Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MPI 6000 Multi-Protocol Reader System Guide TransCore 8600 Jefferson Street NE Albuquerque, New Mexico 87113 P/N 411880 PRELIMINARY PRELIMINARY © 2005 TC IP, Ltd. All rights reserved. TRANSCORE, AMTECH, and EGO are registered trademarks of TC IP, Ltd, and are used under license. All other trademarks listed are the property of their respective owners. Contents are subject to change. Printed in the U.S.A. For further information, contact: Tr ansCore 8600 Jefferson Street NE Albuquerque, New Mexico 87113 USA Phone: (505) 856-8007 Fax:(505) 856-8174 . PRELIMINARY WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION (FCC) LOCATION AND MONITORING SERVICE STATEMENT 47 CFR §90.351 NOTE: The user is required to obtain a Part 90 site license from the FCC to operate this radio frequency identification (RFID) device in the United States and Canada. FCC ID number is FIHMPI6000A. IC ID number is 1584A-MPI6000A. Access the FCC Web site at www.fcc.gov/Forms/Form601/601.html or at wireless.fcc.gov/index.htm?job=online_filing to obtain additional information concerning licensing requirements. NOTE: Users in all countries should check with the appropriate local authorities for licensing requirements. FCC RADIO FREQUENCY INTERFERENCE STATEMENT 47 CFR §15.105(a) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate RF energy and may cause harmful interference to radio communications if not installed and used in accordance with the instruction manual. Operating this equipment in a residential area is likely to cause harmful interference, in which case, depending on the regulations in effect, the user may be required to correct the interference at their own expense. NO UNAUTHORIZED MODIFICATIONS 47 CFR §15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without permission from TransCore, LP. Unauthorized modification may void the equipment authorization from the FCC and will void the TransCore warranty. USE OF SHIELDED CABLES IS REQUIRED 47 CFR §15.27(a) NOTE: Shielded cables and earth grounding the unit is recommended for this equipment to comply with FCC regulations. TransCore, LP USA PRELIMINARY Health Limits for Encompass ® Multiprotocol Reader Using External Antenna (902 to 921.5 MHz) Within the United States, environmental guidelines regulating safe exposure levels are issued by the Occu- pational Safety and Health Administration (OSHA). Section 1910.97 of OSHA Safety and Health Standards 2206 legislates a maximum safe exposure limit of 10 milliwatts per square centimeter (mW/cm 2 ) averaged over 6 minutes at 902 MHz. Although not binding, other organizations such as the American National Standards Institute (ANSI) have issued similar guidelines that are more restrictive than the OSHA limits (ANSI C95.1). ANSI guidelines recommend a maximum safe power density in mW/cm 2 of: Frequency (in MHz) 1500 Thus, the maximum permissible exposure for general population/uncontrolled exposure at 902 MHz is 0.60 mW/cm 2 . The average time is thirty minutes. The maximum permissible exposure for occupational/controlled exposures is 3.0 mW/cm 2 . The average time is six minutes. The RF power density generated by the Encompass Multiprotocol Reader was calculated using a maxi- mum antenna gain of 14.0 dBi, equivalent to the antenna gain of the external AA3152 Universal Toll Antenna (UTA). Warning At 2 W transmitted power, 0 dB transmit attenuation, and a distance of 33 inches (82 cm) from the antenna, the maximum power density calculated was less than 0.60 mW/cm 2 . Install the antenna at least 33 inches (82 cm) from the general public. Maintenance personnel must remain at least 15 inches (37 cm) from the antenna when the system is operating. The data confirms that when the UTA, or equivalent antenna, is used with the TransCore Encompass Multiprotocol Reader, the antenna effectively meets OSHA requirements and thus does not represent an operating hazard to either the general public or maintenance personnel. PRELIMINARY Contents PRELIMINARY PRELIMINARY ix Contents Health Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v RF Levels From TransCore Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v 1 Before You Begin Purpose of the Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Guide Topics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Typographical Conventions Used in this Manual . . . . . . . . . . . . . . . . . . . . . . . 1-4 Licensing Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 U.S. and Canada Licensing . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 2 Developing the Installation Site Plan 3 Installing and Configuring the MPI 6000 Overview of the MPI 6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Connecting the MPI 6000 for Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 External Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Installing and Using the MPI 6000 Host Software . . . . . . . . . . . . . . . . . . . . . . . 3-6 Installing the Host Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Connectin…
Text truncated - open the document above for the full version.
March 4, 2013 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Applicant: Transcore - Amtech Technology Center 8600 Jefferson Street NE Albuquerque, New Mexico 87113 Re: Confidentiality for submittal information regarding FCC ID number FIHMPI6000A Product: Licensed Transmitter operating under part 90 Dear Sirs: Transcore Amtech Technology Center requests that the material in the Parts List, Schematics, Block Diagram, and Operational Description be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. In support of this request, Transcore Amtech Technology Center submits the following information. CONFIDENTIAL FILES Block Diagram Conf BlkDia MPI6000A.pdf Operational Description Conf OpDes MPI6000A.pdf Schematics Conf Schem MPI6000A.pdf Parts List Conf PartList MPI6000A.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Operational Description, block diagram, parts list, and Schematics, which are segregated, from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: FIHMPI6000A 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, and schematic. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Transcore Amtech Technology Center engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Transcore Amtech Technology Center. 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Transcore Amtech Technology Center and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. This equipment is designed for commercial, industrial, and governmental applications. As such, unlike most consumer equipment, this equipment could be used for more than a decade in some cases. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers
March 4, 2013 Timco Engineering Inc. Federal Communications Commission 849 NW State Road 45 Equipment Approval Services Newberry, FL 32669 Pittsburgh, PA 15251-3315 Applicant: Transcore - Amtech Technology Center 8600 Jefferson Street NE Albuquerque, New Mexico 87113 Equipment: FCC ID: FIHMPI6000A FCC Rules: Part 2 and 90 Sirs The form 731 and application have been electronically submitted and attachments up loaded to your site for use in processing for grant of certification. Confidentiality is requested as outlined below. Permanent Transcore Amtech Technology Center requests that the material in the Parts List, Schematics, block diagram, and Operational Description be withheld from public disclosure in accordance with Section 0.459 of the Commission’s Rules, CFR47 0.459, following grant of the application. It is requested that the information contained in the operational description, block diagram, parts list, internal photographs, and schematics of the application be held confidential per Section 0.459. A statement of confidentiality will be attached with the application at the time of submittal. Block Diagram Conf BlkDia MPI6000A.pdf Operational Description Conf OpDes MPI6000A.pdf Schematics Conf Schem MPI6000A.pdf Parts List Conf PartList MPI6000A.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone / Facsimile (913) 837-3214
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: ExtPho MPI6000A Page 1 of 2 Equipment photographs Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: ExtPho MPI6000A Page 2 of 2
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: LabelSmpl MPI6000A Page 1 of 1 Label Sample and Placement Label Placement E5 or E6 label placement
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: IntPho MPI6000A Page 1 of 1 Internal photographs
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: TunPro MPI6000A Page 1 of 1 Tune-up Procedure The design offers no adjustments to end users. Each device is tuned and tested during production. Product found in compliance with acceptable pass/fail parameters continue through production. Samples failing criteria are removed from production. The pass/fail threshold is determined by engineering during product development.
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: RFExp MPI6000A Page 1 of 1 M
NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 7, 2013 Revision 1 File: Transcore MPI6000A TstRpt 130210 Page 1 of 37 Test Report CFR47 Part 90 and Industry Canada RSS-137 Application for Grant of Certification Models: E5, E6 Location and Monitoring Service Transmitter 902.25 - 903.75 and 911.75 – 919.75 MHz FCC ID: FIHMPI6000A IC: 1584A-MPI6000A FOR TRANSCORE AMTECH TECHNOLOGY CENTER 8600 Jefferson Street, NE Albuquerque, NM 87113 Report Number 130210 Authorized Signatory: Scot D. Rogers NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 7, 2013 Revision 1 File: Transcore MPI6000A TstRpt 130210 Page 2 of 37 Test Report For Application of Certification For Transcore Amtech Technology Center 8600 Jefferson Street, NE Albuquerque, NM 87113 Phone: (505) 856-8101 Models: E5, E6 Location Monitoring Service Transmitter Frequency: 902.25 - 903.75 and 911.75 - 919.75 MHz FCC ID: FIHMPI6000A IC: 1584A-MPI6000A Test Date: February 10, 2013 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 W. 259th Terrace Louisburg, KS 66053 Telephone / Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code: 200087-0 Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 7, 2013 Revision 1 File: Transcore MPI6000A TstRpt 130210 Page 3 of 37 Table Of Contents TABLE OF CONTENTS .................................................................................................... 3 REVISION HISTORY ........................................................................................................ 4 EXECUTIVE SUMMARY .................................................................................................. 5 OPINION / INTERPRETATION OF RESULTS ................................................................. 5 APPLICATION FOR CERTIFICATION ............................................................................. 6 EQUIPMENT UNDER TEST ............................................................................................. 8 Test Setup Diagram .................................................................................................................................................. 8 APPLICABLE STANDARDS AND TEST PROCEDURES ............................................... 8 UNITS OF MEASUREMENTS .......................................................................................... 9 TEST SITE LOCATIONS .................................................................................................. 9 ENVIRONMENTAL CONDITIONS.................................................................................... 9 LIST OF TEST EQUIPMENT ............................................................................................ 10 TRANSMITTER POWER OUTPUT .................................................................................. 11 Measurements Required .......................................................................................................................................... 11 Test Arrangement ..................................................................................................................................................... 11 Table 1 Transmitter Power Results ......................................................................................................................... 12 Figure 1 Power output at antenna terminal (CW operation)................................................................................... 13 Figure 2 Power output at antenna terminal (Modulated operation) ........................................................................ 13 MODULATION CHARACTERISTICS ............................................................................... 14 Measurements Required .......................................................................................................................................... 14 Test Arrangement ..................................................................................................................................................... 14 Results Modulation Characteristics ........................................................................................................................ 14 OCCUPIED BANDWIDTH ................................................................................................ 15 Measurements Required .......................................................................................................................................... 15 Test Arrangement ..................................................................................................................................................... 15 Table 2 Occupied Bandwidth Results ..................................................................................................................... 15 Figure 3 Occupied Bandwidth 902.25 MHz (CW) ................................................................................................ 16 Figure 4 Occupied Bandwidth (SeGo operation) ...................................................................................…
Text truncated - open the document above for the full version.
Rogers Labs, Inc. Transcore Amtech Technology Center 4405 W. 259th Terrace Models: E5, E6 S/N: A3 FCC ID#: FIHMPI6000A Louisburg, KS 66053 Test #: 130210 IC: 1584A-MPI6000A Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 90 and RSS-137 Date: March 4, 2013 Revision 1 File: Short Term TSup MPI6000A Page 1 of 1 Test setup photographs
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 90.353 | 914.75 MHz - 916.75 MHz | 2 W | 2M82L1D | 2.5 ppm |

Low Power Communication Device for use in Toll exchange applications
Equipment Class
DTS - Digital Transmission System
Low Power Communication Device for use in Toll exchange applications
Equipment Class
DTS - Digital Transmission System
Location and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Location and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station TransmitterLocation and Monitoring Service Interrogator
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter