www.HunterFan.com 1.888.830.1326 Model #99116 Universal Ceiling Fan Remote Control Installation Wiring OROROR Remove the canopy. If uncertain how to remove it, reference the fan’s owner’s manual. With wiring exposed, it may be helpful to note existing wire connections or take a digital photo for reference. Remove the wire connectors that connect the wires from the outlet box to the fan, leaving the grounding wires connected. CONNECT WIRES FROM RECEIVER TO FAN -Using the blue wire connectors connect the white wire from the receiver (marked “common out”) to the white wire from fan. Connect the black wire from the receiver (marked “fan out”) to the black wire from the fan. Connect the blue wire from the receiver (marked ”light out”) to the blue wire (or possibly black with white stripe) from the fan. If you’re uncertain about wire colors or connections, please contact a qualified electrician. CONNECT WIRES FROM RECEIVER TO WIRES FROM OUTLET BOX - Using an orange wire connector connect the black wire (ungrounded) from the ceiling to the black wire from the receiver (marked “live in”). Connect the white wire (grounded) from the ceiling to the white wire from the receiver (marked “neutral in”). AFTER ALL WIRES ARE CONNECTED and secured with wire connectors, re-install the canopy. Before installing the Universal Remote Control Receiver, use the pull chains to set the fan speed to HIGH and the light to ON. Be sure power is OFF before proceeding with installation. Choose the hanging system that most closely resembles the one used by your fan and install the receiver and wire as directed. Note: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire, leaving a minimum of 8” remaining. Re-strip the fan lead wires 1/2”. Place remaining excess wire into the ceiling electrical box. The bracket and fan must remain properly grounded. You may have installation issues if the fan is installed on an angled ceiling. Ceiling Plate Receive r Canopy Receiver Canopy Ceiling Bracket Receiver Fan Body Cable Tie For low prole fans, the receiver should be secured to the hanger bracket with a cable tie. Receiver Canopy Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel. F R O M R E C E I V E R F R O M C E I L I N G black (live in) white (neutral in)white (grounded) black (ungrounded) F R O M R E C E I V E R white black blue white (common out) black (fan out) blue (light out) F R O M F A N M0041-01 • 11/08/12 • © Hunter Fan Company OFF Turn Po wer www.HunterFan.com 1.888.830.1326 TroubleshootingSafe-Exit If you have problems installing or operating your fan, do not return this product to the dealer. Call our Consumer Affairs Hotline. 888-830-1326 Monday through Friday 8 am to 4:30 pm Central This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 1. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Note: Any changes or modifications to the transmitter or receiver not expressly approved by Hunter Fan Company may void one’s authority to operate this remote control. Read and Save These Instructions This product conforms to UL Standard 507. WARNINGS Fan will not start • Make sure the power is on at the circuit breaker and the wall switch. • Make sure the battery is working. • Make sure that the transmitter and receiver are paired. • Check wire connections inside of the canopy. Transmitter only works when held at close range • Change battery. Lights do not dim • Check to see if a CFL bulb is installed. The control has a feature that automatically detects CFL bulbs and turns off dimming if a CFL bulb is installed. Remote control of fan is erratic • Make sure battery is installed correctly. • Install a fresh battery. The Fan Off button only turns the fan off. To turn the fan on, press one of the fan speed buttons. They are located under the Fan Off button. High Medium Low Pairing Within 3 minutes of restoring power to the fan, press both the Fan Off button and the High button for at leas…
Text truncated - open the document above for the full version.
HOME COMFORT Hunter Fan and Light Remote Control Block Diagram and Operational Description Description: The top box of the diagram below represents all of the potential keys that may be pressed for Hunter 99116 Transmitter. Pressing any key generates an encoded PCM code word which will modulate on a 434 MHZ RF carrier for transmission. The encoded PCM code word is obtained from encode U1 and is ASK modulated by the RF oscillator formed by transistor Q1. Encoder U1 also provides selectable security bits which can be set by the user. The frequency is obtained by Capacitor C6 to 434 MHZ. Light Button Speed 1Speed 2Speed 3 Off Button U1 ENCODER (AS-12E) Q1 (MMBTH10)ASK Modulator and Oscillator 434MHZFactory tuned b y C5 Antenna Loop
HOME COMFORT Hunter Fan and Light Remote Control Block Diagram and Operational Description Description: The top box of the diagram below represents all of the potential keys that may be pressed for Hunter 99116 Transmitter. Pressing any key generates an encoded PCM code word which will modulate on a 434 MHZ RF carrier for transmission. The encoded PCM code word is obtained from encode U1 and is ASK modulated by the RF oscillator formed by transistor Q1. Encoder U1 also provides selectable security bits which can be set by the user. The frequency is obtained by Capacitor C6 to 434 MHZ. Light Button Speed 1Speed 2Speed 3 Off Button U1 ENCODER (AS-12E) Q1 (MMBTH10)ASK Modulator and Oscillator 434MHZFactory tuned b y C5 Antenna Loop
1 1 2 2 3 3 4 4 DD CC BB AA Title NumberRevisionSize Letter Date:10/18/2012Sheet of File:C:\Users\..\HD_3_Speed_V0p4.SchDocDrawn By: 100nH C1 Ind 0603 GND +3v GND DNI L1 +3V GND +3v GND GND GND GND Speed0 100nF C7 Cer Cap 0603 GND 100pF C5 Cer Cap 0603 100nF C2 Cer Cap 0603 100nF C3 Cer Cap 0603 100nF C6 Cer Cap 0603 Speed1 Speed3 Speed4 Light_Off Reverse Speed1 Speed3 Speed4 Light_Off Reverse Home Depot Remote XXXXXXX 3V CR2032 Ichiro Aoki Ver 0p3 AyDeeKay LLC +1.8V SWCLK SWDIO P9 1 P8 2 P7 3 P6 4 P5 5 GND 0 TMS 6 SWCLK 7 SWDIO 8 V1V8 9 VBAT 10 P2 11 P1 12 P0 13 RFOUT 14 VQP 15 C2 16 C1 17 P11 18 P10 19 XTAL 20 U1 HeimdallS Rf VQP LightToggle LightToggle BT1 Battery_CR2032 GND Antenna 10nH C4 Ind 0603 0 ohm L4 Cer Cap 0603 15nH L3 0 ohm C10 Cer Cap 0603 GND 10pF L2 DNI C11 Cer Cap 0603 100pF C12 Cer Cap 0603 C11 Near IC C12 near switch 10pF C15 Cer Cap 0603 DNI C16 Cer Cap 0603 100pF C17 Cer Cap 0603 C16 Near IC C17 near switch 100pF C18 Cer Cap 0603 DNI C20 Cer Cap 0603 SWCLK SWDIO 1 2 3 4 609-3248-ND DNI P1 TEST HEADER +3V GND GND 100pF C21 Cer Cap 0603 100pF C23 GND DNI C24 Cer Cap 0603 Speed1Speed3Speed4Light_Off DNI C19 Cer Cap 0603 30MHz crystal X1 HC49SM SMD FAN_OFF smd_Hunter_9p0x6p0x4p3 100pF C8 Cer Cap 0603 DNI C14 Cer Cap 0603 GND FAN_LOW smd_Hunter_9p0x6p0x4p3 FAN_MED smd_Hunter_9p0x6p0x4p3 FAN_HI smd_Hunter_9p0x6p0x4p3 Speed0 NOTE: SPEED0 moved to reduce likelihood Speed0 of Spuriouis RF Emissions 100pF C25 Cer Cap 0603 DEBUG CONNECTOR GND LIGHT_OFF smd_Hunter_9p0x6p0x4p3 PIAntenna01 COAntenna PIBT101 PIBT102 COBT1 PIC101 PIC102 COC1 PIC201 PIC202 COC2 PIC301 PIC302 COC3 PIC401PIC402 COC4 PIC501 PIC502 COC5 PIC601PIC602 COC6 PIC701 PIC702 COC7 PIC801 PIC802 COC8 PIC1001 PIC1002 COC10 PIC1101 PIC1102 COC11 PIC1201 PIC1202 COC12 PIC1401 PIC1402 COC14 PIC1501 PIC1502 COC15 PIC1601 PIC1602 COC16 PIC1701 PIC1702 COC17 PIC1801 PIC1802 COC18 PIC1901 PIC1902 COC19 PIC2001 PIC2002 COC20 PIC2101 PIC2102 COC21 PIC2301 PIC2302 COC23 PIC2401 PIC2402 COC24 PIC2501 PIC2502 COC25 PIFAN0HI01PIFAN0HI02 PIFAN0HI03PIFAN0HI04 COFAN0HI PIFAN0LOW01PIFAN0LOW02 PIFAN0LOW03PIFAN0LOW04 COFAN0LOW PIFAN0MED01PIFAN0MED02 PIFAN0MED03PIFAN0MED04 COFAN0MED PIFAN0OFF01PIFAN0OFF02 PIFAN0OFF03PIFAN0OFF04 COFAN0OFF PIL101 PIL102 COL1 PIL201 PIL202 COL2 PIL301 PIL302 COL3 PIL401PIL402 COL4 PILIGHT0OFF01PILIGHT0OFF02 PILIGHT0OFF03PILIGHT0OFF04 COLIGHT0OFF PIP101 PIP102 PIP103 PIP104 COP1 PIU100 PIU101 PIU102 PIU103 PIU104 PIU105 PIU106PIU107PIU108PIU109PIU1010 PIU1011 PIU1012 PIU1013 PIU1014 PIU1015 PIU1016PIU1017PIU1018PIU1019PIU1020 COU1 PIX101PIX102 COX1 PIC301 PIU109 NL0108V PIBT101 PIC101 PIC201PIC501PIC701 PIL102 PIP101 PIU1010 NL03V PIBT102 PIC202 PIC302 PIC502PIC702 PIC801 PIC1001 PIC1101PIC1201 PIC1401 PIC1601PIC1702PIC1801PIC1901PIC2002PIC2101 PIC2301 PIC2401 PIC2501 PIFAN0HI03 PIFAN0LOW03 PIFAN0MED03 PIFAN0OFF03 PILIGHT0OFF03 PIP102 PIU100PIU106 PIU1012 PIU1013 PIX102 PIC2402 PIC2502 PILIGHT0OFF02 PIU102 NLLight0Off PIU1019 NLLightToggle PIAntenna01 PIC1402 PIC1502PIL302 PIL402PIC402PIL401 PIC601 PIU1017 PIC602 PIU1016 PIC802 PIC1501 PIL301 PIC1002 PIL201 PIFAN0HI01 PIFAN0HI04 PIFAN0LOW01 PIFAN0LOW04 PIFAN0MED01 PIFAN0MED04 PIFAN0OFF01 PIFAN0OFF04 PILIGHT0OFF01 PILIGHT0OFF04 PIU1018PIU1020 PIX101 PIU101 NLReverse PIC102 PIC401 PIL101 PIL202 PIU1014 NLRf PIC1102PIC1202 PIFAN0OFF02 PIU1011 NLSpeed0 PIC1602PIC1701 PIFAN0LOW02 PIU103 NLSpeed1 PIC1802PIC1902 PIFAN0MED02 PIU105 NLSpeed3 PIC2001PIC2102 PIFAN0HI02 PIU104 NLSpeed4 PIP104 PIU107 NLSWCLK PIP103 PIU108 NLSWDIO PIC2302 PIU1015 NLVQP
Client: Product Designation: 99116 Report Number: 100937514ATL-001 All services undertaken are subject to the following general policy: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST, or any agency of the US Government. Tested by: Tests performed by:Report reviewed by: Standard: Jeremy O. Pickens Senior Staff Engineer Troy Ihle EMC Project Engineer Hunter Fan 7130 Goodlett Farms Pkwy, Ste 400 Memphis, TN 38016 Contact: Robert Davis Phone: (901) 248-2212 Fax: (901) 248-2382 E-mail: [email protected] TEST REPORT October 30, 2012 Intertek Testing Services NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 47 CFR Part 15, Subpart C (15.231 - Periodic operation in the band 40.66- 40.70 MHz and above 70 MHz) RSS-210, Issue 8, 2010 Page 1 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek 2.0 Test Summary 1.0 Introduction and Conclusion Test DateTest Full NameResultSection System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup)4.0 Overview of EUT (Low Power Transmitters) (EUT Overview)5.0 Restrictions (FCC 15C-15.231 / RSS-210 A1.1)6.0 10/23/2012Duty Cycle Determination (FCC 15A-15.35(c) / RSS-GEN 4.5)7.0 10/25/2012Radiated Emissions (FCC 15.231(b) / RSS-210 A1.1.2)PASS8.0 10/25/2012Bandwidth Requirements (FCC 15.231(c) / RSS-210 A1.1.3)PASS9.0 Conducted emissions on AC power lines (Conducted Emissions) was waived due to the EUT was powered by battery.NA Conducted Emissions for Intentional Radiators (FCC 15.207 / RSS-GEN 7.2.4) was waived due to the device was battery-powered. NA The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatum text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Page 2 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek 3.0 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number Ceiling Fan Remote Hunter Fan 99116 N/A EUT receive date: October 24, 2012 EUT receive condition: Good Description of EUT provided by Client: The EUT was a hand held wireless transmitter used for remote control of a ceiling fan and light assembly. Description of EUT exercising: During testing, the device was powered from a new internal CR2032 battery and configured to transmit continuously. Page 3 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) 4.0 Method: Record the details of EUTcabling, document the support equipment, and show the interconnections in a block diagram. Data: EUT Setup Diagram Drawing: Page 4 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) 4.0 None Support Equipment DescriptionManufacturerModel NumberSerial Number None Description EUT Cabling Connection Length Shielding FerritesIDFromTo Page 5 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek Overview of EUT (Low Power Transmitters) (EUT Overview)5.0 Method: Complete the overview spreadsheet. Related Submittal(s) Grants: This report is for use with an application for certification of a low power transmitter. One transmitter is included in the application. Page 6 of 34 EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek Overview of EUT (Low Power Transmitters) (EUT Overview)5.0 Hunter Fan Company 7130 Go o d lett Parkway , Su ite 400 M emp h is , TN 38016 Trad e Name & M o d el No . 99116 FCC Identifier IN2TX36 IC Id en tifier 3558A -TX36 Frequency Range (MHz) 434 A n ten n a Ty p e (15.203) In teg ral Manufacturer name & address Shenzhen H and T Intelligent Control Co.,Ltd Shenzhen , Guangdong, CHINA Additions, deviations and exclusions from standards None This report is for use with an application for certification of a low power transmitter. One transmitter is included in the application. Applicant Related Submittals and Grants: Data: Page 7 of 34EMC Report for Hunter Fan on the 99116 10/30/2012Report Number: 100937514ATL-001Issued: Intertek Restrictions (FCC 15C-15.231 / RSS-210 A1.1)6.0 Method: 15.231(a) The provisions of this section are restricted to periodic operation within the band 40.66-40.70 MHz…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 434 MHz - 434 MHz | - |

Remote Control for Ceiling Fan
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote control for ceiling fan
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter