Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 3 | 22,74,9 | 406.1 MHz - 470 MHz | 40 W | 4K00F2D | 0.5
ppm |
Grant NotesOutput power is listed as conducted and is continuously variable between 1 and 40 Watts. Repeater mode operation of this device is restricted to pair channels in a single band with the signal received from another station or device on one frequency retransmitted on a different frequency. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50% for 40W operating mode and 100% for 25W operating mode.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 130cm from all persons for the 40W, 50% for push-to-talk operating mode and 145cm from all persons for the 25W, 100% for repeater operating mode. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna used for this transmitter must not be greater than 0 dBd. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled RF Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.