICATIONS COMMISSION (FCC) DÉCLARATION 47 CFR §15.105(A) DE LA FCC SUR LES INTERFÉRENCES DES FRÉQUENCES RADIO REMARQUE : Cet appareil a été testé et déclaré conforme à la catégorie d’un appareil numérique de classe A en accord avec la partie 15 des directives de la FCC. Ces normes visent à assurer une protection raisonnable contre les interférences nuisibles lorsque l’appareil est utilisé dans un environnement commercial. Cet appareil génère, utilise et peut émettre de l’énergie RF et peut être à l’origine d’interférences nuisibles aux communications radio s’il n’est pas installé et utilisé en suivant les directives du manuel d’instructions. Si cet appareil est utilisé dans une zone résidentielle, il est probable qu’il cause des interférences nuisibles. Dans ce cas, l’utilisateur pourrait être amené à remédier aux interférences à ses propres frais, selon les lois du pays en vigueur. AUCUNE MODIFICATION NON AUTORISÉE 47 CFR §15.21 MISE EN GARDE : Il est interdit de modifier, d’altérer ou d’apporter des changements à cet appareil de quelque manière que ce soit sans autorisation. Toute modification non autorisée peut annuler l’autorisation d’utilisation accordée par la FCC et annulera la garantie. TRANSCORE, LP ÉTATS-UNI TransCore Proprietary v WARNING TO USERS IN CANADA This device contains licence-exempt transmitter(s)/receiver(s) that comply with Inovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. AVERTISSEMENT AUX UTILISATEURS AU CANADA Cet appareil contient des émetteurs(s)/récepteurs exemptés de licence qui sont conformes à l’EXEMPTION de RSS(s) d’Innovation, Science et Developpement économique Canada). L’ opération est soumise aux deux conditions suivantes: 1. l'appareil ne doit pas produire de brouillage. 2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. SmartPass Lane Beacon & Signal Beacon User Guide vi TransCore Proprietary RADIO FREQUENCY HEALTH LIMITS LIMITES D’EXPOSITION AUX RADIOFRÉQUENCES FCC (Federal Communication Commission) WARNING: The radiated output power of this device is below the FCC radio frequency exposure limits. Nevertheless, this device should be used in such a manner that the potential for human contact during normal operation is minimized. This device has been evaluated for and shown compliant with the FCC RF Exposure limits under mobile exposure conditions (antennas are greater than 20 cm from a person’s body). For details on device installation, please refer to the installation section in this user- manual. Industry Canada (Innovation, Science and Economic Development Canada) RF Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et util…

Text truncated - open the document above for the full version.

Cover Letter(s)

NVLAP Lab Code 200087-0 August 25, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Transcore (FRN # 0006083745) Regarding equipment: FCC ID: FIHSPSBPT15V1 FCC ID: FIHSPLBPT15V1 Subject: TransCore Authorized Signatures To Whom It May Concern: We, Rogers Labs, a division of The Compatibility Center LLC, as authorized agents, hereby authorize Duane Wrasman, Engineering Manager of TransCore, to sign documents for subject certifications on behalf of the official contact, Mr. Dale Scott, during his absence on temporary leave. Sincerely, Patrick Powell Co-Owner Rogers Labs, a Division of The Compatibility Center Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666

Cover Letter(s)

File: SmartPass Signal Beacon FCC Confidential Request Letter r2 Page 1 of 2 August 17, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Applicant: TransCore 8600 Jefferson St. NE Albuquerque, NM 87113 Device: FCC ID: FIHSPSBPT15V1 Trade Name: SmartPass Signal Beacon Model: SPSBV1 Re: Confidentiality for submittal on FCC ID: FIHSPSBPT15V1 Product: Transmitter operated under 47CFR Section 15 Dear Sirs: TransCore requests that the material in the Block Diagram, Theory of Operation, Parts List and Schematics be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. In support of this request, TransCore submits the following information. CONFIDENTIAL FILES SmartPass Signal Beacon Block Diagram.pdf SmartPass Signal Beacon Theory of Operation.pdf SmartPass Signal Beacon BOM.pdf SmartPass Signal Beacon Schematic.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Block Diagram, Theory of Operation, Parts List and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID: FIHSPSBPT15V1 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666 File: SmartPass Signal Beacon FCC Confidential Request Letter r2 Page 2 of 2 This material includes a detailed Block Diagram, Theory of Operation, Parts List and Schematics. As such, this material is treated as highly confidential business information. 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of TransCore’s engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to TransCore 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by TransCore and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry the protection sought is narrowly drawn as provided in regulations. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Best Regards, Patrick Powell Rogers Labs, a division of The Compatibility Center LLC

Cover Letter(s)

TRAf<JsCoRE Amtcd1 foclmol ogy Center m,oo /mforsnn Stmi)t NF AI/Ju q uer q ue. New /vlexico 87113 505.856.IWOO tel 505.857.0715 1;1., Monday, June 3, 2024 Federal Com munication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: Pursuant t o Title 47 CFR 2.911, TransCore-Amtech Technology Center has authorized Patrick Powell and Jeremy Cott of Rogers Labs, a division of The Compatibility Center LLC to act on TransCore-Amtech Technology Center behalf for t he sole and express purpose of processing application for equipment authorization. As such, Mr. Powell and Mr. Cott are authorized to sign forms, letters of application, request c onfidentiality, and exchange data and information relating to these matters and submittals. Rogers Labs, a division of The Compatibility Cent er LLC is authorized to receive and exchange data between our company and the authorizing agenc y. All acts carried out by Rogers Labs, a division of The Compatibility Center LLC on our behalf shall have the same effects as our own. For instances where our authorized agent signs the application for certification on behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by regulation still resides with TransCore-Amtech Technology Center. This Authorization is in effect until notified to the contrary by TransCore-Amtech Technology Center Dale Scott VP Engineering & Manufacturing TransCore-Amtech Technology Center

External Photos

Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 26, 2026 Revision 3 File: SmartPass Signal Beacon ExtPho r3 Page 1 of 4 Equipment photographs SPSBV1 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 26, 2026 Revision 3 File: SmartPass Signal Beacon ExtPho r3 Page 2 of 4 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 26, 2026 Revision 3 File: SmartPass Signal Beacon ExtPho r3 Page 3 of 4 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 26, 2026 Revision 3 File: SmartPass Signal Beacon ExtPho r3 Page 4 of 4

ID Label/Location Info

Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 17, 2026 Revision 2 File: SmartPass Signal Beacon LabelSmpl r2 Page 1 of 2 Label Placement Notes: Item 2 is the label (see drawing below) Item 3 is a clear overlay for protection of the label. Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A- SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 17, 2026 Revision 2 File: SmartPass Signal Beacon LabelSmpl r2 Page 2 of 2 Label Content

Internal Photos

Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 1 of 15 Internal photographs of SmartPass Signal Beacon SPSBV1 Transmitter 1 (Chip 1) Circuitry Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 2 of 15 Transmitter 2 (Chip 2) Circuitry Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 3 of 15 Transmitter Board Bottom (Antenna Array) Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 4 of 15 Transmitter Board Bottom (Antenna Array) Mark-up Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 5 of 15 Transmitter Board Top (BLE Transmitters and antenna feed) Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 6 of 15 Transmitter Board Top (BLE Transmitters and antenna feed)_Mark-up Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 7 of 15 Transmitter Circuitry (both transmitters) Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 8 of 15 Device housing Internal views without components Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 9 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 10 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 11 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 12 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 13 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 14 of 15 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Rd. FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 2 File: SmartPass Signal Beacon IntPho r2 Page 15 of 15

RF Exposure Info

NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 1.1307, RSS-102 Issue 6 Date: August 14, 2026 Revision 2 File: Transcore SmartPass Signal Beacon RFExp FCC-IC 260415A r2 Page 1 of 18 FCC / ISED RF Exposure Evaluation Report Model: SmartPass Signal Beacon FCC ID: FIHSPSBPT15V1 IC: 1584A-SPSBRSS247 2402-2480 MHz Transcore Amtech Technology Center 8600 Jefferson Street, NE Albuquerque, NM 87113 Test Report Number: 260415A Test Date: April 15, 2026 – May 27, 2026 Authorized Signatory: Patrick Powell Rogers Labs, a division of The Compatibility Center LLC FCC Designation Number: US5305 FCC Registration Number: 315994 ISED Company Number: 32275 ISED CAB Identifier: US0096 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666 NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 1.1307, RSS-102 Issue 6 Date: August 14, 2026 Revision 2 File: Transcore SmartPass Signal Beacon RFExp FCC-IC 260415A r2 Page 2 of 18 Table of Contents Table of Contents TABLE OF CONTENTS .................................................................................................. 2 REVISIONS ..................................................................................................................... 3 EXECUTIVE SUMMARY ................................................................................................ 4 Regulatory Requirements: .................................................................................................................................. 4 FCC: .................................................................................................................................................................... 4 Industry Canada: .................................................................................................................................................. 4 Applicant: ............................................................................................................................................................. 5 EUT details: .......................................................................................................................................................... 5 Names and IDs: ................................................................................................................................................... 5 Equipment Operational Modes: ........................................................................................................................... 5 Equipment & Accessory List ............................................................................................................................... 6 Equipment Configuration.................................................................................................................................... 7 Equipment Function ............................................................................................................................................ 8 TEST SITE LOCATIONS ................................................................................................ 9 ENVIRONMENTAL CONDITIONS.................................................................................. 9 TEST RESULTS ........................................................................................................... 10 Test Data: Chip 1, BLE ..................................................................................................................................... 10 Test Data: Chip 2, BLE ..................................................................................................................................... 11 Summary and Simultaneous Chip 1 and 2 Calculations ................................................................................. 12 Conclusion ........................................................................................................................................................... 13 ANNEX .......................................................................................................................... 14 Annex A Measurement Uncertainty Calculations ........................................................................................... 15 Annex B Test Equipment ................................................................................................................................... 16 Annex C Laboratory Certificate of Accreditation ........................................................................................... 18 NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 1.1307, RSS-102 Issue 6 Date: August 14, 2026 Revision 2 File: Transcore SmartPass Signal Beacon RFExp FCC-IC 260415A r2 Page 3 of 18 Revisions Revision 1 Issued July 22, 2026 – Initial Release Revision 2 Issued August 14, 2026 – Corrected IC ID# and showed exemption from routine evaluation. NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: Sma…

Text truncated - open the document above for the full version.

Test Report

NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 3 File: Transcore SmartPass Signal Beacon DTS TstRpt 260415A r3 Page 1 of 46 47CFR, PART 15C - Intentional Radiators 47CFR Paragraph 15.247 and Industry Canada RSS-247 Issue 4 and RSS-GEN Issue 5 Application For Grant of Certification Model: SmartPass Signal Beacon 2402-2480 MHz Digital Transmission System (DTS) FCC ID: FIHSPSBPT15V1 IC: 1584A-SPSBRSS247 Transcore Amtech Technology Center 8600 Jefferson Street, NE Albuquerque, NM 87113 Test Report Number: 260415A Test Date: April 15, 2026 – May 27, 2026 Authorized Signatory: Patrick Powell Rogers Labs, a division of The Compatibility Center LLC FCC Designation Number: US5305 FCC Registration Number: 315994 ISED Company Number: 32275 ISED CAB Identifier: US0096 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666 NVLAP Lab Code 200087-0 Rogers Labs, a division of The Compatibility Center LLC Transcore 7915 Nieman Road FCC ID: FIHSPSBPT15V1 HVIN: SPSBV1 PMN: SmartPass Signal Beacon Lenexa, KS 66214 Test: 260415A IC: 1584A-SPSBRSS247 SN’s: 051205-01 Phone/Fax: (913) 660-0666 Test to: 47CFR 15C, RSS-Gen RSS-247 Date: August 14, 2026 Revision 3 File: Transcore SmartPass Signal Beacon DTS TstRpt 260415A r3 Page 2 of 46 Table of Contents Table of Contents TABLE OF CONTENTS .................................................................................................. 2 REVISIONS ..................................................................................................................... 4 EXECUTIVE SUMMARY ................................................................................................ 5 OPINION / INTERPRETATION OF RESULTS ............................................................... 6 EQUIPMENT TESTED .................................................................................................... 9 Equipment Operational Modes ........................................................................................................................... 9 Equipment Function .......................................................................................................................................... 10 Equipment Configuration.................................................................................................................................. 11 APPLICATION FOR CERTIFICATION ......................................................................... 12 ENVIRONMENTAL CONDITIONS............................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dale Scott(VP of Engineering and Manufacturing)
[email protected]Fax: (505) 856-8174

Technical Contact

TransCoreDale Scott
[email protected]

TransCore - Amtech Technology Center · Albuquerque, New Mexico, 87113 · United States

Test Firm

Rogers Labs, a division of The Compatibility CntrPatrick Powell
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz31.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum combined conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance requirements.

Other Applications from TransCore

Low Power Communication Device for use in Toll exchange applications - FCC ID FIHSPLBPT15V1 - TransCore
FIHSPLBPT15V1

Low Power Communication Device for use in Toll exchange applications

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
Location and Monitoring Service Interrogator - FCC ID FIHE4FPT90V1 - TransCore
FIHE4FPT90V1

Location and Monitoring Service Interrogator

Sep 04, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Location and Monitoring Service Interrogator - FCC ID FIHE6PT90V2 - TransCore
FIHE6PT90V2

Location and Monitoring Service Interrogator

Jan 24, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
FIHE4SPT90V5

Location and Monitoring Service Interrogator

Jun 02, 2022

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Location and Monitoring Service Interrogator - FCC ID FIHE6PT90V1 - TransCore
FIHE6PT90V1

Location and Monitoring Service Interrogator

Feb 18, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter