Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TT03 User Guide V0.4 Sysgration Confidential 1 TPMS Trigger Tool TT03 User Guide V0.4 Prepared by: Sysgration Inc. Cooperation TT03 User Guide V0.4 Sysgration Confidential 2 Outline Introduction ................................................................................................................................. 3 Button UI: .................................................................................................................................... 4 User Guide: ................................................................................................................................. 7 TT03 User Guide V0.4 Sysgration Confidential 3 Introduction ⚫ Purpose TT03 is a Bluetooth TPMS trigger tool. Sending the low frequency trigger signal wakeup TPMS, then displays tire Pressure /Temperature/TPMS serial number on screen. ⚫ Operation scenario User press button, trigger TPMS and get Pressure /Temperature/TPMS serial number on screen. ⚫ TT03 2.4G antenna position: TT03 User Guide V0.4 Sysgration Confidential 4 Button UI: Screen state Action Power Off Power On (display 2s) Main Menu SCAN / TRIGGER (no sensor) SCAN / TRIGGER (searching) SCAN / TRIGGER (found sensor) HISTORY screen Long press Power key (USB plug out) Power on Power off Power off Power off Power off Power off Short press UP key Cursor up Cursor up Short press Down key Cursor down Cursor down Short press OK key No response for TPMS INFO item Short press Cancel key Back to BLE TPMS CHECK menu Cancel trigger Back to BLE TPMS CHECK menu Back to main menu Short press Trigger key Start trigger Start trigger Screen state Action INSPECT (no sensor) INSPECT (searching) INSPECT (found sensor) Long press Power key (USB plug out) Power off Power off Power off Short press UP key Short press Down key Short press OK key Short press Cancel key Back to BLE TPMS CHECK menu Cancel trigger Back to BLE TPMS CHECK menu Short press Trigger key Start trigger Start trigger then connect TT03 User Guide V0.4 Sysgration Confidential 5 Screen state Action BLE CONN TEST (no sensor) BLE CONN TEST (searching) BLE CONN TEST (found sensor) Long press Power key (USB plug out) Power off Power off Power off Short press UP key Short press Down key Short press OK key Short press Cancel key Back to main menu Cancel trigger Back to main menu Short press Trigger key Start trigger Start trigger then connect Screen state Action MMY RF TPMS CHECK (no sensor) MMY RF TPMS CHECK (searching) MMY RF TPMS CHECK (found sensor) Long press Power key (USB plug out) Power off Power off Power off Short press UP key Short press Down key Short press OK key Short press Cancel key Back to MMY menu Cancel trigger Back to MMY menu Short press Trigger key Start trigger Start trigger then connect TT03 User Guide V0.4 Sysgration Confidential 6 Screen state Action Settings menu Enter combo box field FW Upgrade screen BT upgrade screen USB upgrade screen (without USB plug in) RESTORE screen ABOUT screen Long press Power key(USB plug out) Power off Power off Power off Power off Power off Power off Power off Short press UP key Cursor up Switch field data item Cursor up Short press Down key Cursor down Switch field data item Cursor down Short press OK key Respond item: FW UPGRADE、 RESTORE、 ABOUT Other items no response Respond item: USB、 BLUETOOTH Reset to default settings then back to settings menu Short press Cancel key Back to main menu Back to settings menu Back to FW upgrade menu Back to FW upgrade menu Back to settings menu Back to settings menu Short press Trigger key Short press Left key Exit combo box field Short press Right key Jump to combo box field item pointed by cursor. Plug-in USB Enter USB DFU TT03 User Guide V0.4 Sysgration Confidential 7 User Guide: ⚫ Power on: TT03 Screen Display TT03 Home Page for 2 seconds when powering on. Enter MAIN screen Display TT03 information for 2 seconds when powering on. TT03 User Guide V0.4 Sysgration Confidential 8 ⚫ Power off: TT03 Screen Note:TT03 Will keep power on if under TYPE-C connection. TT03 User Guide V0.4 Sysgration Confidential 9 ⚫ Trigger Sensor : 1. BLE TPMS CHECK: SCAN/TRIGGER TT03 Screen Press or to make the cursor move to “BLE TPMS CHECK” , then press to enter the “BLE TPMS CHECK” screen. Press to trigger sensor Start searching the sensor as below, or you can stop the trigger progress by pressing. Found the sensor Fail to find the sensor Press or to make the cursor move to “SCAN/TRIGGER” , then press to enter the “SCAN/TRIGGER” screen. TT03 User Guide V0.4 Sysgration Confidential 10 2. BLE TPMS CHECK: INSPECT TT03 Screen Press or to make the cursor move to “BLE TPMS CHECK” , then press to enter the “BLE TPMS CHECK” screen. Press to trigger sensor Start searching the sensor as below, or you can stop the trigger progress by pressing. Found the sensor Fail to find the sensor If result is OEM senor will display “PASS” Press or to make the cursor move to “INSPECT” , then press to enter the “INSPECT” screen. Connect fail If result is none OEM sensor will display “non-OEM” None OEM sensor If inspect process not success will display “FAIL” TT03 User Guide V0.4 Sysgration Confidential 11 3. BLE TPMS CHECK: OOK TT03 Screen Press or to make the cursor move to “BLE TPMS CHECK” , then press to enter the “BLE TPMS CHECK” screen. Press to trigger sensor Start searching the sensor as below, or you can stop the trigger progress by pressing. Found the sensor Fail to find the sensor Press or to make the cursor move to “OOK” , then press to enter the “OOK” screen. TT03 User Guide V0.4 Sysgration Confidential 12 4. RF TPMS CHECK: Select the R sensor to be triggered from the MMY menu. (Example: Model 3, 2017-2020) TT03 Screen Press or to make the cursor move to “RF TPMS CHECK” , then press to enter the “RF TPMS CHECK” screen. Select “2017-2020” year menu item, then press to enter the “2017-2020”screen. Press to trigger sensor Found the sensor Fail to find the sensor Press or to make the cursor move to “MODEL 3” , then press to enter t…
Text truncated - open the document above for the full version.
Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Sysgration Ltd. 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. Taipei City Taiwan 114 Certification Application Attestation Statements <Company name> Sysgration Ltd. 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. Taipei City Taiwan 114 Subject: FCC ID: < HQXTT03> To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) [Sysgration Ltd.] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Sysgration Ltd.] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2024/05/15 City: Taipei City 114 Name : Poll Chang Function: Manager Telephone number: 886-2-2790-0088 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” 2024/05/15
Agent letter FCC attestation statement Kiwa Page 1 of 2 RF_753, Issue 2 15-02-2023 Sysgration Ltd. 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. Taipei City Taiwan 114 U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: Sysgration USA Inc. FRN: Contact person name: Serina Lee Street address: 37 Mountain View Ave ZIP/City/State San Jose, CA 95127 Telephone number: 408-250-9270 Email address: [email protected] Signature: Date: Serina Lee 2024/05/15 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Sysgration Ltd. Grantee Code: HQX Contact person name: Poll Chang Street address: 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. ZIP/City/State Taipei City 114 Telephone number: 886-2-2790-0088 Email address: [email protected] Signature: Date: 2024/05/15 0020668364(for grantee's FRN)
RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 (On manufacturer’s company letter heading) Declaration of Authorization We Name: Sysgration Ltd. Address: 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. City: Taipei City 114 . Country: Taiwan. Declare that: Name Representative of agent: Chieh Tseng Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd Address: 6F., No. 58, Lane 188, Ruey Kuang Road, Neihu district, City: Taipei 114, Country Taiwan is authorized to apply for Certification of the following product(s): Product description: TPMS Trigger Type designation: TT03 Trademark: SYSGRATION Validity/ expiry date on our behalf. Date: City: Name: Function: 2024/05/15 Taipei City Poll Chang Manager Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. 2024/5/15
FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Sysgration Ltd. Address: 6F, No.1, Sec.1,Tiding Blvd., Neihu Dist. City: Taipei City 114 Country: Taiwan To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: HQXTT03 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 2024/05/15 Name and signature of applicant: Poll Chang Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period 2024/5/15
Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 46 External Photos Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 46
Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 46
Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 46 Internal Photos Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 46
SPORTON INTERNATIONAL INC. Page Number : 1 of 14 TEL : 886-3-327-3456 Report Issued Date : Jun. 24, 2024 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA440911 RF Exposure Report FCC ID : HQXTT03 Equipment : TPMS Trigger Brand Name : SYSGRATION Model Name : TT03 Applicant : Sysgration Ltd. 6F.,No.1,Sec.1,Tiding Blvd.,Neihu Dist. Taipei City 114, Taiwan Standard : FCC 47 CFR Part 2.1093 The product was received on May 14, 2024 and testing was started from Jun. 12, 2024 and completed on Jun. 12, 2024. We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample provide by manufacturer and the test data has been evaluated in accordance with the test procedures given in 47 CFR Part 2.1093 and has been pass the FCC requirement. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full. Sporton International Inc. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan Approved by: Cona Huang / Deputy Manager SPORTON INTERNATIONAL INC. Page Number : 2 of 14 TEL : 886-3-327-3456 Report Issued Date : Jun. 24, 2024 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA440911 Table of Contents 1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. RF EXPOSURE LIMIT ................................................................................................................................. 5 3. SYSTEM DESCRIPTION AND SETUP ....................................................................................................... 6 4. EQUIPMENT LIST ....................................................................................................................................... 9 5. SYSTEM VALIDIATION .............................................................................................................................. 9 6. RF EXPOSURE RESULTS ........................................................................................................................ 10 6.1. Maximum Permissible Exposure Evaluation ................................................................................... 10 6.2. Peak Spatial-Average SAR Evaluation ............................................................................................ 10 7. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................... 11 8. UNCERTAINTY .......................................................................................................................................... 12 9. REFERENCE ............................................................................................................................................. 14 Appendix A. Plots of System Performance Check Appendix B. Plots of Highest Measurement Result Appendix C. DASY Calibration Certificate Appendix D. Test Setup Photo SPORTON INTERNATIONAL INC. Page Number : 3 of 14 TEL : 886-3-327-3456 Report Issued Date : Jun. 24, 2024 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA440911 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA440911 Rev. 01 Initial issue of report Jun. 24, 2024 SPORTON INTERNATIONAL INC. Page Number : 4 of 14 TEL : 886-3-327-3456 Report Issued Date : Jun. 24, 2024 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA440911 1. Description of Equipment Under Test (EUT) Product Feature & Specification FCC ID HQXTT03 Equipment TPMS Trigger Brand Name SYSGRATION Model Name TT03 Frequency Range RFID: 125 kHz Tx 2440MHz Bluetooth: 2402 MHz ~ 2480 MHz Mode RFID: ASK Tx 2440MHz: GFSK Bluetooth: BLE HW Version V4R2 SW Version V007 SPORTON INTERNATIONAL INC. Page Number : 5 of 14 TEL : 886-3-327-3456 Report Issued Date : Jun. 24, 2024 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA440911 2. RF Exposure Limit <Limits for Maximum Permissible Exposure> § 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of § 2.1093 of this chapter. (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception of transient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over the…
Text truncated - open the document above for the full version.
PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 18 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 19 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 20 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 21 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 22 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 125 kHz PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 23 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 315 MHz & 434 MHz PHOTOGRAPHS OF EUT Report No.: EP440911 TEL : 886-3-327-3456 Page Number : 24 of 24 FAX : 886-3-328-4978 Issue Date : Jun. 28, 2024 Report Version : 01 ─────THE END──── Bluetooth & 2440 MHz
of Applicant: Sysgration Ltd. Address: 6F.,No.1,Sec.1,Tiding Blvd.,Neihu Dist. Taipei City 114 Taiwan Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1141, TW1146, TW1477, TW0200, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 5107A, 31634 Report No.: W6M22404-23411-C-3 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for TPMS Trigger Model No.: TT03 FCC ID: HQXTT03 Registration number: W6M22404-23411-C-3 FCC ID: HQXTT03 Worldwide Testing Services (Taiwan) Co., Ltd. Page 1 of 23 TABLE OF CONTENTS 1 General Information ............................................................................................................................ 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ................................................................................................... 3 1.4 APPLICATION DETAILS ................................................................................................................. 3 1.5 GENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.6 TEST STANDARDS ......................................................................................................................... 4 2 Technical test ...................................................................................................................................... 5 2.1 SUMMARY OF TEST RESULTS ........................................................................................................ 5 2.2 T EST ENVIRONMENT .................................................................................................................... 5 2.3 TEST EQUIPMENT LIST ................................................................................................................. 6 2.4 GENERAL TEST PROCEDURE ........................................................................................................ 7 3 Test results (enclosure) ....................................................................................................................... 8 3.1 PEAK OUTPUT POWER ................................................................................................................. 8 3.2 SPURIOUS EMISSIONS RADIATED – TRANSMITTER OPERATING ................................................... 11 3.3 O CCUPIED BANDWIDTH ............................................................................................................. 13 3.4 ANTENNA REQUIREMENT ........................................................................................................... 14 3.5 RADIATED EMISSIONS FROM RECEIVER SECTION OF RECEIVER PART ....................................... 15 3.6 POWER LINE CONDUCTED EMISSION ......................................................................................... 17 Appendix: Diagrams R egistration number: W6M22404-23411-C-3 FCC ID: HQXTT03 Worldwide Testing Services (Taiwan) Co., Ltd. Page 2 of 23 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. Tester: May 24, 2024 Rick Chen Date WTS-Lab. Name Signature T echnical responsibility for area of testing: M ay 24, 2024 Kevin Wang Date WTS Name Signature R egistration number: W6M22404-23411-C-3 FCC ID: HQXTT03 Worldwide Testing Services (Taiwan) Co., Ltd. Page 3 of 23 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) X izhi Lab No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1141, TW1146, TW1477, TW0200, TW0037 I ndustry Canada filed test laboratory Reg. No.: 20037, 5107A, 31634 T est location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited number: ./. Street: ./. Town: ./. Country: ./. 1. 3 Details of approval holder N ame:Sysgration Ltd. Street: 6F.,No.1,Sec.1,Tiding Blvd.,Neihu Dist. City: Taipei City 114 Country: Taiwan 1. 4 Application details D ate of receipt of test item: May 02, 2024 Date of test: from May 03, 2024 to May 24, 2024 Registration number: W6M22404-23411-C-3 FCC ID: HQXTT03 Worl…
Text truncated - open the document above for the full version.
LinkCom Manufacturing Co.,Ltd LRC0027-50X 1 Rev.A R Choke RoHS Compliant Operating Temperature -40°C to +85°C Electrical Specifications @25°C Inductance: S-F:155uH ±5%. @ 125KHz/0.3V/Series Q 值 S-F: 80 Ref. @ 125KHz/0.3V/Series D.C. Resistance S-F:250 mohm Max. Dimensions (Units:mm Unless otherwise specified, all tolerances are±0.25 ) Schematic Package info LRC0027-50X – Plastic bag 42.0 Max. 12.6 Ref. 4.0 Ref. 55.0 Typ. 10.0 Ref. TUBE Preliminary SPEC
Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 20 of 46 Set Up Photo of Radiated Emission EMI BLE Charge Below 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 21 of 46 Above 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 22 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 23 of 46 Battery Below 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 24 of 46 Above 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 25 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 26 of 46 RX 315MHz Charge Below 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 27 of 46 Above 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 28 of 46 Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 29 of 46 Battery Below 1GHz Registration number: W6M22404-23411-FCC FCC ID: HQXTT03 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 30 of 46 Above 1GHz…
Text truncated - open the document above for the full version.
6F., No.58, Lane 188, Ruey Kuand Rd., · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
TPMS
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
TPMS-VALVE ASSY, BLE
Equipment Class
DTS - Digital Transmission System
TPMS
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS Trigger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Voice Dongle
Equipment Class
DTS - Digital Transmission System