FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hunter Fan Company/
  3. IN2TX42

IN2TX42Remote Control for Ceiling Fan

Hunter Fan Company
Remote Control for Ceiling Fan - FCC ID IN2TX42 - Hunter Fan Company
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 06, 2013
Application Purpose
Original Equipment
Date of Application
Mar 06, 2013
Equipment Note
Remote Control for Ceiling Fan
Frequency Range
434.00000000 - 434.00000000
Company
Hunter Fan Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Care and CleaningPre-Installation Item #000-000 Model #99110 USE AND CARE GUIDE UNIVERSAL CEILING FAN REMOTE CONTROL Warranty 1-YEAR LIMITED WARRANTYWHAT IS COVEREDThe manufacturer makes the following limited warranty to the original purchaser of the remote control: Your remote control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale. If the remote control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace it free of charge. If the original purchaser ceases to own the remote control, this warranty and any implied warranty, including but not limited to any implied warranty of merchantability or fitness for a particular purpose, are voided. This warranty is in lieu of all other express warranties. The duration of any implied warranty, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, in respect to any control, is expressly limited to the period of the express warranty set forth above for such control.WHAT IS NOT COVEREDThis warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation, modifications, or damage to the remote control while in your possession, or unreasonable use. This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries. In no event shall the manufacturer be liable for consequential or incidental damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state . Questions, problems, missing parts? Before returning to the store, call Customer Service 9 a.m.-5:30 p.m., EST, Monday-Friday 1-888-830-1326 WWW.HOMEDEPOT.COM To clean, use soft brushes or cloths to prevent scratching. Cleaning products may damage finishes. Installation  Before installation, use the pull chains to set the fan speed to HIGH and the light to ON.  Ensure the power is OFF before proceeding with installation.  Using the blue wire connectors (D), connect the white wire from the receiver (A) (marked “common out”) to the white wire from the fan. Connect the black wire from the receiver (A) (marked “fan out”) to the black wire from the fan. Connect the blue wire from the receiver (A) (marked ”light out”) to the blue wire (or possibly black with white stripe) from the fan. OF F Turn Po we r 2 72 1 5 31 6 4  Remove the canopy by following the instructions supplied by the fan manufacturer.  Press one of the fan speed buttons (located under the Fan Off button) to turn the fan on. Press the Fan Off button to turn the fan off. High Medium Low  Quickly press the Light button to turn the lights off and on. Hold the Light button to raise and dim the light level.  Your remote control comes with a wall mount (C) that has two posts to mount your remote control (B) when not in use.  Turn on the power.  Within three minutes of restoring power to the fan, press both the Fan Off button and the High button for at least four seconds. The remote control (B) is now paired to the fan’s receiver (A).  To access the battery compartment, remove the small Phillips head screw that secures the battery door to the remote control (B).  Replace the used battery with a CR2032 battery (G) when necessary. The battery should be installed with the positive (+) side up.  Using an orange wire connector (D), connect the black wire (ungrounded) from the ceiling to the black wire from the receiver (A) (marked “live in”). Connect the white wire (grounded) from the ceiling to the white wire from the receiver (A) (marked “neutral in”).  After all wires are connected and secured with wire connectors (D), re-install the canopy. Turning off the power Installing the battery Wiring the receiver to the fan Installing the receiver Removing the canopy Pairing the remote control and receiver Wiring the receiver to the ceiling F R O M R E C E I V E R F R O M C E I L I N G black (live in)white (neutral in) (grounded) black (ungrounded) Phillips Head ScrewBattery Door Fan Off High ooo oo o Low Medium High Fan Off Light Post TOOLS REQUIRED PACKAGE CONTENTS A B G F E C D  Hold the Fan Off button for at least three seconds to initiate the Safe Exit program. The lights will stay on 50% brightness for 15 seconds and then begin to dim. After a total of 30 seconds, the lights will be completely off. F R O M R E C E I V E R whiteblack blue white (common out)black (fan out)blue (light out) F R O M F A N CR 2032 NOTE: Parts not shown to actual size. NOTE: If you’re uncertain about wire colors or connections, please contact a qualified electrician. A B B BC B D A D Operation NOTE: The remote control must be paired before the fan will operate.NOTE: If using the remote with multiple fans, repeat this process for each fan. NOTE: The Safe Exit program gives you about thirty seconds of light, when you turn the lights off, to exit the room before the lights go out.NOTE: For CFL lighting, the lights will stay on 100% brightness for 30 seconds. After a total of 30 seconds, the lights will be completely off. Part Description Quantity A Receiver 1 B Remote Control 1 C Remote Control Mount 1 D Wire Connectors 5 E Long Fasteners 2 F Short Fasteners 2 G Battery 1 Ladder Pliers Flat Blade Screwdriver Phillips Screwdriver Safety InformationTroubleshooting NOTE: This product conforms to UL Standard 507. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can rad…

Text truncated - open the document above for the full version.

Block Diagram

HOME COMFORT Hunter Fan and Light Remote Control Block Diagram and Operational Description Description: The top box of the diagram below represents all of the potential keys that may be pressed for Hunter 991 21 Transmitter. Pressing any key generates an encoded PCM code word which will modulate on a 434 MHZ RF carrier for transmission. The encoded PCM code word is obtained from encode U1 and is ASK modulated by the RF oscillator formed by transistor Q1. Encoder U1 also provides selectable security bits which can be set by the user. The frequency is obtained by Capacitor C6 to 434 MHZ. Light Button Speed 1Speed 2Speed 3 Off Button U1 ENCODER (AS-12E) Q1 (MMBTH10)ASK Modulator and Oscillator 434MHZFactory tuned b y C5 Antenna Loop

Cover Letter(s)

Letter of Agency I appoint Intertek Testing Services NA Inc. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under the FCC rules until further notice. I further certify that no party (as defined in 1.2002 of CFR 47, 1995) to this application, including myself, is subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,862. Equipment: Remote 99121 (IN2TX42) Dated this 22 nd day of February, 2013 Signature Robert Davis Name Manager of Compliance and Controls Title Hunter Fan Company Company 901-248-2212 Telephone

Operational Description

HOME COMFORT Hunter Fan and Light Remote Control Block Diagram and Operational Description Description: The top box of the diagram below represents all of the potential keys that may be pressed for Hunter 991 21 Transmitter. Pressing any key generates an encoded PCM code word which will modulate on a 434 MHZ RF carrier for transmission. The encoded PCM code word is obtained from encode U1 and is ASK modulated by the RF oscillator formed by transistor Q1. Encoder U1 also provides selectable security bits which can be set by the user. The frequency is obtained by Capacitor C6 to 434 MHZ. Light Button Speed 1Speed 2Speed 3 Off Button U1 ENCODER (AS-12E) Q1 (MMBTH10)ASK Modulator and Oscillator 434MHZFactory tuned b y C5 Antenna Loop

Schematics

1 1 2 2 3 3 4 4 DD CC BB AA Title NumberRevisionSize Letter Date:10/18/2012Sheet of File:C:\Users\..\HD_3_Speed_V0p4.SchDocDrawn By: 100nH C1 Ind 0603 GND +3v GND DNI L1 +3V GND +3v GND GND GND GND Speed0 100nF C7 Cer Cap 0603 GND 100pF C5 Cer Cap 0603 100nF C2 Cer Cap 0603 100nF C3 Cer Cap 0603 100nF C6 Cer Cap 0603 Speed1 Speed3 Speed4 Light_Off Reverse Speed1 Speed3 Speed4 Light_Off Reverse Home Depot Remote XXXXXXX 3V CR2032 Ichiro Aoki Ver 0p3 AyDeeKay LLC +1.8V SWCLK SWDIO P9 1 P8 2 P7 3 P6 4 P5 5 GND 0 TMS 6 SWCLK 7 SWDIO 8 V1V8 9 VBAT 10 P2 11 P1 12 P0 13 RFOUT 14 VQP 15 C2 16 C1 17 P11 18 P10 19 XTAL 20 U1 HeimdallS Rf VQP LightToggle LightToggle BT1 Battery_CR2032 GND Antenna 10nH C4 Ind 0603 0 ohm L4 Cer Cap 0603 15nH L3 0 ohm C10 Cer Cap 0603 GND 10pF L2 DNI C11 Cer Cap 0603 100pF C12 Cer Cap 0603 C11 Near IC C12 near switch 10pF C15 Cer Cap 0603 DNI C16 Cer Cap 0603 100pF C17 Cer Cap 0603 C16 Near IC C17 near switch 100pF C18 Cer Cap 0603 DNI C20 Cer Cap 0603 SWCLK SWDIO 1 2 3 4 609-3248-ND DNI P1 TEST HEADER +3V GND GND 100pF C21 Cer Cap 0603 100pF C23 GND DNI C24 Cer Cap 0603 Speed1Speed3Speed4Light_Off DNI C19 Cer Cap 0603 30MHz crystal X1 HC49SM SMD FAN_OFF smd_Hunter_9p0x6p0x4p3 100pF C8 Cer Cap 0603 DNI C14 Cer Cap 0603 GND FAN_LOW smd_Hunter_9p0x6p0x4p3 FAN_MED smd_Hunter_9p0x6p0x4p3 FAN_HI smd_Hunter_9p0x6p0x4p3 Speed0 NOTE: SPEED0 moved to reduce likelihood Speed0 of Spuriouis RF Emissions 100pF C25 Cer Cap 0603 DEBUG CONNECTOR GND LIGHT_OFF smd_Hunter_9p0x6p0x4p3 PIAntenna01 COAntenna PIBT101 PIBT102 COBT1 PIC101 PIC102 COC1 PIC201 PIC202 COC2 PIC301 PIC302 COC3 PIC401PIC402 COC4 PIC501 PIC502 COC5 PIC601PIC602 COC6 PIC701 PIC702 COC7 PIC801 PIC802 COC8 PIC1001 PIC1002 COC10 PIC1101 PIC1102 COC11 PIC1201 PIC1202 COC12 PIC1401 PIC1402 COC14 PIC1501 PIC1502 COC15 PIC1601 PIC1602 COC16 PIC1701 PIC1702 COC17 PIC1801 PIC1802 COC18 PIC1901 PIC1902 COC19 PIC2001 PIC2002 COC20 PIC2101 PIC2102 COC21 PIC2301 PIC2302 COC23 PIC2401 PIC2402 COC24 PIC2501 PIC2502 COC25 PIFAN0HI01PIFAN0HI02 PIFAN0HI03PIFAN0HI04 COFAN0HI PIFAN0LOW01PIFAN0LOW02 PIFAN0LOW03PIFAN0LOW04 COFAN0LOW PIFAN0MED01PIFAN0MED02 PIFAN0MED03PIFAN0MED04 COFAN0MED PIFAN0OFF01PIFAN0OFF02 PIFAN0OFF03PIFAN0OFF04 COFAN0OFF PIL101 PIL102 COL1 PIL201 PIL202 COL2 PIL301 PIL302 COL3 PIL401PIL402 COL4 PILIGHT0OFF01PILIGHT0OFF02 PILIGHT0OFF03PILIGHT0OFF04 COLIGHT0OFF PIP101 PIP102 PIP103 PIP104 COP1 PIU100 PIU101 PIU102 PIU103 PIU104 PIU105 PIU106PIU107PIU108PIU109PIU1010 PIU1011 PIU1012 PIU1013 PIU1014 PIU1015 PIU1016PIU1017PIU1018PIU1019PIU1020 COU1 PIX101PIX102 COX1 PIC301 PIU109 NL0108V PIBT101 PIC101 PIC201PIC501PIC701 PIL102 PIP101 PIU1010 NL03V PIBT102 PIC202 PIC302 PIC502PIC702 PIC801 PIC1001 PIC1101PIC1201 PIC1401 PIC1601PIC1702PIC1801PIC1901PIC2002PIC2101 PIC2301 PIC2401 PIC2501 PIFAN0HI03 PIFAN0LOW03 PIFAN0MED03 PIFAN0OFF03 PILIGHT0OFF03 PIP102 PIU100PIU106 PIU1012 PIU1013 PIX102 PIC2402 PIC2502 PILIGHT0OFF02 PIU102 NLLight0Off PIU1019 NLLightToggle PIAntenna01 PIC1402 PIC1502PIL302 PIL402PIC402PIL401 PIC601 PIU1017 PIC602 PIU1016 PIC802 PIC1501 PIL301 PIC1002 PIL201 PIFAN0HI01 PIFAN0HI04 PIFAN0LOW01 PIFAN0LOW04 PIFAN0MED01 PIFAN0MED04 PIFAN0OFF01 PIFAN0OFF04 PILIGHT0OFF01 PILIGHT0OFF04 PIU1018PIU1020 PIX101 PIU101 NLReverse PIC102 PIC401 PIL101 PIL202 PIU1014 NLRf PIC1102PIC1202 PIFAN0OFF02 PIU1011 NLSpeed0 PIC1602PIC1701 PIFAN0LOW02 PIU103 NLSpeed1 PIC1802PIC1902 PIFAN0MED02 PIU105 NLSpeed3 PIC2001PIC2102 PIFAN0HI02 PIU104 NLSpeed4 PIP104 PIU107 NLSWCLK PIP103 PIU108 NLSWDIO PIC2302 PIU1015 NLVQP

Test Report

Client: Product Designation: 99121 Report Number: 101036110ATL-009 All services undertaken are subject to the following general policy: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST, or any agency of the US Government. Tested by: Tests performed by:Report reviewed by: Standard: Troy Ihle EMC Project Engineer Jeremy O. Pickens Senior Staff Engineer Hunter Fan 7130 Goodlett Farms Parkway, Ste 400 Memphis, TN 38016 Contact: Robert Davis Phone: 901-248-2212 Fax: 901-248-2382 [email protected] TEST REPORT February 26, 2013 Intertek Testing Services NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 47 CFR Part 15, Subpart C (15.231 - Periodic operation in the band 40.66- 40.70 MHz and above 70 MHz) RSS-210, Issue 8, 2010 Page 1 of 33EMC Report for Hunter Fan on the 99121 02/26/2013Report Number: 101036110ATL-009Issued: Intertek 2.0 Test Summary 2.0 Test Summary2.0 Test Summary 2.0 Test Summary 1.0 Introduction and Conclusion 1.0 Introduction and Conclusion1.0 Introduction and Conclusion 1.0 Introduction and Conclusion Test DateTest Full NameResultSection System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup)4.0 Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview)5.0 01/28/2013Restrictions (FCC 15C-15.231 / RSS-210 A1.1)PASS6.0 01/28/2013Duty Cycle Determination (FCC 15A-15.35(c) / RSS-GEN 4.5)PASS7.0 01/18/2013Radiated Emissions (FCC 15.231(b) / RSS-210 A1.1.2)PASS8.0 01/28/2013Bandwidth Requirements (FCC 15.231(c) / RSS-210 A1.1.3)PASS9.0 Revision History (Revision History)10.0 Conducted Emissions for Intentional Radiators (FCC 15C - 15.207) was waived due to the device was battery-powered.NA The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatum text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Page 2 of 33EMC Report for Hunter Fan on the 99121 02/26/2013Report Number: 101036110ATL-009Issued: Intertek 3.0 Description of Equipment Under Test 3.0 Description of Equipment Under Test3.0 Description of Equipment Under Test 3.0 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number Ceiling Fan Remote Hunter Fan 99121 N/A EUT receive date: January 16, 2013 EUT receive condition: Good Description of EUT provided by Client: The EUT was a hand held wireless transmitter used for remote control of a ceiling fan and light assembly. Description of EUT exercising: During testing, the device was powered from a new internal CR2032 battery and configured to transmit continuously. Page 3 of 33EMC Report for Hunter Fan on the 99121 02/26/2013Report Number: 101036110ATL-009Issued: Intertek System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) diagram. (System Setup)diagram. (System Setup) diagram. (System Setup) 4.0 4.04.0 4.0 Method: Record the details of EUTcabling, document the support equipment, and show the interconnections in a block diagram. EUT Setup Diagram Drawing: Page 4 of 33EMC Report for Hunter Fan on the 99121 02/26/2013Report Number: 101036110ATL-009Issued: Intertek System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) diagram. (System Setup)diagram. (System Setup) diagram. (System Setup) 4.0 4.04.0 4.0 None Support Equipment DescriptionManufacturerModel NumberSerial Number None Description EUT Cabling Connection Length Shielding FerritesIDFromTo Data: Page 5 of 33EMC Report for Hunter Fan on the 99121 02/26/2013Report Number: 101036110ATL-009Issued: Intertek Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview) Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview)Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview) Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview)5.0 5.05.0 5.0 Method: Complete the overview spreadsheet. Related Submittal(s) Grants: This repor…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Julian A Martin(Compliance Manager)
[email protected](901)248-2810Fax: (901)248-2382

Test Firm

Intertek Testing Services NA Inc.Charles Parker
[email protected]972-202-8764Fax: 6787752401

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231434 MHz - 434 MHz-

Other Applications from Hunter Fan Company

Remote Control for Ceiling Fan - FCC ID IN2TX61 - Hunter Fan Company
IN2TX61

Remote Control for Ceiling Fan

Sep 11, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX57 - Hunter Fan Company
IN2TX57

Remote Control for Ceiling Fan

Jul 03, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX52 - Hunter Fan Company
IN2TX52

Remote Control for Ceiling Fan

Jan 10, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX50 - Hunter Fan Company
IN2TX50

Remote Control for Ceiling Fan

Jul 29, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control for ceiling fan - FCC ID IN2TX49 - Hunter Fan Company
IN2TX49

Remote control for ceiling fan

Jun 14, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter