Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 131 | 9 | 851 MHz - 870 MHz | 35 W | 4K00F2D | 1
ppm |
Grant NotesOutput power is listed as conducted and is continuously variable down to 5 Watts for 136-520 MHz and 2W for 700/800 MHz bands. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. The antenna(s) used for this transmitter must be installed to provide a separation distance from persons, depending on operating frequency, of at least 34-67 cm in an Occupational/Controlled environment and 90-161 cm in a General Population/Uncontrolled environment (bystanders).
The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna used for this transmitter must not be greater than 0 dBd.
This device must be restricted to work related operations. All qualified end-users of this device must have the knowledge to control their/public exposure conditions and/or duration to comply with Occupational /Controlled requirements, including operation among bystanders. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.