P370 / 470 RF Scanner Quick Reference Guide 2P370 / 470 RF Scanner © 1997 - 2006 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Warranty For the complete Symbol hardware product warranty statement, go to: http://www.symbol.com/warranty. Patents This product is covered by one or more patents. For patent information go to: http://www.symbol.com/patents. Quick Reference Guide3 Introduction The P470/370 cordless RF scanners bring new flexibility and economy to data capture and data management in both industrial and retail operations. The scanner communicates with your host computer through radio transmission instead of through a cable. With the RF scanner, you are free to scan and transmit without a physical cable, from as far away as 100 feet (30.5 meters) even without a direct line of sight. This lets you take the scanner to where the work is, whether on the loading dock, the plant floor, the warehouse, or the POS checkout area. There are several versions available: -P470: cordless retail scanner. -P370: cordless industrial scanner. -P370 ALR: cordless industrial ALR scanner. This Quick Reference Guide provides basic instruction on the set up and use of the Phaser P370/P470 RF scanners. Refer to PL 370/470 RF Cradle Quick Reference Guide (p/n 72-38494-xx) for information on setting up the PL 370/470 RF cradle. To quickly get you started with your new scanner: 1.Charge the scanner in the cradle. 2.Power up the scanner. 3.Follow the Quick Startup Instructions (see page 6). 4.Use the test bar codes to ensure the scanner is working properly (see page 7). Charging the Scanner in the Cradle Powering Up the Scanner To turn the scanner on, press the “Enter” key or pull the trigger. The scanner is brought out of sleep mode and into scanning mode. Charge Status Indicator Light To charge the scanner, insert the scanner into the cradle so the nose of the scanner and tip of the handle seat into the receptacles. The scanner displays “UNIT CRADLED” when properly inserted in the cradle. The battery charges automatically. A full charge of a depleted battery takes approximately 3-1/2 hours. The charge status indicator light on the back of the cradle blinks then becomes solid when the battery is fully charged. 4P370 / 470 RF Scanner Scanning Consult the P470/P370 RF Scanners Product Reference Guide (p/n 72-38495-xx) for programming instructions. If you need assistance, contact your local supplier or the Symbol Support Center. To scan: 1.Ensure the battery is charged. 2.Ensure the bar code is in the correct scanning range. 3.Aim and press the trigger. When the scanner has read the symbol: -a beep sounds. -the LED above the display turns green. -the red laser turns off. Aiming Hold at an Angle Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. Specular reflection can make decoding difficult. The scanner can tilt up to 65° forward or back and achieve a successful decode. Simple practice quickly shows what tolerances to work within. Scan Beam 1. Successful Scanning 2. Possible Specular Reflection 3.Successful Scanning 65° 65° Scan Beam Shaded area represents dead zone (+-2°) Bar Code Bar Code Bar Code Quick Reference Guide5 Scan the Entire Symbol -The scan beam must cross every bar and space on the symbol (as in the left bar code below). -Hold the scanner farther away for larger symbols. -Hold the scanner closer for symbols with bars that are close together. Changing the Battery When a battery is fully charged, it generally lasts up to 10 hours without being returned to the cradle. By returning it to the cradle during the day, this time is extended. If a significant decrease in battery life is noticed and does not correspond to increased usage, consider replacing the battery. Removing the Battery 1.Slide the battery release latch down using center indent and remove the battery compartment cover. 2.Slide the battery toward the bottom of the scanner and then pull the bottom of the battery back and out of the scanner. Replacing the Battery 1.Place the top portion of the battery (curved side up, contacts toward top) into the scanner and then slide it up the handle. 2.Replace the battery compartment cover. 3.Slide the release latch up to secure the cover in place. Battery Compartment Cover Battery Release Latch 6P370 / 470 RF Scanner Quick Startup Instructions The table that follows includes an index of startup instructions to help get you started quickly. The index is listed in a step-by-step order beginning with step 1, Setting up the System. This index references pages in the P470/P370 RF Scanners Product Reference Guide (p/n 72-38495-xx). The Product Reference Guide is included on the CD shipped with the scanner. It is also available on the Symbol Web site at: http://www.symbol.com/manuals. Mandatory steps are designated by an asterisk (*). If an item has multiple pages referenced, the most important reference is in bold. TopicPRG Page 1. Setting Up the System • Connecting the cradle…
Text truncated - open the document above for the full version.
Symbol Technologies, Inc. • One Symbol Plaza, Holtsville, NY 11742-1300 • 1.631.738.5134 • www.symbol.com Regulatory Engineering August 11, 2006 Federal Communications Commission Authorization and Evaluation Division Subject: Request for withholding from public disclosure for a limited time period sensitive business information submitted pursuant to and Application for Equipment Authorization with FCC ID: H9P470 To the Commission: Pursuant to Section 0.459 of the Commission’s Rules, and Section 552(b)(4) of the Freedom of Information Act, Symbol Technologies Hereby requests short term confidential treatment of information accompanying this Application for Equipment Authorization with FCC ID: H9PXXXXXXX for Exhibits as outlined below: 1. Internal Photographs 2. External Photographs 3. Test Setup Photographs 4. User’s Manual The above materials contain images, trade secrets, and proprietary information not customarily released to the public prior to offering for sale. The public disclosure of these matters might be harmful to Symbol Technologies and provide unjustified benefits to its competitors. Respectfully, Mark S. Luksich Director, Regulatory Engineering 631-738-5134 [email protected]
Symbol Technologies, Inc. • One Symbol Plaza, Holtsville, NY 11742-1300 • 1.631.738.5134 • www.symbol.com August 7, 2006 Regulatory Engineering Agent’s Authorization Letter I, Mark S. Luksich an officer of Symbol Technologies, Inc., do hereby authorize, until further notice, Curtis-Straus LLC, of 527 Great Road, Littleton, MA 01460, to act on our behalf in dealings before the Federal Communications Commission with respect to all matters relating to equipment authorizations under 47 CFR. This authorization includes, but is not limited to, the signing of Form 731. I certify that no party (as defined in 47 CFR 1.2002) to this application, including myself, is subject to a denial of federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C., 853A. Respectfully, Mark S. Luksich Director, Regulatory Engineering 631-738-5134 [email protected]
Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470 Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470 Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470 Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470
REVISIONS REV DESCRIPTION DATE APPROVED A Released per PD# 12156 07/21/94 DH B Changed per EDR# 13407, Revised Sections 6.3, 6.2.1, 6.2.8, 6.5, 6.6, Added Sections 4.4.3, 4.4.4, 6.3.3, 6.3.4, 6.7 Delete Appendix C and Change D to C 10/19/94 DH C Changed per PD# 15397, Modified Section 6.1, 6.2.9, 6.4.1, 6.4.7.1, 6.4.7.2, 6.4.8.1, 6.4.8.2 04/21/95 D Changed per DES# 31333, Remove Section 5 Modified all Sections to include Blaster printer, Modified Section 6.2.3, Deleted Section 6.4.8, Added Appendix E and Section 6.2.12 04/21/97 JL E Completely revised procedure to allow for common for all production printers. References to an OCR stripe on all label drawings are to be ignored. This procedure supercedes and replaces SP-11516-01 (obsolete) per PD# 55049 03/03/00 JL F Changed per PD# 59839, Added Section 4.6 Label to Label Definition, Modify Section 6.2.4 Core ID, Modify Section 6.2.5 Roll OD, Modify Section 6.2.12 Label to Label Spacing Deleted Section 6.3.3 08/07/00 JL G Changed title of spec, From: LABEL SPECIFICATION FOR SYMBOL PRODUCTION PRINTERS, To: LABEL DESIGN GUIDELINES AND SPECIFICATION FOR SYMBOL PRINTERS, Revised sect 6.3, Added sections showing minimum border and print sizes that the vendors can hold. PER PD #63828 7/24/03 M JONES/M SAVONA H Revised section 6.1 Field Titles, 6.2 MFG label material call used, 6.7.2 Note, Removed Appendix A and replaced it with Appendix B, Appendix B was Appendix C and was revised, Appendix C was Appendix D. RoHS compliance note has been added to MFG, Shipping & Laminate label material callouts. Per PD 64832 10/05/05 M JONES GUIDELINE: FOR SYMBOL LABELS AND SPECIFICATION FOR LABELS USED ON PRINTERS DOC. NO: SP-10083-01 SHEET 1 OF 11 REVISION: H LABEL SPECIFICATIONS FOR SYMBOL PRODUCTION PRINTERS SP-10083-01 Rev. H Table of Contents List of Effective Pages Page # 1.0 Purpose........................................................................................................................................................ 3 2.0 Scope ........................................................................................................................................................... 3 3.0 References ................................................................................................................................................... 3 4.0 Definitions ................................................................................................................................................... 3 5.0 Responsibilities ..........................................................................................................................................3 6.0 Process for labels being used in Symbol printers...................................................................................... 3 7.0 Records........................................................................................................................................................ 7 8.0 Attachments............................................................................................Appendix A Appendix B Appendix C Page 2 of 11 LABEL SPECIFICATIONS FOR SYMBOL PRODUCTION PRINTERS SP-10083-01 Rev. H 1.0 Purpose: To define the parameters required for all label stock used on Symbol Technologies production printers. 2.0 Scope: This procedure must be used whenever a label document/drawing is generated or labels are purchased to be used on a production Printer. 3.0 References: 3.1 EN-12421-01 Guidelines for documenting and releasing artwork. 3.2 EN-10845-01 Procedure: supplier artwork approval. 3.3 SP-12509-01 Specification for Environmental Compliance. 4.0 Definitions: 4.1 O.D. - Outside diameter 4.2 I.D. - Inside diameter 4.3 Critical Dimension - Dimensions that are critical to function. Used to designate those dimensions that affect the location of printing, placement of labels into printer, and placement of printed label onto unit. 4.4 Reference Dimension - Dimension not critical to function. Used to locate artwork or text. 4.5 Production Printer – All printers used to produce manufacturing or/and box labels in production. 4.6 Label to Label Spacing – The space between labels on a carrier. If the label is a single label, label to label spacing is measured from the bottom of each label to the top of the following label. If the label is part of a set of labels on the same carrier, label to label spacing is measured from the bottom of the last label in the set to the top of the first label in the new set. 5.0 Responsibility : 5.1 The Purchasing department is responsible for communicating these specifications to all production label suppliers. 5.2 The label Supplier is responsible for providing label/carrier material that conforms to these specifications. The Supplier is responsible for providing sample label/carrier material for Symbol Technologies, Inc. for approval and shall provide Symbol Technologies, Inc. with advance notice of material changes. 5.3 The Quality department is responsible for inspecting to these specifications. 5.4 The Technical Services Regulatory Engineering is responsible for designing labels that conform to these specifications. Page 3 of 11 LABEL SPECIFICATIONS FOR SYMBOL PRODUCTION PRINTERS SP-10083-01 Rev. H 6.0 Process : For Labels being used in Symbol printers 6.1 FIELD TITLES The following field titles are to be used as required: mod for model number (p/n for 1c products) s/n for serial number (only for the case that the human readable serial number does not appear right below the barcode of the serial number) (s)s/n for serial number barcode MFD: Represents manufacture day, month, year and revision of part number (ie: 12SEP03 X). Symbol Logo or Symbol Technologies, Inc. Holtsville, NY 11742 (Zip code is optional) Regulatory information and graphics as required (contact Regulatory Engineering for specific regulatory requirements) Minimum dimensions required for printable information on label is found in Appendix B. 6.2 NOTES T…
Text truncated - open the document above for the full version.
Symbol Technologies, Inc. • One Symbol Plaza, Holtsville, NY 11742-1300 • 1.631.738.5134 • www.symbol.com July 19, 2006 Regulatory Engineering Re: Exhibit 9 – Label & Label location FCC ID: H9P470 Respectfully, Mark S. Luksich Director, Regulatory Engineering 631-738-5134 [email protected]
Symbol Technologies Inc. FCC ID: H9P470 IC ID: 1549D-P470 Bottom Bottom (closer) Symbol Technologies Inc. FCC ID: H9P470 IC ID: 1549D-P470 Top Top (Closer) Symbol Technologies Inc. FCC ID: H9P470 IC ID: 1549D-P470 Top w/ RF Shield Removed Top w/ RF Shield Removed
Test Report Report No EG0843-1 Client Symbol Technologies Inc Mark Luksich Address One Symbol Plaza Holtsville, NY 11742 Phone 631-738-2400 Items tested P370/P470 FCC ID H9P470 FRN 0014741755 IC 1549D-P470 Emission Designator 325KF3D Standards CFR 47 FCC Part 15. Section 249(a); RSS 210 Issue 6 Equipment Code DXX Test Dates July 20 of 2006 Results As detailed within this report Prepared by Mairaj Hussain – Test Engineer Authorized by Michael Buchholz – EMC Manager Issue Date 8/9/06 Conditions of Issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 22 of this report. Curtis-Straus LLC is accredited to ISO/IEC 17025 by A2LA for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. See our scope of accreditation at the end of this test report. Any opinions or interpretations expressed in this report are outside the scope of our A2LA accreditation as A2LA only accredits testing. ____________________________________________________________ • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 1 of 26 Curtis-Straus Test Report for Symbol Technologies • Report No. EG0843-1 August 7, 2006 ______________________________________________________________________ Contents Contents....................................................................................................................................2 Summary...................................................................................................................................3 Product Tested - Configuration Documentation........................................................................4 Compliance Statement.............................................................................................................. 5 Statement of Conformity............................................................................................................5 Modifications Required for Compliance.....................................................................................5 Test Results..............................................................................................................................6 Duty Cycle Correction Factor (DCF)......................................................................................6 Section 15.249(a) Fundamental............................................................................................7 Section 15.205, 15.209 & 15.249(d)......................................................................................9 IC BW Plot...........................................................................................................................13 Test Equipment Used.............................................................................................................. 14 Jurisdictional Labeling and Required Instruction Manual Inserts............................................18 FCC Requirements..............................................................................................................18 Canadian Requirements......................................................................................................21 Conditions Of Testing..............................................................................................................22 A2LA Accreditation..................................................................................................................24 Form Final Report REV 6-16-06 (DW) ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 2 of 26 Test Report for Symbol Technologies • Report No. EG0843-1 August 7, 2006 ______________________________________________________________________ Summary This report is an application for certification of a transmitter operating under 47 CFR 15.section 249(a) of the FCC rules and RSS-210 Issue 6 operating in the frequency range 2404 – 2480MHz. The product covered by this test report is P370 and P470. P370 is similar to P470 except that P470 has a different plastic enclosure. All testing was performed according to the procedures specified in ANSI C63.4 (2003). The radio was tested with modulation on. All readings are peak unless otherwise noted. The product was tested with a fresh 3.6V battery. Peak and average readings were taken for fundamental. Worst case duty cycle correction factor was applied to the average readings at the fundamental (device is not pulse modulated). Furthermore, fundamental was measured at three channels, first, mid, and last. The EUT emissions were fully maximized, EUT’s antenna could to be maximized separately because it is integral part of the enclosure. Frequency range investigated: 30MHz – 25GHz Measurement Distance: Frequency (MHz) Distance (m) Comments Fundamental (Three channels) 2404, 2445, 2480MHz 3 m Radiated 30MHz – 18GHz 3m Radiated Spurious Measurements 18GHz – 25GHz 0.1m Radiated Spurious We found that the product met the requirements above without modification. Chris Klicpera from Symbol Technologies was present during the testing. The test sample was received in good condition. Release Control Record Issue No. Reason for change Date Issued 1 Ori ginal Release August 7, 2006 _____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 3 of 26 Test Report for Symbol Technologies • Report No. EG0843-1 August 7, 2006 ______________________________________________________________________ Product Tested - Configuration Documentation EUT: P370/P470 Sample number: 1 Cables: None Unpopulated ports: 1 RJ45 use for setup only EUT power: Symbol battery PN: 50-14000-145 Specification: 3.6V 1250 mAh Li-ion _____________________________________________________________ Curtis-Straus • 527 Gr…
Text truncated - open the document above for the full version.
Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470 Radiated Emissions Pictures Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470 Symbol Technologies Inc FCC ID: H9P470 IC ID: 1549D-P470
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Customer Concierge
Equipment Class
NII - Unlicensed National Information Infrastructure TX
802.11 abgn/ac Access Point
Equipment Class
DTS - Digital Transmission System
Touch Computer
Equipment Class
NII - Unlicensed National Information Infrastructure TX
UHF Narrowband Radio Module
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
802.15.4 Gateway
Equipment Class
DTS - Digital Transmission System