FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Symbol Technologies Inc/
  3. H9PP470

H9PP470P 370 / 470 Scanner

Symbol Technologies Inc
P 370 / 470 Scanner - FCC ID H9PP470 - Symbol Technologies Inc
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Sep 23, 1999
Application Purpose
Original Equipment
Date of Application
Jul 06, 1999
Equipment Note
P 370 / 470 Scanner
Frequency Range
2400.00000000 - 2483.50000000
Company
Symbol Technologies Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Preliminary P 370/470 Radio Scanner Preliminary P 370/470 Scanner  1997-1999 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/ 03938; Italy 1,138,713. rev. 4/99 Preliminary 1 Quick Reference Introduction The Phaser P 370/470 Radio Frequency (RF) scanner brings new flexibility and economy to data capture and data management in retail operations. The RF scanner has an integrated keypad and display, communicates with a base station and is battery-powered. This provides advanced point-of-sale scanning and also allows the scanner to be used for other in-store tasks such as delivery, inventory, pricing, and even gift registry. There are two versions available: • P 470: the RF retail version • P 370: the RF industrial version This Quick Reference Guide provides basic instruction on the set up and use of the scanner. Unless otherwise noted, the term Phaser refers to both versions of the scanner. Charge the Battery Before its first use, the battery must be charged. After the base/ charger has been connected, insert the scanner into the base/charger. To charge the scanner, place it front-side down into the base/charger. Make sure that the contacts in the bottom of the scanner match up with the metal contacts. Preliminary 2 P 370/470 Scanner A full charge takes up to 4 hours, you may need less time depending upon the remaining charge in the battery. The LED light on the bottom of the cradle becomes solid to alert you when the battery has been recharged. Scanning with the Phaser For POS operation, the scanner ships with a default application that is ready-to-use right out of the box. Otherwise, consult the Phaser Series Scanner Product Reference Guide (p/n 72-33495-xx) for programming instructions. If you need assistance, contact your local supplier or Symbol Support Center. 1. Ensure the battery is charged. 2. Make sure the bar code is in the correct scanning range. Aim and press the trigger. When the scanner has read the symbol: -You hear a beep. -The LED above the screen turns green. -The red laser turns off. Preliminary 3 Quick Reference Keyboard Entry Instead of scanning a bar code, you can enter the bar code’s data using the keypad on the top of the scanner. To enter numeric characters, press the number key on the keypad. To enter alpha characters, press the Mode key once to put the scanner in Alpha Mode. Press the numeric key with the letter you want above it - once for the first letter, quickly twice for the second letter, or quickly three times for the third letter. To return to numeric mode, press the Mode key again. The * key is a special key that can be programmed for custom specific operations. Ask your system administrator for more information. Host Communications With some terminal types, the Phaser is unable to answer host terminal polls until the appropriate host type is selected. This may result in an error message generated by the host computer. Contact your System Administrator for assistance. Preliminary 4 P 370/470 Scanner Aiming Hold at an angle Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone”. You can tilt the scanner up to 65 ° forw…

Text truncated - open the document above for the full version.

Attestation Statements

Edward Barnes Symbol Technologies, Inc. 1 Symbol Plaza Holtsville, N.Y. 11742 Voice : (516) 738-5358 Fax: (516) 738-3318 Letter of Confidentiality Request Dear Reviewer, Symbol Technologies (“Symbol”), requests that the Block Diagram, Schematics, and operational Description exhibits of the referenced application be withheld from routine availability for public inspection pursuant to Section 0.459 of the Commissions Rules an Freedom of Information Act (“FOIA) Exemption 4, 5 U.S.C. 552 (b) (4). These exhibits consist of “trade secrets (or) commercial or financial information obtained from a person and privileged or confidential” 5 U.S.C. 552 (b) (4), and is therefore entitled to protection from disclosure under FOIA. The documents in question contain trade secrets: detailed technical descriptions, specifications and schematics for a product to be offered for sale. These materials provide particulars on the product design. This information would give Symbol’s competitors an unearned and unwarranted competitive advantage. The documents contain “commercial information” within the scope of FOIA exemption 4. This information is the product of Symbol’s investment of money, personnel, and other resources. The result of the investment is a fairly earned position in the marketplace. Premature release of the information threatens substantial and unwarranted harm to Symbol’s competitive position. For these reasons, Symbol has taken pains to keep this technical information confidential, and intends to continue doing so. Symbol customarily witholds this information from persons outside the employ of Symbol and certain of its suppliers and contractors, and even within these groups routinely limits access to persons having a particular need for the information. If the Commission were to make these documents public, it would be giving away hard won fruits of Symbols labors without compensation. The filing fee that is required for this confidentiality request is included in the check that accompanies this application. If there are any questions about this request, please call me at the number above. Thank you for your attention. Respectfully submitted, Edward Barnes

ID Label/Location Info

Regulatory label content and location may be found on page 26 of the user's guide.

Test Report

Test Report Number R-8060 APPLICANT Symbol Technologies Inc One Symbol Plaza Holtsville, NY 11742 MANUFACTURER Same as Applicant TEST SPECIFICATION:FCC Rules and Regulations Part 15, Subpart C TEST PROCEDURE:ANSI C63.4:1992 TEST SAMPLE DESCRIPTION BRANDNAME:Symbol MODEL:P470 FCC ID:H9PP470 TYPE:2.4 GHz Pulsed Transmitter FREQUENCY RANGE:2480 to 2483.5 MHz POWER REQUIREMENTS: 4 VDC derived from rechargeable battery pack TESTS PERFORMED - 15.249(a)Radiated Emissions, Fundamental and Harmonics - 15.249(c)/15.209Out-of-Band Radiated Emissions - 15.249(c)Occupied Bandwidth Test Report Number R-8060 REPORT OF MEASUREMENTS Applicant:Symbol Technologies, Inc. Device:2.4 GHz Pulsed Transmitter FCC ID:H9PP470 Power Requirements:4 VDC derived from rechargeable battery pack Applicable Rule Section:Part 15, Subpart C, Section 15.249 TEST RESULTS 15.203:The intentional radiator is designed to ensure that no antenna other than that furnished by the applicant can be used with the device. 15.249(a):The unit operates in the 2400-2483.5MHz band. The field strength of the fundamental did not exceed 50mV/M AVERAGE. The field strength of the harmonics did not exceed 500μV/M AVERAGE. 15.249(b):Field strength readings were taken at three meters unless otherwise noted. 15.249(c):Emissions radiated outside the specified frequency band were attenuated in accordance with the general radiated emissions limits of 15.209. 15.249(d):The peak field strength of any emission did not exceed the maximum permitted average field strength by more than 20dB under any condition of modulation. GENERAL NOTES 1.All user accessible controls were adjusted to produce maximum emissions. 2. The device utilize a pulsed emission which has a worst case duty cycle of 30%. All readings above 1000 MHz were taken using a peak detector, were found to comply with the average limits. 3. The frequency range was scanned from 30MHz to 24.82 GHz. All emissions not reported were more than 20dB below the specified limit. Test Report Number R-8060 EXHIBIT 4 Radiated Emissions, Fundamental & Harmonics Para. 15.249(a) (Please see separate e-file attachments named FundHarmCh1.doc, FundHarmCh2.doc and FundHarmCh3.doc) Test Report Number R-8060 EXHIBIT 4 Out-of-Band Radiated Emissions Para. 15.249(c)/15.209 (Please see separate e-file attachments named REData1.doc, REData2.doc and REData3.doc) Test Report Number R-8060 EXHIBIT 4 Occupied Bandwidth Para. 15.249(c) (Please see separate e-file attachments named OccBw1.pdf, OccBw2.pdf and OccBw3.pdf) Test Report Number R-8060 EXHIBIT 4 Duty Cycle Determination (Please see separate e-file attachments named Dutycycle.pdf) Test Report Number R-8060 EQUIPMENT LIST FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 ENTypeManufacturerFrequency Range Model No.Cal Date Due Date 032GH.P. FilterMicrolab/FXR3 GHz - 6 GHzHA-30N4/29/984/29/99 032IH.P. FilterMicrolab/FXR5 GHz - 10 GHzHA-50N6/23/986/23/99 032JH.P. FilterMicrolab/FXR6 GHz - 12 GHzHD-60N6/23/986/23/99 065High Gain Horn AntennaMicrolab/FXR5.85 GHz - 8.2 GHzC638A1/25/991/25/00 066High Gain Horn AntennaMicrolab/FXR8.2 GHz - 12.4 GHzX638A1/25/991/25/00 067Open Area Test SiteRetlif3 MeterRNY8/30/978/30/99 129CHigh Gain Horn AntennaMicrolab/FXR12.4 GHz - 18 GHzY638A1/25/991/25/00 129FHigh Gain Horn AntennaMicrolab/FXR18 GHz - 26.5 GHzK638A10/14/9810/14/99 133Broadband Pre-AmplifierElectro-Metrics10 kHz - 1 GHz, 26dBBPA-10006/22/986/22/99 141Spectrum AnalyzerHewlett Packard100 Hz - 40 GHz8566B3/16/999/16/99 141AGraphics PlotterHewlett PackardN/A7470A3/5/993/5/00 141BQuasi-Peak AdaptorHewlett Packard100 Hz - 1 GHz85650A3/16/999/16/99 206B6.0 dB AttenuatorTexscan0 - 1.0 GHzFP-50 - 6 dB6/22/986/22/99 3116Pre-AmplifierMiteq0.1 GHz - 18 GHzAFS42-3512/3/9812/3/99 420AmplifierHewlett Packard2.0 GHz - 18 GHz11975A7/16/987/16/99 421Harmonic MixerHewlett Packard18 GHz - 26.5 GHz11970K7/2/977/2/99 523BiconilogElectro-Mechanics26 - 2000 MHz3142B10/22/984/22/00

Test Report

Retlif Testing Laboratories R Retlif Job Number R-8060 Data Sheet 1 of 3 Test Method: FCC Part 15 Radiated Emissions, 30 Mhz to 25 Ghz paragraph 15.209 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Bar Code Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: EUT continuously reading barcode, transmitting data to base station and receiving RF confirmation Technician: Dennis Cortes Date: May 28,1999 Notes: Test Distance: 3 Meters Temp:30C Humidity:35% Detector: Quasi-Peak Channel 1 (2402 Mhz) Test Freq. Antenna Position EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H)Degrees dBuv dB dBuv/m uv/m uV/m 30.0100 || VV 88.0100 88.0150 || || VV 216.0150 216.0200 || 223.1V-1.015832.1-7.224.917.6| 322.4V-1.415838.3-3.335.056.2| 390.8V-1.220338.4-2.136.365.3| 409.4V-1.015836.4-1.734.754.3| 422.0V-1.213537.5-1.536.063.1| || || VV 960.0200 960.0500 || V| 2412.7V-1.218045.3-0.145.2181.9| || || VV 25000.0500 The EUT was scanned from 30 Mhz to 25 Ghz The emissions observed from the EUT do not exceed the specified limits. Emissions not recorded were more than 10dB under the specified limit

Test Report

Retlif Testing Laboratories R Retlif Job Number R-8060 Data Sheet 2 of 3 Test Method: FCC Part 15 Radiated Emissions, 30 Mhz to 25 Ghz paragraph 15.209 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Bar Code Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: EUT continuously reading barcode, transmitting data to base station and receiving RF confirmation Technician: Dennis Cortes Date: May 28,1999 Notes: Test Distance: 3 Meters Temp:30C Humidity:35% Detector: Quasi-Peak Channel 2 (2445 Mhz) Test Freq. Antenna Position EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H)Degrees dBuv dB dBuv/m uv/m uV/m 30.0100 || VV 88.0100 88.0150 || || VV 216.0150 216.0200 || 223.1V-1.015832.1-7.224.917.6| 322.4V-1.415838.3-3.335.056.2| 390.8V-1.220338.4-2.136.365.3| 409.4V-1.015836.4-1.734.754.3| 422.0V-1.213537.5-1.536.063.1| || || VV 960.0200 960.0500 || V| 2455.7V-1.118044.7-0.144.6169.8| || || VV 25000.0500 The EUT was scanned from 30 Mhz to 25 Ghz The emissions observed from the EUT do not exceed the specified limits. Emissions not recorded were more than 10dB under the specified limit

Test Report

Retlif Testing Laboratories R Retlif Job Number R-8060 Data Sheet 3 of 3 Test Method: FCC Part 15 Radiated Emissions, 30 Mhz to 25 Ghz paragraph 15.209 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Bar Code Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: EUT continuously reading barcode, transmitting data to base station and receiving RF confirmation Technician: Dennis Cortes Date: May 28,1999 Notes: Test Distance: 3 Meters Temp:30C Humidity:35% Detector: Quasi-Peak Channel 3 (2480 Mhz) Test Freq. Antenna Position EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H)Degrees dBuv dB dBuv/m uv/m uV/m 30.0100 || VV 88.0100 88.0150 || || VV 216.0150 216.0200 || 223.1V-1.015832.1-7.224.917.6| 322.4V-1.415838.3-3.335.056.2| 390.8V-1.220338.4-2.136.365.3| 409.4V-1.015836.4-1.734.754.3| 422.0V-1.213537.5-1.536.063.1| || || VV 960.0200 960.0500 || V| 2490.7V-1.118045.1-0.145.0177.8| || || VV 25000.0500 The EUT was scanned from 30 Mhz to 25 Ghz The emissions observed from the EUT do not exceed the specified limits. Emissions not recorded were more than 10dB under the specified limit

Test Report

Data Sheet 1 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.445 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Temp: 30C Humidity:35% Detector: Peak Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m uV/m uV/m 2445H / 1.1X61.033.994.955590.4500000 2445H / 1.4Y67.333.9101.2114815.4500000 2445H / 1.1Z63.433.997.373282.5500000 2445V / 1.3X67.233.9101.1113501.1500000 2445V / 1.4Y60.933.994.854954.1500000 2445V / 1.0Z61.233.995.156885.3500000 4890H / 1.1X44.2-0.643.6151.45000 4890H / 1.1Y45.6-0.645.0177.85000 4890H / 1.2Z46.0-0.645.4186.25000 4890V / 1.3X44.3-0.643.7153.15000 4890V / 1.4Y42.4-0.641.8123.05000 4890V / 1.2Z41.8-0.641.2114.85000 7335H / 1.0X43.1-6.636.566.85000 7335H / 1.0Y48.0-6.641.4117.55000 7335H / 1.1Z43.4-6.636.869.25000 7335V / 1.2X46.0-6.639.493.35000 7335V / 1.0Y40.8-6.634.251.35000 7335V / 1.0Z42.2-6.635.660.35000 9780H / 1.0X43.4-2.840.6*107.25000 9780H / 1.0Y43.4-2.840.6*107.25000 9780H / 1.0Z43.4-2.840.6*107.25000 9780V / 1.0X43.4-2.840.6*107.25000 9780V / 1.0Y43.4-2.840.6*107.25000 9780V / 1.0Z43.4-2.840.6*107.25000 12225H / 1.0X43.70.444.1*160.35000 12225H / 1.0Y43.70.444.1*160.35000 12225H / 1.0Z43.70.444.1*160.35000 12225V / 1.0X43.70.444.1*160.35000 12225V / 1.0Y43.70.444.1*160.35000 12225V / 1.0Z43.70.444.1*160.35000 The frequency range was scanned from 30 Mhz to 25 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 2 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.445 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Temp: 30C Humidity:35% Detector: Quasi-Peak Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m UV/m uV/m 14670H / 1.0X37.83.741.5*118.95000 14670H / 1.0Y37.83.741.5*118.95000 14670H / 1.0Z37.83.741.5*118.95000 14670V / 1.0X37.83.741.5*118.95000 14670V / 1.0Y37.83.741.5*118.95000 14670V / 1.0Z37.83.741.5*118.95000 17115H / 1.0X37.19.446.5*211.35000 17115H / 1.0Y37.19.446.5*211.35000 17115H / 1.0Z37.19.446.5*211.35000 17115V / 1.0X37.19.446.5*211.35000 17115V / 1.0Y37.19.446.5*211.35000 17115V / 1.0Z37.19.446.5*211.35000 19560H / 1.0X32.222.754.9*555.95000 19560H / 1.0Y32.222.754.9*555.95000 19560H / 1.0Z32.222.754.9*555.95000 19560V / 1.0X32.222.754.9*555.95000 19560V / 1.0Y32.222.754.9*555.95000 19560V / 1.0Z32.222.754.9*555.95000 22005H / 1.0X32.523.055.5*595.75000 22005H / 1.0Y32.523.055.5*595.75000 22005H / 1.0Z32.523.055.5*595.75000 22005V / 1.0X32.523.055.5*595.75000 22005V / 1.0Y32.523.055.5*595.75000 22005V / 1.0Z32.523.055.5*595.75000 24450H / 1.0X32.923.456.3*653.15000 24450H / 1.0Y32.923.456.3*653.15000 24450H / 1.0Z32.923.456.3*653.15000 24450V / 1.0X32.923.456.3*653.15000 24450V / 1.0Y32.923.456.3*653.15000 24450V / 1.0Z32.923.456.3*653.15000 The frequency range was scanned from 30 Mhz to 25.0 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 3 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.445 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Duty Cycle: 30% Detector: Peak Duty Cycle Correction: -10.5 dB Test Freq. Antenna Pol./Height EUT Orientation Peak Reading Correction Factor Corrected Reading Converted Reading Average Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m uV/m uV/m 2445H / 1.1X94.9-10.584.416595.950000 2445H / 1.4Y101.2-10.590.734276.850000 2445H / 1.1Z97.3-10.586.821877.650000 2445V / 1.3X101.1-10.590.633884.450000 2445V / 1.4Y94.8-10.584.316405.950000 2445V / 1.0Z95.1-10.584.616982.450000 4890H / 1.1X43.6-10.533.145.2500 4890H / 1.1Y45.0-10.534.553.1500 4890H / 1.2Z45.4-10.534.955.6500 4890V / 1.3X43.7-10.533.245.7500 4890V / 1.4Y41.8-10.531.336.7500 4890V / 1.2Z41.2-10.530.734.3500 7335H / 1.0X36.5-10.526.020.0500 7335H / 1.0Y41.4-10.530.935.1500 7335H / 1.1Z36.8-10.526.320.7500 7335V / 1.2X39.4-10.528.927.9500 7335V / 1.0Y34.2-10.523.715.3500 7335V / 1.0Z35.6-10.525.118.0500 9780H / 1.0X40.6-10.530.1*32.0500 9780H / 1.0Y40.6-10.530.1*32.0500 9780H / 1.0Z40.6-10.530.1*32.0500 9780V / 1.0X40.6-10.530.1*32.0500 9780V / 1.0Y40.6-10.530.1*32.0500 9780V / 1.0Z40.6-10.530.1*32.0500 12225H / 1.0X44.1-10.533.6*47.9500 12225H / 1.0Y44.1-10.533.6*47.9500 12225H / 1.0Z44.1-10.533.6*47.9500 12225V / 1.0X44.1-10.533.6*47.9500 12225V / 1.0Y44.1-10.533.6*47.9500 12225V / 1.0Z44.1-10.533.6*47.9500 The frequency range was scanned from 30 Mhz to 25 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 4 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.445 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Dist…

Text truncated - open the document above for the full version.

Test Report

Data Sheet 1 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.480 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Temp: 30C Humidity:35% Detector: Peak Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m uV/m uV/m 2480H / 1.5X61.833.995.760953.7500000 2480H / 1.3Y67.633.9101.5118850.2500000 2480H / 1.3Z64.233.998.180352.6500000 2480V / 1.2X65.633.999.594406.1500000 2480V / 1.2Y61.233.995.156885.3500000 2480V / 1.2Z60.033.993.949545.0500000 4960H / 1.0X45.1-0.644.5167.95000 4960H / 1.2Y46.5-0.645.9197.25000 4960H / 1.4Z47.3-0.646.7216.35000 4960V / 1.2X45.6-0.645.0177.85000 4960V / 1.3Y43.9-0.643.3146.25000 4960V / 1.4Z41.7-0.641.1113.55000 7440H / 1.0X42.3-6.635.761.05000 7440H / 1.0Y48.0-6.641.4117.55000 7440H / 1.0Z43.2-6.636.667.65000 7440V / 1.2X49.8-6.643.2144.55000 7440V / 1.1Y43.0-6.636.466.15000 7440V / 1.0Z43.1-6.636.566.85000 9920H / 1.0X43.4-2.840.6*107.25000 9920H / 1.0Y43.4-2.840.6*107.25000 9920H / 1.0Z43.4-2.840.6*107.25000 9920V / 1.0X43.4-2.840.6*107.25000 9920V / 1.0Y43.4-2.840.6*107.25000 9920V / 1.0Z43.4-2.840.6*107.25000 12400H / 1.0X43.70.444.1*160.35000 12400H / 1.0Y43.70.444.1*160.35000 12400H / 1.0Z43.70.444.1*160.35000 12400V / 1.0X43.70.444.1*160.35000 12400V / 1.0Y43.70.444.1*160.35000 12400V / 1.0Z43.70.444.1*160.35000 The frequency range was scanned from 30 Mhz to 25 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 2 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.480 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Temp: 30C Humidity:35% Detector: Quasi-Peak Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m UV/m uV/m 14880H / 1.0X37.83.741.5*118.95000 14880H / 1.0Y37.83.741.5*118.95000 14880H / 1.0Z37.83.741.5*118.95000 14880V / 1.0X37.83.741.5*118.95000 14880V / 1.0Y37.83.741.5*118.95000 14880V / 1.0Z37.83.741.5*118.95000 17360H / 1.0X37.19.446.5*211.35000 17360H / 1.0Y37.19.446.5*211.35000 17360H / 1.0Z37.19.446.5*211.35000 17360V / 1.0X37.19.446.5*211.35000 17360V / 1.0Y37.19.446.5*211.35000 17360V / 1.0Z37.19.446.5*211.35000 19840H / 1.0X32.222.754.9*555.95000 19840H / 1.0Y32.222.754.9*555.95000 19840H / 1.0Z32.222.754.9*555.95000 19840V / 1.0X32.222.754.9*555.95000 19840V / 1.0Y32.222.754.9*555.95000 19840V / 1.0Z32.222.754.9*555.95000 22320H / 1.0X32.523.055.5*595.75000 22320H / 1.0Y32.523.055.5*595.75000 22320H / 1.0Z32.523.055.5*595.75000 22320V / 1.0X32.523.055.5*595.75000 22320V / 1.0Y32.523.055.5*595.75000 22320V / 1.0Z32.523.055.5*595.75000 24800H / 1.0X32.923.456.3*653.15000 24800H / 1.0Y32.923.456.3*653.15000 24800H / 1.0Z32.923.456.3*653.15000 24800V / 1.0X32.923.456.3*653.15000 24800V / 1.0Y32.923.456.3*653.15000 24800V / 1.0Z32.923.456.3*653.15000 The frequency range was scanned from 30 Mhz to 25.0 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 3 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.480 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distance: 3 Meters Duty Cycle: 30% Detector: Peak Duty Cycle Correction: -10.5 dB Test Freq. Antenna Pol./Height EUT Orientation Peak Reading Correction Factor Corrected Reading Converted Reading Average Limit Mhz(V/H) / DegreesX / Y / Z dBuv dB dBuV/m uV/m uV/m 2480H / 1.2X95.7-10.585.218197.050000 2480H / 1.2Y101.5-10.591.035481.350000 2480H / 1.4Z98.1-10.587.623988.350000 2480V / 1.4X99.5-10.589.028183.850000 2480V / 1.0Y95.1-10.584.616982.450000 2480V / 1.0Z93.9-10.583.414791.150000 4960H / 1.0X44.5-10.534.050.1500 4960H / 1.4Y45.9-10.535.458.9500 4960H / 1.3Z46.7-10.536.264.6500 4960V / 1.3X45.0-10.534.553.1500 4960V / 1.2Y43.3-10.532.843.7500 4960V / 1.3Z41.1-10.530.633.9500 7440H / 1.2X35.7-10.525.218.2500 7440H / 1.0Y41.4-10.530.935.1500 7440H / 1.2Z36.6-10.526.120.2500 7440V / 1.3X43.2-10.532.743.2500 7440V / 1.0Y36.4-10.525.919.7500 7440V / 1.0Z36.5-10.526.020.0500 9920H / 1.0X40.6-10.530.1*32.0500 9920H / 1.0Y40.6-10.530.1*32.0500 9920H / 1.0Z40.6-10.530.1*32.0500 9920V / 1.0X40.6-10.530.1*32.0500 9920V / 1.0Y40.6-10.530.1*32.0500 9920V / 1.0Z40.6-10.530.1*32.0500 12400H / 1.0X44.1-10.533.6*47.9500 12400H / 1.0Y44.1-10.533.6*47.9500 12400H / 1.0Z44.1-10.533.6*47.9500 12400V / 1.0X44.1-10.533.6*47.9500 12400V / 1.0Y44.1-10.533.6*47.9500 12400V / 1.0Z44.1-10.533.6*47.9500 The frequency range was scanned from 30 Mhz to 25 Ghz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements ( Minimum system sensitivity) Data Sheet 4 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions Paragraph 15.249 Customer: Symbol Technologies, Inc Job No. R-8060 Test Sample: Wireless Barcode Scanner FCC ID: H9PP470 Model No.: P470 Serial No. N/A Operating Mode: Continuously Transmitter 2.480 Ghz Signal Technician: Dennis Cortes Date: June 3,1999 Notes: Test Distan…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Qianlin Zhou(Regulatory Specialist)
[email protected]346-260-3543Fax: 631-627-7178

Technical Contact

Retlif Testing LaboratoriesThomas J Schneider
[email protected]516-737-1500

795 Marconi Avenue · Ronkonkoma, New York · United States

Non-Technical Contact

Retlif Testing LaboratoriesMichelle Tirado
[email protected]516-737-1500

Test Firm

Retlif Testing LaboratoriesMichael Bozza
[email protected]631-737-1500Fax: 631-737-1497

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Symbol Technologies Inc

Customer Concierge - FCC ID H9PCCHUB1 - Symbol Technologies Inc
H9PCCHUB1

Customer Concierge

Jun 30, 2015

Equipment Class

NII - Unlicensed National Information Infrastructure TX
802.11 abgn/ac Access Point - FCC ID H9PAP7562 - Symbol Technologies Inc
H9PAP7562

802.11 abgn/ac Access Point

May 10, 2015

Equipment Class

DTS - Digital Transmission System
Touch Computer - FCC ID H9PTC75AH - Symbol Technologies Inc
H9PTC75AH

Touch Computer

Mar 26, 2015

Equipment Class

NII - Unlicensed National Information Infrastructure TX
UHF Narrowband Radio Module - FCC ID H9PRA1202 - Symbol Technologies Inc
H9PRA1202

UHF Narrowband Radio Module

Sep 24, 2014

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
802.15.4 Gateway - FCC ID H9PEMG101 - Symbol Technologies Inc
H9PEMG101

802.15.4 Gateway

Aug 26, 2014

Equipment Class

DTS - Digital Transmission System