FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TransCore/
  3. FIH22000555201

FIH22000555201LMS Transmitter

TransCore
LMS Transmitter - FCC ID FIH22000555201 - TransCore
Click to zoom

Application Details

Equipment Class
LMS - Part 90 Location & Monitoring Transmitter
Date of Grant
Apr 13, 2003
Application Purpose
Original Equipment
Date of Application
Apr 13, 2003
Equipment Note
LMS Transmitter
Frequency Range
910.00000000 - 921.50000000
Company
TransCore
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TransCore Inc. 19111 Dallas Parkway, Suite 300 Dallas, Texas 75287-3106 March 2003 P/N 411052-003 AR2200 RF Module User Guide Information in this document is subject to change and does not represent a commitment on the part of TC IP, Ltd. © 2003 TC IP, Ltd. All rights reserved. TRANSCORE is a trademark and Amtech is a registered trademark of TC IP, Ltd. and is used under license. All other trademarks listed are the property of their respective owners. Contents subject to change. Printed in the U.S.A. For further information, contact: TransCore 19111 Dallas Parkway, Suite 300 Dallas, Texas 75287-3106 USA Phone:(972) 733-6600 Fax:(972) 733-6699 TransCore Action Center (TrAC) 19111 Dallas Parkway, Suite 300 Dallas, Texas 75287-3106 USA Phone:(800) 755-0378 Fax:(972) 733-6695 WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY INTERFERENCE STATEMENT 47 CFR §15.105(a) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency (RF) energy and may cause harmful interference to radio communications if not installed and used in accordance with the instruction manual. Operating this equipment in a residential area is likely to cause harmful interference, in which case, depending on the laws in effect, the users may be required to correct the interference at their own expense. NO UNAUTHORIZED MODIFICATIONS 47 CFR §15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without permission from TransCore, Inc. Unauthorized modification may void the equipment authorization from the FCC and will void the TransCore warranty. USE OF SHIELDED CABLES IS REQUIRED 47 CFR §15.27(a) Shielded cables must be used with this equipment to comply with FCC regulations. A license issued by the FCC is required to operate this RF identification device in the United States. Contact TransCore, Inc. for additional information concerning licensing requirements for specific devices. TransCore, Inc. USA Contents vii Contents 1 Before You Begin Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Guide Topics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Health Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 2 AR2200 RF Module Overview Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Range Sensitivity Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 ISO Compatible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Patented Design: High-Speed Signal Capture, Noise Immunity. . . . . . . . . . . . . 2-5 Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Preamplifier Line Driver Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Circuit Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 International Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Output Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Harsh Environment Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Custom Frequencies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Replacement I/O Interface Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Hex Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Weatherproof Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 3 Installing the AR2200 RF Module AR2200 RF Module Installation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Differences in Installation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 AI1200 Reader Power Supply Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Configuring the RF Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Required Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Positioning the RF Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidential Treatment - Amtech Technologies Center FCC ID No: FIH22000555201 Transcore requests that the materials in the Exhibits be withheld from public disclosure in accordance with Section 0.457 and 0.459 of the Commission’s Rules, 47 C.F.R., following grant of the application. In support of this request, Transcore submits the following: (1) identification of the specific information for which confidential treatment is sought: The material “block diagram, schematics(10515,10516,10517&10519), parts list (6515,6516,6517 & 6519) and operational description (17090,17091,17093 & 17096)” in the Exhibits, which are segregated from the non-confidential exhibits of the application, is that for which confidentiality is sought. (2) identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: FIH22000555201 (3) explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes circuit diagrams (schematics and blocks) and other technical details (theory of operation and certain manufacturing details as to how the equipment is adjusted during the course of manufacture). As such, this material is treated as highly confidential. (4) explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of Location and Monitoring Service transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources of supply. (5) explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Transcore’s engineering personnel, who have designed the equipment and the manufacturing processes. Disclosure would also offer competitors additional unwarranted insight into the state of product development thereby allowing such competitors an advantage that would not be available to Transcore. (6) identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Transcore and not made available to third parties except pursuant to non-disclosure agreements. (7) identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this non-multilateration equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings at the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of modulated backscatter radio technology. (8) justification of the period during which the submitting party asserts that material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both designs and manufacturing techniques and could have an adverse competitive effect for many years to come. This equipment is designed for commercial, industrial, and governmental transportation applications. As such, unlike most consumer equipment, it is expected to be used for more than a decade in some cases. Moreover, this equipment will be used in revenue collection (e.g. toll collections) and secure access control applications (e.g. freight handling facilities). As such, it is important that its design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. (9) any other information that the party seeking confidential treatment believes may be useful in assessing whether its request for confidentiality should be granted: See item 8 above. Note that the equipment for which approval is being sought will be employed in applications that inherently carry a premium on security. Richard Nygren Quality/Regulatory Engineer Amtech Technology Center Tel: (505) 856-8101 FAX: (505) 856-8174 [email protected]

Cover Letter(s)

March 13, 2003 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Federal Communications Commission Equipment Approval Services P.O. Box 35815 Pittsburgh, PA 15251-3315 Applicant: Transcore Amtech Technology Center 8600 Jefferson Street NE Albuquerque, New Mexico 87113 505 856-8000 Telephone 505 857-0715 Fax Equipment: FCC ID: FIH 22000555201 FCC Rules: Part 2 and 90 Gentlemen: The 731 form and application have been electronically submitted and any attachments will be up loaded to your web page site to be used in obtaining a grant of certification. It is requested that the information contained in the block diagram, operational description, documents marked as confidential, and schematics of the application be held confidential per Section 0.459. A statement of confidentiality will be attached with the application at the time of submittal. The special fee for request of confidentiality will be submitted with the application. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214

External Photos

ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 1 of 2 AR2200Photos.doc 3/13/2003 Equipment photographs for AR2200/05552-01. ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 2 of 2 AR2200Photos.doc 3/13/2003

Internal Photos

ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 1 of 3 AR2200IntPho.doc 3/13/2003 Internal photographs of AR2200/05552-01. ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 2 of 3 AR2200IntPho.doc 3/13/2003 ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 3 of 3 AR2200IntPho.doc 3/13/2003 Note there are no components located on printed circuit board sides not show in these photographs.

Parts List/Tune Up Info

ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 1 of 3 AR2200Tune.doc 3/22/2003 The procedures for tuning the unit are described in the operational description for the AR2200/05552-01.

Test Report

MPE Calculator MPE uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi. dBi = dB gain compared to an isotropic radiator. S = power density in mW/cm^2Antenna Gain (dBi)14 Output PowerdBd + 2.17 = dBidBi to dBd2.17 Tx Frequency (MHz)902(Watts)1.7800Antenna Gain (dBd)11.83 Cable Loss (dB)3.0(dBm)32.50Antenna minus cable (dBi)11.00 Calculated ERP (mw)13596.277EIRP = Po(dBM) + Gain (dB) Calculated EIRP (mw)22408.872Radiated (EIRP) dBm43.504 ERP = EIRP - 2.17 dB Occupational LimitRadiated (ERP) dBm41.334 3.00667 mW/cm 2 General Public Limit 0.60133 mW/cm 2 Frequency (MHz)Occupational LimitPublic Limit 300-1,500f/300f/1500 1,500-10,00051 Frequency (MHz) Occupational Limit @ Tx Freq (mW/cm^2) Public Limit @ Tx Freq (mW/cm^2) 300-1,5003.0066666670.601333333 1,500-10,00051 EIRPDistanceDistanceS milliwattscminchesmW/cm 2 22408.872250.0098.430.02853 22408.872200.0078.740.04458 22408.872150.0059.060.07926 22408.872100.0039.370.17832 22408.87275.0029.530.31702 22408.87255.0021.650.58950 22408.87250.0019.690.71330 22408.87245.0017.720.88061 22408.87243.0016.930.96444 22408.87240.0015.751.11453 22408.87225.009.842.85319 22408.87224.759.742.91112 22408.87224.509.652.97083 22408.87224.259.553.03240 22408.87224.009.453.09591 22408.87220.007.874.45810 22408.87219.757.784.57168 22408.87219.507.684.68966 22408.87219.257.584.81226 22408.87219.007.484.93973 22408.87218.757.385.07233 22408.87218.507.285.21035 22408.87218.257.195.35407 22408.87218.007.095.50383 22408.87217.756.995.65996 22408.87217.506.895.82283 22408.87217.256.795.99283 22408.87217.006.696.17039 22408.87216.756.596.35595 22408.87216.506.506.55001 22408.87216.256.406.75310 Frequency (MHz) Occupational Limit minimum Distance (cm) Public Limit minimum distance (cm) 300-1,50024.2555.00 1,500-10,000N/AN/A FCC radio frequency radiation exposure limits per 1.1310 FCC radio frequency radiation exposure limits per 1.1310 Power density (S) EIRP ------- = mW/cm^2 4 p r^2 r (cm) EIRP (mW)

Test Report

ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 15 and 90 Page 1 of 3 AR2200Conducted Emissions.DOC 03/12/2003 Conducted EMI The EUT was arranged in a typical equipment configuration and placed on a 1 x 1.5-meter wooden bench 80 cm above the conducting ground plane, floor of a screen room. The bench was positioned 40 cm away from the wall of the screen room. The LISN was positioned on the floor of the screen room 80-cm from the rear of the EUT. The power cord of the EUT was connected to the LISN. EMI was coupled to the spectrum analyzer through a 0.1 μF capacitor, internal to the LISN. Power line conducted emissions testing was carried out individually for each current carrying conductor of the EUT. The excess length of lead between the system and the LISN receptacle was folded back and forth to form a bundle not exceeding 40 cm in length. The screen room, conducting ground plane, analyzer, and LISN were bonded together to the protective earth ground. Preliminary testing was performed to identify the frequencies of the emissions, which had the highest amplitudes. The cables were repositioned to obtain maximum amplitude of measured EMI level. Once the worst-case configuration was identified, plots were made of the EMI from 0.15 MHz to 30 MHz then the data was recorded with maximum conducted emissions levels. Refer to Figures 1 and 2 for plots of the spectrum analyzer display reflecting the conducted emissions. ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 15 and 90 Page 2 of 3 AR2200Conducted Emissions.DOC 03/12/2003 Figure one Line Conducted Emissions for (L1). Figure two Line Conducted Emissions for (L2). ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2, 15 and 90 Page 3 of 3 AR2200Conducted Emissions.DOC 03/12/2003 Conducted (6 Highest Emissions) Frequency band (MHz) L1 Level (dBμV) Peak Q.P. AVE L2 Level (dBμV) Peak Q.P. AVE FCC Limit Quasi Peak (dBμV) 0.15 - 0.5 41.4 40.3 40.0 41.8 41.0 40.8 -- 0.5 – 5 28.6 26.7 25.1 29.5 26.8 25.4 48 5 – 10 23.3 18.8 14.8 18.4 14.2 8.0 48 10 – 15 37.1 35.9 35.0 38.1 37.0 34.3 48 15 – 20 46.3 45.1 43.2 48.0 46.5 44.3 48 20 – 25 38.0 36.3 35.0 47.9 47.1 45.5 48 25 - 30 35.5 33.1 28.8 34.6 31.8 27.0 48 Other emissions present had amplitudes at least 10 dB below the limit. Conducted Emissions Results The conducted emissions for the EUT meet the requirements for FCC Part 15.207. The AR 2200 had a 15 dB minimum margin below the FCC quasi-peak limit. Other emissions were present with amplitudes at least 10.0 dB below the limit.

Test Report

Test Report For Application of Certification For TRANSCORE AMTECH TECHNOLOGY CENTER 8600 Jefferson Street, NE Albuquerque, NM 87113 Phone: (505) 856-8101 MODEL: AR 2200/05552-01 LMS Transmitter FREQUENCY: 902-928 MHz FCC ID: FIH 22000555201 Test Date: February 6, 2003 Certifying Engineer: Scot D. Rogers ROGERS LABS, INC. 4405 W. 259th Terrace Louisburg, KS 66053 Phone: (913) 837-3214 FAX: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 2 of 23 AR2200TsTRpt.DOC 02/06/2003 TABLE OF CONTENTS FORWARD: 3 LIST OF TEST EQUIPMENT 3 2.1033(C) APPLICATION FOR CERTIFICATION 4 2.1046 RF POWER OUTPUT 7 Measurements Required: 7 Test Arrangement: 7 Results: 7 2.1047 MODULATION CHARACTERISTICS 9 Measurements Required: 9 Test Arrangement: 9 Results: 10 2.1049 OCCUPIED BANDWIDTH 10 Measurements Required: 10 Test Arrangement: 10 Results: 10 2.1051 SPURIOUS EMISSIONS AT ANTENNA TERMINALS 11 Measurements Required: 11 Test Arrangement: 11 Results: 14 2.1053 FIELD STRENGTH OF SPURIOUS RADIATION 14 Measurements Required: 14 Test Arrangement: 15 Results: 16 Radiated (6 Highest Emissions General Emissions) 17 2.1055 FREQUENCY STABILITY 17 Measurements Required: 17 Test Arrangement: 18 Results: 19 APPENDIX 20 NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 3 of 23 AR2200TsTRpt.DOC 02/06/2003 FORWARD: In accordance with the Federal Communications Code of Federal Regulations, dated October 1, 2001, Part 2 Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926, 2.1031 through 2.1057; 90.201 through 90.217, 90.350 through 90.363 the following is submitted: List of Test Equipment A Hewlett Packard 8591EM and or 8562A Spectrum Analyzer was used as the measuring device for the emissions testing. The analyzer settings used are described in the following table. Refer to the appendix for a complete list of Test Equipment. HP 8591EM SPECTRUM ANALYZER SETTINGS CONDUCTED EMISSIONS: RBW AVG. BW DETECTOR FUNCTION 9 kHz 30 kHz Peak/Quasi Peak RADIATED EMISSIONS (30 - 1000 MHz): RBW AVG. BW DETECTOR FUNCTION 120 kHz 300 kHz Peak/Quasi Peak HP 8562A SPECTRUM ANALYZER SETTINGS RADIATED EMISSIONS (1 - 40 GHz): RBW AVG. BW DETECTOR FUNCTION 1 MHz 1 MHz Peak/Average ANTENNA CONDUCTED EMISSIONS: RBW AVG. BW DETECTOR FUNCTION 100 kHz 300 kHz Peak NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 4 of 23 AR2200TsTRpt.DOC 02/06/2003 2.1033(c) Application for Certification 1. Manufacturer: TRANSCORE AMTECH TECHNOLOGY CENTER 8600 Jefferson Street, NE Albuquerque, NM 87113 2. Identification: Model: AR 2200/05552-01 FCC I.D.: FIH 22000555201 3. A copy of the installation and operating instructions furnished to the end user. Refer to the instruction manual furnished with this application for details. 4. Emission Type: Continuous wave (CW) Continuous Wave Emission Designator. NON 5. Frequency Range: 902 – 928 MHz 6. Range of operating power values or specific operating power levels, and description of any means provided for variation of operating power. The output power is factory set to 1.6 Watt (nominal). The EUT has provision for the operator to reduce the output power up to 7 dB. 7. Maximum power rating as defined in the applicable part(s) of the rules. As stated in CFR 47, 90.205(j), the maximum permissible output power allowed is 30 watts. 8. The dc voltages applied to and dc currents into the several elements of the final radio frequency amplifying device for normal operation over the power range. The EUT final amplification stage runs at 12.0 volts with 500 mA current for a power requirement of 6.0 W. NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. TransCore Amtech Technology Center 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH 22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 5 of 23 AR2200TsTRpt.DOC 02/06/2003 9. Provide the tune-up procedure over the power range, or at specific operating power levels. Refer to the tune-up procedure furnished with this application for details. 10. A schematic diagram and a description of all circuitry and devices provided for determining and stabilizing frequency, for suppression of spurious radiation, for limiting modulation, and for limiting power. Refer to the schematics furnished with this application for details. 11. A photograph or drawing of the equipment identification plate, or label showing the information to be placed thereon shall be provided. Refer to the FCC identification label information furnished with this application for details. 12. Photographs (8'' x 10'') of the equipment of sufficient clarity to reveal equipment construction and layout, including meters, if any, and labels for controls and meters and sufficient views of the internal construction to define component placement and chassis assembly. Insofar as these requirements are met by photographs or drawings contained in instruction manuals supplied with the certification request, additional photographs are necessary only to complete the required showing. Refer to the …

Text truncated - open the document above for the full version.

Test Setup Photos

ROGERS LABS, INC. TRANSCORE AMTECH TECHNOLOGY CENTER 4405 W. 259th Terrace MODEL: AR2200/05552-01 Louisburg, KS 66053 Test #: 030120 FCC ID#: FIH AR22000555201 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 90 Page 1 of 1 AR2200TstPhot.doc 3/12/2003 Test setup photographs for AR2200/05552-01.

Contact Information

Applicant

Dale Scott(VP of Engineering and Manufacturing)
[email protected]505 856-8178Fax: (505) 856-8174

Test Firm

Rogers Labs, Inc.Scot Rogers
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
290.353910 MHz - 921.5 MHz1.8 WNON1 ppm
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna gain should not exceed 14 dBi. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 55 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from TransCore

Low Power Communication Device for use in Toll exchange applications - FCC ID FIHSPSBPT15V1 - TransCore
FIHSPSBPT15V1

Low Power Communication Device for use in Toll exchange applications

Aug 27, 2026

Equipment Class

DTS - Digital Transmission System
Low Power Communication Device for use in Toll exchange applications - FCC ID FIHSPLBPT15V1 - TransCore
FIHSPLBPT15V1

Low Power Communication Device for use in Toll exchange applications

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
Location and Monitoring Service Interrogator - FCC ID FIHE4FPT90V1 - TransCore
FIHE4FPT90V1

Location and Monitoring Service Interrogator

Sep 04, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Location and Monitoring Service Interrogator - FCC ID FIHE6PT90V2 - TransCore
FIHE6PT90V2

Location and Monitoring Service Interrogator

Jan 24, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
FIHE4SPT90V5

Location and Monitoring Service Interrogator

Jun 02, 2022

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter