FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Compal Electronics Inc/
  3. GKRVT820

GKRVT820Tri-Mode Dual-Band Phone (AMPS/CDMA/ PCS CDMA)

Compal Electronics Inc
Tri-Mode Dual-Band Phone (AMPS/CDMA/ PCS CDMA) - FCC ID GKRVT820 - Compal Electronics Inc
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Sep 07, 2005
Application Purpose
Original Equipment
Date of Application
Sep 07, 2005
Equipment Note
Tri-Mode Dual-Band Phone (AMPS/CDMA/ PCS CDMA)
Frequency Range
824.04000000 - 848.97000000
Company
Compal Electronics Inc
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—
β†—
β†—

RF Exposure Info

β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 OPERATING MANUAL VT-820 Version 1.1 VACOM WIRELESS, INC. 2 CONTENTS IMPORTANT SAFETY INFORMATION GETTING TO KNOW YOUR PHONE DISPLAY INDICATORS BATTERY INFORMATION BASIC FUNCTIONS 1. Making Calls 2. Ending Calls 3. Answering Calls 4. Correcting Entry Errors 5. Storing Phone Numbers 6. Volume 7. Redialing Last Dialed, Received, or Missed Number 8. Speed Dial 9. Etiquette Mode 10. Silence Mode 11. Shortcut MENUS I. CALL INFORMATION 1. Call Function 2. Call Restrict 3. Call Answer 4. Call Time II. MY VIVO 1. Icon Order 2. Main Keys 3. Ring Types 3 4. Menu Format 5. Greeting 6. Wallpaper 7. Original Setting 8. SMS Setting 9. Auto CSP III. VOICE MAIL IV. MESSAGING 1. Chat 2. Messenger 3. E-Mail 4. SMS V. VOICE SERVICE 1. Voice Portal 2. Ring Back Tone 3. Vivo Information 4. Call Forward VI. UTILITY 1. Phone Book VII. GAMES 1. Built in Game 2. BREW Game VIII. ORTHER FUNCTION 1. Schedule 2. Alarm 3. Calculator 4. Voice Memo 5. Stop Watch 6. World Time 7. Memo 4 IX. SETTING 1. Back Light 2. Contrast 3. Language 4. Time Set 5. Security X. HELP 1. Call Center 2. International 3. Phone Information 4. Icons CAMERA WA P BREW CONTENT DOWNLOAD MESSAGE SERVICE USING MENU DURING CALLS 1. Phonebook Search 2. Tx Voice Mute 3. DTMF Mute 4. Voice Privacy 5. Beep Length 6. Speaker Phone ENTERING LETTERS & NUMBERS 1. Prediction Text Input 2. ABC/123 Mode 5 3. Inserting Punctuations & Special Characters FCC RF EXPOSURE INFORMATION 6 IMPORTANT SAFETY INFORMATION Some of the following information may not apply specifically to your phone. However, as with any electronic product, these safety precautions should be observed when using this product. β—ˆ Please keep this manual in a safe place, for it contains important safety information and operating instructions. β—ˆ Please follow and adhere to all warning, safety, and operating instructions indicated on both the phone and in this manual before use. β—ˆ Do Not expose the phone to water or moisture. β—ˆ Do Not expose the phone to extreme heat or cold. β—ˆ Do Not expose the phone to open flame. β—ˆ Do Not allow objects to fall or liquids to spill on the product. β—ˆ Use Original Accessories only. Any damage incurred from the use of non-approved accessories will void the warranty. β—ˆ Use approved chargers only and connect to a power source designated on the product. β—ˆ To reduce the risk of injury, remove the electrical cord from an outlet by pulling on the charger, rather than the cord. β—ˆ Ensure that the electrical cord is positioned accordingly so that it will not be vulnerable to damage. β—ˆ To reduce the risk of electrical shock, unplug the phone from the power source before cleaning. Once unplugged, use a soft cloth dampened with water to clean. β—ˆ DANGER: Do Not modify the cord or the plug. If the plug does not fit into an outlet, have a proper outlet installed by a qualified electrician. Improper connection can result in electrical shock. β—ˆ Do Not attempt to disassemble the product – doing so will void the warranty. This product does not contain consumer-serviceable components. Service should be performed only by authorized service centers. β—ˆ Do Not remove the antenna. A detached antenna can be a choking hazard for children. β—ˆ Do Not place the battery inside the mouth. The battery contains toxic electrolytes that are harmful for your health. 7 User Guide Proprietary Notice CDMA Technology is licensed by QUALCOMM Incorporated under one of more of the following patents: 4,901,307 5,109,390 5,267,262 5,416,797 5,506,865 5,544,196 5,657,420 5,101,501 5,267,261 5,414,796 5,504,773 5,535,239 5,600,754 5,778,338 5,228,054 5,337,338 5,710,784 5,056,109 5,568,483 5,659,569 5,490,165 5,511,073 8 GETTING TO KNOW YOUR PHONE Volume/Scroll Key These keys are used to set volume levels, and to help you navigate through menus and the Phonebook. Use the volume keys to: - Adjust call volume. - Adjust key tone volume. - Answer incoming calls. - Scroll through menu options. - Scroll through the Phonebook. Color LCD Display The LCD screen is divided into two sections: - The top line displays your phone status indicators. - The lower portion displays currently in-use information, such as Caller ID (if available), Mute, Call Waiting, etc. Menus are also displayed in the lower portion. Menu Keys ( /) These keys perform several useful functions: - Use these keys to answer incoming calls. - Use these keys from Standby mode to briefly access Main and Select menus. - Use these keys to select a highlighted selection when navigating through a menu. SMS Key From Standby mode, press this key to access a text message menu items. Navigation Keys These keys allow you to navigate the phone’s various features and useful shortcuts including Download, WAP, Torpedo, Audio and video etc. WA P ( β–Ό ) Key From Standby mode, press and hold this key to access a WAP. Then you can access Internet with your phone. BREW (β–²) Key From Standby mode, press this key to download and search contents. Then you can access server with your phone. Microphone Your typical conversational microphone. Mute the microphone during conversation by pressing β€œMENU” β€œ2”. Accessory Port Connect your charger here. CLR Key 9 This key is used to erase incorrect numeric or character entries or to return to a previous screen. - To erase a single character from the screen, briefly press the CLR key once. - To erase the entire entry field, hold down the CLR key for one second. - To back up one menu level, press the CLR key once. - To return to standby, hold the CLR key for one second. END Key Press this key to end calls or to return to Standby mode from any menu. Press and hold to turn the phone On or Off. SEND Key This key performs several useful functions: - Press the Send key to dial an entered number. - Press the Send key once to redial the last outgoing number. Numeric Keypad These keys are used to input numbers and characters. β—€ * This key performs several useful functions: - Toggle between ring and vibrate. - Use as a navigation key. # β–Ά This key perf…

Text truncated - open the document above for the full version.

Cover Letter(s)

Sincerely, Andy Suen Senior Director COMPAL ELECTRONICS, INC. Tel : +886-2-8797 8599 Fax : +886-2-8751 3808 Email: [email protected] GKRVT820 ) Sincerely, Andy Suen Senior Director COMPAL ELECTRONICS, INC. Tel : +886-2-8797 8599 Fax : +886-2-8751 3808 Email: [email protected] GKRVT820 GKRVT820 )

Cover Letter(s)

1 Mike Kuo From: Claire Hoque Sent: Thursday, September 08, 2005 11:01 AM To: Mike Kuo Cc: Kathy Yao Subject: answer: COMPAL ELECTRONICS, INC., FCC ID: GKRVT820, Assessment NO.: AN05T5107, Notice#1 Importance: High Attachments: Vt820 Technical Description -revised.pdf; VT820 Tune-Up Procedure -revised.pdf; FCC ID LABEL(revised).pdf Vt820 Technical Description -r... VT820 Tune-Up Procedure -revis... FCC ID BEL(revised).pdf (75 Hi Mike, Here are the answers. Q1: The proposed FCC ID only contains reference of part 22 but this device is a Part 22/24. Please make necessary changes. <answer>FCC label is revised as attached. Q2: Based upon the technical description file, the rated ERP and EIRP for AMPS / CDMA and PCS are : AMPS:400mW; CDMA:200mW ; PCS-CDMA:200mW; Based upon the Part 22/24 EMC test report, the max. measured output power are : AMPS:309mW; CDMA:676mW; PCS-CDMA:871mW. Please explain the differences between the specified power and measured output power. <answer> The power level in the technical description is revised. See the attachement. Q3: The conducted output power reported during the SAR tests are based upon average reading. In the tune up procedures, there are information provided to setup the device but there is no information to show what will be the factory target output power will be used for each of device.Please provide the max. average output power that factory will be tuned to for AMPS/CDMA and PCS-CDMA. <answer> Power will be tuned at Max. Average Output Power of AMPS:26dBm +/-1 dBm; CDMA:23dBm +/-1 dBm; PCS-CDMA:23dBm +/-1 dBm. Pls see revised Tune-up procedure. Client wishes to get grant TODAY, pls kindly help. Thanks, Claire

ID Label/Location Info

PROPOSED FCC ID LABEL AND LOCATION COMPAL ELECTRONICS, INC. This device complies with Part 22/24 of the FCC Rules. FCC ID: GKRVT820 FCC ID LABEL LOCATION

RF Exposure Info

IN ACCORDANCE WITH THE REQUIREMENTS OF FCC Report and Order: ET Docket 93-62 and OET Bulletin 65 Supplement C and RSS-102 Issue 1 (Provisional) September 25, 1999 FOR Dual Band Tri-Mode AMPS/CDMA Cellular and PCS Phone MODEL: VT820 FCC ID: GKRVT820 REPORT NUMBER: 05I3576-3 ISSUE DATE: August 23, 2005 Prepared for Compal Electronics Inc No. 581, Jui-Kuang Rd. Neihu, Taipei, 114, Taiwan, R.O.C. Prepared by COMPLIANCE CERTIFICATION SERVICES 561F MONTEREY ROAD, MORGAN HILL, CA 95037, USA TEL: (408) 463-0885 REPORT NO: 05I3576-3 DATE: August 23, 2005 FCC ID: GKRVT820 COMPLIANCE CERTIFICATION SERVICES Page: 2 of 41 This report shall not be reproduced except in full, without the written approval of CCS. Revision History Rev. Revisions Revised By A Initial issue HS REPORT NO: 05I3576-3 DATE: August 23, 2005 FCC ID: GKRVT820 COMPLIANCE CERTIFICATION SERVICES Page: 3 of 41 This report shall not be reproduced except in full, without the written approval of CCS. CERTIFICATE OF COMPLIANCE (SAR EVALUATION) DATES OF TEST: August 18, 19, 22 and 23, 2005 APPLICANT: ADDRESS: Compal Electronics Inc. No. 581, Jui-Kuang Rd Neihu, Taipei, 114, Taiwan R.O.C. FCC ID: MODEL: DEVICE CATEGORY: EXPOSURE CATEGORY: GKRVT820 VT820 Portable Device General Population/Uncontrolled Exposure Dual Band Tri-Mode AMPS/CDMA Cellular and PCS Phone Test Sample is a: Modulation type: Production unit AMPS, CDMA FCC Rule Parts Frequency Range [MHz] The Highest SAR Values 22 (AMPS) 824.04 ~ 848.97 head: 0.70 W/kg; body: 0.424 W/kg 22 (CDMA Cellular) 824.76 ~ 848.25 head: 0.46 W/kg; body: 0.251 W/kg 24 (CDMA PCS) 1851.25 ~ 1908.75 head: 1.53 W/kg; body: 0.180 W/kg Note: Body configuration: A separation distance of 1.5 cm between the back of the EUT and a flat phantom. This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC OET 65 Supplement C (Edition 01-01). And RSS-102 Issue 1 (Provisional) September 25, 1999. The maximum 1g SAR level measured for all the tests performed did not exceed the limits for General Population/Uncontrolled Exposure (W/kg) Partial Body of 1.6 W/kg. Level defined in Supplement C (Edition 01-01) to OET Bulletin 65 (97-01). Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by Compliance Certification Services and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Compliance Certification Services will constitute fraud and shall nullify the document. No part of this report may be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any government agency. Released For CCS By: Hsin Fu Shih Senior Engineer Compliance Certification Services REPORT NO: 05I3576-3 DATE: August 23, 2005 FCC ID: GKRVT820 COMPLIANCE CERTIFICATION SERVICES Page: 4 of 41 This report shall not be reproduced except in full, without the written approval of CCS. TABLE OF CONTENTS 1 Equipment Under Test (EUT) Description............................................................................................ 6 2 FACILITIES AND ACCREDITATION ................................................................................................... 6 3 System Description............................................................................................................................... 7 4 System Components ............................................................................................................................ 8 4.1 DASY4 Measurement Server........................................................................................................8 4.2 Data Acquisition Electronics (DAE)............................................................................................... 8 4.3 EX3DV3 Isotropic E-Field Probe for Dosimetric Measurements .................................................. 8 4.4 Light Beam Unit............................................................................................................................. 9 4.5 SAM Phantom (V4.0) .................................................................................................................... 9 4.6 Device Holder for SAM Twin Phantom ....................................................................................... 10 4.7 System Validation Kits ................................................................................................................ 10 4.8 Composition of Ingredients for tissue simulating liquid ............................................................... 10 5 Test positions for devices Operating Next To A Person’s Ear ........................................................... 11 5.1 Cheek/Touch Position ................................................................................................................. 12 5.2 Ear/Tilt Position ........................................................................................................................... 13 6 Test Positions For Body-worn And Other Similar Configurations ...................................................... 14 7 Simulating Liquid Parameters Check ................................................................................................. 15 7.1 Simulating Liquid Parameter Check Result ................................................................................ 16 8 System Performance Check............................................................................................................... 22 8.1 System Performance Check Result ............................................................................................ 23 9 SAR Measurement Procedure…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 8/18/2005 3:10:57 PMDate/Time: 8/18/2005 3:16:22 PM Test Laboratory: Compliance Certification Services 1_System Performance Check @ 835MHz DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; Οƒ = 0.911 mho/m; Ξ΅ r = 40.8; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 zSensor-Surface: 2.5mm (Mechanical Surface Detection) zElectronics: DAE3 Sn500; Calibrated: 2/7/2005 zPhantom: SAM 1; Type: SAM 1; zMeasurement SW: DASY4, V4.5 Build 19; d=15mm, Pin=250mW/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.98 mW/g d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 57.8 V/m; Power Drift = 0.016 dB Peak SAR (extrapolated) = 3.75 W/kg SAR(1 g) = 2.46 mW/g; SAR(10 g) = 1.6 mW/g Maximum value of SAR (measured) = 3.02 mW/g 0 dB = 3.02mW/g Date/Time: 8/18/2005 3:38:47 PM Test Laboratory: Compliance Certification Services 1_System Performance Check @ 835MHz DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 d=15mm, Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm Maximum value of SAR (measured) = 1.99 mW/g Date/Time: 8/19/2005 11:29:30 AMDate/Time: 8/19/2005 11:35:01 AM Test Laboratory: Compliance Certification Services 1_System Performance Check @ 835MHz DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; Οƒ = 0.906 mho/m; Ξ΅ r = 40.4; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 d=15mm, Pin=250mW/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.00 mW/g d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 58.1 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 3.77 W/kg SAR(1 g) = 2.48 mW/g; SAR(10 g) = 1.61 mW/g Maximum value of SAR (measured) = 3.04 mW/g 0 dB = 3.04mW/g Date/Time: 8/19/2005 11:41:03 AM Test Laboratory: Compliance Certification Services 1_System Performance Check @ 835MHz DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 d=15mm, Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm Maximum value of SAR (measured) = 2.00 mW/g Date/Time: 8/22/2005 1:53:28 PMDate/Time: 8/22/2005 1:58:47 PM Test Laboratory: Compliance Certification Services System Performance Check @ 1900MHz DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 - SN:5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; Οƒ = 1.43 mho/m; Ξ΅ r = 40.2; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(7.95, 7.95, 7.95); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 2; Type: SAM 2; Serial: 1050 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 d=10mm; Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 12.7 mW/g d=10mm; Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 96.0 V/m; Power Drift = 0.050 dB Peak SAR (extrapolated) = 17.2 W/kg SAR(1 g) = 9.56 mW/g; SAR(10 g) = 4.98 mW/g Maximum value of SAR (measured) = 12.8 mW/g 0 dB = 12.8mW/g Date/Time: 8/22/2005 2:04:54 PM Test Laboratory: Compliance Certification Services System Performance Check @ 1900MHz DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 - SN:5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 d=10mm; Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm Maximum value of SAR (measured) = 12.3 mW/g Date/Time: 8/23/2005 9:02:26 AMDate/Time: 8/23/2005 9:07:02 AM Test Laboratory: Compliance Certification Services System Performance Check @ 1900MHz DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 - SN:5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; Οƒ = 1.44 mho/m; Ξ΅ r = 39.8; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(7.95, 7.95, 7.95); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 2; Type: SAM 2; Serial: 1050 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 d=10mm; Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 13.3 mW/g d=10mm; Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 97.9 V/m; Power Drift = -0.024 dB Peak SAR (extrapolated) = 17.5 W/kg SAR(1 g) = 9.75 mW/g; SAR(10 g) = 5.08 mW/g Maximum val…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 8/19/2005 1:44:34 PMDate/Time: 8/19/2005 1:51:26 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: AMPS 835; Frequency: 836.49 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 836.49 MHz; Οƒ = 0.907 mho/m; Ξ΅ r = 40.4; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Touch - M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.701 mW/g Touch - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 5.64 V/m; Power Drift = -0.118 dB Peak SAR (extrapolated) = 0.859 W/kg SAR(1 g) = 0.590 mW/g; SAR(10 g) = 0.390 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.704 mW/g 0 dB = 0.704mW/g Date/Time: 8/19/2005 2:07:07 PMDate/Time: 8/19/2005 2:13:44 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: AMPS 835; Frequency: 836.49 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 836.49 MHz; Οƒ = 0.907 mho/m; Ξ΅ r = 40.4; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Tilt - M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.184 mW/g Tilt - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 7.38 V/m; Power Drift = -0.011 dB Peak SAR (extrapolated) = 0.217 W/kg SAR(1 g) = 0.163 mW/g; SAR(10 g) = 0.118 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.187 mW/g 0 dB = 0.187mW/g Date/Time: 8/19/2005 3:07:01 PMDate/Time: 8/19/2005 3:14:01 PM Test Laboratory: Compliance Certification Services 2_Right Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: AMPS 835; Frequency: 824.04 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 824.04 MHz; Οƒ = 0.897 mho/m; Ξ΅ r = 40.5; ρ = 1000 kg/m 3 Phantom section: Right Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Touch - L-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.526 mW/g Touch - L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 5.62 V/m; Power Drift = -0.104 dB Peak SAR (extrapolated) = 0.689 W/kg SAR(1 g) = 0.471 mW/g; SAR(10 g) = 0.308 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.569 mW/g 0 dB = 0.569mW/g Date/Time: 8/19/2005 2:29:20 PMDate/Time: 8/19/2005 2:36:16 PM Test Laboratory: Compliance Certification Services 2_Right Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: AMPS 835; Frequency: 836.49 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 836.49 MHz; Οƒ = 0.907 mho/m; Ξ΅ r = 40.4; ρ = 1000 kg/m 3 Phantom section: Right Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Touch - M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.681 mW/g Touch - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 6.38 V/m; Power Drift = -0.107 dB Peak SAR (extrapolated) = 0.885 W/kg SAR(1 g) = 0.607 mW/g; SAR(10 g) = 0.396 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.729 mW/g 0 dB = 0.729mW/g Date/Time: 8/19/2005 2:42:54 PM Test Laboratory: Compliance Certification Services 2_Right Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: AMPS 835; Frequency: 836.49 MHz;Duty Cycle: 1:1 Touch - M-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm Info: Interpolated medium parame…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 8/18/2005 6:08:20 PMDate/Time: 8/18/2005 6:15:01 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: CDMA; Frequency: 824.76 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 824.76 MHz; Οƒ = 0.904 mho/m; Ξ΅ r = 40.9; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Touch - L-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.354 mW/g Touch - L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 4.04 V/m; Power Drift = -0.030 dB Peak SAR (extrapolated) = 0.434 W/kg SAR(1 g) = 0.297 mW/g; SAR(10 g) = 0.198 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.356 mW/g 0 dB = 0.356mW/g Date/Time: 8/18/2005 4:39:42 PMDate/Time: 8/18/2005 4:46:26 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: CDMA; Frequency: 835.89 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 835.89 MHz; Οƒ = 0.912 mho/m; Ξ΅ r = 40.8; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE3 Sn500; Calibrated: 2/7/2005 - Phantom: SAM 1; Type: SAM 1; Serial: 1185 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146 Touch - M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.441 mW/g Touch - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm Reference Value = 4.90 V/m; Power Drift = -0.196 dB Peak SAR (extrapolated) = 0.545 W/kg SAR(1 g) = 0.378 mW/g; SAR(10 g) = 0.252 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.450 mW/g 0 dB = 0.450mW/g Date/Time: 8/18/2005 4:53:06 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: CDMA; Frequency: 835.89 MHz;Duty Cycle: 1:1 Touch - M-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.314 mW/g Date/Time: 8/18/2005 6:25:31 PMDate/Time: 8/18/2005 6:32:14 PM Test Laboratory: Compliance Certification Services 1_Left Hand Side DUT: Compal Electronics, Inc.; Type: VT820; Serial: B-Test1 145 Communication System: CDMA; Frequency: 848.25 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 848.25 MHz; Οƒ = 0.923 mho/m; Ξ΅ r = 40.7; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 23 deg. C; Liquid Temperature: 22 deg. C DASY4 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joyce Ting(Senior RF Regulatory Compliance Engineer)
[email protected]886-2-8797-8599Fax: 886-2-2658-6080

Test Firm

Compliance Certification Services IncSteve Cheng
[email protected]408-463-0885Fax: 408-463-0888

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
422H824.04 MHz - 848.97 MHz309.00 mW40K0F8W2.5 ppm
Confidentiality
Long Term
Grant Notes
Power output is ERP for Pt. 22 and EIRP for Pt. 24. SAR compliance for body-worn operating was tested with a 1.5 cm device-to-body spacing gap. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance Highest reported SAR values are AMPS Pt 22 head: 0.7 W/kg and body: 0.424 W/kg, CDMA Pt 22H head: 0.46 W/kg and body: 0.251 W/kg, and PCS Pt 24E head: 1.53 W/kg and body: 0.18 W/kg.

Other Applications from Compal Electronics Inc

GKRRXLN4N

LGA Module

May 26, 2026

Equipment Class

CBE - Citizens Band End User Devices
GKRCMMG3L

5G Module

May 08, 2026

Equipment Class

CBE - Citizens Band End User Devices
GKRRMMG4

5G Module

Jan 23, 2026

Equipment Class

CBE - Citizens Band End User Devices
GKRRXLN3

LGA Module

Dec 08, 2024

Equipment Class

CBE - Citizens Band End User Devices
GKRRMMT1

NTN miniPCIE module

Aug 14, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter