FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hunter Fan Company/
  3. IN2TX26

IN2TX26Ceiling Fan/Lamp RF Remote Control

Hunter Fan Company
Ceiling Fan/Lamp RF Remote Control - FCC ID IN2TX26 - Hunter Fan Company
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 10, 2007
Application Purpose
Original Equipment
Date of Application
Jan 10, 2007
Equipment Note
Ceiling Fan/Lamp RF Remote Control
Frequency Range
350.00000000 - 350.00000000
Company
Hunter Fan Company
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

External Photos

โ†—
โ†—

ID Label/Location Info

โ†—
โ†—

Internal Photos

โ†—
โ†—

Operational Description

โ†—

Schematics

โ†—
โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—
โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Hunter ON/OFF Fan & Light Control Model 27157 Ratings: 120 VAC, 60 Hz,1.0 Amp Fan Receiver Weight: 6 oz. 300 Watts incandescent light Read and Save these Instructions Caution: Risk of Electrical Shock! All wiring must be performed in accordance with national and local electrical codes. If you are unfamiliar with the wiring codes, you should use a qualified electrician. To avoid overheating and possible damage to other equipment, do not install to control a receptacle, fluorescent light fixture, motor operated appliance, or transformer-supplied appliance. Use only to control one paddle-blade ceiling fan and incandescent light fixture. Notes: 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfer- ence by one or more of the following measures: โ€ข Reorient or relocate the receiving antenna. โ€ข Increase the separation between the equipment and receiver. โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. โ€ข Consult the dealer or an experienced radio/TV technician for help. 3. For use only with electrically reversible ceiling fans rated at 1.0 amp or less, and fan incandescent light kits rated at 300 watts or less. 4. Not for use with shaded-pole motors. Not recom- mended for use with the Hunter Originalยฎ. For Hunter Originalยฎ series fans, use Hunter control model numbers 27187, 22691, or 27189. 5. Medium and Low fan speeds are determined by the fan pull chain switch and thus may vary from the factory settings due to normal motor variations. 6. This product is intended for use with a single switch. If more than one switch is being used to control the fixture, consult a qualified electrician for assistance. Any changes or modifications to this equipment not expressly approved by Hunter Fan Company will void the userโ€™s authority to operate the equipment. Before Installing the Control: 1. Use the pull-chain switch on the fan to set the fan speed to the HIGH position before installation. 2. Set the ceiling fan light kit to the ON position before installation. The light setting should only be changed by the Hunter control. Receiver Installation: 1. Disconnect power to the ceiling fan and light kit at the main electrical panel. Remove fuse or move circuit breaker to the OFF position. 2. IMPORTANT! Before installing this control, check the factory default dip switch settings. Refer to Figure 1. Be sure the dip switch positions of the transmitter and receiver match, or the ceiling fan will not function. Select different combinations of dip switches to prevent mis-operation due to other remote control fans. 3. Determine your ceiling fan mounting type (Figure 2). Most installa- tions will be one of these four types: Canopy Hanger, Hunter Hands-Free TM Canopy, Low Profile Styles I and II, or Bracket Hanger. 4. Install the ceiling fan according to its instructions, up to the point of making the electrical connections. Connect receiver to ceiling fan accord- ing to the mounting type as instructed in Figure 2. 5. If the fan is already installed, turn the power OFF at the main electrical panel. Reverse the installation procedure according to the fan instructions, to the point of disconnecting the fan wiring. Connect the receiver to the ceiling fan according to the mounting type as instructed in Figure 2. 6. Use the 2 large wire nuts supplied to connect the receiver and house wiring, then use the 3 small wire nuts supplied to connect the receiver and ceiling fan wiring. Refer to the Wiring Diagram in Figure 3. 7. Be sure the antenna is positioned securely, so it can not interfere with the ceiling fan motor. Refer to Figure 2. Do not modify or damage the antenna wire, as control performance may be reduced. After securing the receiver, antenna, and wiring, finish hanging the ceiling fan according to its instructions. Fan Installation Types: NOTE: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire leaving a minimum of 6 inches remaining. Restrip the fan lead wires 1/2 inch. Place remaining excess wire into the ceiling electrical box as needed. Canopy Hanger (Fig. 2-A): Place receiver in canopy. Connect wiring as shown in Figure 3. Extend antenna through one of the ceiling plate open- ings (approximately 3โ€“6 ฬ‹). Hunter Hands-Freeโ„ข Canopy (Fig. 2-B): Connect wiring as shown in Figure 3. Place receiver inside mounting bracket. Extend antenna above the ceiling mounting bracket (approximately 3โ€“6 ฬ‹). Bracket Hanger (Fig. 2-C): Starting with the antenna wire, slide receiver inside mounting bracket. If a ground wire mounting screw prevents the receiver from sliding into the bracket, move ground wire and screw to an unused hole at the top of the bracket or secure with a canopy mount- ing screw. The bracket must remain properly grounded. Connect wiring as shown in Figure 3. Extend antenna above the receiver (approximately 5โ€“8 ฬ‹). 1. Light Operation: โ€ข Press and quickly release the ON or OFF button on the remote control to turn the light OFF or ON. (Light will come โ€ฆ

Text truncated - open the document above for the full version.

Block Diagram

2 SIMPLE ON & OFF (27157) Receiver โ€“ Controller Block Diagram D.Wilcher 7/19/06 AC-DC Power Supply 8-Bit Microcontroller Ceramic Resonator ID Jumpers Transient/Surge Suppression RF Module 350MHz RF Data +5VDC NPN Transistor Relay Driver Circuit Diode-Capacitor Relay-Coil Transient Suppression Circuit +24VDC - Tungsten Rated Electromechanical Relay NPN Transistor Relay Driver Circuit Diode-Capacitor Relay-Coil Transient Suppression Circuit +24VDC Electromechanical Relay +24VDC FAN ENABLE LAMP CTRL FAN ENABLE DRIVER CIRCUIT LAMP DRIVER CIRCUIT NEUTRAL LIVE COM 3 SIMPLE ON & OFF (27157) Transmitter โ€“ Controller Block Diagram D.Wilcher 7/19/06 6.8VDC Regulator Circuit Encoder IC Blue LED 3 Blue LED 2 SPST x4Switches RF Amplifier Circuit 350MHz SAW ID DIP SWITCHES X4 12VDC 6.8VDC Decoupling Capacitor LIGHT ON FAN ON LIGHT OFF FAN OFF

External Photos

Model 27157 Receiver โ€“ Front Model 27157 Receiver โ€“ Rear

External Photos

Model 27157 Transmitter (FCC ID: IN2TX26, IC: 3558A-TX26) โ€“ Front Note: Dimensions are 9.4 cm long and 4.0 cm wide. Model 27157 Transmitter (FCC ID: IN2TX26, IC: 3558A-TX26) โ€“ Rear

Internal Photos

Model 27157 Receiver โ€“ Expanded โ€“ Circuit Board Assembly with Plastic Case Model 27157 Receiver โ€“ Circuit Board โ€“ Component Side Model 27157 Receiver โ€“ Circuit Board โ€“ Solder Side

Internal Photos

Model 27157 Transmitter โ€“ Circuit Board โ€“ SAW Resonator/IC side with case Model 27157 Transmitter โ€“ Circuit Board โ€“ Keypad Side

Operational Description

Hunter simple ON-OFF combo Description of Operation Description: The top box of the diagram below represents all of the potential keys that may be pressed for the Hunter transmitter. 12VDC(23A) is supplied to the transmitter, Pressing Fan ON Button / Fan OFF Button / Light ON Button / Light OFF Button generates an encoded PCM code word which will modulate on a 350 MHz RF carrier for transmission. The encoded PCM code word is obtained from encode IC HT12E (U1) and is ASK modulated by the RF oscillator formed by transistor Q1. Antenna Loop Fan ON Button Fan OFF Button Light ON Button Light OFF Button U1 encode IC (HT12E) Q1 (MAR3838) ASK Modulator & Oscillator (350 MHz) Hunter simple ON-OFF combo Transmitter Coding Description: The Hunter transmitter uses the following code words to modulate on a 350 MHz RF carrier by using ASK modulation. Code words for the different commands: XXXXXXXX1000 XXXXXXXX0100 XXXXXXXX0010 XXXXXXXX0001 (Where โ€œxโ€ .) Code โ€œ0โ€ is represented as: Long pulse Code โ€œ1โ€ is represented as: Short pulse The timing of the pulses is detailed in the test report. Hunter simple ON-OFF combo Receiver Description of Operation Description: Refer to the block diagram of the Hunter receiver below. Power is supplied to the receiving and control circuits through a 5-Volt regulator U3, which is not shown in the diagram. Transistor Q1 is the front amplifier to amplify the signal received from the monopole antenna. Transistor Q2 is the super-regenerative receiving stage, whose frequency can be factory tuned by coil L2. Op- Amp U1 is configured as the detector. Microcontroller U2 converts the PCM data signal to performs the desired actions to control the fan and light. Monopole Antenna RF front Amp Q1 (MMBTH10LT1) Super-regenerative stage Q2 (MMBTH10LT1) Detector Op-amp U1 (LM358) Microcontroller U2 (S3F9454) Fan On/OFF Control Light On/OFF Control

Schematics

Simple ON OFF receiver schematic.sch-1 - Thu Jul 20 15:24:06 20 06 350MHz Receiver for simple ON-OFF control.sch-1 - Thu May 25 10 :50:49 2006

Schematics

simple ON-OFF TX-2 SCHEMATIC.sch-1 - Thu Jul 20 15:23:10 2006

Test Report

Project: 06CA38706 File: MC1324 Report: 060073 Date: August 7, 2006 Model: 27157 (Receiver) Test Report On Electromagnetic Compatibility Testing Hunter Fan Co Memphis, TN USA Copyright ๏›™ 2006 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 2 of 25 Test Report: 060073 Test Report Details: Tests Performed By: Underwriters Laboratories Inc. 12 Laboratory Drive Research Triangle Park, NC 27709 Tests Performed For: Hunter Fan Co 2500 Frisco Avenue Memphis, TN 38114 USA Applicant Contact: Mr. Robert Davis Safety and Test Engineer - International (901) 248-2212 (901) 248-2382 - FAX Test Report Number: 060073 Test Report Date: August 7, 2006 Product Type: Receiver/Controller for Ceiling Fan/Lamp Model Number: 27157 Sample Serial Number: None Sample Tag Number: 0776053-002 EUT Category: Receiver for Low-Powered Transmitter EUT Type: Ceiling Mounted Sample Receive Date: July 20, 2006 Testing Start Date: July 27, 2006 Date Testing Complete: July 28, 2006 Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report shall not be used to claim, constitute or imply product certification, approval, or endorsement by NVLAP or any agency of the US government. This report may contain test results that are not covered by the NVLAP accreditation. The scope of accreditation is limited to the specific tests that are listed on the NVLAP certificates provided at the end of this report. Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 3 of 25 Test Report: 060073 Summary of Testing: Test Test Name Comply Does Not See # Test Requirement/Specification Comply Remark 1 Radiated Disturbance Emissions - 30 to 1000 MHz Electric Field X - 47 CFR Part 15, Subpart B / 47 CFR Part 15, Subpart B, Class B 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.209 (General Limits) Industry Canada ICES-003 / Industry Canada ICES-003, Issue 4, Class B Industry Canada RSS-210 / Industry Canada RSS-210, Issue 6 (General Limits) 2 Radiated Disturbance Emissions - 1000 to 3500 MHz Electric Field X - 47 CFR Part 15, Subpart B / 47 CFR Part 15, Subpart B, Class B 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.209 (General Limits) Industry Canada ICES-003 / Industry Canada ICES-003, Issue 4, Class B Industry Canada RSS-210 / Industry Canada RSS-210, Issue 6 (General Limits) 3 Conducted Disturbance Emissions โ€“ 0.150 to 30 MHz X - 47 CFR Part 15, Subpart B / 47 CFR Part 15, Subpart B, Class B 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.207 (General Limits) Industry Canada ICES-003 / Industry Canada ICES-003, Issue 4, Class B Industry Canada RSS-210 / Industry Canada RSS-210, Issue 6 (General Limits) Remarks: 1) Modifications required to comply: None. 2) Compliance of transmitter is demonstrated in Test Report #060072. 3) All measurements were performed on Industry Canada registered site, IC-2953. Conclusion: The tests listed in the Summary of Testing section of this report have been performed and the results recorded by Underwriters Laboratories Inc. in accordance with the procedures stated in each test requirement and specification. The test list was determined by the Applicant as being applicable to the Equipment Under Test. As a result, the subject product has been verified to comply or not comply as noted in the Summary of Testing with each test specification. The test results relate only to the items tested. Prepared By: Reviewed By: Jim Marley Mark Nolting NARTE Certified EMC Engineer NARTE Certified EMC Test Lab Engineer [email protected] [email protected] (919) 549-1408 (919) 549-1584 Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 4 of 25 Test Report: 060073 Test Facilities: Test Location A) 10-Meter Anechoic Chamber (Industry Canada - IC 2953, VCCI - R-722/C-2427) Constructed by Lindgren RF Enclosures, this room consists of a 17.9 by 12 by 8.3 m (inside clearance) shielded room lined with TDK absorber material. The walls, floor (conducting ground plane) and ceiling are constructed of double sided galvanized sheet steel supported by 19 mm thick particle board. The interior walls and ceiling are covered with 10 by 10 cm, 4.6 mm thick ferrite tiles and partially covered with polystyrene absorber cones. Removable floor tiles and cones covering the floor between the EUT and antenna are provided when RF immunity testing is performed. Room is provided with a 4.0 m diameter embedded turntable and a 1.2 by 2.1 m and 2.4 by 2.4 m double knife edge doors for access. Also, the room is fed electrical EUT power via permanently installed filters and is provided with a permanently mounted video surveillance camera. A remotely controllable antenna mast is located in the room for positioning the measuring antenna from 1 to 4 m above the ground plane. Test Location B) Compact Anechoic Chamber Constructed by Lindgren RF Enclosures, this room consists of a 6 by 3 by 2.9 m (inside clearance) shielded room lined with TDK absorber material. The walls, floor, and ceiling are constructed of double sided galvanized sheet steel supported by 19 mm thick particle board. The interior walls and ceiโ€ฆ

Text truncated - open the document above for the full version.

Test Report

Project: 06CA38706 File: MC1324 Report: 060072 Date: August 7, 2006 Model: 27157 Low Power Transmitter (FCC ID: IN2TX26 IC: 3558A-TX26) Test Report On Electromagnetic Compatibility Testing Hunter Fan Co Memphis, TN USA Copyright ๏›™ 2006 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 2 of 44 FCC ID: IN2TX26 Test Report: 060072 IC: 3558A-TX26 Test Report Details: Tests Performed By: Underwriters Laboratories Inc. 12 Laboratory Drive Research Triangle Park, NC 27709 Tests Performed For: Hunter Fan Co 2500 Frisco Avenue Memphis, TN 38114 USA Applicant Contact: Mr. Robert Davis Safety and Test Engineer - International (901) 248-2212 (901) 248-2382 - FAX Test Report Number: 060072 Test Report Date: August 7, 2006 Product Type: Low Powered Transmitter Model Number: 27157 Sample Serial Number: 333 1968 426 Sample Tag Number: 0776053-001 EUT Category: Transmitter - Low Powered EUT Type: Hand Held Sample Receive Date: July 20, 2006 Testing Start Date: July 28, 2006 Date Testing Complete: July 30, 2006 Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report shall not be used to claim, constitute or imply product certification, approval, or endorsement by NVLAP or any agency of the US government. This report may contain test results that are not covered by the NVLAP accreditation. The scope of accreditation is limited to the specific tests that are listed on the NVLAP certificates provided at the end of this report. Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 3 of 44 FCC ID: IN2TX26 Test Report: 060072 IC: 3558A-TX26 Summary of Testing: Test Test Name Comply Does Not See # Test Requirement/Specification Comply Remark 1 Radiated Disturbance Emissions - 30 MHz to 3500 MHz X - 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.209 and 15.231 Industry Canada RSS-210 Issue 6 / Industry Canada RSS-210 Issue 6 2 Occupied Bandwidth X - 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.231 Industry Canada RSS-210 Issue 6 / Industry Canada RSS-210 Issue 6 3 Peak-to-Average Ratio N/A N/A 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.231 Industry Canada RSS-210 Issue 6 / Industry Canada RSS-210 Issue 6 4 Radiated Disturbance Emissions - Restricted Bands X - 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.205 Industry Canada RSS-210 Issue 6 / Industry Canada RSS-210 Issue 6, Section 2.6 4 Holdover Time โ€“ Manually Activated Transmitter X 47 CFR Part 15, Subpart C / 47 CFR Part 15, Subpart C, Section 15.231 Industry Canada RSS-210 Issue 6 / Industry Canada RSS-210 Issue 6, Annex 1, A1.1.1 Remarks: 1) Antenna - This transmitter contains an integrated antenna that cannot be removed by the user. 2) Measurement Site & Accreditations - All measurements were performed on Industry Canada registered site IC-2953. All measurements were performed in accordance with NVLAP-accredited procedures. 3) RF Exposure - This device is exempt from routine evaluation to RF exposure requirements per FCC Part 2.1091. Output power is 12.8 uW EIRP (avg), therefore device is exempt from routine evaluation per Industry Canada RSS-102 Issue 2, Section 2.5.1. 4) Momentary Operation Requirements โ€“ It was observed that transmissions ceased immediately upon release of button (< 200 ms). This meets the holdover limit of five seconds or less found in FCC Part 15.231(a)(1) and Industry Canada RSS-210 Issue 6, Annex 1, Section A1.1.1 for manually activated transmitters. No periodic or automatically activated emissions requirements apply. 5) Canada Emissions Designator โ€“ Emissions Designator is L1D44K1. 6) Receiver โ€“ Associated receiver was tested separately. Results documented in report 060073. 7) Transmitter Dimensions โ€“ Transmitter measures 3.6โ€ x 1.5โ€ at the longest/widest points. Due to the size and curvature of the plastic, the manufacturer could not legibly fit the FCC Part 15 statement on the device. The FCC ID number is placed on the transmitter and the FCC Part 15 statement is moved to the user manual. Conclusion: The tests listed in the Summary of Testing section of this report have been performed and the results recorded by Underwriters Laboratories Inc. in accordance with the procedures stated in each test requirement and specification. The test list was determined by the Applicant as being applicable to the Equipment Under Test. As a result, the subject product has been verified to comply or not comply as noted in the Summary of Testing with each test specification. The test results relate only to the items tested. Prepared By: Reviewed By: Jim Marley Mark Nolting NARTE Certified EMC Engineer NARTE Certified EMC Test Lab Engineer [email protected] [email protected] (919) 549-1408 (919) 549-1584 Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 4 of 44 FCC ID: IN2TX26 Test Report: 060072 IC: 3558A-TX26 Test Facilities: Test Location A) 10-Meter Anechoic Chamber (Industry Canada - IC 2953, VCCI - R-722/C-2427) Constructed by Lindgren RF Enclosures, this room consists of a 17.9 by 12 by 8.3 m (inside clearance) shielded room lined with TDK absorber materโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 1 of 1 27157 Receiver Test 3, Item A - Test Setup Photo (Worst-case emissions): Conducted Disturbance Emissions โ€“ 150 kHz to 30 MHz

Test Setup Photos

Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 1 of 2 27157 (Receiver) Test 1, Item B - Test Set-Up Photo - Maximum Emissions Configuration: Radiated Disturbance Emissions - 30 to 1000 MHz Electric Field Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 04/27/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 2 of 2 Test Report: 060073 Test 1, Item B - Test Set-Up Photo - Maximum Emissions Configuration: Radiated Disturbance Emissions - 30 to 1000 GHz Electric Field

Test Setup Photos

Project: 06CA38706 Underwriters Laboratories, Inc. Issued: 08/07/06 File: MC1324 Test Report on Electromagnetic Compatibility Page 1 of 1 FCC ID: IN2TX26 Test Report: 060072 IC: 3558A-TX26 Test 1, Item B (Side Orientation โ€“ Worst-Case Orientation) - Test Set-Up Photo: Radiated Disturbance Emissions - 30 MHz to 3500 MHz

Contact Information

Applicant

Julian A Martin(Compliance Manager)
[email protected](901)248-2810Fax: (901)248-2382

Technical Contact

Hunter Fan CompanyRaobert Davis
[email protected]901-248-2212

2500 Frisco Ave ยท Memphis, Tennessee ยท United States

Test Firm

UL LLCRick Titus
[email protected]847-664-3281Fax: 847-509-6321

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
115.231350 MHz - 350 MHz-L1D41K2

Other Applications from Hunter Fan Company

Remote Control for Ceiling Fan - FCC ID IN2TX61 - Hunter Fan Company
IN2TX61

Remote Control for Ceiling Fan

Sep 11, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX57 - Hunter Fan Company
IN2TX57

Remote Control for Ceiling Fan

Jul 03, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX52 - Hunter Fan Company
IN2TX52

Remote Control for Ceiling Fan

Jan 10, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX50 - Hunter Fan Company
IN2TX50

Remote Control for Ceiling Fan

Jul 29, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control for ceiling fan - FCC ID IN2TX49 - Hunter Fan Company
IN2TX49

Remote control for ceiling fan

Jun 14, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter