CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 46 of 50 6 Photographs of EUT 6.1 External Photos Photo 1: Photo 2: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 47 of 50 Photo 3: Photo 4: OR2-SBLP1-S800-I (ID ́s not actual) CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 48 of 50 Photo 5: OR2-SBLP1-S800-I (ID ́s not actual) Photo 6: OR2-SBLP1-S800-I (ID ́s not actual) CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 49 of 50 Photo 7: Photo 8: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 50 of 50 Photo 9: Photo 10:
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 8 of 50 3 Measurements and results 3.1 IDEN 3.1.1 RF Exposure FCC: FCC §1.1307, §2.1091 IC: RSS-131 §5.5 MPE calculation These equations are generally accurate in the far field of an antenna but will over predict power density in the near field, where they could be used for making a “worst case” prediction. S = PG/4πR 2 where S = power density ( in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units e.g. mW) G = power gain of the antenna in the direction of interest relative to the isotropic radiator R = distance to the center of radiation of the antenna (appropriate units e.g. cm) CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 9 of 50 Antenna gain Worst case calculations: (S4πR 2 / P) OR2-SBLP1-S800-I Downlink: Maximum peak output power at antenna input terminal (dBm): 21.0 Maximum peak output power at antenna input terminal (mW): 125.9 Prediction distance (cm): 20 Prediction frequency (MHz): 865.975 MPE limit for uncontrolled exposure at predication frequency (mW/cm ): 0.577 Maximum Antenna Gain (numeric): 23.05 Antenna Gain, typical (dBi): 13.63 Uplink: Maximum peak output power at antenna input terminal (dBm): 20.9 Maximum peak output power at antenna input terminal (mW): 123.0 Prediction distance (cm): 20 Prediction frequency (MHz): 813.500 MPE limit for uncontrolled exposure at predication frequency (mW/cm ): 0.542 Maximum Antenna Gain (numeric): 22.16 Antenna Gain, typical (dBi): 13.46 Test result: The device is compliant with the requirement MPE limit for uncontrolled exposure at predication frequency. The maximum allowed antenna gain for a distance of 20 cm is for Downlink 13.63 dBi and for Uplink 13.46 dBi.
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 1 of 50 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: IC 3462C-1 TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Accredited Bluetooth ® Test Facility (BQTF) Test report No. : 1-1135-01-06-A/09 Applicant : RADIO FREQUENCY SYSTEMS Type : OR2-SBLP1-S800-I Test Standard : Part 90 RSS-131 Issue 2 FCC ID : IWD-W3900005 Certification No. IC : 1634B-W3900005 The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Cetecom ICT is under license CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 2 of 50 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT......................................................................................................................................... 4 1.4 APPLICATION DETAILS.......................................................................................................................................... 4 1.5 ADDITIONAL EUT INFORMATION FOR IC CANADA (APPENDIX 2).......................................................................... 5 1.6 TEST SETUP........................................................................................................................................................... 6 1.7 TEST STANDARDS.................................................................................................................................................. 6 2 STATEMENT OF COMPLIANCE .......................................................................................................................... 7 2.1 SUMMARY OF MEASUREMENT RESULTS................................................................................................................ 7 3 MEASUREMENTS AND RESULTS ....................................................................................................................... 8 3.1 IDEN..................................................................................................................................................................... 8 3.1.1 RF Exposure ................................................................................................................................................. 8 3.1.2 RF Power Output ........................................................................................................................................ 10 3.1.3 Radiated Emissions..................................................................................................................................... 11 3.1.4 Conducted Spurious Emissions ................................................................................................................... 21 3.1.5 Block Edge Compliance .............................................................................................................................. 25 3.1.6 Occupied Bandwidth ................................................................................................................................... 28 3.1.7 Intermodulation Tests ................................................................................................................................. 35 3.1.8 Out of Band Rejection ................................................................................................................................. 38 3.1.9 Conducted Emissions <30 MHz §15.107/207....................................................................................... 39 4 USED TEST EQUIPMENT ..................................................................................................................................... 41 5 PHOTOGRAPHS OF TEST SET-UP .................................................................................................................... 44 6 PHOTOGRAPHS OF EUT...................................................................................................................................... 46 6.1 EXTERNAL PHOTOS............................................................................................................................................. 46 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 3 of 50 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing laboratory Company name: Cetecom ICT Services GmbH Address: Untertürkheimerstr. 6-10 D-66117 Saarbruecken Germany Laboratory accreditation: DAR-Registration No. DAT-P-176/94-D1 Bluetooth Qualification Test Facility (BQTF) Federal Communications Commission (FCC) Identification/Registration No : 90462 Responsible for testing laboratory: Stefan Bös Phone: +49 681 598 0 Fax: +49 681 598 9075 email: [email protected] 1.2. Notes The test results of this test report rel…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 44 of 50 5 Photographs of Test Set-up Photo 1: Radiated Emissions Photo 2: Radiated Emissions CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-8412 Fax: -8484 Test report No.: 1-1135-01-06-A/09 Date: 2009-07-13 Page 45 of 50 Photo 3: Radiated Emissions Photo 4: Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 9 | 851 MHz - 866 MHz | 124.00 mW | GXW | Amp |

PCS 1900 Pico-repeater
Equipment Class
PCB - PCS Licensed Transmitter
CDMA/CELL 850 Pico-repeater
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
iDEN 900 Pico-repeater
Equipment Class
PCB - PCS Licensed Transmitter
PCS 1900 Pico-repeater
Equipment Class
PCB - PCS Licensed Transmitter
Multi-channel Repeater
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter