FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hunter Fan Company/
  3. IN2TX72

IN2TX72Hunter Home Light Control System

Hunter Fan Company
Hunter Home Light Control System - FCC ID IN2TX72 - Hunter Fan Company
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Oct 14, 2007
Application Purpose
Original Equipment
Date of Application
Sep 30, 2007
Equipment Note
Hunter Home Light Control System
Frequency Range
433.92000000 - 433.92000000
Company
Hunter Fan Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

Schematics

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model 45051 Hunter Home Light Control System Installation and Operation Manual 43012-01 r101107 ENGLISH See page 2 ESPAÑOL Vea la página 37 2 43012-01 TABLE OF CONTENTSIntroduction..............................2Features...................................3Limitations/Warnings ..............4 Transmitter Co ntrols...............5 Receiver Controls....................7Setup.........................................8Home Program........................15 INTRODUCTION The Hunter Home Light Control System is an automated, easy-to-use home timer system. It features two programmable modes that control lighting when you're at home, or when you're away on vacation. It also has a manual mode that allows you to use the Transmitter as a remote control. A convenient keychain remote lets you turn lights on and off from outside your home.The Transmitter controls four light groups. Once the Transmitter is programmed, you can use as many Receivers as you want in each lighting group. Simply assign the additional Receivers to a light group, plug the lamp into the Receiver, and plug the Receiver into a standard home electrical outlet. The System allows an unlimited number of Receivers and Remotes. Vacation Program.....................25Manual Operation.....................30Keychain Remote Operation....31Daily Operation.........................32Transmitter Wall Mount .............34 Maintenance..............................35Technical Support.....................36 43012-01 3 ‡$+RPH3URJUDPZLWKWKUHHPRGHV ~ 7-Day Same mode - allows you to quickly and easily program the same On/Off times for every day of the week either for all Light Groups or for individual Light Groups.~ Week / Weekend mode - allows you to program the same On/Off times for the weekdays, and different On/Off times for the weekend either for all Light Groups or for individual Light Groups.~ Custom mode - allows you to program individual On/Off times for each day of the week, either for all Light Groups or for individual Light Groups. ‡$9DFDWLRQ3URJUDPZLWKWZRPRGHV ~ Home Variable Mode - uses your Home Program settings to randomly turn on light groups for each hour and turn them off after thirty minutes.~ Smart Deterrence Mode EHWZHHQWKHKRXUVRI30DQG306PDUW  Deterrence always keeps at least one Light Group on. Each Light  *URXSVUHPDLQVRQEHWZHHQRQHKRXUDQGRQHKRXUIRUW\¿YH    minutes, depending on how many Light Groups are selected for this mode. The cycle continues through all selected Light Groups. In this way Smart Deterrence simulates someone inside your home moving from one area to another. ‡ A Manual mode that allows you to use the Transmitter as a Remote Control for your lighting. ‡ Convenient Transmitter wall-mounting. ‡ )RULQGRRUXVHRQO\ Features 4 43012-01 ‡ )RUXVHZLWKVZLWFKHGZDOORXWOHWV‡ 0D[LPXPORDGIRUUHFHSWDFOHVLVZDWWV‡ 5HFHLYHUVFRQIRUPWR8/7LPHUVDQG7LPH6ZLWFKHVThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two FRQGLWLRQV  WKLVGHYLFHPD\QRWFDXVHKDUPIXOLQWHUIHUHQFH DQG  WKLVGHYLFHPXVWDFFHSW any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reason-able protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct WKHLQWHUIHUHQFHE\RQHRUPRUHRIWKHIROORZLQJPHDVXUHV‡ ,QFUHDVHWKHVHSDUDWLRQEHWZHHQWKHHTXLSPHQWDQGUHFHLYHU‡ &RQQHFWWKHHTXLSPHQWLQWRDQRXWOHWRQDFLUFXLWGLIIHUHQWI URPWKDWWRZKLFKWKHUHFHLYHU is connected. ‡ &RQVXOWWKHGHDOHURUDQH[SHULHQFHGUDGLR79WHFKQLFLDQIRU KHOS $Q\FKDQJHRUPRGL¿FDWLRQWRWKLVHTXLSPHQWQRWH[SUHVVO\DSSUR YHGE\+XQWHU)DQ&R will void the user’s authority to operate the equipment. Limitations & Warnings 43012-01 5 WIRELESS LAMP TIMER SYSTEM AD BC OFF ON ALL ON SETUP ALL OFF ALL ON All On / Scroll Right / Enter Button All Off / 6FUROO8SSetupButton All On / Scroll Down Button All Off / Scroll Left/BackButton Transmitter Controls Transmitter Controls 6 43012-01 Transmitter Controls (cont.) t)0.& t7"$"5*0/ t."/6"- Program Select Switch Channel Switch 12 3 43012-01 7 Receiver Controls Receiver Controls Light Group Select Dial Channel Select Dial 8 43012-01  5HPRYHWKH%DWWHU\&RYHUIURPWKHEDFNRIWKH7UDQVPLWWHU Setup  6OLGHWKH&KDQQHO6HOHFW6ZLWFKWRDQ\RIWKHWKUHHQXPEHUV QH[WWRLW 12 3 43012-01 9 Setup (cont.)  2QHDFK5HFHLYHUURWDWHWKH&KDQQHO6HOHFW'LDOWRWKHFKDQQ HOWRZKLFK\RXVHWWKH7UDQVPLWWHU Channel Select Switch. Channel Select Dial VKRZQZLWKFKDQQHO VHOHFWHG  7KH+XQWHU+RPH/LJKW&RQWURO6\VWHPGLYLGHVWKHURRPVDQGD UHDVRI\RXUKRPHLQWRIRXU/LJKW Groups labeled A, B, C, and D on the Transmitter keyboard. Assign your rooms and areas to Light Groups, and make a note of the assignments. We suggest that the entry area of your home be as-signed to Light Group A. This is because the Keychain Remote for your Hunter Light Control System operates only Light Group A, and you will want to be able to turn on your entry lighting before you HQWHU$VDPSOH/LJKW*URXSDVVLJQPHQWVFKHPHPLJKWEH Light Group A - Entry Area Light Group B - Living Area Light Group C - Dining Area Light Group D - Master Bedroom 10 43012-01  2QHDFK5HFHLYHUURWDWHWKH/LJKW*URXS6HOHFW'LDOWRWKH/ LJKW*URXSIRUZKLFK…

Text truncated - open the document above for the full version.

Block Diagram

Block Diagram MCU KB8P452 Slide switch Backlight Keyboard Input EEPROM 433MHz RF Tx Board Tx Data (PC3) SCL (PC2) SDA (PD5) (PD1~PD6) (PD1~PD3)(PC0~PC1) (PD0) LCD Display (SEG0~59) (COM0~15 Crystal oscillator 32.768 kHz

Cover Letter(s)

Hunter Fan Company 2500 Frisco Ave Memphis, TN 38114, USA, Web Site: www.hunterfan.com E-Mail: [email protected] Phone: (901) 248-2212 FAX: (901) 248-2382 AGENCY AUTHORIZATION LETTER FCC ID: IN2TX72 Date: Sep 28, 2007 IC: 3558A-HCT03 To whom it may concern: We, the undersigned, hereby authorize SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD of China to act on our behalf, as our agent in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification, Any act carried out by SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months from original date. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely, Robert Davis / Engineer Hunter Fan Company Phone: (901) 248-2212 FAX: (901) 248-2382 E-mail: [email protected]

External Photos

Shenzhen Huatongwei International Inspection Co., Ltd Top View of EUT Bottom View of EUT Shenzhen Huatongwei International Inspection Co., Ltd Front View of EUT Back View of EUT Shenzhen Huatongwei International Inspection Co., Ltd Left View of EUT Right View of EUT

ID Label/Location Info

The FCC ID & IC Label and Location This Device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: IN2TX72 IC: 3558A-HCT03 M/N: 88083 Company Name: HUNTER FAN Company FCC & IC label location

Internal Photos

Shenzhen Huatongwei International Inspection Co., Ltd Internal Photos of EUT Shenzhen Huatongwei International Inspection Co., Ltd

Schematics

H007-MCU_NEW.sch-1 - Thu Sep 13 15:29:52 2007

Test Report

Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 1 of 25 Rev. 00 ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C AND RSS-210 REQUIREMENT OF AutoSmart Controller FCC ID: IN2TX72 IC: 3558A-HCT03 MODEL No.: 88083 BRAND NAME: N/A REPORT NO: WE07090002 ISSUE DATE: Sep 27, 2007 Prepared for HUNTER FAN COMPANY 2500 FRISCO AVE MEMPHIS, TN 38114, USA Prepared by SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD d.b.a. SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD HUATONGWEI BUILDING, KEJI RD. 12 S., HIGH-TECH PARK, NANSHAN DISTRICT, SHENZHEN, GUANGDONG, P.R.CHINA TEL: 86-755-26748099 FAX: 86-755-26748005 Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 2 Rev. 00 VERIFICATION OF COMPLIANCE Applicant: Hunter Fan Company 2500 Frisco Ave Memphis , TN 38114, USA Product Description: AutoSmart Controller Brand Name: N/A Model Number: 88083 Listed Model N/A Serial Number: N/A File Number: WE07090002 Date of Test: Sep 19, 2007 ~ Sep 20,2007 We hereby certify that: The above equipment was tested by SHENZHEN HUA TONG WEI INTERNATIONAL INSPECTION CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with radiated emission limits of FCC Rules Part 15.231 and RSS-210 Issue 7 June 2007. The test results of this report relate only to the tested sample identified in this report. Approved By Reviewed By Jimmy Li / Executive Manager Tracy Qi / RF Engineer SHENZHEN HUA TONG WEI SHENZHEN HUA TONG WEI INTERNATIONAL INSPECTION CO., LTD INTERNATIONAL INSPECTION CO., LTD Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 3 Rev. 00 Table of Contents 1. GENERAL INFORMATION............................................................................................................. 5 1.1 PRODUCT DESCRIPTION........................................................................................................................... 5 1.2 RELATED SUBMITTAL(S) / GRANT (S)...................................................................................................... 5 1.3 TEST METHODOLOGY...............................................................................................................................5 1.4 TEST FACILITY.......................................................................................................................................... 5 1.5 SPECIAL ACCESSORIES............................................................................................................................ 5 1.6 EQUIPMENT MODIFICATIONS.................................................................................................................... 6 1.7. LABORATORY ACCREDITATIONS AND LISTINGS........................................................................................ 6 2. SYSTEM TEST CONFIGURATION............................................................................................... 8 2.1 EUT CONFIGURATION.............................................................................................................................. 8 2.2 EUT EXERCISE......................................................................................................................................... 8 2.3 TEST PROCEDURE.................................................................................................................................... 8 2.4 LIMITATION................................................................................................................................................ 8 2.5 CONFIGURATION OF TESTED SYSTEM..................................................................................................... 9 3. DESCRIPTION OF TEST MODES................................................................................................ 9 4. CONDUCTED EMISSIONS TEST (NOT APPLICABLE TO THIS DEVICE)................. 10 4.1 MEASUREMENT PROCEDURE:................................................................................................................ 10 4.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 10 4.3 MEASUREMENT EQUIPMENT USED:....................................................................................................... 11 4.4 MEASUREMENT RESULT:........................................................................................................................ 11 5. RADIATED EMISSION TEST....................................................................................................... 12 5.1 MEASUREMENT PROCEDURE................................................................................................................. 12 5.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 12 5.3 MEASUREMENT EQUIPMENT USED:....................................................................................................... 13 5.4 FIELD STRENGTH CALCULATION............................................................................................................ 13 5.5 MEASUREMENT RESULTS...................................................................................................................... 14 6. 99% OCCUPIED BANDWIDTH................................................................................................... 15 6.1 MEASUREMENT PROCEDURE................................................................................................................. 15 6.2 TEST SET-UP (BLOCK DIAGRAM OF CO…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen Huatongwei International Inspection Co., Ltd Radiated Emission Setup Photo

Test Setup Photos

Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 1 of 25 Rev. 00 ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C AND RSS-210 REQUIREMENT OF AutoSmart Controller FCC ID: IN2TX72 IC: 3558A-HCT03 MODEL No.: 88083 BRAND NAME: N/A REPORT NO: WE07090002 ISSUE DATE: Sep 27, 2007 Prepared for HUNTER FAN COMPANY 2500 FRISCO AVE MEMPHIS, TN 38114, USA Prepared by SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD d.b.a. SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD HUATONGWEI BUILDING, KEJI RD. 12 S., HIGH-TECH PARK, NANSHAN DISTRICT, SHENZHEN, GUANGDONG, P.R.CHINA TEL: 86-755-26748099 FAX: 86-755-26748005 Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 2 Rev. 00 VERIFICATION OF COMPLIANCE Applicant: Hunter Fan Company 2500 Frisco Ave Memphis , TN 38114, USA Product Description: AutoSmart Controller Brand Name: N/A Model Number: 88083 Listed Model N/A Serial Number: N/A File Number: WE07090002 Date of Test: Sep 19, 2007 ~ Sep 20,2007 We hereby certify that: The above equipment was tested by SHENZHEN HUA TONG WEI INTERNATIONAL INSPECTION CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with radiated emission limits of FCC Rules Part 15.231 and RSS-210 Issue 7 June 2007. The test results of this report relate only to the tested sample identified in this report. Approved By Reviewed By Jimmy Li / Executive Manager Tracy Qi / RF Engineer SHENZHEN HUA TONG WEI SHENZHEN HUA TONG WEI INTERNATIONAL INSPECTION CO., LTD INTERNATIONAL INSPECTION CO., LTD Shenzhen Huatongwei International Inspection Co., Ltd REPORT NO: WE07090002 FCC ID: IN2TX72 IC: 3558A-HCT03 DATE: 09/27/2007 Page 3 Rev. 00 Table of Contents 1. GENERAL INFORMATION............................................................................................................. 5 1.1 PRODUCT DESCRIPTION........................................................................................................................... 5 1.2 RELATED SUBMITTAL(S) / GRANT (S)...................................................................................................... 5 1.3 TEST METHODOLOGY...............................................................................................................................5 1.4 TEST FACILITY.......................................................................................................................................... 5 1.5 SPECIAL ACCESSORIES............................................................................................................................ 5 1.6 EQUIPMENT MODIFICATIONS.................................................................................................................... 6 1.7. LABORATORY ACCREDITATIONS AND LISTINGS........................................................................................ 6 2. SYSTEM TEST CONFIGURATION............................................................................................... 8 2.1 EUT CONFIGURATION.............................................................................................................................. 8 2.2 EUT EXERCISE......................................................................................................................................... 8 2.3 TEST PROCEDURE.................................................................................................................................... 8 2.4 LIMITATION................................................................................................................................................ 8 2.5 CONFIGURATION OF TESTED SYSTEM..................................................................................................... 9 3. DESCRIPTION OF TEST MODES................................................................................................ 9 4. CONDUCTED EMISSIONS TEST (NOT APPLICABLE TO THIS DEVICE)................. 10 4.1 MEASUREMENT PROCEDURE:................................................................................................................ 10 4.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 10 4.3 MEASUREMENT EQUIPMENT USED:....................................................................................................... 11 4.4 MEASUREMENT RESULT:........................................................................................................................ 11 5. RADIATED EMISSION TEST....................................................................................................... 12 5.1 MEASUREMENT PROCEDURE................................................................................................................. 12 5.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 12 5.3 MEASUREMENT EQUIPMENT USED:....................................................................................................... 13 5.4 FIELD STRENGTH CALCULATION............................................................................................................ 13 5.5 MEASUREMENT RESULTS...................................................................................................................... 14 6. 99% OCCUPIED BANDWIDTH................................................................................................... 15 6.1 MEASUREMENT PROCEDURE................................................................................................................. 15 6.2 TEST SET-UP (BLOCK DIAGRAM OF CO…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Julian A Martin(Compliance Manager)
[email protected](901)248-2810Fax: (901)248-2382

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-

Other Applications from Hunter Fan Company

Remote Control for Ceiling Fan - FCC ID IN2TX61 - Hunter Fan Company
IN2TX61

Remote Control for Ceiling Fan

Sep 11, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX57 - Hunter Fan Company
IN2TX57

Remote Control for Ceiling Fan

Jul 03, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX52 - Hunter Fan Company
IN2TX52

Remote Control for Ceiling Fan

Jan 10, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control for Ceiling Fan - FCC ID IN2TX50 - Hunter Fan Company
IN2TX50

Remote Control for Ceiling Fan

Jul 29, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control for ceiling fan - FCC ID IN2TX49 - Hunter Fan Company
IN2TX49

Remote control for ceiling fan

Jun 14, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter