11717 Exploration Lane, Germantown, MD 20876 Tel: (301) 428โ5500 Fax: (301) 428 โ1868/2830 1027144โ 0001 Draft โ Revision D.01 December 17, 1999 Remote Terminal Installation and User Manual 1027144โ 0001 Draft โ Revision D.01ii For important standards compliance information, see appendix B. Copyright ๏ฃฉ1999 Hughes Network Systems, a Hughes Electronics Corporation company All rights reserved. This publication and its contents are proprietary to Hughes Network Systems, a Hughes Electronics Corporation company. No part of this publication may be reproduced in any form or by any means without the written permission of Hughes Network Systems, 11717 Exploration Lane, Germantown, Maryland 20876. Hughes Network Systems has made every effort to ensure the correctness and completeness of the material in this document. Hughes Network Systems shall not be liable for errors contained herein. The information in this document is subject to change without notice. Hughes Network Systems makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trademarks AIReach๏ฃช is a trademark of Hughes Network Systems. Other trademarks, marks, names, or product names referenced in this publication are the property of their respective owners, and Hughes Network Systems neither endorses nor otherwise sponsors any such products or services referred to herein. 1027144โ 0001 Draft โ Revision D.01iii RT installation Contents About this manual v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Important safety information vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation summary 1โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Remote terminal (RT) reference drawing 1โ2. . . . . . . . . . . . . . . . . . . . . 1.2 Installation summary and checklist 1โ3. . . . . . . . . . . . . . . . . . . . . . . . . . 2 Prerequisites 2โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Review site data and plans 2โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Plan ahead for building access 2โ2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Tools needed for installation 2โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Prerequisites for commissioning 2โ7. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installing indoor RT equipment 3โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Rack grounding 3โ2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Installing IDUs 3โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 Power supplies 3โ8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 Installing the CCM 3โ24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 SSIs 3โ28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 Installing expansion IDUs (EIDUs) 3โ34. . . . . . . . . . . . . . . . . . . . . . . . . 4 Installing IFL cables 4โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Roof and ladder safety 4โ2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Handling materials 4โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 IFL cable specifications 4โ4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4 Overview: IFL plan 4โ5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 Determining the IFL cable route 4โ6. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6 Penetrating the roof 4โ7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7 Installing the penetration sleeve 4โ8. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8 Installing the IFL cable inside the building 4โ9. . . . . . . . . . . . . . . . . . . . 4.9 Installing the remote lightning arrestor 4โ10. . . . . . . . . . . . . . . . . . . . . . . 4.10 Installing the IFL cable on the roof 4โ14. . . . . . . . . . . . . . . . . . . . . . . . . . 4.11 Multiple IFL cables 4โ17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing mast mounts 5โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Overview 5โ2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 ODU location 5โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Roof types 5โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 Mast mount types 5โ3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Standard nonpenetrating mount 5โ4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 Using existing structures as ODU mounts 5โ11. . . . . . . . . . . . . . . . . . . . 1027144โ 0001 Draft โ Revision D.01iv RT installation 6 Installing ODUs 6โ1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Introduction 6โ2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 Transporting the ODU to the roof 6โ4. . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 ODU installation and alignment tools 6โ5. . . . . . . . . . . . . . . . . . . . . . . . 6.4 Installing the temporary collar 6โ6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 Installing the antenna mount 6โ10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6 Attaching the antenna to the mount 6โ12. . . . . . . . . . . . . . . . . . . . . . . . . . 6.7 Initial (coarse) antenna azimuth adjustment 6โ15. . . . . . . . . . . . . . . . . . . 6.8 Adjusting the antenna elevation 6โ17. . . . . . . . . โฆ
Text truncated - open the document above for the full version.
EXHIBIT 3 MANUFACTURING AND PRODUCT INFORMATION
1 Frank Coperich Federal Communications Commission Laboratory 7435 Oakland Mills Road, Columbia MD 21046 July 5, 2000 RE: CONFIDENTIALITY REQUEST FCC ID K3Y-38SH-001 Applicant: Hughes Network Systems Correspondence Reference Number: 14863 731 Confirmation Number: EA97766 Date of Original E-Mail: 06/30/2000 Dear Mr. Coperich I would like to address two of the questions that have been requested in your correspondence letter No: 14863 dated 06/30/2000. 1. Confidentiality Request The part of the above application has been requested confidentiality. The reason for this is that two exhibits (EXHIBIT 5 & EXHIBIT 8) contain detailed schematics that could lead to technology patent disclosure. The technology is very new and therefore all precautions have to be taken to keep this information confidential from public access. 2. Please explain why the transmit frequency ranges shown on Test Report Pages 9 and 12 do not agree The page 9 was not correct. The Frequency range should be as follows: HUB SUB (High Band SUB unit) Tx (38950 โ 39400) MHz HUB HUB (High Band HUB unit) Tx (38650 โ 40000) MHz Thank you, for accepting our request. Regards John Rymkiewicz Technical Manager Hughes Network Systems
1 Frank Coperich Federal Communications Commission Laboratory 7435 Oakland Mills Road, Columbia MD 21046 6/1/1999 FCC ID: K3Y-38SH-001 Dear Mr. Coperich Please accept the application for the approval of the K3Y-38SH-001 Point to Multipoint 38 GHz System to the FCC Part 101 Type Acceptance requirements. The system is similar to the previously approved, except for the change to the frequency band. The Files have been submitted electronically to the Federal Communications Commission Laboratory Rega rds John Rymkiewicz
EXHIBIT 4 EXTERNAL PHOTOS Figure 1 Front View1 Figure 2 Front View2 Figure 3 ODU HUB โ Open cover Figure 4 ODU and Antenna - Front View Figure 5 ODU and IDU โ Front View
EXHIBIT 1 IDU & ODU LABLES This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: POWER DOWN ODU BEFORE CONNECTING OR DISCONNECTING IF 1024668-0014 S/N: Rev: FCC ID: K3Y-38SH-001 AIReach Broadband 38GHz High Sub PRODUCT AIReach Broadband IDU 1026356 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment shall be installed in accordance with the HNS installation manual, only in restricted access areas in business and customer premises applications in accordance with articles 110-16, 110-17, and 110-18 of the National Electric Code ANSI/NFPA No. 70. LIS TED IT E 4N11 ยฎ CUS FCC ID: K3Y-38HL-001 K3Y-38SL-001 K3Y-38HH-001 K3Y-38SH-001 K3Y-24HX-001 K3Y-24SX-001
EXHIBIT 2 COMPANY NAME AND MAILING ADDRESS COMPANY NAME AND MAILING ADDRESS Hughes Network Systems 11717 Exploration Lane Germantown, MD 20876 Telephone Number: (301) 428-5500 Fax number: (301) 428-2880
EXHIBIT 9 INT ERNAL PHOT OS Figure 1: Open ODU SUB photo 1 Figure 2: Open ODU SUB photo 2 Figure 3: Open ODU SUB photo 3
EXHIBIT 6 SUB Test plan and Report Hughes Proprietary II No. 1029622 Hughes Proprietary II Rev.1 Sheet 2 of 58 Form E75aHughes Network Systems DateRevRevision Record Approved 12/17/990.9Test planJR 5/15/001Test Report Released JR PMP 38.95 to 39.3GHz Agency Certification Test Report For SUB High Band Prepared for Hughes Network Systems 11717 Exploration Lane Germantown, MD 20876 Hughes Proprietary II Copyright ยฉ 2000 Hughes Network Systems Notice of Proprietary Information This document and its contents are proprietary to Hughes Network Systems and are i ntended solely for the internal use of Hughes Network Systems. This publication and its contents may not be reproduced or distributed for any other purpose without the written permission of Hughes Network Systems. Job: 01040ApprovalsDate Originator: S. Albanna4/17/00 Hughes Network Systems Approved: J. Rymkiewicz5/30/00 Checked: Title: PMP 38.95 to 39.3GHz Agency Certification Test Report For SUB High Band Sheet 2 of 1 CAGE No. 52571 No. 1029622 Hughes Proprietary II No. 1029622 Hughes Proprietary II Rev.1 Sheet 3 of 58 Form E75aHughes Network Systems . Hughes Proprietary II No. 1029622 Hughes Proprietary II Rev.1 Sheet 4 of 58 Form E75aHughes Network Systems TABLE O F CONTENTS 1.0 OVERVIEW ........................................................................................................................................ 9 1.1 PRODUCT DESCRIPTION................................................................................................................ 9 1.2 CHANNELIZATION .......................................................................................................................... 11 1.3 APPLICABLE STANDARDS............................................................................................................ 12 1.4 REFERENCE DOCUMENTS........................................................................................................... 13 2.0 SETUP.............................................................................................................................................. 14 2.1 EQUIPMENT LIST ........................................................................................................................... 14 2.2 TEST SETUPS................................................................................................................................. 16 3.0 TRANSMITTER TESTS................................................................................................................... 18 3.1 THE OUTPUT POWER.................................................................................................................... 18 3.1.1 Performance Specifications........................................................................................................ 18 3.1.2 Test Procedures........................................................................................................................ 18 3.1.3 Test Configuration ..................................................................................................................... 19 3.1.4 Test Results.............................................................................................................................. 19 3.2 OCCUPIED BANDWIDTH............................................................................................................... 25 3.2.1 Performance Specifications........................................................................................................ 25 3.2.2 Test Procedures........................................................................................................................ 25 3.2.3 Test Configuration ..................................................................................................................... 26 3.2.4 Test Results.............................................................................................................................. 27 3.3 CONDUCTED SPURIOUS EMISSIONS FROM THE TRANSMITTER.......................................... 31 3.3.1 Performance Specifications........................................................................................................ 31 3.3.2 Test Procedures........................................................................................................................ 31 3.3.3 Test Configuration ..................................................................................................................... 32 3.3.4 Test Results.............................................................................................................................. 34 3.3.4.1 Channel 8A1.......................................................................................................................................................... 35 3.3.4.2 Channel 14A4 ........................................................................................................................................................ 38 3.4 RADIATED SPURIOUS EMISSIONS FROM THE TRANSMITTER .............................................. 41 3.4.1 Performance Specifications........................................................................................................ 41 3.4.2 Test Procedures........................................................................................................................ 41 3.4.3 Test Configuration ..................................................................................................................... 42 3.4.4 Test Results.............................................................................................................................. 45 1-18GHz ............................................................................................................................................................................. 46 3.4.4.2 Horizontal Polarization, 18-40GHz ..................................................................................โฆ
Text truncated - open the document above for the full version.
EXHIBIT 7 TEST SETUP PHOTOS Figure 1 Radiated Emission (18-220 GHz) test setup Figure 2: Radiated Emission Test setup (Open Field Site) (30 MHz-18 GHz) Figure 3: Conducted Spurious Emission Test setup
11717 Exploration Lane ยท Germantown, Maryland ยท United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 101 | 38.95 GHz - 39.40 GHz | 63.00 mW | 12M5DXW | 4.6 ppm |

Thuraya IP+ Broadband Satellite IP Modem with WLAN
Equipment Class
DTS - Digital Transmission System
Satellite Terminal with WLAN functionality
Equipment Class
DTS - Digital Transmission System
Land Portable Terminal
Equipment Class
DTS - Digital Transmission System
Land Mobile Terminal
Equipment Class
DTS - Digital Transmission System
Broadband Satellite IP Modem
Equipment Class
DTS - Digital Transmission System